| Brand | SDLATLAS |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | D394A |
| Pricing | Upon Request |
| Roller Width | 450 mm |
| Roller Diameter | 125 mm |
| Pneumatic Pressure Setting | 5 kg/cm² |
| Clamp Force | 3 tonnes |
| Independent Left/Right Nip Pressure Adjustment | Yes |
| Fixed Speed | 10 RPM (optional variable-speed Conally drive system available) |
| Padding Roller Hardness | 70 ± 5 Shore A |
| Trough Capacity | ~1000 mL |
| Safety Features | Safety Rod, Emergency Stop Button, Knee-Operated Stop Pedal |
| Brand | SDLATLAS |
|---|---|
| Model | D394B |
| Roller Width | 450 mm |
| Roller Diameter | 125 mm |
| Roller Hardness | 70 ± 2 Shore A |
| Drive Speed | Fixed at 10 rpm |
| Trough Capacity | ~1000 mL |
| Actuation | Pneumatic Load Control |
| Safety Interlocks | Integrated |
| Compatibility | Optional Air Compressor Supply |
| Integration | Designed for inline coupling with Mini Dryer or Stenter Frame |
| Brand | Rofin |
|---|---|
| Origin | Australia |
| Model | PL550XL |
| Lamp Type | 500 W Xenon Arc |
| Input Voltage | 85–265 VAC, 50–60 Hz auto-sensing |
| Optical Output | UV–Visible Liquid Light Guide (2 m standard), optional IR Liquid Light Guide (2 m) with IR bandpass filters (>610 nm, >715 nm, >780 nm, >830 nm) |
| Wavelength Selection | Blank, White, 350 nm, 415 nm, 450 nm, 470 nm, 490 nm, 505 nm, 530 nm, 555 nm, 590 nm, 620 nm, 650 nm |
| Power Settings | P1–P8 continuous |
| User Interface | Three rotary dials (wavelength, power, fine adjustment), LED display, three programmable memory buttons, intelligent standby/power button, integrated light guide mounting points |
| Cooling System | Microprocessor-controlled variable-speed fan |
| Compliance | Designed for forensic laboratory environments compliant with ISO/IEC 17025 documentation practices and compatible with GLP/GMP audit trail requirements in evidence handling workflows |
| Standard Accessories | Camera filter set (OG475, OG515, OG550, OG590), high-pass camera adapters, 52/58 mm & 49/58 mm step-up rings, amber/red/neutral/yellow protective eyewear |
| Brand | POLOS |
|---|---|
| Origin | Germany |
| Model | SPIN150i |
| Maximum Substrate Diameter | 150 mm (round) / 150×150 mm (square) |
| Rotation Speed Range | 0–12,000 rpm (±0.1 rpm accuracy) |
| Acceleration/Deceleration | 1–30,000 rpm/sec (adjustable in steps) |
| Rotation Modes | Programmable CW, CCW, and oscillatory stirring |
| Safety | Sensor-interlocked automatic lid lock |
| Standard Chuck | Vacuum chuck A-V36 + fragment adapter D-V10 |
| Housing Material | NPP (standard), optional PTFE version |
| Control Interface | Removable full-color touchscreen with intuitive recipe programming and storage |
| Optional Modules | Multi-nozzle dispensing (up to 6 independently programmable nozzles), ultrasonic cleaning, sequential/parallel chemical delivery |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CEF |
| Type | Polyolefin Characterization Analyzer |
| Automation Level | Fully Automated |
| Analysis Time per Sample | ≤25 min |
| Sample Capacity | 42-position autosampler |
| Detection Options | IR4 or IR5 FTIR concentration detectors |
| Optional Detectors | Viscometer, Multi-Angle Light Scattering (MALS) |
| Temperature Range | –20 °C to 160 °C (with low-temp and high-temp accessories) |
| Compliance | Designed for GLP/GMP environments |
| Software | CEF Control & Analysis Suite (21 CFR Part 11 compliant audit trail optional) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CFC |
| Type | Cross-Fractionation Chromatography System |
| Application | Polyolefin Microstructure Characterization |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CFC Instrument for Polymerization Process Optimization Analysis |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFC Microstructural Differentiation Analyzer |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFC |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTAF |
| Sample Capacity | 5 samples per run |
| Cycle Time | ~6 hours |
| Minimum Operating Temperature | −20 °C |
| Detection | IR4 Infrared Detector |
| Configuration | Benchtop, Fully Automated |
| Solvent Handling | Closed-loop, Minimal Consumption |
| Software Interface | Intuitive GUI with Remote Monitoring & Diagnostics |
| Upgrade Path | Compatible with CRYSTAF-TREF dual-technique configuration |
| Compliance | Designed to support GLP/GMP workflows and ASTM D7283 (Standard Test Method for Determination of Comonomer Content in Polyolefins by Crystallization Analysis) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CRYSTAF QC |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTAF-TREF |
| Technique | Dual-Mode (Crystallization Analysis Fractionation & Temperature Rising Elution Fractionation) |
| Sample Capacity | 5 samples per run |
| Analysis Time | ≤6 h/sample (TREF mode), ≤8 h for 5 samples (CRYSTAF mode) |
| Minimum Operating Temperature | −20 °C |
| Detector Options | IR4 Fourier-transform infrared detector, Differential Viscometer, Multi-Angle Light Scattering (MALS) |
| Automation Level | Fully automated solvent handling, fraction collection, and system cleaning |
| Software Compliance | Audit-trail enabled, user access control, 21 CFR Part 11–ready configuration available |
| Regulatory Alignment | Designed to support ASTM D7943, ISO 16152, and ISO 16014–4 workflows |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRYSTEX |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTEX QC |
| Sample Vessel Capacity | 240 mL |
| Maximum Sample Mass | 4 g |
| Analysis Time per Sample | 150 min |
