| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-2000 Universal |
| Application Scope | General-Purpose Analytical Chemistry |
| Control Interface | Full-Touch Color LCD Display |
| Pneumatic Control | Electronic Pressure and Flow Control (EPC) |
| Software Architecture | Modular Workstation with Method-Driven Workflow |
| Microfluidic Capability | Valveless Flow Switching for Column Back-Flush, Detector Selection, and GC-MS Parallel Operation |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | SA-50 |
| Instrument Type | Ultra-High Performance Liquid Chromatography–Atomic Fluorescence Spectrometry System |
| Application Scope | Elemental Speciation Analysis |
| Configuration | Modular, Integrated LC Pump(s), Dual-Column Oven, Column Switching Valve, UV Photochemical Reactor with Auto-Activation, Four-Channel Peristaltic Pump, LED Status Indicators, Optional Autosampler (96-/120-position) |
| Software | Unified Control Platform for Total Element and Speciation Quantification, Method Management, Hybrid Sequence Scheduling, Real-Time Instrument Monitoring, System Self-Diagnosis, Customizable Reporting Templates |
| Compliance Framework | Designed to support GLP/GMP-aligned workflows |
| Brand | EXPEC / Hangzhou Superspectra Technology Co., Ltd. |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | EXPEC 2000 (Spec. 112) |
| Instrument Type | Laboratory-Scale Gas Chromatograph with Online Monitoring Capability |
| Detection Principle | GC-FID (Gas Chromatography with Flame Ionization Detection) |
| Sample Introduction | Cryogenic Preconcentration + Thermal Desorption for TNMHC |
| Compliance | Technical Specification for Continuous Automatic Monitoring of Ambient Air TNMHC (Trial Version), China National Environmental Monitoring Centre, January 2021 |
| Installation Form | Wall-Mounted Enclosure |
| Onboard Gas Generation | Integrated Hydrogen Generator (for Carrier and Fuel Gas) |
| Detection Limit | ≤20 ppb (as Carbon) |
| Regulatory Alignment | ASTM D6348, ISO 11890-2, US EPA Method 25A, HJ 1012–2018 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Portable Gas Chromatograph |
| Application Scope | General-purpose Environmental Emission Monitoring |
| Compliance Standards | HJ 1012, HJ 38, HJ 604, GB 37822–2019 |
| Detection Principle | High-Temperature Heated Sample Transfer + Flame Ionization Detection (FID) |
| Detection Limit | Sub-ppb Level for Total Hydrocarbons, Methane, and BTEX |
| Integrated Power Supply | Rechargeable Lithium Battery (≥4 h continuous operation with heated line) |
| Data Output | Raw Chromatograms & Quantitative Results Exportable in Standard Formats (e.g., .csv, .cdf) |
| Certification | China Metrology Accreditation (CPA), Compatible with CMA Reporting Requirements |
| Sample Introduction | Dual-Stage Filtered Sampling Pump + Fixed-Volume Loop Injection |
| Column Configuration | Capillary GC Column Optimized for C1–C8 Hydrocarbons |
| Detector Temperature | Up to 180 °C |
| Sample Line Temperature | Heated to 180 °C |
| Dimensions & Portability | Integrated All-in-One Chassis with Carrying Handle |
| Optional Accessories | Android Tablet Interface, High-Pressure Gas Cylinders, Metal Hydride Hydrogen Generators |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Pressure Range | Up to 70 MPa |
| Column Compatibility | Supports 2 µm particle-packed columns |
| Flow Pulsation | <10 psi (PPRC technology) |
| Column Oven Capacity | Accommodates up to six 250 mm columns simultaneously |
| Temperature Uniformity | ±0.1 °C (forced-air circulation + high-precision PID control) |
| Autosampler Wash | Dual-needle displacement cleaning mechanism |
| Data Acquisition Rate | Up to 100 Hz |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP, GMP |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | GC 2000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Electronic Pressure Control (EPC) | Up to 6 modules, controlling up to 18 gas channels |
