- All
- Favorite
- Popular
- Most rated
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINIVAP Online |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0 to 1000.0 kPa |
| Temperature Range | 20–60 °C |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer | Grabner Instruments GmbH |
| Product Type | Imported Industrial Analyzer |
| Model | MINISCAN IR Vision Diesel |
| Measurement Parameter | Cetane Number |
| Portability | Portable |
| Detection Principle | Mid-Infrared (MIR) Spectroscopy |
| Measurement Range | 20–80 CN |
| Measurement Accuracy | ±0.1 CN |
| Analysis Time | ≤60 s |
| Sample Volume | 10 mL |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | MiniVAP VPVision Crude Oil |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer | Grabner Instruments GmbH |
| Type | Imported |
| Model | IROX DIESEL |
| Measurement Parameters | Cetane Number (CN), Cetane Index (CI), FAME Content (0–40 v%), Polycyclic Aromatic Hydrocarbons (PNA), Total Aromatics, Distillation Temperatures (T85/T90/T95), Density (via integrated Anton Paar DMA) |
| Portability | Portable |
| Detection Principle | Mid-Infrared Fourier Transform Spectroscopy (FTIR) |
| Spectral Resolution | 4 cm⁻¹ |
| Measurement Range | Cetane Number 25–75, Cetane Index 30–70, FAME 0–40 v% |
| Repeatability | CN ±0.8, CI ±0.4, FAME SD = 0.04–1.20 v% (dependent on concentration) |
| Measurement Time | ≤180 s per sample |
| Sample Volume | 7 mL |
| Preheat Time | 10 min |
| Power Supply | 100–230 V AC, 50/60 Hz, 65 W or 12 V DC / 4 A (vehicle battery) |
| Dimensions | 200 × 320 × 220 mm |
| Weight | 11 kg |
| Data Interface | RS-232 |
| Display | Backlit LCD |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MiniVAP VPS/VPSH |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–1000 kPa |
| Temperature Range | 0–100 °C |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FPA VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | −25 °C to 400 °C |
| Ignition Source | Electric Arc |
| Repeatability | ≤0.5 °C |
| Compliant Standards | ASTM D6450, ASTM D7094 |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINIVAP VP Vision |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINISCAN IR Vision |
| Measurement Parameters | Gasoline Octane Number (RON/MON), Diesel Cetane Number |
| Portability | Portable |
| Detection Principle | Mid-Infrared Spectroscopy |
| Measurement Range | 70–110 (Octane/Cetane scale) |
| Accuracy | ±0.1 |
| Analysis Time | ≤60 s |
| Sample Volume | 6 mL |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MiniVAP VPXpert |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–1000 kPa |
| Temperature Range | 0–120 °C |
| Sample Volume | 1 mL |
| Temperature Stability | ±0.1 °C |
| V/L Ratio Adjustable | 0.02/1 to 4/1 |
| Compliance | ASTM D5191, D6377, D6378, D323, D4953, D5188, D5190, D5482 |
| Data Interface | Dual USB, RS232, LIMS-compatible |
| Power Input | 90–264 V AC, 45–63 Hz, 200 W |
| Dimensions | 277 × 253 × 368 mm |
| Weight | 9 kg |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MobileLab |
| Application | Gasoline Octane Number (RON/MON) and Diesel Cetane Number (CN) Analysis |
| Portability | Fully Mobile Laboratory Vehicle |
| Measurement Principle | Near-Infrared (NIR) Spectroscopy |
| Measurement Range | 40–120 (Octane/Cetane Scale) |
| Accuracy | ±1 unit |
| Analysis Time | <15 minutes per sample |
| Sample Volume | 10 mL |
| Power Supply | Dual-source — rechargeable 12 V DC battery + external 240 V AC input |
| Compliance | Designed to support ASTM D2699, D2700, D613, ISO 5164, ISO 5163, EN 228, EN 590, GOST R 51105, GOST R 51463 |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MINISCAN IR Vision Pro |
| Pricing | Upon Request |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MiniFlash |
