Gas Detector
Filter
Showing 1951–1980 of 2983 results
| Brand | Metone |
|---|---|
| Origin | USA |
| Model | E-BAM1020 |
| Measurement Principle | Beta-ray attenuation (β-ray) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Measurement Range | 0–1.000 mg/m³ |
| Sampling Interval | 1 hour |
| Volumetric Flow Rate | 0–20 L/min |
| Detection Limit | <4.8 µg/m³ |
| Flow Stability | ±5% |
| EPA EQPM Certification | EQPM-0798-122 |
| Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53, Subpart C) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm AG (in collaboration with ECN & Applikon) |
| Model | MARGA 2S |
| Instrument Type | Online Continuous Monitor |
| Compliance | EPA ETV Verified |
| Software | MARGA Control Suite v5.x |
| Data Output | Real-time ion concentrations (µg/m³), hourly time resolution |
| Sample Streams | Simultaneous PM₂.₅, PM₁₀, gaseous HNO₃, HCl, NH₃, SO₂, HCOOH, CH₃COOH |
| Detection Principle | Wet-chemical absorption + Dual IC (Ion Chromatography) |
| Automation Level | Fully unattended operation up to 168 h |
| Remote Capability | Secure web-based monitoring, diagnostic access, and parameter control via TLS-encrypted interface |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MARS |
| Pricing | Upon Request |
| Brand | Metrohm |
|---|---|
| Model | PILS |
| Origin | Imported (Switzerland/USA) |
| Manufacturer | Metrohm AG (via Applikon BV) |
| Power Supply | 110–240 V, 50/60 Hz |
| Sampling Time | 15 min – 1 h |
| Aerosol Size Range | 0.01–10 µm |
| Liquid Collection Medium | Deionized Water |
| Compatibility | Ion Chromatography (IC), including Metrohm and third-party systems |
| Internal Standard Integration | Yes |
| Self-Cleaning Function | Yes |
| Flow Rate Limiting | 1 m³/h |
| Compliance | Designed for GLP/GMP-aligned environmental monitoring workflows |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-MEK |
| Output Options | 4–20 mA (3-wire or 4-wire), 0–5/0–10 V, RS485 (Modbus RTU), Dual Relay Outputs |
| Communication | Wired, LAN, Internet, Wireless (433 MHz, GPRS, Wi-Fi, Custom RF) |
| Remote Operation | Infrared remote control (15 m range, intrinsically safe operation without opening enclosure) |
| Calibration | Auto-zero tracking, multi-point calibration support |
| Certifications | CPA Type Approval (China), Ex d IIC T6 Gb explosion-proof certification, EMC/EMI compliant (GB/T 18268, GB/T 17626 series), Anti-static & reverse-polarity protected |
| Sensor Options | Electrochemical, Catalytic Bead, NDIR, PID, Thermal Conductivity (selectable from Honeywell, Figaro, City Technology, Alphasense, Dynament, Membrapor) |
| Brand | Millipore |
|---|---|
| Origin | Switzerland |
| Model | MAS-100 CG Ex |
| Sampling Principle | Impaction-based Active Separation |
| Flow Rates | 50 L/min and 100 L/min (selectable, constant) |
| Flow Measurement Accuracy | ±0% to +10% at 50 L/min or 100 L/min over absolute pressure range of 1.5 bar to 10 bar |
| Total Operating Time | Approx. 3.5 h per battery charge |
| Ambient Temperature Range | 0–40°C |
| Ambient Relative Humidity | Up to 80% RH at ≤31°C, linearly decreasing to 50% RH at 40°C |
| Certifications | ATEX II 2G Ex db IIB T4 Gb / II 2D Ex tb IIIC T135°C Db (for use in Zone 1 & Zone 21 hazardous areas) |
| Brand | Millipore |
|---|---|
| Origin | Switzerland |
| Model | MAS-100 ECO |
| Sampling Principle | Impaction-based Active Air Sampling |
| Flow Range | 1–1000 L/min |
| Flow Accuracy | ±4% at 100 L/min |
| Total Operating Time | Approx. 3 hours |
| Operating Temperature | 0–40 °C |
| Operating Relative Humidity | 0–80% RH (non-condensing) |
| Brand | Mingguang Lihua |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SG-1 |
| Weight | 50 g |
| Power Supply | Rechargeable Lithium Battery |
| Operating Modes | Manual & Auto (30 s cycle) |
| Continuous Operation Time | Up to 16 minutes |
