Gas Detector
Filter
Showing 1921–1950 of 2983 results
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | maMoS-100/200 |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Indication Error | ≤ ±5% FS |
| Repeatability | ≤ 2% RSD |
| Response Time (T90) | ≤ 45 s |
| Stability | ≤ 5% FS drift over 1 h |
| Origin | Germany |
|---|---|
| Type | Imported Instrument |
| Model | MAC100ECO |
| Manufacturer Role | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MAS-100 NT |
| Sampling Principle | Impaction-based Active Air Sampling |
| Flow Rate Range | 1–2000 L/min |
| Flow Measurement Accuracy | ±2.5% at 100 L/min |
| Total Operating Time | Approx. 5.5 h on full battery charge |
| Storage Temperature | −10°C to +50°C |
| Operating Temperature | 0°C to +40°C |
| Operating Relative Humidity | ≤80% RH (up to +31°C), linearly decreasing to ≤50% RH at +40°C, non-condensing |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MCA03 |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Extractive In-Situ Flue Gas Analyzer |
| Measurement Accuracy | ≤ ±2% of Full Scale |
| Repeatability | Not Specified |
| Response Time | ≤10 s |
| Stability | Not Specified |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB 100 |
| Flow Range (per channel) | 0–500 mL/min (standard), 0–200 mL/min (optional) |
| Accuracy | ±1.0% of setpoint (5–100% FS), ±0.2% of full scale (<5% FS) |
| Repeatability | ±0.1% of reading |
| Response Time | 50 ms per channel |
| Total Mixed Flow | Up to 1.5 L/min |
| Channels | 3 inlet, 1 outlet |
| Operating Pressure | ≤25 psi |
| Power Supply | 16–36 VDC, min. 1.5 A |
| Operating Temperature | 0–50 °C |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, C₃H₈, C₄H₁₀ (H₂ not supported) |
| Certifications | CE, TÜV, cTÜVus |
| Interface | USB PC connection, LED front-panel display |
| Software | Dedicated gas mixing control software (Windows-based), no third-party API support for GB100 variant |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB100PLUS |
| Input Channels | 3/4/6 (configurable) |
| Output Channels | 1 |
| Flow Range per Channel | 0–500 mL/min (standard) |
| optional ranges | 0–200 / 0–5,000 / 0–15,000 mL/min |
| Dilution Ratio | 1:1 to 1:1000 |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂, and other gases upon consultation |
| Third-Party Software Integration | Yes (via RS-232, RS-485, or Ethernet with Modbus RTU/TCP protocol) |
| Compliance | CE-marked |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB15K |
| Inlet Channels | 3 |
| Outlet Channels | 1 |
| Flow Range per Channel | 0–15,000 mL/min |
| Dilution Ratio | 1–1000 |
| Third-Party Software Communication | Yes |
| Compatible Gases | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂ (custom gases available upon consultation) |
| Brand | MCQ |
|---|---|
| Model | GB3000 |
| Origin | Italy |
| Configuration | 3-inlet / 1-outlet |
| Max Flow per Channel | 0–5000 mL/min |
| Dilution Ratio Range | 1:1 to 1:1000 |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂, etc. |
| Third-Party Software Integration | Yes |
| Regulatory Compliance | Designed for ISO/IEC 17025-compliant calibration labs and EPA/EN-certified environmental testing environments |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB4000 |
| Inlet Channels | 4 |
| Outlet Channels | 1 |
| Flow Range per Channel | 0–5000 mL/min |
| Dilution Ratio | 1:1 to 1:1000 |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂, and other custom gases upon request |
| Third-Party Software Integration | Yes |
