Industry-specific Instruments
Filter
Showing 3961–3990 of 6344 results
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSL |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FT |
| Quotation | Upon Request |
| Temperature Range | –25 °C to 80 °C (standard) |
| Pressure Range | 10 bar (145 psi), 200 bar (2,900 psi), or 700 bar (10,000 psi) |
| Stirring Speed | 0–1,000 rpm |
| Titration Flow Rate | 0.3–30 mL/min |
| Optical Detection Sensitivity | 0.005 lux |
| Probe Interface | Threaded in-line mounting (NPT/BSP options available) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RC20 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR |
| Pricing | Upon Request |
| Reynolds Number | up to 80,000 (with 5 mm capillary, water) |
| Temperature Range | −10 °C to 80 °C |
| Maximum Pressure | 35 bar |
| Capillary Diameters | 3 mm and 5 mm |
| Capillary Length | 3.5 m |
| Sample Volume Requirement | 0.5 L – 3.0 L |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | WL |
| Pricing | Upon Request |
| Brand | PSS (Particle Sizing Systems) |
|---|---|
| Origin | USA |
| Model | AccuSizer 780 A7000 AD |
| Detection Principle | Single Particle Optical Sensing (SPOS) |
| Measurement Range | 0.5 µm – 400 µm |
| Sensor Type | LE Series (Light Obscuration + Light Scattering) |
| Channel Resolution | 512 channels |
| Maximum Sample Concentration | 1 × 10⁹ particles/mL |
| Particle Sensitivity | ≤10 ppt (parts per trillion, by volume) |
| Automation Features | Auto-dilution, auto-sampling, auto-cleaning, auto-calibration |
| Compliance Context | Designed for USP <788>, USP <789>, ISO 21501-4, ISO 13322-2, and FDA 21 CFR Part 11–ready data integrity workflows |
| Brand | Particle Sizing Systems (PSS) |
|---|---|
| Origin | USA |
| Model | AccuSizer 780 A7000 APS |
| Detection Principle | Single Particle Optical Sensing (SPOS) |
| Size Range | 0.5 µm – 400 µm |
| Resolution | 512-channel |
| Max Sample Concentration | 10¹¹ particles/mL |
| Compliance | USP <729>, ChP 2015, 21 CFR Part 11, cGMP |
| Automation | Integrated auto-sampling, two-step auto-dilution, auto-detection, data processing, and auto-cleaning |
| Brand | PULL |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Capacity | 500 mL |
| Working Pressure | 4 MPa or 20 MPa |
| Operating Temperature Range | −190 °C to +80 °C |
| Material | ASTM A312 TP316L Seamless Stainless Steel |
| Compliance | SH/T 0233–92, GB/T 13289–2014, GB/T 13290–2014, ASTM D1265, IP 197 |
| Optional Accessories | Bourdon-type pressure gauge, rupture disc, corrosion-resistant internal coating (e.g., SilcoNert® or Sulfinert®), push-to-connect quick couplings, PTFE/FEP-lined hoses |
| Brand | PULL |
|---|---|
| Model | PSD-650 |
| Origin | Shaanxi, China |
| Compliance | GB/T 7597, IEC 60475, ASTM D923 |
| Temperature Sensor | PT100 (±0.5 °C) |
| Power | Replaceable Battery |
| Design | Integrated, Explosion-Protected, Physically Isolated Sampling Circuit |
| Sampling Method | Continuous Flushing Enabled |
| Form Factor | Compact, Multi-Valve Integrated Unit |
| Application | In-Service Transformer Oil Sampling for Dissolved Gas Analysis (DGA) |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PULL |
| Price | USD 295 (FOB) |
| Working Pressure | 4–20 MPa |
| Burst Pressure | 7–38 MPa |
| Operating Temperature | −60 °C to +80 °C |
| Material | ASTM A213/A269 Grade 316L Stainless Steel |
| Volume Range | 100 mL to 5000 mL |
| Valve Configuration | Dual-end (single- and double-valve variants available) |
| Safety Features | Integrated rupture disc, explosion-proof needle valves |
| Optional Internal Coating | PTFE (per ASTM D1250 & ISO 4257) |
| Pressure Gauge Port | 1/4″ NPT, compatible with Class 1.6 analog or digital gauges |
| Accessories | Stainless steel 304 support stand, high-pressure metallic or nylon-reinforced polymer transfer hoses, push-to-connect quick couplings (ISO 8434-1 compliant) |
