Fortune Science & Technology (Hangzhou) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelOL 1011
Instrument TypeOnline
Measurement PrincipleInfrared Spectrophotometry (ASTM D7066 / HJ 637–2012 compliant)
Measurement RangeLow Range: 0.01–10 mg/L
Medium Range0.1–1000 mg/L
High Range1–100,000 mg/L (with auto-dilution for over-range samples)
Detection Limit0.01 mg/L
Accuracy±2% of reading
Resolution0.001 mg/L
Wavenumber Range3400–6000 cm⁻¹
Absorbance Range0.0000–2.0000 AU
RepeatabilityRSD < 2%
Sample Volume10–1000 mL
Extraction RatioAdjustable from 0.01× to 100×
Analysis Time< 5 minutes per cycle
Calibration & Cleaning IntervalsUser-configurable
Operating Temperature0–40 °C
Ambient Water Temperature Tolerance0–90 °C
Enclosure RatingIP65
Power Supply220 V ±10%, 50 Hz
Dimensions500 × 195 × 600 mm
Weight12 kg
Data InterfaceMODBUS RTU (RS-485) or PROFIBUS DP
Control OptionsIntegrated touchscreen HMI or remote SCADA integration
Extraction SolventCarbon Tetrachloride (CCl₄) or Tetrachloroethylene (C₂Cl₄)
AdsorbentMagnesium Silicate (for biogenic oil separation)
Solvent RecoveryAutomated containment and collection system
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelOL1010
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (Based on ASTM D7066 & HJ 637–2012)
Measurement Range0–50,000 mg/L
Detection Limit0.005 mg/L
Accuracy±2%
Resolution0.001 mg/L
Wavenumber Range3400–6000 cm⁻¹
Absorbance Range0.0000–2.0000 AU
Sample Volume20–1000 mL (with OL-101 Auto-Sampler)
Extraction RatioAdjustable (0.01–100)
Analysis Time<5 min (with OL-101 Auto-Sampler)
RepeatabilityRSD <2%
ComplianceHJ 637–2012, HJ/T 91–2002, ASTM D7066, ISO 9377-2
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelOL 1020
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (ASTM D7066, HJ 637–2012)
Measurement Range0–50,000 mg/L (with automatic dilution for over-range samples)
Detection Limit0.005 mg/L
Accuracy±2% of reading
Resolution0.001 mg/L
Wavenumber Range3,400–6,000 cm⁻¹
Absorbance Range0.0000–2.0000 AU
Sample ThroughputUp to 10 samples per batch
Sample Volume10–1,000 mL
Extraction SolventsTetrachloroethylene or Carbon Tetrachloride
Extraction Ratio Programmable0.01–100
Measurement Time per Sample<5 minutes
ComplianceHJ 637–2012, HJ/T 91–2002, ISO 9377-2:2000 (Water Quality — Determination of Hydrocarbon Oil Index)