| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HMA-2000 |
| Instrument Type | Online Analytical System |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Pb, Cd, As, or Hg (configurable per unit) |
| Zero Drift | ±5% F.S. |
| Accuracy/Precision | ±10% |
| Resolution | 0.0001 mg/L |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 6010 |
| Quotation | Upon Request |
| Instrument Type | Online Analyzer |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Target Elements | Multi-Element (e.g., As, Cd, Cr, Cu, Ni, Pb, Zn, Hg, Mn, Fe, Al, etc.) |
| Compliance Standard | HJ 776–2015 “Determination of 32 Elements in Water by ICP-OES” |
| Automation Level | Fully Automated (Sampling, Filtration, Pre-treatment, Analysis, QC, Data Acquisition & Transmission) |
| Detection Range | Sub-ppb to ppm (full dynamic range) |
| Measurement Cycle | < 5 minutes per sample (multi-element simultaneous analysis) |
| Interference Resistance | Immune to color, turbidity, and matrix-induced spectral overlap under optimized plasma conditions |
| Waste Generation | Minimal reagent consumption |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Model | HMA-2000 Series |
| Instrument Type | Online Analyzer |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Lead (Pb), Cadmium (Cd) |
| Detection Time | Zero Drift (24 h): ±5% F.S. |
| Resolution | 0.0001 mg/L |
| Sample Throughput | Continuous online operation with programmable measurement intervals |
| Reagent Consumption | <20% of conventional flow-injection ASV systems |
| Digestion | Sealed high-temperature high-pressure digestion module (up to 180 °C, 2 MPa) |
| Compliance | Designed for ISO 17294-2, EPA Method 200.8, and ASTM D3559–22 compatibility |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | SUPEC 5100 ICP-OES |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Instrument Type | Online Analyzer |
| Target Elements | Thallium (Tl), Antimony (Sb), and other regulated heavy metals in water |
| Compliance Basis | Aligns with laboratory-standard methods per ISO 17294-2, EPA Method 200.7, and GB/T 3049–2022 |
| Automation Level | Fully automated sample introduction, digestion (if integrated), nebulization, plasma excitation, spectral acquisition, background correction, QC calibration, data validation, and remote telemetry |