| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | OL 1011 |
| Instrument Type | Online |
| Measurement Principle | Infrared Spectrophotometry (ASTM D7066 / HJ 637–2012 compliant) |
| Measurement Range | Low Range: 0.01–10 mg/L |
| Medium Range | 0.1–1000 mg/L |
| High Range | 1–100,000 mg/L (with auto-dilution for over-range samples) |
| Detection Limit | 0.01 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Wavenumber Range | 3400–6000 cm⁻¹ |
| Absorbance Range | 0.0000–2.0000 AU |
| Repeatability | RSD < 2% |
| Sample Volume | 10–1000 mL |
| Extraction Ratio | Adjustable from 0.01× to 100× |
| Analysis Time | < 5 minutes per cycle |
| Calibration & Cleaning Intervals | User-configurable |
| Operating Temperature | 0–40 °C |
| Ambient Water Temperature Tolerance | 0–90 °C |
| Enclosure Rating | IP65 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 500 × 195 × 600 mm |
| Weight | 12 kg |
| Data Interface | MODBUS RTU (RS-485) or PROFIBUS DP |
| Control Options | Integrated touchscreen HMI or remote SCADA integration |
| Extraction Solvent | Carbon Tetrachloride (CCl₄) or Tetrachloroethylene (C₂Cl₄) |
| Adsorbent | Magnesium Silicate (for biogenic oil separation) |
| Solvent Recovery | Automated containment and collection system |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BWATER-1000 |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | COD, TOC, BOD₅, Turbidity, Color, Total Suspended Solids (TSS), Nitrate, Nitrite, Specific UV Absorbance at 254 nm (SUVA₂₅₄) |
| Compliance Standard | T/CWEC 13–2019 |
| Detection Principle | Dual-Beam UV-Vis Absorption Spectroscopy (190–800 nm) |
| Response Time | ≤15 s |
| Deployment Mode | Submersible In Situ Probe |
| Data Transmission | 4G Cellular Real-Time Uplink |
| Maintenance Interval | ≥3 months (with automatic cleaning cycle) |
| Reagent-Free Operation | Yes |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | BWATER-3100 |
| Output Interface | RS485 Modbus RTU / 4–20 mA analog |
| Measurement Principle | Time-of-Flight (ToF) at 60 GHz |
| Blind Zone | ≤10 mm |
| Resolution | 1 mm |
| IP Rating | IP68 |
| Average Power Consumption | 0.3 W |
| Operating Frequency | 60 GHz |
| Installation | Top-mounted, non-contact |
| Signal Processing | Adaptive surface fluctuation filtering |
| Dimensions | Ø50 mm × H95 mm |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Micromac C |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | QCD |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HMA-2000 |
| Instrument Type | Online Analytical System |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Pb, Cd, As, or Hg (configurable per unit) |
| Zero Drift | ±5% F.S. |
| Accuracy/Precision | ±10% |
| Resolution | 0.0001 mg/L |
| Brand | SYSTEA |
|---|---|
| Model | WIZ |
| Origin | Zhejiang, China |
| Type | Portable In-situ Multiparameter Nutrient Analyzer |
| Measurement Principle | Micro-circulation Flow Analysis with Integrated Fiber-optic Colorimetry and Fluorescence Detection |
| Supported Parameters | Nitrate, Nitrite, Ammonia, Phosphate, Silicate (5 Nutrient Species Simultaneously) |
| Reagent Consumption | 0.12–0.24 mL per analysis |
| Reaction Volume | 1.5 mL micro-circulation reactor |
| Waste Management | Dual-path separation for toxic vs. non-toxic effluents |
| Filtration Options | Self-cleaning filter modules with 0.1 µm or 25 µm pore size |
| Power Supply | 13 V DC (solar-compatible) |
| Remote Operation | Full bidirectional control & status telemetry via external PC |
| Compliance | Designed for ISO 5667-3, ASTM D3370, and EPA Method 353.2–compatible deployment environments |
| Enclosure Rating | IP68 submersible housing (optional buoy-integrated mounting) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | BWATER-2000EX |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | WIZ Probe |
| Instrument Type | Online Water Quality Analyzer |
