| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EAB1-2000 / EAB1-95 |
| Price | USD 1,020 (FOB Shanghai) |
| Instrument Category | Aflatoxin B1 Quantification System |
| Detection Principle | Solid-Phase Enzyme-Linked Immunosorbent Assay (ELISA) |
| Wavelength | 450 ± 2 nm (standard interference filter) |
| Absorbance Range | –0.041 to 1.999 A |
| Detection Limit | 0.1 ng/mL |
| Quantitative Range | 0.1–1.0 ng/mL (ppb) |
| Sensitivity | < 0.1 ng/mL |
| Accuracy | ±0.1 ng/mL |
| Throughput | 20 samples/hour |
| Light Source | LED (3.6 V / 20 mA) |
| Operating Environment | 5–35 °C, ≤85% RH |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Dimensions (EAB1-95) | 350 × 270 × 210 mm |
| Weight (EAB1-95) | 9 kg |
| Dimensions (EAB1-2000) | 410 × 264 × 110 mm |
| Weight (EAB1-2000) | 10 kg |
| Power Consumption | 37 W (EAB1-95), 40 W (EAB1-2000) |
| Transmittance Stability (EAB1-2000) | ≤0.3% T/5 min (bright), ≤0.2% T/5 min (dark) |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Consistometer |
| Construction | Stainless steel body with electropolished 2 mm stainless steel channel |
| Sample volume | 75 mL |
| Dimensions (L × W × H) | 35.6 cm × 8.9 cm × 14.0 cm (14 in × 3.5 in × 5.5 in) |
| Base plate scale division | 0.5 cm |
| Leveling | Dual adjustable leveling screws + bubble level |
| Flow gate | Spring-loaded, instantaneous release mechanism |
| Compliance | Designed to meet ASTM D1200, ISO 2555, and AOAC Official Method 956.02 for consistency testing of semi-solid food products |
| Brand | ENSOUL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Lipstick-Specific Texture Analyzer |
| Pricing | Available Upon Request |
| Brand | ENSOUL |
|---|---|
| Origin | Beijing, China |
| Model | ENS-iPilot |
| Vertical Travel Range | 0–300 mm |
| Position Resolution | ≤ 0.1 µm |
| Speed Range | 0.01–20 mm/s (adjustable in 0.01 mm/s increments) |
| Brand | ENSOUL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ENS Series for Pharmaceutical Applications |
| Pricing | Available Upon Request |
| Brand | ENSoul |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ENS Series Texture Analyzer (Materials-Focused Configuration) |
| Pricing | Available Upon Request |
| Brand | ENSoul |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ENS Tobacco Texture Analyzer |
| Pricing | Available Upon Request |
| Brand | ENSoul |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ENS-iPro |
| Pricing | Available Upon Request |
| Brand | ENSoul |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ENS-iTouch |
| Pricing | Available Upon Request |
| Brand | ENSOUL |
|---|---|
| Model | HSS20 |
| Origin | Beijing, China |
| Sample Capacity | 20 positions |
| Sample Zone Temperature Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±1 °C |
| Operating Ambient Temperature | 10–35 °C |
| Relative Humidity | <85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Display Interface | Method parameter configuration, real-time operational status, elapsed runtime, and timestamp (YYYY-MM-DD-HH) |
| Key | Brand: ENSOUL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MFT2 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MA2 |
| Pricing | Available Upon Request |
| Brand | Fitlylab |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FITLY-9616 |
| Function Type | Multi-analyte (Simultaneous Detection of 30+ Food Contaminants & Additives) |
| Sample Compatibility | Liquid, Solid, Semi-solid Extracts (Homogenized or Centrifuged) |
| Wavelength Range | 410–900 nm (Fixed LED Sources at 410, 536, 595, 620 nm) |
