Showing 2551–2580 of 2968 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ADR-1500 |
| Pricing | Upon Request |
| Measurement Principle | Optical Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Enclosure Rating | IP65 |
| Power Options | AC, External DC, Internal Rechargeable Battery |
| Communication Interfaces | USB, RS-232, 0–5 V / 4–20 mA Analog Output, Optional Wireless Module |
| Environmental Compensation | Integrated Temperature, Relative Humidity, and Barometric Pressure Sensors with Active Heating |
| Flow Control | True Volumetric Flow Control via Digital Feedback Loop Using Calibrated Critical Orifice and Differential Pressure Sensor |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific ADR-1500 |
| Measurement Principle | Optical Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀, PM₂.₅, PM₄, PM₁ |
| Measurement Range | 0.001–400 mg/m³ (Auto-ranging) |
| Detection Limit | 0.1 µg/m³ |
| Sampling Flow Rate | 1.0–3.5 L/min |
| Flow Stability | ±2% of reading or ±0.005 mg/m³ (whichever is greater), 1-s averaging |
| Accuracy | ±5% of reading (traceable to SAE test standards) |
| Precision | ±2% (1 s), ±0.5% (10 s), ±0.2% (60 s) |
| Scatter Coefficient Range | 1.1×10⁻⁶ to 0.6 m⁻¹ (@ λ = 880 nm) |
| Aerodynamic Particle Size Cut Points | 1.0–10 µm (with optional cyclone cutters: GK2.05 for PM₄–PM₁₀ |
| Operating Environment | IP65-rated weatherproof enclosure |
| Power Options | AC, external DC, or internal rechargeable battery (up to 100 h continuous operation) |
| Data Connectivity | Wireless/3G, USB, RS-232, analog output |
| Onboard Display | Dual-line LCD showing real-time concentration, start time, date, average concentration, and runtime |
| Temperature & Humidity Compensation | Integrated heated sensor assembly with RH/T correction |
| True Volumetric Flow Control | Enabled via digital feedback from barometric pressure, temperature, and calibrated orifice ΔP sensors |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AerosolSense & Renvo |
| Instrument Type | Aerosol Pathogen Monitoring System |
| Detection Target | Influenza A/B, SARS-CoV-2, RSV-B |
| Sample Processing Time (Renvo) | ≤30 min |
| Amplification Technology | Oscillating Amplification Reaction (Oscar™) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | APIX |
| Detection Targets | Conventional + Specialty Gas Trace Impurities |
| Detection Method | Atmospheric Pressure Ionization Mass Spectrometry (API-MS) |
| Mass Range | 1–300 AMU |
| Ion Source | Atmospheric Pressure Ionization (API) |
| Background Level | <1 ppt |
| Detector | 100 MHz Pulse-Counting Electron Multiplier |
| Noise Floor | 10 counts per 10⁶ pulses |
| LOD | <10 ppt (compound-dependent) |
| Analysis Time per Component | <1 s |
| Typical Cycle Time | <5 s |
| Flow Path Switching Time | <15 min (to sub-ppb stability) |
| Compatible Bulk Gases | UHP H₂, N₂, Ar, He |
| Dimensions (δQ) | 1.9 m (H) × 0.7 m (W) × 0.65 m (D) |
| Dimensions (Quattro) | 1.9 m (H) × 2.1 m (W) × 0.65 m (D) |
| Communication Protocols | OPC UA, Modbus TCP/RTU, PROFIBUS DP, Siemens 3964R, DDE, EtherNet/IP |
| Software Platform | Thermo Scientific GasWorks® v5.x |
| Compliance | Designed for ISO 9001-certified manufacturing |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APIX |
| Detection Range | 1–300 AMU |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM-1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10 / PM2.5 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | In-situ dilution sampling with wet-gas analysis |