| Deployment Method | Buoy-Mounted In-Situ Monitoring System |
| Measurement Principle | Wet-Chemical Spectrophotometry (UV-Vis) + Fluorescence (for NH₃-N) |
| Configurable Parameters | NH₃-N, PO₄-P, NO₃⁻+NO₂⁻-N, NO₂⁻-N (standard) |
| Power Supply | Integrated Solar/Battery System via WIZbuoy Platform |
| Data Logging & Remote Access | WIZlog Data Logger with Cellular/GPRS or LoRaWAN Connectivity |
| Compliance Framework | Designed for ISO 5667 series (water sampling), ASTM D3370 (in-situ sampling), and compatible with EPA Method 353.2 (nitrate/nitrite), EPA 365.1 (phosphate), EPA 350.1 (ammonia), and EU WFD (Water Framework Directive) monitoring requirements |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PWAS-3000 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Buoy-3000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Ammonia-N, Total Phosphorus (TP), Total Nitrogen (TN), UV-COD, pH, Dissolved Oxygen (DO), Turbidity, Temperature, Chlorophyll-a, Phycocyanin (for Cyanobacteria), Oil-in-Water |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | SIA-3000 Series |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Nitrogen (TN), Total Phosphorus (TP), Ammonia-Nitrogen (NH₃-N), Permanganate Index (CODₘₙ), Chemical Oxygen Demand (COD) |
| Regulatory Compliance | HJ 636, GB 11893, HJ 536, GB 11892, HJ 828 |
| Sample Matrix | Surface Water, Drinking Water, Municipal Wastewater, Industrial Process Water, Effluent from Pollution Sources |
| Measurement Modes | Continuous, Cyclic, Manual, Remote-Triggered |
| Calibration & Maintenance | Automated Cyclic Cleaning and Standard Calibration |
| Flow Architecture | Sequential Injection Analysis (SIA) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MICROMAC C Series |
| Instrument Type | Online Water Quality Analyzer |
| Detection Principle | Colorimetric Analysis with Microprocessor Control |
| Analytical Technology | Loop Flow Analysis (LFA) |
| Key Feature | Auto-Dilution Function for Over-Range Measurement |
| Compliance Framework | Designed for Continuous Emission Monitoring Systems (CEMS) and Industrial Effluent Monitoring Applications |
| Software Interface | RS485/Modbus RTU, Optional 4–20 mA Analog Output |
| Enclosure Rating | IP65 |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 5000 COD |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | COD-2000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Oxidation–Spectrophotometric Method |
| Measurement Range | 0–200 / 0–500 / 0–2000 mg/L COD |
| Accuracy | ≤ ±10% of reading |
| Repeatability | ≤ 3% RSD |
| Limit of Detection | 10 mg/L COD |
| Zero Drift (24 h) | ±5 mg/L |
| Maintenance Interval | Up to 30 days without service intervention |
| Reagent Consumption | <10%–20% of conventional segmented flow systems |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China (Distributed) |
| Model | SYSTEA Micromac C |
| Measurement Principles | Colorimetric Spectrophotometry (UV-Vis) |
| Analytes | Nitrate-N, Nitrite-N, Ammonia-N, Orthophosphate, Silicate, Sulfate, Total Phosphorus, Total Nitrogen |
| Detection Method | Batch-type Flow-Through Cell with LED-based Photometric Detection |
| Operating Modes | Manual, Cyclic, Triggered, Continuous |
| Communication Interfaces | RS232, RS485, 4–20 mA analog output |
| Optional | Ethernet interface, Pre-treatment module, Dual-waste separation (toxic/non-toxic), Leak detection sensor, Reagent level monitoring |
| Compliance Support | Designed for continuous unattended operation in GLP-aligned environmental monitoring labs |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | OL1010 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Absorption Spectrophotometry (Based on ASTM D7066 & HJ 637–2012) |
| Measurement Range | 0–50,000 mg/L |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Wavenumber Range | 3400–6000 cm⁻¹ |
| Absorbance Range | 0.0000–2.0000 AU |
| Sample Volume | 20–1000 mL (with OL-101 Auto-Sampler) |