| Certification | CE-marked, compliant with ISO/IEC 17025 traceability requirements for gas standard generation |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB6000 |
| Input Channels | 6 |
| Output Channels | 1 |
| Flow Range per Channel | 0–5000 mL/min |
| Dilution Ratio | 1:1 to 1:1000 |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂, and other custom gases upon consultation |
| Third-Party Software Integration | Yes |
| Certification Status | CE-marked, compliant with ISO/IEC 17025 traceability requirements for gas standard generation |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | SM-4 Mobile |
| Detection Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) with Gold Amalgamation Pre-concentration |
| Measurement Range | 0.05–100 µg/m³ (Hg⁰, Hg²⁺, Hgₚ after catalytic conversion) |
| Response Time (t₉₀) | ≤180 s |
| Sample Line Length | Up to 73 m (240 ft) |
| Dilution Ratio | Adjustable, typically 1:10 to 1:100 |
| Operating Temperature | Heated sample path up to 180 °C |
| Compliance | EPA Method 29 / ASTM D6784-22 / EN 14181 QAL1 & QAL3 certified |
| Calibration Options | Integrated NIST-traceable elemental Hg vapor generator (optional), QAL3-compliant ionized Hg⁰ calibration source (optional) |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | SM-4 Mobile |
| Measurement Principle | Thermal Catalytic Conversion + Gold Amalgamation Cold Vapor Atomic Fluorescence (CVAFS) |
| Detection Limit | 0.05 µg/m³ |
| Response Time (t₉₀) | ~180 s |
| Sample Line Length | Up to 73 m (240 ft) |
| Dilution Ratio | Adjustable, up to 1:100 |
| Compliance | EU EN 15267-3 certified, US EPA Performance Specification 12A (PS-12A) and RATA validated |
| Calibration Options | Automated Hg⁰ and Hg²⁺ gas generators (NIST-traceable), QAL3-compliant auto-validation module |
| Waste Generation | Zero liquid or solid waste |
| Operating Temperature Range | Probe heated to >180 °C |
| Filter | Heated particulate filter with automatic air-purge cleaning |
| Brand | Met One Instruments (USA) |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation |
| Range | 0–50 mg/m³ |
| Sampling Method | Impaction with Rotating Glass Impactor |
| Filter Tape | Circular, 30-sample capacity |
| Calibration | Automated zero & span drift correction using reference membrane |
| Data Storage | 182 days internal memory |
| Humidity Control | Integrated heater for RH conditioning |
| Connectivity | RS-232 serial interface |
| Compliance | EPA Reference Method for PM2.5 and PM10 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM-1020 |
| Pricing | Upon Request |
| Brand | MET ONE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Stack Emission Heavy Metal & Black Carbon Analyzer |
| Model | BC 1054 |
| Measurement Principle | Optical Absorption (Multi-Wavelength Aethalometer Principle) |
| Measurement Range | <1 ng/m³ to >100,000 ng/m³ (effective) |
| Detection Limit | 0.1 ng/m³ |
| Filter Tape Replacement Interval | 24 hours |
| Operating Temperature Range | 1–40 °C |
| Operating Relative Humidity Range | 10–90 % RH (non-condensing) |
| Operating Pressure Range | 80–106 kPa |
| Wavelengths | 370, 430, 470, 525, 565, 590, 660, 700, 880, 950 nm |
| Time Resolution | Standard 1 min |
| Sample Flow Rate | 2 or 5 L/min (user-selectable) |
| Inlet Compatibility | TSP, PM₁₀, PM₂.₅, PM₁ |
| Calibration Method | Factory-calibrated in smoke chamber against traceable NIST-traceable reference standards per ASTM D6216 and ISO 12103-1 |
