- All
- Favorite
- Popular
- Most rated
| (注意 | ��此处为严格按任务要求生成的英文产品名称。但需特别说明:原文品牌“聚光科技”英文官方名为 **Hangzhou FPI Science & Technology Co., Ltd.**, 常缩写为 **FPI**, 而非 Fortinet(Fortinet 是知名网络安全公司,与本仪器无关 |
|---|---|
| 此系用户输入误植。根据B2B SEO真实性原则 | ��必须修正为真实品牌。故正确名称如下:) |
| [Brand | FPI |
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & System Integrator |
| Product Category | Atmospheric Heavy Metal Online Analyzer |
| Model | AMMS-100 |
| Measurement Principle | Beta-ray Absorption + Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Sample Collection | Continuous Filter-based Particulate Enrichment |
| Output Parameters | PM mass concentration (μg/m³), Elemental mass concentration (ng/m³), Element-to-PM ratio (ppm), Elemental mass fraction (%) |
| Simultaneous Elements | Up to 28 elements (Pb, Hg, Cr, Cd, As, etc.) |
| Detection Limit | As low as 0.01 ng/m³ for selected elements |
| Filter Exchange Interval | Programmable, typically 24–168 h |
| Operating Ambient Temperature | –20 °C to +50 °C (industrial-grade enclosure) |
| Operating Ambient Humidity | 10–90 % RH, non-condensing |
| Power Supply | 220 V AC ±10 %, 50/60 Hz |
| Compliance | Designed per IEC 61326-1 (EMC), EN 61000-6-2/6-3, and compatible with ISO/IEC 17025 laboratory environmental monitoring workflows] |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Atmospheric Heavy Metal & VOC Online Analyzer |
| Model | Expec-3000 |
| Compliance | Designed for ISO 16000-6, ASTM D6196, USP <467>, and EPA TO-15/TO-17 workflows |
| Sample Introduction | Cryogenic pre-concentration coupled with thermal desorption |
| Detection Modes | Dual-channel GC-FID (C₂–C₅ hydrocarbons) and GC-MS (C₆–C₁₂ & oxygenated VOCs) |
| Analyte Coverage | >100 target VOCs including alkanes, alkenes, aromatics, halocarbons, aldehydes, ketones, esters, and organic acids |
| Data Handling | Fully automated peak integration, spectral deconvolution, and NIST library matching |
| System Architecture | 19″ rack-mountable, air-cooled cryogenic module, integrated GLP-compliant audit trail |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CEMS-2000 B S & LGA-4500 |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 2000 FT |
| Instrument Type | In-situ Extractive Hot-Wet CEMS |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy for Gaseous Pollutants & Moisture |
| Operating Temperature | Full-path 180 °C High-Temperature Heating |
| Spectral Resolution | Standard FTIR Configuration |
| Multi-component Capability | Simultaneous Quantification of ≥12 Gases |
| Compliance | Designed to Meet GB/T 16157, HJ 75–2017, HJ 76–2017, and EU EN 15267 / EN 14181 Requirements |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AQMS-100 |
| Pricing | Upon Request |
| Zero Air Purity | Not Specified |
| Flow Rate | Up to 20 L/min |
| Output Pressure | Adjustable |
| Dew Point | Not Specified |
| Flow Measurement Accuracy | Not Specified |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CMS odor 1000 |
| Detection Principle | Gas Chromatography–Ion Mobility Spectrometry (GC-IMS) |
| Instrument Type | Online Analytical System |
| Typical Configuration | Multi-Compound VOC & Odorant Analyzer |
| Regulatory Compliance | GB 14554–201X, DB31/1025–2016, DB12/059–2018 (22 regulated odorants, qualitative & quantitative) |
| Detection Limit | Sub-ppt (parts-per-quadrillion) for key sulfur/nitrogen compounds |
| Resolution | 100 (IMS drift time resolution, FWHM) |
| Accuracy | ≤10% RSD (relative standard deviation) for calibrated odorants |
| Response Time | ≤10 s (IMS-only mode) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | FPI DS7000 Series |
| Safety Rating | Explosion-Proof (Class I, Division 1, Groups C/D |
| Measurement Principle | Electrostatic Induction Sensing |
| Compliance | CE, RoHS, GB/T 18204.1–2013 (China), IEC 60079-0:2017, IEC 60079-1:2014 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000B |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±0.5% FS/24h (Span Drift) |
| Response Time | ≤ 200 s |
| Stability | ≤ ±1% FS/24h (Zero Drift) |