| Compliance | EPA Reference Method 10, ASTM D6522, ISO 12039, EN 14181, US EPA PS-11 & PS-2 |
| Certifications | ISO 9001, China National Environmental Protection Agency (MEP) Certification, China National Technical Supervision Bureau Certification |
| Calibration | Full-system dynamic calibration (probe-to-analyzer) per EPA requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CEMS Hg |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ChemComb 3500 |
| Configuration | Integrated Multi-Phase Sampling Cartridge |
| Flow Rate | 10 L/min (PM₂.₅/PM₁₀ mode) |
| Diffusion Tube Material | Borosilicate Glass |
| Diffusion Tube Dimensions | Ø47 mm × 38 mm, ~212 hexagonal channels per unit, channel side length ≈ 2 mm, internal surface area ≈ 775 cm² |
| Filter Format | Four-stage 47 mm filter holder (PTFE construction) |
| Inlet Options | Anodized Aluminum or PTFE-coated PM₂.₅ (10 & 16.7 L/min) and PM₁₀ (10 L/min) cyclones |
| Organic Sorbent Stages | Optional PUF and/or XAD-2 resin beds downstream of filters |
| External Diameter (excl. clamps) | 7.49 cm |
| External Diameter (incl. clamps) | 9.68 cm |
| Length (inlet to 1/4″ quick-connect outlet) | 28.27 cm |
| Weight (empty) | 1.23 kg |
| Weight (with two diffusion tubes) | 1.45 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Dilution |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±0.5% of full scale (typical for certified dilution CEMS per EPA PS-2 and ISO 14956) |
| Repeatability | <0.3% RSD (under stable operating conditions) |
| Response Time (T90) | <120 s for SO₂ and NOₓ |
| Long-Term Stability | <1% drift over 7 days (with daily system calibration) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Thermo Scientific DM5018 |
| Measurement Principle | Beta-ray Attenuation |
| Measured Parameters | TSP / PM₁₀ / PM₂.₅ |
| Measurement Range | 0–10 mg/m³ |
| Sampling Flow Rate | 16.67 L/min |
| Detection Limit | <4 µg/m³ (1-hr avg), <1 µg/m³ (24-hr avg) |
| Flow Stability | ±2% of reading |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Environmental & Process Instruments |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Price Range | USD 70,000 – 140,000 |
| Measurement Accuracy | Not Specified |
| Repeatability | Not Specified |
| Response Time | Not Specified |
| Long-Term Stability | Not Specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FGD-CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Dilution Extraction with UV/IR Absorption and Paramagnetic/O2 Electrochemical Detection |
| Key Parameters | SO₂, NOₓ, CO, O₂, Flow Rate, Temperature, Static Pressure, Particulate Matter (PM), Relative Humidity, Total Reduced Sulfur (TRS), H₂S |
| Compliance Framework | EPA Performance Specifications (PS-2, PS-3, PS-5, PS-15), EN 15267, ISO 14001, US EPA Method 6C, Method 7E, Method 10, Method 3A, ASTM D6522, ASTM D5197 |
| Data Integrity | 21 CFR Part 11–compliant audit trail, GLP/GMP-ready reporting |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific FH62C14 |
| Measurement Principle | Beta Ray Attenuation |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Range | 0–5,000 µg/m³ or 0–10,000 µg/m³ (selectable) |
| LOD | 4 µg/m³ (1-hr avg), 1 µg/m³ (24-hr avg) |
| Flow Rate | 1 m³/h (16.7 L/min) |
| Radioisotope | ¹⁴C sealed source in BaCO₃ matrix |
| Activity | <3.7 MBq (<100 µCi), exempt under U.S. NRC regulations |