| Data Output | Analog (4–20 mA), RS-232/RS-485, Ethernet (TCP/IP), Modbus RTU/TCP |
| Compliance | Designed for EPA Reference Method equivalency assessment |
| Brand | Met One |
|---|---|
| Origin | USA |
| Model | BT-610 |
| Flow Rate | 1.0 cfm (28.3 L/min) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±10% |
| Repeatability | ±5% |
| Size Channel Resolution | 0.3–10.0 µm (6 calibrated channels at 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm) |
| User-Selectable Sizing | 0.3–2.0 µm in 0.1 µm increments |
| Concentration Range | 0–3,000,000 particles/ft³ (0–105,900 particles/m³) |
| Measurement Accuracy | ±10% (per ISO 21501-4 calibration aerosol) |
| Data Storage Capacity | >8,000 sample events |
| Power | Internal 14.8 V Li-ion battery (8 h continuous / 24 h intermittent) |
| Communication Interfaces | RS-232, RS-485, USB, SD card slot |
| Analog Output | 0–5 VDC |
| Environmental Operating Range | 0–40 °C, 10–90% RH (non-condensing) |
| Dimensions (H×W×D) | 22.2 × 17.1 × 21.5 cm (3.67 kg) |
| Compliance | ISO 21501-4, ISO 14644-1, 21 CFR Part 11, CE, ISO 9001 |
| Brand | MET ONE |
|---|---|
| Origin | USA |
| Model | GT-324 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±0.0 s |
| Repeatability | ±5% |
| Size Distribution Accuracy | ±10% |
| Indication Accuracy | ±10% |
| Particle Size Channels | 0.3, 0.5, 0.7, 1.0, 2.5, 5.0, 10.0 µm (selectable 4-channel configuration) |
| Concentration Range | 0–3,000,000 particles/ft³ (0–105,900 particles/L) |
| Data Storage Capacity | 2,200 samples |
| Operating Temperature | 0–50 °C |
| Battery Life | 11 h (Li-ion, 7.2 V) |
| Charging Time | 2.5 h |
| Light Source | 780 nm laser diode, 90 mW |
| Display | 16×2 character LCD |
| Interface | Rotary encoder + membrane keypad |
| Communication | USB |
| Compliance | ISO 21501-4, FDA 21 CFR Part 11 (user access control) |
| Brand | Met One |
|---|---|
| Origin | USA |
| Model | GT-521 |
| Instrument Type | Handheld |
| Flow Rate | Low-flow (2.83 L/min) |
| Flow Accuracy | ±1% of full scale |
| Timing Accuracy | ±1 second per hour |
| Repeatability | ≤±1% RSD |
| Size Channel Resolution | Two simultaneous channels (0.3 µm and 0.5 µm) |
| Counting Efficiency | ≥50% at 0.3 µm, ≥100% at ≥0.5 µm (per ISO 21501-4) |
| Data Storage | Internal memory for up to 1,000 sample records |
| Power Supply | Rechargeable Li-ion battery (up to 8 hours continuous operation) |
| Interface | RS-232 serial output |
| Compliance | ISO 21501-4, JIS B 9921, ASTM F328 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 804 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 831 |
| Pricing | Available Upon Request |
| Brand | Met One Instruments (USA) |
|---|---|
| Origin | USA |
| Model | MetOne 804 |
| Instrument Type | Handheld |
| Flow Rate | 0.1 cfm (2.83 L/min) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±0 s |
| Repeatability | ±5% |
| Size Distribution Error | ±10% |
| Indication Error | ±10% |
| Particle Size Channels | 0.3, 0.5, 0.7, 1.0, 2.5, 5.0, 10.0 µm (user-selectable, 4 active simultaneously) |
| Concentration Limit | 1,000,000 particles/ft³ (105,900 particles/L) |
| Light Source | 780 nm laser diode, 30 mW |
| Power Supply | 7.2 V Li-ion rechargeable battery (30 h intermittent / 8 h continuous) |
| Dimensions | 9.5 × 17.2 × 5.1 cm (W × H × D) |
| Weight | 0.60 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Data Storage | 2,500 records |
| Display | 2-line × 16-character LCD |
| Interface | USB 2.0 |
| Compliance | ASTM F50, ISO 21501-4, ISO 14644-1, CE, JIS B 9921 |