| Extraction Ratio | Adjustable (0.01–100) |
| Analysis Time | <5 min (with OL-101 Auto-Sampler) |
| Repeatability | RSD <2% |
| Compliance | HJ 637–2012, HJ/T 91–2002, ASTM D7066, ISO 9377-2 |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 5000 TPTN |
| Application | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Instrument Type | Laboratory-Based Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) with Potassium Persulfate Digestion |
| Compliance Standards | GB 11893, HJ 636, National Surface Water Monitoring Guidelines |
| Safety Features | 9-layer pressure vessel safety protection, automated lid actuation, 120 °C precision temperature control |
| Automation Level | Full walk-away operation from sample loading to report generation |
| Sample Throughput | Batch processing with customizable multi-tube sample trays |
| Reagent Delivery | Independent parallel multi-channel injection system |
| Detection System | Dual-wavelength UV-Vis spectrophotometric detection module |
| Robotic Platform | High-precision articulated robotic arm with cup-position recognition |
| Brand | EXPEC |
|---|---|
| Model | CHL-300 |
| Measurement Principle | In-situ Fluorescence Detection |
| Output Interface | RS-485 with Modbus RTU Protocol |
| Cleaning Mechanism | Integrated Motorized Brush |
| Power Management | Low-Power Embedded Architecture |
| Environmental Rating | IP68 Submersible Housing |
| Deployment Mode | Continuous Online Monitoring |
| Sample Type | Natural Freshwater, Estuarine, and Marine Waters |
| Compliance | Designed for ASTM D7912-17 (Standard Test Method for Chlorophyll a in Water by Fluorometric Determination) and ISO 10260:2021 (Water Quality — Determination of Chlorophyll a — Fluorometric Method) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BWATER4100 |
| Instrument Type | Online Multi-parameter Water Quality Analyzer |
| Measured Parameters | Ammonia Nitrogen (NH₃-N), Total Phosphorus (TP) |
| Enclosure Rating | IP68 |
| Power Supply | Battery or Solar Compatible |
| Reagent Replacement Interval | Up to 6 Weeks |
| Sample Reaction Volume | <3 mL |
| Digestion Method | UV Irradiation + High-Temperature Thermal Digestion |
| Typical Analysis Time per Parameter | <30 minutes |
| Compliance | GB/T 7479–2023 (NH₃-N), GB/T 11893–1989 (TP), ISO 15681-2:2022 (Phosphorus), ASTM D1426–22 (Ammonia) |
| Brand | SYSTEA |
|---|---|
| Model | EasyColi |
| Measurement Principle | Standard Enzyme-Substrate Method (MPN, P/A, TTD) |
| Compliance | HJ 1001-2018, ISO 9308-1:2014 |
| Detection Limit | 1 MPN/100 mL |
| Upper Detection Range | >20,000 MPN/100 mL |
| Sample Throughput | 28 fully automated MPN tests per cycle |
| Sample Independence | Individual incubation chambers per sample |
| Integrated Cleaning Station | Yes |
| Regulatory Support | GLP-compliant data logging, audit trail enabled |
| Software Interface | Touchscreen GUI with real-time assay progress visualization |
| Application Scope | Surface water, drinking water, groundwater, recreational bathing waters, municipal wastewater, industrial effluents |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | VOC-3000 |
| Pricing | Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTEA Micromac C |
| Pricing | Upon Request |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | BFA-3000 |
| Application Mode | Portable & Online Dual-Mode |
| Depth Rating | Up to 200 m submersible |
| Measurement Principle | In vivo chlorophyll a fluorescence excitation with multi-wavelength LED array |
| Compliance | Designed for field-deployable water quality monitoring per ISO 10260, ASTM D3731, and EPA Method 445.0 (Chlorophyll a by in vivo fluorescence) |
| Data Output | Real-time spectral fluorescence response, taxonomic group quantification (e.g., Cyanobacteria, Diatoms, Green Algae, Cryptophytes), Chl-a concentration (µg/L), and vertical profile logging |
Show next