| Data Storage | >1 year of half-hourly mass concentration averages |
| Flow Mode Options | Standard temperature & pressure (STP) or actual ambient flow |
| Interference Compensation | Automatic correction for ambient radioactivity |
| Environmental Robustness | Immune to vibration and diurnal temperature fluctuations |
| Communication | Dual RS-232 serial ports for remote control and data export |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | FH62C14 |
| Measurement Method | Beta-Ray Absorption |
| Measured Parameter | PM2.5 |
| Radioisotope Source | Carbon-14 (¹⁴C) |
| Activity | <3.7 MBq (<100 μCi) |
| Measurement Range | 0–5000 μg/m³ or 0–10000 μg/m³ |
| LOD (24-h avg) | <1 μg/m³ |
| LOD (1-h avg) | <4 μg/m³ |
| Accuracy | ±2 μg/m³ (24-h) |
| Resolution | ±1 μg/m³ (instantaneous) |
| Correlation Coefficient | R > 0.98 |
| Sampling Flow Rate | 1 m³/h (16.67 L/min), adjustable 0–20 L/min via built-in critical orifice |
| Operating Temperature | −30 °C to +60 °C |
| Data Averaging Intervals | 0.5, 1, 3, and 24 hours |
| Storage Capacity | >1 year of half-hourly averages |
| Communication Interfaces | Dual RS-232 serial ports |
| Analog Outputs | 4–20 mA or 0–10 V |
| Power Supply (Analyzer) | 100–240 VAC, 50/60 Hz, 15 W |
| Power Supply (Pump) | 220–240 VAC, 50/60 Hz, 100 W |
| Dimensions (Analyzer) | 483 mm (W) × 311 mm (H) × 330 mm (D) |
| Weight (Analyzer) | 22.5 kg |
| Dimensions (Pump) | 210 mm (W) × 222 mm (H) × 108 mm (D) |
| Weight (Pump) | 8.16 kg |
| Regulatory Certifications | U.S. EPA and California Air Resources Board (CARB) equivalency for PM₂.₅ and PM₁₀ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific GM-5000 |
| Measurement Principle | Optical Scattering (for PM), Electrochemical (for SO₂, NO₂, NO, CO), Photoionization Detection (for TVOC), UV Absorption (for O₃) |
| Measured Parameters | PM₂.₅, PM₁₀, SO₂, NO₂, NO, O₃, CO, TVOC |
| Measurement Range | PM₂.₅ / PM₁₀: 0–1500 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 0–500 ppb |
| CO | 0–50 ppm |
| TVOC | 0–40 ppm |
| Sampling Interval | 10 s |
| Sample Flow Rate | >1.5 L/min |
| Detection Limits | PM₂.₅ / PM₁₀ <1.0 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 5 ppb |
| CO | 0.02 ppm |
| TVOC | 5 ppb |
| Flow Stability | ±2.5% of full scale (all sensors) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | GM-5000 |
| Instrument Type | Online Fixed-Station Monitor |
| Measured Gases | NO₂, SO₂, O₃, CO |
| Response Time (T90) | 120 s (all sensors) |
| Measurement Accuracy | ±10 ppb (gaseous pollutants) |
| Measurement Ranges | NO₂: 0–20 ppm |
| SO₂ | 0–50 ppm |
| O₃ | 0–20 ppm |
| CO | 0–500 ppm |
| PM₂.₅ | 0–1500 µg/m³ |
| PM₁₀ | 0–1500 µg/m³ |
| Detection Limits (2σ) | NO₂: 30 ppb |
| SO₂ | 40 ppb |
| O₃ | 30 ppb |
| CO | 25 ppb |
| PM₂.₅ & PM₁₀ | <1.0 µg/m³ |
| Linearity | ±5% of full scale |
| Zero Drift | ±1% of full scale |
| Repeatability | ±2.5% of full scale |
| Resolution | 10 ppb (gases), 0.1 µg/m³ (PM) |
| Sample Flow Rate | >1.5 L/min |
| Data Logging Interval | 1 min to 1 h |
| Onboard Storage | >500,000 records (~1 year) |
| Operating Temperature | –10 °C to +45 °C |
| Operating Humidity | 15–90% RH (non-condensing) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Dimensions | 406 mm (H) × 305 mm (W) × 152 mm (D) |
| Weight | 5 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Hg CEMS |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRAN SapphIRe |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | 3880i |