| EPC Precision | 0.001 psi |
| Sample Path Surface Treatment | Ultra-inert deactivation for N/O/S/P-containing compounds |
| Operating System | Android-based open platform with touch interface |
| Software | Legacy-compatible workstation with sequence/method editing, real-time chromatogram display, multi-sample statistical comparison and trend visualization |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 3100 |
| Instrument Type | Portable Gas Chromatograph with Flame Ionization and Photoionization Detectors |
| Compliance | GB 37822–2019, HJ 733–2014, HJ 1019–2019 |
| Weight | 3.7 kg |
| Response Time | < 3.5 s (FID/PID) |
| Detector Options | FID (standard), PID (optional) |
| Explosion Protection | Intrinsically Safe (handheld controller), Flameproof (FID module), Certified for Class I, Division 1 hazardous locations |
| Brand | EXPEC/Spectrum Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 3200 |
| Instrument Type | Portable Gas Chromatograph |
| Detection Principle | High-Temperature Catalytic Oxidation + Flame Ionization Detection (FID) |
| Detection Limit | Sub-ppb Level for THC/Methane/NMHC |
| Compliance | HJ 1012–2018, Local NMHC Field Monitoring Standards (Beijing, Tianjin, Shandong, Fujian, Jiangxi, Henan) |
| Brand | EXPEC / Spectrometer Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 2000 |
| Instrument Type | Online Gas Chromatograph |
| Detection Principle | GC-FID (Direct Method) |
| Sampling Method | Cryogenic Pre-concentration + Thermal Desorption |
| Sample Line Temperature | 120 °C (Heated Line) |
| Compliance | “Technical Specification for Continuous Automatic Monitoring of Non-Methane Hydrocarbons in Ambient Air (Trial)” (CNEMC-Air-2021-61) |
| Safety Features | Automatic H₂ Cut-off upon FID Flame-Out |
| Gas Control | Electronic Pressure Control (EPC) & Electronic Flow Control (EFC) |
| Surface Treatment | Deactivated (Inertized) Gas Pathways |
| Sample Handling | Back-Flush Function to Prevent High-Boiling Residue Carryover |
| Brand | EXPEC / Puyu Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | EXPEC 2000 |
| Instrument Type | Online Gas Chromatograph |
| Detection Methods | UV Fluorescence (H₂S), Chemiluminescence (NH₃), GC-NPD (methylamine, dimethylamine, trimethylamine), GC-FPD (methanethiol, methyl sulfide, carbon disulfide, dimethyl disulfide), GC-FID (styrene) |
| Detection Limit | As low as 0.1 ppb for selected compounds |
| Cabinet Format | 19-inch standard rack-mount enclosure |
| Compliance | Aligned with GB 14554–2018 (Draft Revision), HJ 1227–2021, and related Chinese environmental monitoring standards |
| Brand | EXPEC / Superspec |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | EXPEC 2000 |
| Instrument Type | Online Gas Chromatograph |
| Detection Configurability | FID, MSD, or PID Detectors |
| Target Analytes | Methane / NMHC, BTEX, Methanol, Acetone, and >100 Volatile Organic Compounds |
| Sampling Line Material | Stainless Steel or PTFE Low-Adsorption Tubing |
| Software Interface | Localized Chinese GUI with Audit-Trail-Capable Control Platform |
| Footprint | ≥1 m² (Modular Cabinet Design, Indoor/Outdoor Deployment Options) |
| Compliance | GB/T 38394–2019, HJ 1012–2018, HJ 759–2015 |
| Brand | EXPEC (Hangzhou Supeltech Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online Gas Chromatograph with FID |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Preconcentration Method | Cryogenic Trapping & Direct Thermal Desorption |
| Sample Handling | Automated Whole-Air Sampling with Integrated Dehumidification and Enrichment |
| Compliance Context | Designed for continuous unattended operation in ambient air monitoring networks compliant with EPA TO-14/TO-15, ISO 16017-1, and China HJ 644–2013 standards |
| Software | Embedded real-time control with audit-trail-capable data acquisition supporting 21 CFR Part 11–compatible user authentication and electronic signatures |