| Detection Channels | 16-Channel Photometric Array |
| Photometric Repeatability | ≤ ±1% T |
| Immunoassay Detection Mode | Single-Channel CCD-Based Lateral Flow Reader (3-Megapixel, 2048×1536 Resolution, Reflective T/C Quantification) |
| T/C Accuracy | ≤ ±0.1 T/C |
| T/C Precision (CV) | ≤ 5% |
| Stability | ≤ 0.1 T/C over 10 min |
| Assay Time | <10 s per lateral flow strip |
| Data Export Format | Excel (.xlsx) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, 10/100 Mbps Ethernet |
| Onboard Storage | 32 GB SSD |
| RAM | 4 GB |
| CPU | Dual-core 1.6 GHz |
| Display | 10.2-inch Full-color Capacitive Touchscreen |
| Weight | ≤ 3.0 kg |
| Brand | Fitlylab |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RVLM |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Solid, Liquid, Surface, Paste, and Slurry Samples |
| Optical Detection | Triple-wavelength Simultaneous Photometric Analysis |
| Detection Channels | 8 Independent Wells |
| Detection Time | Inversely Proportional to Target Microbial Load (as low as <2 h for ≥10⁸ CFU/mL) |
| Repeatability | High (CV <15% under standardized conditions) |
| Regulatory Compliance | ISO 16140:2003 Validated Alternative Method |
| Brand | Jida Xiaotian’e |
|---|---|
| Model | GDYQ-100A2 |
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Detection Limit | 5.0 mg/kg |
| Measurement Range | 0.0–500.0 mg/kg |
| Accuracy | ±2% |
| Assay Time | ≤10 min per sample |
| Display | Backlit LCD with Chinese interface |
| Control System | Embedded MCU with data logging, parameter configuration, statistical analysis, and USB/RS232 connectivity |
| Sample Prep | Dedicated extraction kit and single-use reagent cartridges |
| Compliance | Designed per GB 5009.287–2023 (National Food Safety Standard – Determination of Formaldehyde Sulfoxylate in Foods) |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XQ-600 |
| Price | Upon Request |
| Measurement Range | 0–300 mg KOH/100 g dry matter |
| Resolution | 0.01 mg KOH/100 g dry matter |
| Repeatability | RSD ≤ 0.3% |
| Minimum Dispensing Volume | 0.625 µL |
| Titration Modes | Rapid Titration, Precise Titration |
| Preloaded Methods | Corn, Rice (Paddy), Wheat (100 method slots) |
| Compliance | GB/T 15684–1995, GB 5510–1985, GB/T 20569–2006, GB/T 20570–2006, GB/T 20571–2006 |
| Interfaces | RS232C, Parallel Printer Port |
| Software | Embedded real-time monitoring & PC-based data management suite |
| Brand | Forerunner |
|---|---|
| Model | ZY-400 Series |
| Origin | Beijing, China |
| Instrument Type | Automated Microbiological Assay System for β-Lactamase Detection in Milk and Dairy Products |
| Measurement Principle | Turbidimetric/Zone-of-Inhibition-Based Enzymatic Activity Quantification |
| Resolution | 0.0105 mm |
| Repeatability Precision | ≤0.02 mm |
| Inter-instrument Variation | ≤0.5% |
| Potency Reproducibility | ≤0.5% |
| Compliance Framework | Aligned with Chinese National Standard for Detection of Susceptible β-Lactamases in Milk (e.g., GB/T 22338–2008 or equivalent) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Alphatec™ FNO |
| Application | Falling Number determination per ISO 3093, AACC 56-81B, ICC 107/1, and ASTM D7827 |
| Sample Types | Wheat, Rye, Barley, Sorghum, Flour, and other cereal-based materials |
| Measurement Principle | Viscosity-based enzymatic hydrolysis of starch gel under standardized boiling conditions |
| Display | 7-inch capacitive touchscreen interface with multilingual OS support |
| Compliance | Fully aligned with GLP/GMP data integrity requirements |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | BacSomatic |