| Refill Cartridge | Replaceable top-mounted cartridge containing food-grade propylene glycol and glycerol |
| Illumination | Integrated LED light for low-light visibility |
| Compliance | RoHS-compliant formulation |
| Brand | Minhope |
|---|---|
| Model | MH1200-G |
| Origin | Shandong, China |
| Instrument Type | Integrated Ambient Air Sampler for TSP, PM₁₀, PM₂.₅, Heavy Metals, Fluorides, and Semi-Volatile Organic Compounds (SVOCs) |
| Compliance | JJG 943–2011, HJ 618–2011, HJ 93–2013, HJ 691–2014 |
| Operating Modes | Instant, Timed, and Volume-Based Sampling |
| Environmental Parameter Compensation | Real-time Temperature & Barometric Pressure Measurement with Flow Correction |
| Enclosure | Weather-Resistant, Compact, Low-Noise Design |
| Power Consumption | Low |
| Weight | Lightweight for Field Deployment |
| Brand | Minhope |
|---|---|
| Model | MH3010-E |
| Construction Material | Titanium Alloy Probe Body |
| Heating Zones | Dual-Zone (Probe Tip & Filter Holder) |
| Compliance | HJ 77.2–2008, HJ/T 365–2007, GB/T 16157–1996, JJG 680–2007, JJG 968–2002 |
| Application | Isokinetic Sampling of Gas-Phase and Particulate-Bound Dioxins/Furans from Municipal Solid Waste Incinerators and Hazardous Waste Combustors |
| Operating Temperature Range | Ambient to 250 °C (adjustable, ±1 °C stability) |
| Probe Length | Standard 1.2 m (custom lengths available) |
| Filter Holder | Quartz Fiber Filter + Polyurethane Foam (PUF) Sorbent Trap |
| Pitot Tube | Rotatable, Stainless Steel, Integrated with Differential Pressure Sensor |
| Data Interface | Analog 4–20 mA outputs for temperature, velocity, and static/dynamic pressure |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA PICO ETO |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA PICO MOBILE LDS |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MGA-5 |
| Pricing | Upon Request |
| Measurement Principle | Time-Multiplexed Intermittent Continuous-Wave Quantum Cascade Laser Absorption Spectroscopy (TM-ICW-QCL) |
| Sampling Frequency | 1 Hz |
| Detection Limits (1 s) | CO: 0.4 ppb, CO₂: 0.8 ppm, CH₄: 1 ppb, N₂O: 0.5 ppb, H₂O: 40 ppm |
| Detection Limits (200 s) | CO: 0.07 ppb, CO₂: 0.08 ppm, CH₄: 0.2 ppb, N₂O: 0.1 ppb, H₂O: 6 ppm |
| Measurement Ranges | CO: 0–20 ppm, CO₂: 0–8000 ppm, CH₄: 0–200 ppm, N₂O: 0–20 ppm, H₂O: 0–10 %v/v |
| Maximum Drift (12 h) | CO: 1 ppb, CO₂: 1 ppm, CH₄: 5 ppb, N₂O: 2 ppb, H₂O: 120 ppm |
| Operating Temperature | –10 to +45 °C |
| Relative Humidity | < 90 % RH (non-condensing) |
| Pressure Range | 700–1050 mbar |
| Sample Flow Rate | 0.5–1.5 L/min (high-flow option available) |
| Power Supply | 220 VAC, 50 Hz, < 450 W |
| Dimensions (Analyzer) | 48 W × 18 H × 62 D cm |
| Weight (Analyzer) | 20 kg |
| (Cooling Unit) | 11 kg |
| (Vacuum Pump) | 9 kg |
| Safety Certifications | CE-marked per IEC 61010-1:2010, IEC 61326-1:2012, IEC 60825:2019 |
| Key | Origin: Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | ML-3100 |
| Operating Principle | Laser Backscatter Light Scattering |
| Explosion-Proof Rating | Ex d IIB T4 Gb |
| Measurement Range | 0–200 mg/m³ (low range) / 0–10 g/m³ (high range) |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1% of reading |
| Relative Error | ±2% FS |
| Operating Temperature | −40 °C to +65 °C |
| Humidity Range | 0–100% RH |
| Max Flue Gas Temp | 300 °C (customizable for higher) |
| Output Signal | 4–20 mA (max load 500 Ω) |
| Power Consumption | ≤3 W |
| Dimensions | 160 × 160 × 250 mm |
| Weight | 4 kg |
| Applicable Stack Diameter | 0.5–15 m |
| Minimum Detectable Concentration | 2 mg/m³ |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ML3600 |
| Price | USD 3,950 (FOB) |
| Measurement Principle | Laser Backscatter Photometry |
| Explosion-Proof Rating | Ex d IIB T4 Gb |
| Measurement Range | 0.01–200 mg/m³ and 0–10 g/m³ (dual-range selectable) |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1% of full scale |
