Empowering Scientific Discovery

Fortune Science & Technology (Hangzhou) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFPI
OriginZhejiang, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelBWATER-3100
Output InterfaceRS485 Modbus RTU / 4–20 mA analog
Measurement PrincipleTime-of-Flight (ToF) at 60 GHz
Blind Zone≤10 mm
Resolution1 mm
IP RatingIP68
Average Power Consumption0.3 W
Operating Frequency60 GHz
InstallationTop-mounted, non-contact
Signal ProcessingAdaptive surface fluctuation filtering
DimensionsØ50 mm × H95 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelMicromac C
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
ModelWIZ
OriginZhejiang, China
TypePortable In-situ Multiparameter Nutrient Analyzer
Measurement PrincipleMicro-circulation Flow Analysis with Integrated Fiber-optic Colorimetry and Fluorescence Detection
Supported ParametersNitrate, Nitrite, Ammonia, Phosphate, Silicate (5 Nutrient Species Simultaneously)
Reagent Consumption0.12–0.24 mL per analysis
Reaction Volume1.5 mL micro-circulation reactor
Waste ManagementDual-path separation for toxic vs. non-toxic effluents
Filtration OptionsSelf-cleaning filter modules with 0.1 µm or 25 µm pore size
Power Supply13 V DC (solar-compatible)
Remote OperationFull bidirectional control & status telemetry via external PC
ComplianceDesigned for ISO 5667-3, ASTM D3370, and EPA Method 353.2–compatible deployment environments
Enclosure RatingIP68 submersible housing (optional buoy-integrated mounting)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFPI
OriginZhejiang, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM/ODM)
Country of OriginChina
ModelBWATER-2000EX
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEXPEC
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPWAS-3000
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
OriginZhejiang, China (Distributed)
ModelSYSTEA Micromac C
Measurement PrinciplesColorimetric Spectrophotometry (UV-Vis)
AnalytesNitrate-N, Nitrite-N, Ammonia-N, Orthophosphate, Silicate, Sulfate, Total Phosphorus, Total Nitrogen
Detection MethodBatch-type Flow-Through Cell with LED-based Photometric Detection
Operating ModesManual, Cyclic, Triggered, Continuous
Communication InterfacesRS232, RS485, 4–20 mA analog output
OptionalEthernet interface, Pre-treatment module, Dual-waste separation (toxic/non-toxic), Leak detection sensor, Reagent level monitoring
Compliance SupportDesigned for continuous unattended operation in GLP-aligned environmental monitoring labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
ModelEasyColi
Measurement PrincipleStandard Enzyme-Substrate Method (MPN, P/A, TTD)
ComplianceHJ 1001-2018, ISO 9308-1:2014
Detection Limit1 MPN/100 mL
Upper Detection Range>20,000 MPN/100 mL
Sample Throughput28 fully automated MPN tests per cycle
Sample IndependenceIndividual incubation chambers per sample
Integrated Cleaning StationYes
Regulatory SupportGLP-compliant data logging, audit trail enabled
Software InterfaceTouchscreen GUI with real-time assay progress visualization
Application ScopeSurface water, drinking water, groundwater, recreational bathing waters, municipal wastewater, industrial effluents
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSYSTEA Micromac C
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
OriginZhejiang, China
ModelEasyTox Pro
Measurement PrincipleBioluminescent Bacterial Assay (Aliivibrio fischeri)
Quantification OutputEC₅₀ (Half-Maximal Effective Concentration)
Analysis PlatformAutomated Discrete Analyzer with Robotic Arm
Sample ThroughputDual-channel simultaneous analysis
Reaction Vessel Capacity80-position rotating cuvette carousel
Signal Acquisition Interval60 s
Assay Duration2.5–30 min per sample
Bacterial RehydrationFully automated lyophilized culture reactivation
Operational AutonomyUp to 90 days unattended (with refrigerated reagent/culture storage)
Regulatory ComplianceISO 11348-3:2007 and GB/T 15441–1995 methods programmable
Data IntegrityAudit-trail-enabled software compliant with GLP/GMP documentation requirements
Refrigerated Storage CompartmentDedicated 4 °C zone for lyophilized bacteria, controls, and reagents
Cross-Contamination ControlIntegrated cleaning station with sequential rinse/flush protocols
QC FeaturesReal-time bioluminescence viability monitoring, dual parallel blank/sample measurement, automatic result validation logic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEXPEC (Hangzhou Puyu Technology Co., Ltd.)
