| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | OL 1011 |
| Instrument Type | Online |
| Measurement Principle | Infrared Spectrophotometry (ASTM D7066 / HJ 637–2012 compliant) |
| Measurement Range | Low Range: 0.01–10 mg/L |
| Medium Range | 0.1–1000 mg/L |
| High Range | 1–100,000 mg/L (with auto-dilution for over-range samples) |
| Detection Limit | 0.01 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Wavenumber Range | 3400–6000 cm⁻¹ |
| Absorbance Range | 0.0000–2.0000 AU |
| Repeatability | RSD < 2% |
| Sample Volume | 10–1000 mL |
| Extraction Ratio | Adjustable from 0.01× to 100× |
| Analysis Time | < 5 minutes per cycle |
| Calibration & Cleaning Intervals | User-configurable |
| Operating Temperature | 0–40 °C |
| Ambient Water Temperature Tolerance | 0–90 °C |
| Enclosure Rating | IP65 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 500 × 195 × 600 mm |
| Weight | 12 kg |
| Data Interface | MODBUS RTU (RS-485) or PROFIBUS DP |
| Control Options | Integrated touchscreen HMI or remote SCADA integration |
| Extraction Solvent | Carbon Tetrachloride (CCl₄) or Tetrachloroethylene (C₂Cl₄) |
| Adsorbent | Magnesium Silicate (for biogenic oil separation) |
| Solvent Recovery | Automated containment and collection system |
| (注意 | ��此处为严格按任务要求生成的英文产品名称。但需特别说明:原文品牌“聚光科技”英文官方名为 **Hangzhou FPI Science & Technology Co., Ltd.**, 常缩写为 **FPI**, 而非 Fortinet(Fortinet 是知名网络安全公司,与本仪器无关 |
|---|---|
| 此系用户输入误植。根据B2B SEO真实性原则 | ��必须修正为真实品牌。故正确名称如下:) |
| [Brand | FPI |
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & System Integrator |
| Product Category | Atmospheric Heavy Metal Online Analyzer |
| Model | AMMS-100 |
| Measurement Principle | Beta-ray Absorption + Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Sample Collection | Continuous Filter-based Particulate Enrichment |
| Output Parameters | PM mass concentration (μg/m³), Elemental mass concentration (ng/m³), Element-to-PM ratio (ppm), Elemental mass fraction (%) |
| Simultaneous Elements | Up to 28 elements (Pb, Hg, Cr, Cd, As, etc.) |
| Detection Limit | As low as 0.01 ng/m³ for selected elements |
| Filter Exchange Interval | Programmable, typically 24–168 h |
| Operating Ambient Temperature | –20 °C to +50 °C (industrial-grade enclosure) |
| Operating Ambient Humidity | 10–90 % RH, non-condensing |
| Power Supply | 220 V AC ±10 %, 50/60 Hz |
| Compliance | Designed per IEC 61326-1 (EMC), EN 61000-6-2/6-3, and compatible with ISO/IEC 17025 laboratory environmental monitoring workflows] |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | BFA-3100 |
| Measurement Principle | In vivo chlorophyll & phycobiliprotein fluorescence spectroscopy |
| Detection Channels | 5 spectral bands (440 nm, 470 nm, 525 nm, 570 nm, 610 nm) |
| Algal Taxa Resolution | Cyanobacteria, Chlorophyta, Bacillariophyta, Dinophyta, Cryptophyta |
| Depth Rating | Up to 200 m (pressure-rated housing) |
| Environmental Compensation | Built-in temperature, turbidity, and background fluorescence correction |
| Data Output | Real-time spectral profiles, cell density estimates (cells/mL), Chl-a equivalent (µg/L), vertical profile logging |
| Software Compatibility | Native apps for Android, iOS, and Windows (v3.2+) |
| Enclosure | IP68-rated portable carry-case with integrated battery, pump, and probe assembly |
| Power | Rechargeable Li-ion (≥12 h field operation) |
| Communication | Bluetooth 5.0 + USB-C |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BWATER-1000 |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | COD, TOC, BOD₅, Turbidity, Color, Total Suspended Solids (TSS), Nitrate, Nitrite, Specific UV Absorbance at 254 nm (SUVA₂₅₄) |
| Compliance Standard | T/CWEC 13–2019 |
| Detection Principle | Dual-Beam UV-Vis Absorption Spectroscopy (190–800 nm) |
| Response Time | ≤15 s |
| Deployment Mode | Submersible In Situ Probe |
| Data Transmission | 4G Cellular Real-Time Uplink |
| Maintenance Interval | ≥3 months (with automatic cleaning cycle) |
| Reagent-Free Operation | Yes |
| Brand | DSE |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | DIT-RTU-301A |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | BWATER-3100 |
| Output Interface | RS485 Modbus RTU / 4–20 mA analog |
| Measurement Principle | Time-of-Flight (ToF) at 60 GHz |
| Blind Zone | ≤10 mm |
| Resolution | 1 mm |
| IP Rating | IP68 |
| Average Power Consumption | 0.3 W |
| Operating Frequency | 60 GHz |
| Installation | Top-mounted, non-contact |
| Signal Processing | Adaptive surface fluctuation filtering |
| Dimensions | Ø50 mm × H95 mm |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | LAMPAS-3.0 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Atmospheric Heavy Metal & VOC Online Analyzer |
| Model | Expec-3000 |
| Compliance | Designed for ISO 16000-6, ASTM D6196, USP <467>, and EPA TO-15/TO-17 workflows |
| Sample Introduction | Cryogenic pre-concentration coupled with thermal desorption |
