Empowering Scientific Discovery

Grabner Instruments GmbH, a member of AMETEK Inc.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelMINIVAP Online
Analysis MethodThree-Stage Expansion Method
Pressure Range0 to 1000.0 kPa
Temperature Range20–60 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
ManufacturerGrabner Instruments GmbH
Product TypeImported Industrial Analyzer
ModelMINISCAN IR Vision Diesel
Measurement ParameterCetane Number
PortabilityPortable
Detection PrincipleMid-Infrared (MIR) Spectroscopy
Measurement Range20–80 CN
Measurement Accuracy±0.1 CN
Analysis Time≤60 s
Sample Volume10 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeManufacturer
Product CategoryImported Instrument
ModelMiniVAP VPVision Crude Oil
Analysis MethodThree-Stage Expansion Method
Pressure Range0–2000 kPa
Temperature Range0–120 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
ManufacturerGrabner Instruments GmbH
TypeImported
ModelIROX DIESEL
Measurement ParametersCetane Number (CN), Cetane Index (CI), FAME Content (0–40 v%), Polycyclic Aromatic Hydrocarbons (PNA), Total Aromatics, Distillation Temperatures (T85/T90/T95), Density (via integrated Anton Paar DMA)
PortabilityPortable
Detection PrincipleMid-Infrared Fourier Transform Spectroscopy (FTIR)
Spectral Resolution4 cm⁻¹
Measurement RangeCetane Number 25–75, Cetane Index 30–70, FAME 0–40 v%
RepeatabilityCN ±0.8, CI ±0.4, FAME SD = 0.04–1.20 v% (dependent on concentration)
Measurement Time≤180 s per sample
Sample Volume7 mL
Preheat Time10 min
Power Supply100–230 V AC, 50/60 Hz, 65 W or 12 V DC / 4 A (vehicle battery)
Dimensions200 × 320 × 220 mm
Weight11 kg
Data InterfaceRS-232
DisplayBacklit LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelMiniVAP VPS/VPSH
Analysis MethodThree-Stage Expansion Method
Pressure Range0–1000 kPa
Temperature Range0–100 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRABNER
OriginAustria
ModelMINIFLASH FPA VISION
Detection MethodClosed-Cup
Operation ModeFully Automatic
Temperature Range−25 °C to 400 °C
Ignition SourceElectric Arc
Repeatability≤0.5 °C
Compliant StandardsASTM D6450, ASTM D7094
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelMINIVAP VP Vision
Analysis MethodThree-Stage Expansion Method
Pressure Range0–2000 kPa
Temperature Range0–120 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelMINISCAN IR Vision
Measurement ParametersGasoline Octane Number (RON/MON), Diesel Cetane Number
PortabilityPortable
Detection PrincipleMid-Infrared Spectroscopy
Measurement Range70–110 (Octane/Cetane scale)
Accuracy±0.1
Analysis Time≤60 s
Sample Volume6 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelMiniVAP VPXpert
Analysis MethodThree-Stage Expansion Method
Pressure Range0–1000 kPa
Temperature Range0–120 °C
Sample Volume1 mL
Temperature Stability±0.1 °C
V/L Ratio Adjustable0.02/1 to 4/1
ComplianceASTM D5191, D6377, D6378, D323, D4953, D5188, D5190, D5482
Data InterfaceDual USB, RS232, LIMS-compatible
Power Input90–264 V AC, 45–63 Hz, 200 W
Dimensions277 × 253 × 368 mm
Weight9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRABNER
OriginAustria
ModelMobileLab
ApplicationGasoline Octane Number (RON/MON) and Diesel Cetane Number (CN) Analysis
PortabilityFully Mobile Laboratory Vehicle
Measurement PrincipleNear-Infrared (NIR) Spectroscopy
Measurement Range40–120 (Octane/Cetane Scale)
Accuracy±1 unit
Analysis Time<15 minutes per sample
Sample Volume10 mL
Power SupplyDual-source — rechargeable 12 V DC battery + external 240 V AC input
ComplianceDesigned to support ASTM D2699, D2700, D613, ISO 5164, ISO 5163, EN 228, EN 590, GOST R 51105, GOST R 51463