| Instrument Type | Flue Gas PM CEMS |
| Measurement Principle | Dual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM) |
| Traceability | NIST-traceable mass concentration |
| Compliance | EPA PS-11, QA/QC Procedure 2, Method 5/17 Verified |
| Range | 0–250 mg/m³ (extendable to 0–5 mg/m³ low-range mode) |
| Accuracy | ±20% (uncorrected), ±10% (source-corrected) |
| Detection Limit | 0.25 mg/m³ (15-min integrated) |
| Response Time (T90) | 15 min |
| Power Supply | 200–240 VAC, 50/60 Hz, 30 A |
| Purge Air | 80 slpm at 0.55–0.7 MPa |
| Max Flue Gas Temp | 200 °C |
| Operating Ambient Temp (Controller) | 4–50 °C, non-condensing |
| Analog Outputs | 6 × 0–100 mV / 1/5/10 V, 6 × 0–20 mA / 4–20 mA |
| Digital I/O | 1 power-fail alarm, 10 relay outputs |
| Probe Dimensions | 1117.85 mm (W) × 474.73 mm (H) × 7.09 mm (D), with 914/1524 mm sheath |
| Probe Weight | 59 kg |
| Controller Dimensions | 482.6 mm (19″ W) × 189.5 mm (H) × 655.32 mm (D) |
| Controller Weight | 25 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410 |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | 5012, MAAP |
| Measurement Principle | Multi-angle absorption photometry |
| Measured Parameters | BC (Black Carbon), PM₁₀, PM₂.₅ |
| Detection Limit (2-min avg) | <100 ng/m³ BC, <0.66 M/m Babs |
| Detection Limit (10-min avg) | <50 ng/m³ BC, <0.33 M/m Babs |
| Detection Limit (30-min avg) | <20 ng/m³ BC, <0.13 M/m Babs |
| Flow Rate | 0.5–1.4 m³/h (16.7 L/min nominal) |
| Linearity Error | <1% @ 16.7 L/min |
| Filter Medium | Glass fiber tape (~40 m length) |
| Data Storage | 18,560 concentration values |
| Operating Temperature | −20 to +50 °C |
| Power | Instrument: 100–240 V, 50/60 Hz, 30 W |
| Pump | 220–240 V, 50/60 Hz, 100 W |
| Dimensions (Instrument) | 483 × 311 × 330 mm (W×H×D) |
| Weight (Instrument) | 22.5 kg |
| Pump Dimensions | 210 × 222 × 108 mm |
| Pump Weight | 6.1 kg |
| Analog Output | 0/4–20 mA or 0–10 V |
| Digital Interface | Dual RS-232 serial ports |
| Sampling Efficiency | >98% duty cycle |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Model 5014i Beta |
| Measurement Principle | Beta-ray attenuation |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Radioisotope Source | Carbon-14 (¹⁴C) |
| Range Options | 0–1.0 / 2.0 / 3.0 / 5.0 / 10.0 mg/m³ (equivalent to 0–100 / 1,000 / 2,000 / 3,000 / 5,000 / 10,000 µg/m³) |
| LOD | 6 µg/m³ (0.5-hr avg), 4 µg/m³ (1-hr avg), 3 µg/m³ (3-hr avg), 1 µg/m³ (24-hr avg) |
| Resolution | 1 µg/m³ |
| Accuracy | ±5% (mass measurement, NIST-traceable membrane standards) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Thermo Scientific 5030 SHARP (High-Volume Sampling Configuration) |
| Instrument Type | High-Volume Ambient Air Sampler |
| Sampling Path | Single-Channel |
| Flow Range | PM₁₀ & PM₂.₅: 40 SCFM (1,133 L/min) |
| Flow Accuracy | Mass Flow Control: ±2.5% deviation over 24 h |
| Volumetric Flow Control | <1% deviation over 24 h |
| Power | 750 W (Mass Flow) / 840 W (Volumetric Flow) |
| Motor | 0.6 HP (Mass Flow) / 0.1 HP (Volumetric Flow) |
| Compliance | EPA Reference Method for PM₁₀/PM₂.₅ (40 CFR Part 53), ISO 12103-1, ASTM D1424 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | 5030i |
| Measurement Principle | Beta-ray Absorption + Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Detection Limit | <0.5 µg/m³ (1-hr, 2σ), <0.2 µg/m³ (24-hr, 2σ) |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±5% (mass-based, traceable to NIST) |