| Brand | METONE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Aerocet-531 |
| Price | Upon Request |
| Brand | METONE |
|---|---|
| Country of Origin | USA |
| Model | BAM-1020 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Measured Parameters | PM₂.₅, PM₁₀, TSP (with optional inlets) |
| Measurement Range | 0–1.000 mg/m³ |
| Sampling Flow Rate | 16.7 L/min (nominal, adjustable 0–20 L/min) |
| Detection Limit | 0.1 µg/m³ (1-hour average) |
| Measurement Interval | 1 hour |
| Flow Stability | ±2% over operating range |
| EPA Certification | U.S. EPA EQPM-0607-193 (PM₂.₅), EQPM-0607-194 (PM₁₀) |
| Operating Temperature | –30°C to +50°C |
| Relative Humidity Control | Integrated heated inlet with RH stabilization <40% |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | U.S. EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Particle Size Fractions | PM₂.₅, PM₁₀, TSP |
| Measurement Range | 0–50 mg/m³ |
| Sampling Interval | Hourly |
| Data Storage Capacity | 182 days |
| RH Control | Integrated Heater with Precise Relative Humidity Management |
| Calibration | Automated Zero/Drift Checks per Cycle |
| Output Interface | RS-232 |
| Meteorological Integration | Up to 6 Sensors |
| Remote Operation Duration | Up to 60 Days Unattended |
| Compliance | EPA EQPM, UK MCERTS, Korea KEPIC, China CNAS-accredited Ambient Monitoring Applications |
| Brand | Metone |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| EPA EQPM Certification | EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Particle Size Cutoffs | PM₁₀, PM₂.₅, TSP |
| Measurement Range | 0–50 mg/m³ |
| Sampling Frequency | Hourly |
| Filter Tape | Rotating glass fiber tape (30-sample capacity) |
| RH Control | Integrated heater for dew point suppression |
| Data Storage | 182 days (internal) |
| Communication | RS-232 serial interface |
| Meteorological Inputs | Up to 6 sensors |
| Remote Operation | Unattended operation up to 60 days via web-based telemetry |
| Calibration | Automated zero/drift checks per cycle |
| Compliance | U.S. EPA EQPM, UK MCERTS, Korea KEPIC, China CNAS-accredited field deployment records |
| Operating Environment | -30°C to +50°C ambient |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10, PM2.5 |
| EPA Certification | EQPM-0798-122 (PM10 FEM), EQPM-0308-170 (PM2.5 Class III FEM) |
| Compliance | CE, NRC, TÜV, CARB, ISO 9001 |
| Range | 0–1000 µg/m³ (configurable up to 10,000 µg/m³) |
| Detection Limit | <1.0 µg/m³ (24-hr), <4.8 µg/m³ (1-hr) |
| Flow Rate | 16.7 L/min (adjustable 0–20 L/min) |
| Filter | Glass fiber tape, 30 mm × 21 m per roll |
| Beta Source | ¹⁴C, 60 µCi ±15 µCi (t₁/₂ = 5730 yr) |
| Data Storage | 182 days of hourly records |
| Operating Temp | –30 °C to +60 °C |
| RH Control | Internal heater, 10–99% RH setpoint |
| Power | 100–230 VAC, 50/60 Hz, <0.4 kW |
| Dimensions | 31 cm (H) × 43 cm (W) × 40 cm (D) |
| Weight | 24.5 kg |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Range | 0–50 mg/m³ |
| Sampling Method | Isokinetic Impactor with Rotating Glass Impactor Plate (30-sample capacity) |
| Data Output | Real-time mass concentration (µg/m³ or mg/m³), automatic zero/drift correction, event logging |
| Compliance | US EPA EQPM, UK MCERTS, Korea K-EMAS, China HJ 653-2013 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Upon Request |
| Brand | METONE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Available Upon Request |
| Brand | Metone |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Upon Request |