| Automation | Fully Automatic |
| Analysis Speed | 40 samples/hour |
| Detection Range | SCC: 100,000–1,500,000 cells/mL |
| IBC | 5,000,000–20,000,000 IBC/mL |
| Repeatability | SCC: CV < 3% at 500,000 cells/mL |
| Accuracy | SCC: Typical Sy,x < 0.25 log units vs. Standard Plate Count (SPC) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CombiFoss 7 |
| Automation | Fully Automatic |
| Analysis Speed | Up to 600 samples/hour |
| Fat Detection Range | 0–15% |
| Repeatability (CV) | <0.5% |
| Fat Precision (CV) | <1.0% |
| Sample Types | Bovine, Ovine, Caprine, and Buffalo Milk |
| Key Parameters | Fat, True Protein, Crude Protein, Casein, Lactose, Total Solids, Non-Fat Solids, Urea, Citric Acid, Free Fatty Acids, Fatty Acid Profile, Freezing Point, pH, Ketosis Screening (BHB & Acetone), Adulteration Detection, Somatic Cell Count (SCC), Differential Somatic Cell Count (DSCC) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CombiFoss 7 |
| Automation Level | Fully Automatic |
| Analysis Throughput | 600 samples/hour |
| Somatic Cell Count (SCC) Range | 0–10 × 10⁶ cells/mL |
| Repeatability | < 2% CV |
| Accuracy | ±0.1–1.5 × 10⁶ cells/mL |
| Sample Temperature Range | 30–42 °C |
| Regulatory Compliance | Designed for ISO 8570, IDF 141, AOAC 991.19, and EU Regulation (EC) No 853/2004 compliance |
| Detection Capabilities | Fat, Protein, True Protein, Lactose, Total Solids, Non-Fat Solids, Urea, Citric Acid, Freezing Point, Casein, Free Fatty Acids, pH, Monounsaturated Fatty Acids (MUFA), Polyunsaturated Fatty Acids (PUFA), Total Unsaturated Fatty Acids, Total Saturated Fatty Acids, Sample Inlet Temperature, Somatic Cell Count (with FM FC module) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | DairyScan |
| Automation | Fully Automatic |
| Analysis Time | 45 seconds per sample (15 sub-samples per run) |
| Measurement Range | Fat 0–36% w/w |
| Repeatability | ≤0.25% CV |
| Accuracy | ≤1.0% CV |
| Detection Principle | Near-Infrared (NIR) Transmission Spectroscopy |
| Sample Throughput | Up to 80 samples/hour (typical operational rate) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fibertec 8000 |
| Principle | Gravimetric Crude Fiber and Detergent Fiber Analysis (Weende & van Soest Methods) |
| Sample Throughput | Up to 6 samples per run |
| Digestion Vessels | Ceramic crucibles (standardized, pre-weighed) |
| Reagent Handling | Fully automated acid/alkali/enzyme dosing and temperature-controlled digestion |
| Compliance | AOAC 978.10, AOAC 985.29, AACC 32-05, ISO 6865, EN ISO 13906 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fibertec™ 1023 |
| Application Principle | Enzymatic-gravimetric method per AOAC 991.43, AOAC 2009.01, AACC 32–07, NMKL 158, and ASP methods |
| Sample Capacity | 12 samples per digestion batch, 6 samples per filtration batch |
| Digestion Vessel Volume | 600 mL |
| Water Bath Temperature Range | Ambient to 80 °C |
| Temperature Accuracy | ±0.1 °C |
| Oscillation Speed | 0–150 cycles/min |
| Oscillation Amplitude | 0–50 mm |
| Filtration Throughput | 2–4 min per 100 mL digested slurry |
| Reproducibility | RSD < 0.5% for total dietary fiber (TDF) across replicate analyses |
| Compliance | Fully aligned with AOAC Official Methods of Analysis®, ISO 13905:2014, and USP <2040> for dietary fiber quantification |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fossomatic 7 |
| Automation Level | Fully Automatic |
| Analysis Speed | Up to 600 samples/hour |
| Detection Range | 0–10 × 10⁶ cells/mL |