| Measured Parameters | Gaseous Pollutants (SO₂, NO, NO₂, CO, CO₂, O₂), Particulate Matter (PM), Temperature, Pressure, Flow Velocity, Humidity |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | BPM-200 |
| Measurement Principle | Beta-Ray Attenuation Method (β-ray) |
| Safety Rating | Explosion-Proof (Class I, Division 1, Group A–D compliant per UL 1203 / IEC 60079-0) |
| Sampling Flow Rate | 16.7 L/min (standardized per ISO 10473 and EPA PM2.5 Reference Method EQPM-0805-190) |
| Particle Size Cuts | TSP, PM₁₀, PM₂.₅ (interchangeable impactors) |
| Compliance | Meets technical requirements of HJ 653–2013 (China), EN 12341:2014, and compatible with US EPA Federal Equivalent Method (FEM) framework for continuous ambient PM monitoring |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AQMS-600 |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Model | PFS-100 |
| Type | Online Multicomponent Photolysis Rate Analyzer |
| Measurement Principle | Actinic Flux-Based Spectral Radiometry |
| Optical Path | Quartz Collector + UV-VIS Optical Fiber Coupling |
| Detector | Thermoelectrically Cooled CCD Array |
| Spectral Range | 280–450 nm (configurable) |
| Spectral Resolution | ≤0.5 nm (FWHM) |
| Calibration Traceability | NIST-traceable actinic flux calibration |
| Data Output | Real-time J-value time series (s⁻¹) for O¹D, NO₂, OH, HONO, HCHO, and other photolabile species |
| Compliance | Designed per ISO 17025 laboratory practice guidelines |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Extractive FTIR |
| Configuration | Online Continuous Monitoring System |
| Optical Resolution | 1 cm⁻¹ |
| Effective Path Length | Adjustable from 10 m to 64 m |
| Detector Operating Temperature | −196 °C (Liquid Nitrogen Cooled MCT) |
| Detection Limit | Sub-ppb for Selected Analytes |
| Spectral Library | >300 Certified Reference Spectra (Developed with Anhui Institute of Optics and Fine Mechanics, CAS |
| Simultaneous Quantification | ≥20 Gaseous Species (e.g., VOCs, CO, CO₂, NH₃, SO₂, NO, HCl, HF, CH₄) |
| Interference Compensation | Multi-point Calibration + Multi-spectral Band Fitting Algorithm |
| Sample Handling | Direct Extractive Sampling — No Pre-concentration or Chemical Derivatization Required |
| Compliance Readiness | Designed for ASTM D6348, ISO 12039, EPA Method 320, and GLP/GMP-aligned Data Integrity Frameworks |
| Software Architecture | Supports 21 CFR Part 11 Audit Trail, Electronic Signatures, and Secure Data Export (CSV, XML, PDF) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Instrument Type | Online Aerosol Organic Carbon/Elemental Carbon Analyzer |
| Measurement Principle | Thermal-Optical Transmittance (TOT) or Thermal-Optical Reflectance (TOR) |
| Compliance | Designed for ASTM D7520, IMPROVE_A, NIOSH 5040-compatible protocols |
| Sample Inlet | Standard PM2.5 or PM10 inlet with heated line (optional) |
| Detection Method | Laser transmittance/reflectance monitoring during thermal desorption |
| Flow Control | Proportional solenoid valves + mass flow controllers (MFCs) |
| Furnace Construction | High-purity alumina ceramic furnace bricks with ceramic fiber-insulated heating elements |
| OC/EC Split Point Determination | Automated optical carbon charring correction algorithm |
| Brand | EXPEC (Pubetech) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Mobile Atmospheric Monitoring Vehicle |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 VOC |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measured Parameters | Methane / Non-Methane Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes), Target VOC Species, Particulate Matter (PM) Concentration, Flue Gas Temperature, Pressure, and Velocity |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WAGA |
| Configuration | Online Continuous Monitoring System |
| Measurement Principle | Wet-Chemical Extraction Coupled with Ion Chromatography (IC) |
| Instrument Type | Online Multicomponent Aerosol Ion Analyzer |
| Compliance | Designed for ambient air quality monitoring per Chinese HJ 653–2013 and compatible with ISO 12884, EN 14902, and US EPA OTM-33A method frameworks |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PMS-200M |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Ambient Air Sampler |