| Relative Error | < ±2% |
| Operating Temperature | −40 °C to +65 °C |
| Humidity Range | 0–100% RH (non-condensing) |
| Max. Flue Gas Temp. | 300 °C (high-temp option available) |
| Output Signal | 4–20 mA (max. load 500 Ω) |
| Power Supply | DC 16–24 V ±10% |
| Power Consumption | ≤3 W |
| Dimensions | 160 × 160 × 250 mm |
| Weight | 4 kg |
| Flue Diameter Compatibility | ≥2000 mm (standard) |
| Sensitivity Threshold | 2 mg/m³ |
| Installation | Single-ended, tool-free mounting |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MCY600 |
| Operating Temperature | 5–45 °C |
| Sample Gas Pressure | up to 20 kPa (gauge) |
| Sample Flow Rate | 0.2–1.0 L/min |
| Power Supply | 12–24 VDC |
| Output Signal | 4–20 mA |
| Communication Interface | RS485 (Modbus RTU) |
| Measurement Ranges | 0–5%, 0–10%, 0–21%, 0–50%, 0–90%, 90–100%, 0–100% O₂ (v/v) |
| Linearity Error | ±2% FS |
| Stability | ±2% FS / 7 days |
| Repeatability | ±1% FS |
| Cross-Interference Resistance | NH₃, CO, CO₂, CH₄ |
| Corrosive Gas Tolerance | Yes (e.g., H₂S) |
| Sensor Type | Thermal-Magnetic Paramagnetic Detection |
| Vibration Immunity | High |
| Consumable-Free Design | Yes |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MQ701-16 / MQ701-32 Integrated Solution |
| Pricing | Available Upon Request |
| Core Components | MQ801 Vacuum Sampling Chamber, MQ701-16/MQ701-32 16-/32-Position Automated Gas Bag Injector, MODEL401 Precision Gas Dilution System |
| Compliance | Designed to meet HJ 38–2017 (China EPA Standard for Determination of Total Hydrocarbons, Methane, and NMHC in Stationary Source Exhaust) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | MTB100, MQ701-6, MQ801 |
| Pressure Rating | 1800–5000 psi (DOT-certified) |
| Bag Volumes | 0.5 L, 1 L, 3 L, 5 L, 10 L |
| Bag Material | Polyvinyl Fluoride (PVF), 0.002" thickness |
| Valve Options | Polypropylene or Stainless Steel |
| Max Operating Temperature | 204°C |
| Bag Construction | 5-layer metallized foil (MNK123557) |
| Sample Compatibility | CO, CO₂, H₂S, NH₃, SO₂, NOₓ, and other low-molecular-weight gases |
| Detection Limit Suitability | ppb-level for inert and moderately reactive species |
| VOC Range Limitation | Not recommended for sub-ppm volatile organic compound quantification |
| Injector Configuration | 6/16/32-port programmable selection valve |
| Vacuum Source | Diaphragm pump (zero-contamination design) |
| Sample Line | Silinert®-passivated, heated (anti-condensation) |
| Controller | VICI high-reliability industrial controller |
| Power Supply | Rechargeable battery (MQ801) |
| Compliance | DOT 4BA/4BW certified (MTB100), GLP-compatible operation |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | 203000 |
| Price | Upon Request |
| Operating Principle | Laser Backscatter |
| Safety Rating | Explosion-Proof |
| Measurement Range | 0–4000 mg/m³ (configurable) |
| Resolution | 0.01% of full scale |
| Accuracy | ±2% FS |
| Relative Error | <2% FS |
| Brand | Moxtek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | GasCard NG |
| Price Range | USD 2,800 – 7,000 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Measurable Gases | CO₂, CH₄, N₂O, C₆H₁₄ |
| CO₂ Range Options | 0–500 ppm, 0–5,000 ppm, or 0–100% vol |
| CH₄ Range Options | 0–5% to 0–100% vol |
| N₂O Range | 0–1,000 ppm |
| C₆H₁₄ Range | 0–2,000 ppm |
| Output Interface | RS-232, RS-485, UART, Analog (0–5 V / 4–20 mA) |
| Operating Temperature | –10 °C to +50 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Warm-up Time | < 60 s |
| Long-term Drift | < 2% FS/year |
| Calibration | Factory-calibrated |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | DELTA65S |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤±5% FS |
| Repeatability | ≤2% FS |
| Response Time | ≤90 s |
| Stability | ≤5% FS/8 h |
| Measured Parameters | O₂, CO, NO, CO₂, Flue Gas Temperature |