| Brand | EXPEC Technology |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 2000 |
| Detection Principle | Dual-detector Gas Chromatography (FID + ECD) |
| Target Analytes | CO₂, CH₄, CO, N₂O, SF₆ |
| Compliance | GB/T 31705–2015 |
| Sample Introduction | Quantitative Loop Injection |
| Separation | Dedicated GHG Capillary Column |
| CO/CO₂ Conversion | Ni-Catalyzed Methanizer at Elevated Temperature |
| Detector Configuration | Simultaneous FID (for CH₄, CO-derived CH₄) and ECD (for N₂O, SF₆) |
| Data Output | Continuous Real-Time Concentration Profiles (ppb–ppm range) |
| Operational Mode | Unattended 24/7 Online Monitoring |
| Brand | EXPEC (Supelco Technology) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online Gas Chromatograph with Flame Ionization Detection (GC-FID) |
| Configuration | Full-Heat Trace Sampling System with Integrated Pre-treatment Unit, H₂ Generator, and Zero Air Generator |
| Compliance | Aligned with EPA Method TO-15 / Method 18 and HJ 1012–2018 (China) |
| Design | Intrinsically Safe and Explosion-Proof Options Available |
| Sample Interface | High-Temperature Heated Probe (up to 200 °C), PTFE or Passivated Metal Sampling Line |
| Data Output | Real-time Modbus TCP / OPC UA / 4–20 mA to DCS/SCADA and Environmental Supervision Platforms |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online Gas Chromatograph |
| Detection Principle | GC-FID (Gas Chromatography with Flame Ionization Detection) |
| Explosion Protection | Ex d e ib px IIC T3/T4 Gb |
| Core Detector | Explosion-Proof FID |
| Sampling Method | High-Temperature Heated Probe + Heated Sample Line + Heated Pre-treatment Unit |
| Data Output | Real-time Temperature, Pressure, Flow Rate, Humidity, O₂ Content, NMHC, Benzene, Toluene, Ethylbenzene, Xylenes (BTEX) |
| Compliance | Designed for EPA Method 25A / ISO 12039 / HJ 1012-2018 Environments |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Operating Ambient | –10 °C to +50 °C |
| Enclosure Rating | IP65 |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 3050 |
| Instrument Type | Portable Gas Chromatograph with Integrated FID |
| Weight | ~2.0 kg |
| Compliance | GB 37822–2019, HJ 733–2014, HJ 1019–2019 |
| Optional Configuration | FID + PID dual-detector mode |
| Power Supply | Rechargeable Li-ion battery (operational runtime ≥ 4 h) |
| Detection Principle | Catalytic combustion-assisted flame ionization detection |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product | Yes |
| Model | FAAS 8000ICS |
| Pricing | Upon Request |
| Brand | EXPEC / Puyu Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | EXPEC 2000 (Specification 113) |
| Instrument Type | Online Gas Chromatograph |
| Certifications | Ex d IIB T4 Gb (IEC/EN 60079-1), IP66 |
| Detection Principle | Flame Ionization Detection (FID) |
| Sample Interface | Direct high-flow sampling with heated sample line (180 °C) |
| Response Time (T₉₀) | ≤2 s |
| Operating Environment | Zone 1 hazardous area (ATEX/IECEx compliant) |
| Installation Mode | Outdoor wall-mounted, no analyzer shelter required |
| Compliance | GB/T 16157–1996, HJ 38–2017, HJ 1012–2018 |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 6800 |
| Detection Principle | Suppressed Conductivity Detection with Electrolytic Regeneration |
| Column Compatibility | Capillary- and Micro-bore Format (≤0.4 mm ID) |
| Eluent Generation | On-line Electrolytic Eluent Generator (“Water-Only” Mode) |
| Temperature Control | Dual-stage Full-Flowpath Thermal Management (−10 °C to 45 °C ambient operating range) |
| Suppressor Type | Continuous Electrolytic Regenerative Membrane Suppressor |
| Data Acquisition | Integrated Industrial PC with Touchscreen + External Chromatography Workstation (Windows-based, FDA 21 CFR Part 11 compliant modules available) |
| Compliance | ASTM D4327, ISO 14911, USP <645>, EPA Methods 300.0, 317.0, 321.8 |