| Instrument Architecture | Multi-Channel Sequential Gas & Aerosol Sampler |
| Flow Range | Customizable (Typical Standard Range: 16.7–100 L/min per Channel) |
| Pressure Drop Handling | Up to 25 kPa (at max flow) |
| Flow Stability | ±2% over 24 h (with active feedback control) |
| Flowmeter Accuracy | ±1.5% of reading (NIST-traceable thermal mass flow sensors) |
| Rated Service Life at Max Load | ≥12,000 operating hours |
| Continuous Operation Duration at Max Flow & Backpressure | ≥24 h per cycle |
| Brand | Lingxi Optoelectronics |
|---|---|
| Origin | Zhejiang, China |
| Model | HGA-331 |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Detection Gases | CO₂, CH₄, H₂O (simultaneous) |
| Sensitivity | < 1 ppb (for CO₂ and CH₄) |
| Compliance | WMO Global Atmosphere Watch (GAW) Performance Specifications |
| Temperature & Pressure Control | Integrated active thermal and barometric stabilization |
| Output | Dry-mole-fraction concentrations (H₂O-corrected) |
| Data Logging | Internal storage + Ethernet/RS-232/USB interfaces |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PMS-200 |
| Configuration | Dual-Channel Integrated Sampler |
| Flow Rate | Single-Channel: 16.67 L/min |
| Dual-Channel | 15 L/min (PM₂.₅) and 16.67 L/min (PM₁₀–PM₂.₅) |
| Vacuum Pressure Range | 80–106 kPa |
| Flow Stability | ≤2% of setpoint over 24 h |
| Maximum Flow Accuracy | ±2% of setpoint |
| Continuous Operation at Max Flow & Backpressure | 24 h |
| Service Life Under Max Load & Resistance | 2–3 years |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000 B FT |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Accuracy | ≤ ±2% of Full Scale (F.S.) |
| Repeatability / Span Drift | ≤ ±2% F.S. over 7 days |
| Response Time | ≤ 180 s |
| Zero Drift | ≤ ±2% F.S. over 7 days |
| Operating Temperature | Sample Path Heated to 180 °C |
| Interferometer | Patented ROCKSOLID™ Dynamic Alignment-Free Design |
| Calibration | Automated Zero and Span Calibration |
| Compliance | Designed for EPA Method 320, ISO 12039, EN 15267-3, and applicable EU IED & US Clean Air Act requirements |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AMMS-100 |
| Pricing | Available Upon Request |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 3500 Plus |
| Instrument Type | Portable |
| Detection Principle | Gas Chromatography–Mass Spectrometry (GC-MS) and Direct Electron Ionization Mass Spectrometry (EI-MS) |
| Configuration | Dual-Channel Integrated VOCs Analyzer |
| Compliance | Designed for field-deployable environmental monitoring per ISO 16000-6, ASTM D6196, and EPA Method TO-15/TO-17 frameworks |
| Sample Introduction | Real-time direct inlet + automated thermal desorption GC-MS module |
| Brand | EXPEC (Pubichem) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TRACE 8000 |
| Instrument Type | Online VOC Analyzer |
| Ion Source | Dual-Anode Hollow Cathode Lamp with H₂O Reagent Ion Chemistry |
| Mass Analyzer | Vertical-Entry Reflectron Time-of-Flight (TOF) |
| Detection Mode | Soft Chemical Ionization (PCI) via H₃O⁺ Transfer |
| Typical LOD | <100 pptv (sub-ppb) for C₂–C₁₀ VOCs |
| Operating Mode | Unattended Continuous Monitoring |
| Compliance Framework | Designed for ISO 16000-22, ASTM D6196-20, and EPA Method TO-15/TO-17 compatible workflows |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 B |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Response Time | 4 s |
| Measured Parameters | SO₂, NO, O₂, Relative Humidity, Flue Gas Temperature, Static Pressure, Flow Velocity, Particulate Matter (PM) |
| Detection Principle | NDIR (SO₂, CO), UV Absorption (NO), Electrochemical Cell (O₂), Capacitive/Hygrometric (Humidity), PT100/Thermocouple (Temperature), Piezoresistive (Pressure), Pitot Tube or Ultrasonic (Flow Velocity), Light Scattering / Beta Attenuation (PM) |
| Communication Interface | RS485, 4–20 mA, Ethernet, Modbus TCP/RTU, OPC UA |
| Compliance | GB/T 16157, HJ 75–2017, HJ 76–2017, ISO 12039, EN 15267, EN 14181 |
Show next