ModelFIA-3000
Measurement PrincipleDPD Colorimetric Method (ASTM D1253, ISO 7393-2, EPA 330.5)
Wavelength510 nm
Detection RangeFree Chlorine: 0.01–5.00 mg/L Cl₂
Total Chlorine0.02–5.00 mg/L Cl₂
Detection Limit≤0.01 mg/L (Free Cl₂), ≤0.02 mg/L (Total Cl₂)
Sample pH AdjustmentAutomatic buffering to pH 6.2–6.5
CatalystIodide-mediated oxidation for total chlorine conversion
Optical SystemLED-based photometer with dual-beam compensation
Enclosure RatingIP65
Installation OptionsWall-mounted or benchtop configuration
Reagent Consumption<1.2 mL per analysis cycle
Waste SeparationIntegrated reagent/waste fluid segregation
ComplianceDesigned for GLP/GMP-aligned operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEXPEC
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSUPEC 5010
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
ModelLabTox
Measurement PrincipleBioluminescent Bacterial Toxicity Assay (using *Aliivibrio fischeri*, *Photobacterium phosphoreum*, or *Vibrio qinghaiensis* Q67)
ComplianceISO 11348-3, GB/T 15441
ThroughputUp to 30 samples/hour
Sample Capacity80-position carousel
Dilution RangeUp to 160-fold automated serial dilution (EC50 mode)
Dual-Parallel TestingBlank + sample replicates (inhibition mode)
Integrated Cleaning StationOn-board probe and cuvette washing with programmable rinse cycles
SoftwareWindows-based control & analysis suite with audit trail, user management, and data export (CSV, PDF, Excel)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
OriginZhejiang, China
ModelNWP
Measurement Parameters5-parameter simultaneous in-situ analysis (e.g., NO₃⁻-N, PO₄³⁻, NH₄⁺-N, SiO₂, CODₘₙ or configurable)
Detection Limit0.001 mg/L (for key analytes)
CalibrationTwo-point linear calibration (R² ≥ 0.995)
Power Supply13 V DC (solar-compatible)
Filtration OptionsSelf-cleaning filter cartridges (0.1 µm or 25 µm)
Waste HandlingSegregated toxic/non-toxic waste and effluent lines
Sample WashDeionized water–free cleaning using ambient sample water
Remote OperationFull bidirectional control & real-time status telemetry via external PC
Environmental RatingIP68 submersible housing for buoy, vessel, or emergency field deployment
ComplianceDesigned to support ISO 5667-3, ASTM D511/D512/D5429/D6508, and EPA Method 300.0/353.2 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
ModelEasyTox
Measurement PrincipleBioluminescence Inhibition Assay using Marine Luminescent Bacteria (Aliivibrio fischeri, Vibrio qinghaiensis sp.-Q67, or Photobacterium phosphoreum)
ComplianceISO 11348-3, GB/T 15441
Detection ModeQualitative (Inhibition Rate %) and Quantitative (EC₅₀)
Dilution RangeUp to 160× automated dilution
Measurement Interval60 s per sample cycle
Bacterial Culture Maintenance Interval7–14 days
Reagent & Control StorageIntegrated 4–8 °C refrigerated compartment
Cross-Contamination ControlDedicated cleaning station with multi-stage rinse protocol
User InterfaceProgrammable touchscreen HMI with full workflow automation
Sample TypesSurface water, drinking water, groundwater, municipal wastewater, industrial effluent, seawater
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEXPEC
OriginZhejiang, China
ModelWOT-3100
ApplicationOrganic Contaminant Source Identification via Fluorescence Excitation-Emission Matrix (EEM) Fingerprinting
Detection PrincipleUV-Vis Fluorescence Spectroscopy (200–450 nm excitation
Operational ModeReagent-Free, Non-Destructive Optical Analysis
Deployment FlexibilityBenchtop, Mobile (Vehicle/Boat-Mounted), Field-Deployable
Data Integration CapabilityCompatible with Heavy Metal Analyzers and Organic Pollutant Sensors for Multi-Parameter Emergency Response
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelEasyChem
PricingAvailable Upon Request
TechnologyDiscrete Batch Analysis with MPN, P/A, and TTD Detection Methods
ComplianceISO 9308-2:2012 (Colilert-based), ASTM D6501, US EPA Method 1604 (adapted)
Sample ThroughputUp to 28 MPN tests or 56 P/A–TTD tests per unattended cycle
Reagent CompatibilityColilert®-18/Colilert®-EC, Enterolert®, and other ISO-validated media
Sample IndependenceFully isolated incubation wells per sample
Integrated Cleaning StationAutomated reagent/sample line flushing and well decontamination
Control Interface7-inch industrial touchscreen with programmable assay sequences
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
ModelSmarTox
Measurement PrincipleBioluminescence Inhibition Assay (using *Aliivibrio fischeri*, *Photobacterium phosphoreum*, or *Vibrio qinghaiensis* Q67)
Temperature ControlRefrigerated Reagent Compartment (4–8 °C) & Thermostatic Reaction Chamber (15–25 °C)
Detection Interval30 s per measurement
Data Storage Capacity>1,000 test records
Power SupplyRechargeable 12.6 V / 11,000 mAh Li-ion battery
ComplianceISO 11348-3, GB/T 15441
DisplayIndustrial-grade color LCD touchscreen with guided workflow interface
OutputIntegrated thermal printer for on-site report generation
ConnectivityUSB data export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSYSTEA
OriginZhejiang, China
ModelEasyTox Max
Detection PrincipleBioluminescent Bacterial Inhibition Assay (using *Aliivibrio fischeri*, *Photobacterium phosphoreum*, or *Vibrio qinghaiensis* Q67)
Toxicity Output% Inhibition (qualitative) and EC50 (quantitative, 160× dilution capability)
Measurement FrequencyAs fast as 2.5 min/cycle
Exposure TimeProgrammable from 5 min to 24 h
ComplianceISO 11348-3, GB/T 15441
Reagent StorageIntegrated 4–8 °C refrigerated compartment
CleaningAutomated washing station with dedicated rinse cycles
Control InterfaceIndustrial-grade capacitive touchscreen with full programmability
Bacterial Maintenance Interval8–16 weeks (with on-board reactivation of lyophilized cultures)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEXPEC
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSUPEC 5100
PricingAvailable Upon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0