| Detection Method | Closed-Cup (ASTM D6450 / D7094, ISO 2719, SH/T 0768-2005) |
| Operation Mode | Fully Automatic |
| Temperature Range | –25 °C to 400 °C |
| Ignition Source | Electric Arc |
| Sample Volume | 1–2 mL |
| Temperature Accuracy | ±0.1 °C |
| Test Duration | 3–5 min per sample |
| Data Storage | Internal memory for multiple test records |
| Connectivity | RS-232, LIMS-ready interface, printer & PC compatible |
| Power Supply | 100/200/230 V AC, 50 Hz, 65 W |
| Optional DC Input | 12 V / 8 A (vehicle battery) |
| Dimensions | 196 × 315 × 175 mm |
| Weight | 8 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer | Grabner Instruments GmbH |
| Type | Imported |
| Model | IROX 2000 |
| Measurement Parameters | Gasoline Octane Number (RON/MON), Diesel Cetane Number |
| Portability | Portable |
| Detection Principle | Mid-Infrared (MIR) Spectroscopy |
| Measurement Range | 70–110 (Octane/Cetane scale) |
| Accuracy | ±0.5 Cetane Number |
| Analysis Time | 60 s |
| Sample Volume | 10 mL |
| Density Measurement | ±0.001 g/cm³ (integrated Anton Paar density module) |
| Spectral Range | 4000–400 cm⁻¹ |
| Data Points | ~3000 per spectrum |
| Storage Capacity | ~200 test records |
| Power Supply | 100/200/230 V AC, 50 Hz, 65 W |
| Optional DC Input | 12 V / 8 A |
| Dimensions | 200 × 320 × 220 mm |
| Weight | 13 kg |
| Brand | Grabner |
|---|---|
| Country of Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MINIFLASH FP VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | −25 °C to 400 °C |
| Ignition Method | Electric Arc Ignition |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINISCAN IR Vision Gasoline |
| Portability | Portable |
| Detection Principle | Mid-Infrared Spectroscopy |
| Measurement Range | 70–110 (RON/MON) |
| Measurement Accuracy | ±0.1 |
| Analysis Time | ≤60 s |
| Sample Volume | 6 mL |
| Compliance | GB/T 33648–2017, ASTM D5845, ASTM D6277, EN 238, SH/T 0797, ASTM E1655, GB/T 29858 |
| Calibration Method | PLS (Partial Least Squares) Multivariate Regression |
| Density Measurement | Integrated thermoelectrically controlled densitometer (±0.0001 g/cm³) |
| Spectrometer Core | Dual-interferometer with automatic mirror alignment |
| Beam Splitter | Ge substrate with KBr coating |
| Sample Cell Design | 2+1 intelligent thermostatted cells |
| Display | 10-inch industrial-grade full-color touchscreen |
| Data Interface | 2× USB, 2× LAN |
| Power Supply | 100–264 V AC, 47–63 Hz, 130 W |
| Optional DC Operation | 12 V vehicle adapter |
| Dimensions | 293 × 390 × 280 mm |
| Weight | 12 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MiniFlash Touch FLP / FLPH |
| Temperature Range | 0–200°C (FLP) / 0–400°C (FLPH) |
| Sample Volume | 1–2 mL |
| Measurement Principle | Modified Continuously Closed Cup (MCCCFP) per ASTM D7094 |
| Compliance | ASTM D6450, ASTM D7094, ASTM D93, EN ISO 2719, EN ISO 3679, EN ISO 3680, ISO 13736, IP 170, ASTM D56 |
| Accuracy (Repeatability / Reproducibility) | ±3.8°C / ±5.4°C per ASTM D7094 |
| Ignition Source | High-energy electric arc |
| Cooling | Peltier-based active cooling (FLPH model supports external chiller) |
| Interfaces | USB 2.0, Ethernet (10/100 Mbps), LIMS-ready, PC-compatible |
| Software Platform | Microsoft® Windows®-based proprietary software with GLP-compliant audit trail |
| Data Storage | Unlimited method and result storage on internal SSD |
| Portability | 12 kg, 253 × 368 × 277 mm, 12 V DC vehicle power option |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINISCAN IR Vision Professional |
| Measurement Parameters | Gasoline Octane Number (RON/MON), Diesel Cetane Number |
| Portability | Portable |
| Detection Principle | Mid-Infrared Spectroscopy |
| Measurement Range | 70–110 (Octane/Cetane scale) |
| Accuracy | ±0.1 |
| Analysis Time | ≤60 seconds |
| Sample Volume | 6 mL |
Show next