| Detector Configuration | Dual-channel concentration detector + composition detector |
| Operational Mode | Unattended 7×24 h |
| Solvent Handling | Fully enclosed, operator-free solvent exposure |
| Compliance | Designed for ISO 16152, ASTM D5492, and internal QC/GLP workflows |
| Software | CRYSTEX Control & Evaluation Suite with audit trail and user access levels |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EFS |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR Advanced |
| Application | Simultaneous Quantification of Xylene Solubles, Ethylene Content, and Intrinsic Viscosity in Impact Polypropylene |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR5 |
| Temperature Range | 160 °C (max) |
| Detection | Dual IR5 Infrared Detectors (CH₂/CH₃ channels) |
| Columns | PL-PEG 10⁶–10⁷ Da & HT-Mixed-B for UHMW polyolefins |
| Solvent Compatibility | 1,2,4-Trichlorobenzene (TCB) |
| Flow Rate | 0.5–1.0 mL/min |
| Calibration Standards | Narrow-distribution polyethylene standards (NIST-traceable) |
| Software | Cirrus GPC/SEC v5.x with ASTM D6474 & ISO 16014-4 compliant reporting |
| Data Security | FDA 21 CFR Part 11–ready audit trail, electronic signatures, and user access levels |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GPC-IR5 |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-QC |
| Operating Temperature Range | 140–160 °C |
| Analysis Time per Sample (incl. dissolution) | ≤30 min |
| Detection | IR5 Selective Infrared Detector (C–H stretch, 3.42 µm) |
| Concentration Sensitivity | 0.125 mg/mL (S/N ≥60) |
| Optional Detectors | Dual Capillary Viscometer (IV), IR4 |
| Column Configuration | Pre-packed High-Throughput GPC Columns (macroporous crosslinked polystyrene/divinylbenzene, calibrated for polyolefins) |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data handling |
| Sample Throughput | Up to 24 samples unattended |
| Dimensions | Benchtop (W × D × H: 750 × 600 × 550 mm) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | HT-GPC System for Molecular Weight, Long-Chain Branching (LCB), and Short-Chain Branching (SCB) Distribution Analysis |
| Detection Modes | Infrared (IR5), Differential Viscometry, Composition-Sensitive Detection |
| Temperature Range | Up to 160 °C |
| Solvent Compatibility | 1,2,4-Trichlorobenzene (TCB), ODCB |
| Calibration Standards | Narrow-MWD PE/PP Reference Standards |
| Data Output | Mw, Mn, Mz, Đ, LCB frequency (λ), SCB density (branches/1000C), Branch Length Distribution, Compositional Heterogeneity Index (CHI) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | IVA |
| Dissolution Temperature Range | Up to 200 °C |
| Sample Capacity | 42 positions |
| Capillary System | Dual stainless-steel capillary viscometer |
| Optional Detector | IR4 infrared detector for C–H bond quantification |
| Solvent Handling | Fully automated solvent addition, dissolution, and system cleaning |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | Microstructural Differentiation Analyzer for Polyolefin Films and Fish-Eye Defects |
| Application Domain | Polyolefin Film Quality Control & Defect Root-Cause Analysis |
| Compliance Framework | ASTM D1238, ISO 1133, ISO 1628-1, ISO 15270, USP <1058> Analytical Instrument Qualification |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | C20 |
| Fractionation Capacity | 10–20 g per run |
| Operating Modes | TREF (Temperature Rising Elution Fractionation) and Molar Mass Fractionation |
| Cycle Time | ≤48 h including dissolution |
| Fraction Collection | Up to 9 fractions per run |
| Detection | Integrated IR detector for real-time fraction monitoring |
| Control | Remote operation and interactive diagnostics enabled |
| Compliance | Designed for GLP-compliant laboratories |
| Software | Fully automated method sequencing with audit trail capability |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | PREP C20 |
| Application | Automated Temperature Rising Elution Fractionation (TREF) and Crystallization Analysis Fractionation (CRYSTAF) of Polyolefins |
| Throughput | 10–20 g per run |
| Fraction Number | Up to 9 discrete fractions |
| Cycle Time | ~60 hours per full fractionation sequence |
| Compliance | Designed for ASTM D6964 (TREF), ASTM D7282 (CRYSTAF), ISO 16152, ISO 16014-3 |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PREP mc2 |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model Compatibility | GPC-IR5, IR4, TREF, CRYSTAF, and Related Polyolefin Analyzers |
| Lead Time | Up to 4 weeks (standard stock available for high-turnover items) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFD |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TGIC Analysis Service |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | TGIC |
| Application Field | Polyolefin Characterization (Elastomers, Block Copolymers, Amorphous Fractions) |
| Operating Principle | Temperature-Programmed Adsorption/Desorption Chromatography in High-Temperature Solvent (e.g., 1,2,4-Trichlorobenzene) |
| Detection Options | IR4/IR5 FTIR Detectors, Viscometer, Multi-Angle Light Scattering (MALS), MCT-enhanced IR Sensitivity |
| Automation | Robotic Autosampler (42-position), Fully Integrated Solvent Delivery, Online Filtration, Remote Diagnostics |
| Software Platform | Cirrus GPC/SEC + TGIC Module (Compliant with 21 CFR Part 11 Audit Trail & User Access Control) |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Sample Throughput | Up to 42 samples unattended with method-independent sequencing |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TGIC-200 for Block Polyolefin Characterization |
| Pricing | Available Upon Request |