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelMINISCAN IR Vision Pro
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelMiniFlash
Detection MethodClosed-Cup (ASTM D6450 / D7094, ISO 2719, SH/T 0768-2005)
Operation ModeFully Automatic
Temperature Range–25 °C to 400 °C
Ignition SourceElectric Arc
Sample Volume1–2 mL
Temperature Accuracy±0.1 °C
Test Duration3–5 min per sample
Data StorageInternal memory for multiple test records
ConnectivityRS-232, LIMS-ready interface, printer & PC compatible
Power Supply100/200/230 V AC, 50 Hz, 65 W
Optional DC Input12 V / 8 A (vehicle battery)
Dimensions196 × 315 × 175 mm
Weight8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
ManufacturerGrabner Instruments GmbH
TypeImported
ModelIROX 2000
Measurement ParametersGasoline Octane Number (RON/MON), Diesel Cetane Number
PortabilityPortable
Detection PrincipleMid-Infrared (MIR) Spectroscopy
Measurement Range70–110 (Octane/Cetane scale)
Accuracy±0.5 Cetane Number
Analysis Time60 s
Sample Volume10 mL
Density Measurement±0.001 g/cm³ (integrated Anton Paar density module)
Spectral Range4000–400 cm⁻¹
Data Points~3000 per spectrum
Storage Capacity~200 test records
Power Supply100/200/230 V AC, 50 Hz, 65 W
Optional DC Input12 V / 8 A
Dimensions200 × 320 × 220 mm
Weight13 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
Country of OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelMINIFLASH FP VISION
Detection MethodClosed-Cup
Operation ModeFully Automatic
Temperature Range−25 °C to 400 °C
Ignition MethodElectric Arc Ignition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelMINISCAN IR Vision Gasoline
PortabilityPortable
Detection PrincipleMid-Infrared Spectroscopy
Measurement Range70–110 (RON/MON)
Measurement Accuracy±0.1
Analysis Time≤60 s
Sample Volume6 mL
ComplianceGB/T 33648–2017, ASTM D5845, ASTM D6277, EN 238, SH/T 0797, ASTM E1655, GB/T 29858
Calibration MethodPLS (Partial Least Squares) Multivariate Regression
Density MeasurementIntegrated thermoelectrically controlled densitometer (±0.0001 g/cm³)
Spectrometer CoreDual-interferometer with automatic mirror alignment
Beam SplitterGe substrate with KBr coating
Sample Cell Design2+1 intelligent thermostatted cells
Display10-inch industrial-grade full-color touchscreen
Data Interface2× USB, 2× LAN
Power Supply100–264 V AC, 47–63 Hz, 130 W
Optional DC Operation12 V vehicle adapter
Dimensions293 × 390 × 280 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelMiniFlash Touch FLP / FLPH
Temperature Range0–200°C (FLP) / 0–400°C (FLPH)
Sample Volume1–2 mL
Measurement PrincipleModified Continuously Closed Cup (MCCCFP) per ASTM D7094
ComplianceASTM D6450, ASTM D7094, ASTM D93, EN ISO 2719, EN ISO 3679, EN ISO 3680, ISO 13736, IP 170, ASTM D56
Accuracy (Repeatability / Reproducibility)±3.8°C / ±5.4°C per ASTM D7094
Ignition SourceHigh-energy electric arc
CoolingPeltier-based active cooling (FLPH model supports external chiller)
InterfacesUSB 2.0, Ethernet (10/100 Mbps), LIMS-ready, PC-compatible
Software PlatformMicrosoft® Windows®-based proprietary software with GLP-compliant audit trail
Data StorageUnlimited method and result storage on internal SSD
Portability12 kg, 253 × 368 × 277 mm, 12 V DC vehicle power option
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelMINISCAN IR Vision Professional
Measurement ParametersGasoline Octane Number (RON/MON), Diesel Cetane Number
PortabilityPortable
Detection PrincipleMid-Infrared Spectroscopy
Measurement Range70–110 (Octane/Cetane scale)
Accuracy±0.1
Analysis Time≤60 seconds
Sample Volume6 mL
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0