| O₂ Range | 0–21.00% vol |
| CO Range | 0–4000 ppm |
| CO (H₂-compensated) | 0–10000 ppm |
| NO Range | 0–5000 ppm |
| Flue Gas Temperature Range | −40 to +1100 °C |
| Dimensions | 82 × 169 × 44 mm |
| Weight | ~390 g |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | MGA6 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | NDIR (Non-Dispersive Infrared) + Electrochemical Sensors |
| Measured Gases | O₂, CO, CO₂, HC (Hydrocarbons), SO₂, NO, NO₂ |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ 2% FS |
| Response Time (T₉₀) | ≤ 20 s |
| Drift Stability | ≤ 2% FS over 24 h |
| Display | 7″ TFT Color Touchscreen (800 × 480) |
| Operating System | Embedded Linux |
| Connectivity | Bluetooth 5.0, WLAN (IEEE 802.11 b/g/n), RS485, 8-channel analog output, 4-channel analog input |
| Data Storage | Internal database with timestamped measurement logs |
| Output Formats | CSV, PDF reports |
| Compliance | EN 15267-3, EN 14181 (QAL1/QAL2), ISO 12039, ISO 10849, ASTM D6522, EPA Method 6C / 7E / 10 |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | MGA6plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | NDIR (Non-Dispersive Infrared) + Electrochemical Sensors |
| Measured Gases | O₂, CO₂, CO, NO, SO₂, NO₂, HC (C₃H₈/CH₄), N₂O |
| O₂ Sensor Options | Paramagnetic (5-year lifespan) or Electrochemical |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ 2% FS |
| Response Time (T₉₀) | ≤ 20 s |
| Long-Term Stability | ≤ 2% FS over 30 days |
| Display | 7″ TFT Color Touchscreen (800 × 480) |
| Operating System | Embedded Linux |
| Connectivity | Bluetooth 5.0, WLAN (IEEE 802.11 b/g/n), RS485, 8× analog outputs (0–10 V / 4–20 mA), 4× analog inputs |
| Data Storage | Internal database with timestamped measurement logs |
| Reporting | CSV export, PDF report generation via MRU4U software |
| Compliance | Designed for EN 15267-3, EN 14181, ISO 12039, ISO 10849, and applicable EPA Method 6C/7E/8 requirements |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | NOVAcompact |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurable Gases | O₂, CO, NO, NO₂, SO₂, COhigh, Temperature, Pressure, Flow Velocity |
| Detection Principle | Electrochemical Sensors (O₂, CO, NO, NO₂, SO₂), Thermocouple (Temperature), Piezoresistive Sensor (Pressure), Pitot Tube (Flow Velocity) |
| Operating Temperature | +5 to +45 °C |
| Storage Temperature | −20 to +50 °C |
| Power Supply | Rechargeable Li-ion Battery (10 h standard / 2–3 h with Peltier cooler) |
| Weight | ~5.8 kg |
| Dimensions (W×H×D) | 423 × 240 × 176 mm |
| Ingress Protection | IP20 |
| Data Storage | 16,000 internal records + optional 2 GB SD card |
| Connectivity | USB, Bluetooth, SD card slot |
| Compliance | Designed for EN 50379-1, EN 50379-2, and applicable parts of ISO 12039, ISO 10849, VDI 3862 |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | NOVAplus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤ ±1% FS |
| Repeatability | ≤ 1% FS |
| Response Time | ≤ 10 s |
| Stability | ≤ 1% FS over 8 h |
| Measurable Parameters | O₂, CO, NO, NO₂, SO₂, CO (high range), CO (very high range), H₂S, CO₂ (NDIR), Total Hydrocarbons (HC), Flue Gas Temperature, Differential Temperature, Combustion Air Temperature |
| Sensor Configuration | Up to 6 electrochemical cells + 3 NDIR channels |
| Battery Life | 20 h (main unit), 30 h (RCU) |
| Wireless Range | 20 m (obstructed) / 100 m (line-of-sight) |
| Data Storage | 16,000 records |
| Display | 3.5″ backlit color LCD |
| Connectivity | SD card slot, mini-USB port, wireless RCU link |
| Optional Accessories | Peltier cooler, peristaltic condensate pump, 5-year O₂ sensor, integrated thermal printer, leak detection module, pitot tube/rotating vane anemometer interface, humidity & barometric pressure probe |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | OMS420 |
