| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CEMS-2000 B S & LGA-4500 |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 2000 FT |
| Instrument Type | In-situ Extractive Hot-Wet CEMS |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy for Gaseous Pollutants & Moisture |
| Operating Temperature | Full-path 180 °C High-Temperature Heating |
| Spectral Resolution | Standard FTIR Configuration |
| Multi-component Capability | Simultaneous Quantification of ≥12 Gases |
| Compliance | Designed to Meet GB/T 16157, HJ 75–2017, HJ 76–2017, and EU EN 15267 / EN 14181 Requirements |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000B |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±0.5% FS/24h (Span Drift) |
| Response Time | ≤ 200 s |
| Stability | ≤ ±1% FS/24h (Zero Drift) |
| Measured Parameters | Gaseous Pollutants (SO₂, NO, NO₂, CO, CO₂, O₂), Particulate Matter (PM), Temperature, Pressure, Flow Velocity, Humidity |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 VOC |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measured Parameters | Methane / Non-Methane Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes), Target VOC Species, Particulate Matter (PM) Concentration, Flue Gas Temperature, Pressure, and Velocity |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000 B FT |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Accuracy | ≤ ±2% of Full Scale (F.S.) |
| Repeatability / Span Drift | ≤ ±2% F.S. over 7 days |
| Response Time | ≤ 180 s |
| Zero Drift | ≤ ±2% F.S. over 7 days |
| Operating Temperature | Sample Path Heated to 180 °C |
| Interferometer | Patented ROCKSOLID™ Dynamic Alignment-Free Design |
| Calibration | Automated Zero and Span Calibration |
| Compliance | Designed for EPA Method 320, ISO 12039, EN 15267-3, and applicable EU IED & US Clean Air Act requirements |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 B |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Response Time | 4 s |
| Measured Parameters | SO₂, NO, O₂, Relative Humidity, Flue Gas Temperature, Static Pressure, Flow Velocity, Particulate Matter (PM) |
| Detection Principle | NDIR (SO₂, CO), UV Absorption (NO), Electrochemical Cell (O₂), Capacitive/Hygrometric (Humidity), PT100/Thermocouple (Temperature), Piezoresistive (Pressure), Pitot Tube or Ultrasonic (Flow Velocity), Light Scattering / Beta Attenuation (PM) |
| Communication Interface | RS485, 4–20 mA, Ethernet, Modbus TCP/RTU, OPC UA |
| Compliance | GB/T 16157, HJ 75–2017, HJ 76–2017, ISO 12039, EN 15267, EN 14181 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ±2% F.S. for ranges ≤100 mg/m³ |
| Repeatability | Span drift ≤±2% F.S./24 h |
| Response Time | ≤180 s (with heated sampling line ≤70 m) |
| Stability | Zero drift ≤±2% F.S./24 h |
| Measured Parameters | Gaseous pollutants (SO₂, NOₓ, O₂, CO, CO₂), particulate matter (PM), flue gas temperature, pressure, velocity, and humidity |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 D |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measured Parameters | SO₂, NOₓ (NO + NO₂), O₂, H₂O (wet-basis) |
| Analytical Methods | Ultraviolet Fluorescence (SO₂), Chemiluminescence (NOₓ), Capacitive Humidity Sensing (H₂O), Zirconia Electrochemical Cell (O₂) |
| System Architecture | Dilution-extractive sampling with integrated calibration, data acquisition, and communication modules |
| Compliance Framework | Designed to support compliance with GB/T 16157, HJ 75–2017, HJ 76–2017, and compatible with EPA Method 6C / 7E / 3A / 4 for reference equivalence |
| Brand | EXPEC (Spectrum Technologies) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CEMS-2000 B FT |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Linearity Error | ≤ ±2% F.S. |
| Drift (Span) | ≤ ±2% F.S. / 7 days |
| Response Time | ≤ 180 s (with 50 m heated sampling line) |
| Zero Drift | ≤ ±2% F.S. / 7 days |
| Measured Gases | SO₂, NO, NO₂, NOₓ, NH₃, HCl, HF, CO, CO₂, O₂, H₂O |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LDM-100 |
| Instrument Type | In-Situ Optical Transmissometer for Particulate Emissions Monitoring |
| Extinction Accuracy | ±0.004 |
| Repeatability | ≤2% |
| Response Time | 1–600 s (configurable) |
| Stability | Transmittance/Turbidity ±1% |
| Compliance | Meets GB/T 16157, HJ 76–2017, and HJ 836–2017 requirements for fixed-source emission monitoring |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Methane / NMHC Online Analyzer |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Thermal Design | Full-Stream 175 °C High-Temperature Heating |
| Column Configuration | Dual-Valve Dual-Column (Model 115) / Dual-Valve Triple-Column (Model 120) |
| Analysis Cycle Time | <90 s per cycle |
| Target Analytes | CH₄, Total NMHC, Benzene, Toluene, Xylenes (BTX) |
| Safety Feature | Auto-H₂ shutoff upon FID flameout |
| Compliance Basis | Aligned with HJ 38–2017, HJ 1012–2018, EPA Method 25A, ASTM D6420 |