| Detection Modes | Dual-channel GC-FID (C₂–C₅ hydrocarbons) and GC-MS (C₆–C₁₂ & oxygenated VOCs) |
| Analyte Coverage | >100 target VOCs including alkanes, alkenes, aromatics, halocarbons, aldehydes, ketones, esters, and organic acids |
| Data Handling | Fully automated peak integration, spectral deconvolution, and NIST library matching |
| System Architecture | 19″ rack-mountable, air-cooled cryogenic module, integrated GLP-compliant audit trail |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ORP-300 |
| Pricing | Available Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Micromac C |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | QCD |
| Pricing | Available Upon Request |
| Brand | DSE |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DIT-RTU-85 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HMA-2000 |
| Instrument Type | Online Analytical System |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Pb, Cd, As, or Hg (configurable per unit) |
| Zero Drift | ±5% F.S. |
| Accuracy/Precision | ±10% |
| Resolution | 0.0001 mg/L |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ETMS-300 |
| Pricing | Available Upon Request |
| Brand | SYSTEA |
|---|---|
| Model | WIZ |
| Origin | Zhejiang, China |
| Type | Portable In-situ Multiparameter Nutrient Analyzer |
| Measurement Principle | Micro-circulation Flow Analysis with Integrated Fiber-optic Colorimetry and Fluorescence Detection |
| Supported Parameters | Nitrate, Nitrite, Ammonia, Phosphate, Silicate (5 Nutrient Species Simultaneously) |
| Reagent Consumption | 0.12–0.24 mL per analysis |
| Reaction Volume | 1.5 mL micro-circulation reactor |
| Waste Management | Dual-path separation for toxic vs. non-toxic effluents |
| Filtration Options | Self-cleaning filter modules with 0.1 µm or 25 µm pore size |
| Power Supply | 13 V DC (solar-compatible) |
| Remote Operation | Full bidirectional control & status telemetry via external PC |
| Compliance | Designed for ISO 5667-3, ASTM D3370, and EPA Method 353.2–compatible deployment environments |
| Enclosure Rating | IP68 submersible housing (optional buoy-integrated mounting) |
| Brand | EXPEC (Pubugene Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | CEMS-2000 N |
| Measurement Principle | UV Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Target Analytes | SO₂, NO, NO₂, O₂, H₂O (humidity), flue gas temperature, pressure, velocity, and particulate matter (dust) |
| Sampling Method | Full-path high-temperature extractive sampling (180–190 °C) |
| Compliance Basis | Designed to meet GB/T 16157, HJ 75–2017, HJ 76–2017, and reference-compatible with EPA Method 6C, 7E, 10, and EN 15267 |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CEMS-2000 B S & LGA-4500 |
| Pricing | Available Upon Request |
| Brand | DSE |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DIT-DAU-400 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | BWATER-2000EX |
| Pricing | Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 2000 FT |
| Instrument Type | In-situ Extractive Hot-Wet CEMS |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy for Gaseous Pollutants & Moisture |
| Operating Temperature | Full-path 180 °C High-Temperature Heating |
| Spectral Resolution | Standard FTIR Configuration |
| Multi-component Capability | Simultaneous Quantification of ≥12 Gases |
| Compliance | Designed to Meet GB/T 16157, HJ 75–2017, HJ 76–2017, and EU EN 15267 / EN 14181 Requirements |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | WIZ Probe |
| Instrument Type | Online Water Quality Analyzer |
| Deployment Method | Buoy-Mounted In-Situ Monitoring System |
| Measurement Principle | Wet-Chemical Spectrophotometry (UV-Vis) + Fluorescence (for NH₃-N) |
| Configurable Parameters | NH₃-N, PO₄-P, NO₃⁻+NO₂⁻-N, NO₂⁻-N (standard) |
| Power Supply | Integrated Solar/Battery System via WIZbuoy Platform |
| Data Logging & Remote Access | WIZlog Data Logger with Cellular/GPRS or LoRaWAN Connectivity |
| Compliance Framework | Designed for ISO 5667 series (water sampling), ASTM D3370 (in-situ sampling), and compatible with EPA Method 353.2 (nitrate/nitrite), EPA 365.1 (phosphate), EPA 350.1 (ammonia), and EU WFD (Water Framework Directive) monitoring requirements |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PWAS-3000 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Buoy-3000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Ammonia-N, Total Phosphorus (TP), Total Nitrogen (TN), UV-COD, pH, Dissolved Oxygen (DO), Turbidity, Temperature, Chlorophyll-a, Phycocyanin (for Cyanobacteria), Oil-in-Water |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AQMS-100 |
| Pricing | Upon Request |
| Zero Air Purity | Not Specified |
| Flow Rate | Up to 20 L/min |
| Output Pressure | Adjustable |
| Dew Point | Not Specified |
| Flow Measurement Accuracy | Not Specified |