| Response Time | < 10 s |
| Measurement Principle | ZrO₂ Electrochemical Cell |
| Optional Sensor | COe (Combustible Gas Equivalent) |
| O₂ Range | 0–25% vol |
| COe Range (optional) | 0–1000 ppm |
| Accuracy | ±0.2% O₂ or ±5% of reading (whichever is greater) |
| Repeatability | ≤ ±1% FS |
| Warm-up Time | 30 min |
| Service Life | > 5 years |
| Analog Outputs | Dual 4–20 mA (user-configurable range) |
| Digital Interface | RS485 (Modbus RTU) |
| Power Supply | 18–24 VDC / 90–100 W |
| Calibration Port | Threaded connection for 6/4 mm tubing |
| Purge Air Interface | Quick-connect fitting, 8 mm, 6–8 bar compressed air required |
| Operating Ambient Temperature (electronics) | –20 °C to +60 °C |
| Enclosure Rating | IP65 |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | OPTIMA7 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ 0.5% FS (Note: “≤0%” is technically invalid |
| Response Time | ≤ 10 s (T90) |
| Drift Stability | ≤ 1% FS/24 h |
| Measurable Parameters | O₂, CO (with H₂ compensation), COlow, NO, NOlow, NO₂, SO₂, H₂S, CO₂, Flue Gas Temperature (0–1100 °C), Ambient Air Temperature (0–100 °C), Static Pressure (±100 hPa), Differential Pressure (±100 hPa), Gas Velocity (3–100 m/s), Combustion Efficiency |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | VARIO plus-new |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Dual-mode — NDIR (CO₂, CO, NO, SO₂, NO₂, HC) + Electrochemical (O₂, CO, NO, SO₂, NO₂, H₂) |
| Accuracy | ≤ ±5% FS |
| Repeatability | ≤ 1% FS |
| Response Time (T₉₀) | ≤ 20 s |
| Drift Stability (24 h) | ≤ 1% FS |
| Measured Gases | O₂, CO₂, CO, NO, SO₂, NO₂, HC (as C₃H₈), H₂ |
| Operating System | Embedded Linux |
| Display | 7″ TFT color touchscreen (800 × 480 px) |
| Data Interfaces | Ethernet, WLAN (802.11 b/g/n), Bluetooth 4.0, USB 2.0, RS485, 8 × 4–20 mA analog outputs, 4 × 4–20 mA analog inputs, AUX port (K-type thermocouple, 0–10 V, 4–20 mA, RS485) |
| Power | Rechargeable 48 Wh Li-ion battery (typ. 6 h operation) |
| Condensate Management | Integrated Peltier cooler + automatic peristaltic condensate pump |
| Auto-Calibration | Scheduled zero calibration during continuous operation |
| Data Export | CSV/PDF reports via USB or network |
| Compliance | EN 50379-1/-2, EN 15267-3, MCERTS (UK), EPA Method 6C/7E/10, ISO 12039, ISO 10849, DIN 33430, GLP-compliant data logging with audit trail capability |
| Brand | 4Labplus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Class | Benchtop Laboratory System |
| Model | MSP100 |
| Detection Principle | Manual Liquid Spiking onto Sorbent Tubes |
| Configuration | Integrated Liquid Needle Stage, Sorbent Tube Holder, and Solvent Vial Mounting Base |
| Accuracy | ±5% (gravimetric/volumetric spiking consistency) |
| Response Time | 2 min (time per spiking cycle, including needle positioning and liquid delivery) |
| Tube Compatibility | Standard 3.5" × 1/4" OD stainless steel or glass sorbent tubes |
| Purge Gas Flow Control | Adjustable via precision needle valve |
| Vaporization Path Volume | < 0.5 mL (optimized to minimize analyte dispersion and adsorption loss) |
| Brand | MSR Analytical |
|---|---|
| Model | GXH-3050E |
| Origin | Beijing, China |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | NDIR (Non-Dispersive Infrared) with optional TCD, Electrochemical, and Fluorescence Detection Modules |
| Measurable Gases | CO, CO₂, CH₄, C₃H₈, HC (hydrocarbons), H₂, O₂, H₂S, SO₂, NH₃ |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ ±1% FS |
| Response Time | ≤ 60 s |
| Zero & Span Drift | ≤ ±1% FS / 48 h |
| Warm-up Time | ≤ 30 min |
| Operating Humidity | ≤ 90% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% or internal 7.5 V DC Li-ion battery |
| Output Interface | RS232 serial communication |
| Sample Conditioning | Integrated probe with cooling, particulate filtration, moisture removal, and chemical scrubbing |