| Range | 0–10,000 µg/m³ (7 full-scale options) |
| Flow Rate | 16.67 L/min (1 m³/h), ±2% accuracy |
| Operating Temperature | Sample gas: −30 to +50 °C |
| Analyzer enclosure | +4 to +50 °C |
| Power | 100–240 VAC, 50/60 Hz, max 880 W |
| Dimensions | 425 mm (W) × 584 mm (D) × 219 mm (H) |
| Weight | 19 kg |
| Compliance | US EPA Federal Equivalent Method (FEM) for PM₂.₅ and PM₁₀, CE, UL 61010-1, CSA C22.2 No. 61010-1, FCC Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Reference/Equivalent Method PM Sampler |
| Models | Partisol 2000i (single-channel), Partisol 2000i-D (dual-channel) |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min (2000i-D), Coarse Particle Flow Rate: 1.67 L/min (2000i-D) |
| Total Flow Range | 5–17 L/min (2000i) |
| Data Storage | 86 days @ 5-min intervals, 32 filter records |
| Operating Temperature | −40 °C to +50 °C |
| Power | 1.1 A @ 240 VAC |
| Dimensions (H×W×D) | 1620 mm × 1175 mm × 927.5 mm (base unit) |
| Weight | 37.2 kg (2000i), 38.6 kg (2000i-D) |
| Compliance | U.S. EPA RFPS-0498-117 (PM₂.₅), RFPS-1298-126 (PM₁₀), RFPS-0509-175 (Coarse PM) |
| Filter Format | Dual 47 mm filter holders (2000i-D), single 47 mm holder (2000i) |
| Cut Points | PM₂.₅ (cyclone or impactor), PM₁₀ (inlet), Coarse PM (PM₁₀–PM₂.₅ via virtual impactor in 2000i-D) |
| Interface | RS-232, USB, Ethernet |
| Software | iPort™ Communications Suite, Activol™ Flow Management System |
| Safety Certification | CE EN 61326 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2000i-D / 2000i |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min |
| Coarse Particle Flow Rate | 1.67 L/min |
| Filter Format | Dual 47 mm membrane holders |
| Data Logging Interval | 5 min |
| Internal Memory Capacity | 86 days @ 5-min intervals + 32 filter records |
| Communication Interfaces | RS-232, USB, Enhanced Ethernet (iPort™) |
| Operating Temperature Range | −40 °C to +50 °C |
| Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), Equivalent Method for PM₁₀ and Coarse PM (PM₁₀–PM₂.₅), ASTM D6216, ISO 7708 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 2015i/2025i-D |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15.0 L/min ±2% |
| Coarse Particle Flow Rate | 1.67 L/min ±2% |
| Filter Format | Dual 47 mm membrane filters per sampling cycle |
| Filter Capacity | Up to 16 filter cassettes (32 total filters) |
| Data Logging Interval | 5-minute resolution |
| Internal Memory | 86 days of operational data (5-min intervals) + 32 filter cycle records |
| Communication Interfaces | RS-232, USB 2.0, Ethernet (10/100 Mbps), iPort™ embedded communications module |
| Operating Temperature Range | −40 °C to +50 °C |
| Regulatory Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), EPA Equivalent Method for PM₂.₅ and Coarse PM (PM₁₀–PM₂.₅), ISO 12103-1, ASTM D1739, EN 12341 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Models | Partisol 2025i, Partisol 2025i-D |
| Flow Control | Activol Mass Flow Controller |
| Volume Flow Range | 1.67–15 L/min |
| Flow Accuracy | ±2% of setpoint |
| Operating Temperature | −40 °C to +50 °C |
| Power Requirement | 1.5 A @ 240 VAC |
| Data Storage | 86 days at 5-minute intervals + 32 filter records |
| Compliance | U.S. EPA Reference Methods RFPS-0498-118 (PM₂.₅), RFPS-1298-127 (PM₁₀), RFPS-0509-176 (Coarse PM) |
| Safety Certification | CE / EN 61326 |