| Repeatability | CV < 4% at 500,000 cells/mL |
| Accuracy | < 10% deviation vs. direct microscopic count |
| Technology | Flow Cytometry |
| Compliance | ISO 13366-1, IDF 148, FDA/NCIMS Grade A Standards |
| Software Platform | Foss Integrator NOVA |
| Sample Types | Bovine, ovine, caprine, and buffalo milk |
| Configuration Options | Fossomatic 7 (total SCC) and Fossomatic 7 DC (somatic cell differential counting) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatMaster II |
| Technology | X-ray Transmission |
| Sample Types | Raw, chilled, or frozen meat (bone-in or boneless |
| Detection Parameters | Fat content, mass, foreign object detection (metal, bone) |
| Compliance | Designed for food processing environments meeting EU Hygiene Regulation (EC) No. 852/2004, HACCP principles, and compatible with GMP/GLP-aligned QA workflows |
| Brand | FOSS |
|---|---|
| Country of Origin | Denmark |
| Model | MilkoScan FT3 |
| Detection Parameters | Fat, Protein, Lactose, Total Solids, Non-Fat Solids, Freezing Point, Titration Acidity, Density, Free Fatty Acids, Citric Acid, Casein, Urea, Sucrose, Glucose, Fructose, Galactose |
| Automation Level | Fully Automatic |
| Analysis Time | 30 seconds per sample |
| Precision (CV) | < 0.25% (Fat, Protein, Lactose), < 0.20% (Total Solids), < 1 m°C (Freezing Point) |
| Sample Volume | < 8.0 mL |
| Flow System | Fully Automated Cleaning & Zeroing with Adaptive Adjustment |
| Connectivity | LIMS, FossManager™ Software |
| Dimensions | 750 × 450 × 408 mm |
| Weight | 43 kg |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Milkoscan Mars |
| Automation | Fully Automatic |
| Analysis Time | 1 min per sample |
| Measurement Parameters | Fat, Protein, Lactose, Total Solids, Non-Fat Solids |
| Repeatability | ≤0.5% CV (for raw milk major components) |
| Accuracy | ≤1.2% CV (for raw milk major components) |
| Technology | Fourier Transform Infrared (FTIR) Spectroscopy |
| Compliance | Designed for ISO 9001–certified dairy QA/QC environments |
| Screening Capability | Pre-installed ASM (Adulterant Screening Module) models for urea, sucrose, formaldehyde, sodium bicarbonate, potassium nitrate, and other common adulterants |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MilkoScan™ FT2 |
| Automation | Fully Automatic |
| Analysis Time | 30 s |
| Sample Volume Range | 4–25 mL |
| Repeatability | <0.2% CV (for fat, protein, lactose, total solids, SNF in raw milk) |
| Accuracy | <0.8% CV (for fat, protein, lactose, total solids, SNF in raw milk) |
| Operating Temperature Range | 5–55 °C |
| Carry-over | <1% |
| Optical System | Sealed, temperature-controlled FTIR interferometer |
| Calibration Methods | Intercept/slope adjustment |
| Supported Chemometric Models | PLS, modified PLS, PCA |
| Compliance | CE-marked |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MycoFoss |
| Detection Principle | Bead-based Flow Cytometric Immunoassay |
| Sample Throughput | Up to 12 samples per run |
| Assay Time | ≤8 minutes per sample |
| Target Analytes | Aflatoxins (AFB1, AFB2, AFG1, AFG2), Deoxynivalenol (DON), Zearalenone (ZEA), Ochratoxin A (OTA), T-2 Toxin, Fumonisins (FB1, FB2, FB3) |
| Sample Types | Ground corn, wheat, and barley |
| Automation Level | Fully automated sample preparation, assay execution, and data reporting |
| Compliance Support | Audit-trail enabled, 21 CFR Part 11–ready software architecture, GLP/GMP-aligned workflow design |
| Data Management | Integrated instrument control, result traceability, PDF report generation, and CSV export |