| Brand | PULL |
|---|---|
| Material | 316L Stainless Steel (ASTM A240/A276) |
| Working Pressure | 4–20 MPa |
| Burst Pressure | 7–38 MPa |
| Operating Temperature Range | −60 °C to +80 °C |
| Volume Options | 100–5000 mL |
| Compliance | SH/T 0233–92, SY/T ZJ1045, ASTM D1265, IP 191, ISO 4256 |
| Valve Configuration | Dual-end (single- or double-valve variants), equipped with explosion-proof rupture disc and precision needle valves |
| Optional Internal Coating | PTFE (per ASTM D7415) |
| Pressure Gauge | Bourdon-type, 0–25 MPa, Class 1.6 accuracy |
| Accessories | 304 Stainless Steel Support Stand, High-Pressure Flexible Hoses (Nylon or SS-braided) |
| Brand | PULL |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | pull-4-300 |
| Price | USD 295 (FOB) |
| Working Pressure | 4 MPa |
| Burst Pressure | ≥38 MPa |
| Operating Temperature Range | −60 °C to +80 °C |
| Material | ASTM A240 UNS S31603 (316L stainless steel) |
| Internal Coating Option | PTFE-lined |
| Valve Configuration | Dual-end, with standard and explosion-proof needle valves |
| Pressure Gauge | Integrated Bourdon-tube gauge (0–10 MPa, Class 1.6) |
| Volume | 300 mL |
| Compliance | SH/T 0233–1992, SY/T ZJ1045, ASTM D1265, IP 173, ISO 4256, EN 13757-3 |
| Brand | PULL |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pull-GP4-1000 |
| Capacity | 1 L |
| Material | Stainless Steel (AISI 316 or equivalent) |
| Design Pressure | 4 MPa |
| Compliance | GB 8570–2008 “Sampling of Laboratory Samples of Anhydrous Liquid Ammonia” |
| Pricing | USD 450 (FOB China, subject to quotation) |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 100A-001 |
| Pricing | Available Upon Request |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic Instrument |
| Model | CLDEE-CCACS2.0 |
| Price | USD 5,150 (approx.) |
| Brand | PULUODY |
|---|---|
| Model | DMA-135 |
| Principle | U-tube Oscillation Method |
| Measurement Range | 0.0000–3.0000 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Sample Volume | 2 mL |
| Measurement Time | ≤60 s |
| Display | 2.4″ Color LCD (320×240) |
| Power | 9 V alkaline battery (≈90 h operation) |
| Compliance | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, DB/T 1231–2010, SN/T 2383–2009 |
| Brand | PULUODY |
|---|---|
| Model | DMA-135D |
| Principle | U-tube Oscillation Method |
| Measurement Range | 0.0000–3.0000 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Repeatability | ±0.1 °C |
| Sample Volume | 2 mL |
| Sampling Method | Manual syringe or integrated pump (for liquids < 2000 mPa·s) |
| Measurement Time | ≤60 s |
| Display | 2.4″ color LCD, 320×240 pixels |
| Power | 9 V alkaline battery |
| Battery Life | ~90 h |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DMA-135D |
| Type | Portable Instrument |
| Compliance | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, SN/T 2383–2009, DB/T 1231–2010, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, IP 559–2008 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GREASE-CHECK |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Product Type | Portable Field Analyzer |
| Test Scope | Grease Consistency, Oil Bleed, Contamination Assessment, Color Stability, Shelf-Life Indication |
| Brand | PULUODY |
|---|---|
| Model | P-ICP |
| Origin | Shaanxi, China |
| Power Supply | 800–1600 W |
| Power Stability | ≤0.2% |
| Detection Limit | down to 1 ppb (µg/L) |
| Repeatability (RSD) | ≤1.5% |
| Stability (RSD) | ≤2.0% |
| Accuracy | ±3% (method-dependent) |
| Spectral Range | 190–800 nm |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Sample Volume Required | >1 mL |
| Operating Temperature | 20–45 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Elemental Coverage | ≥61 elements |
| Analysis Speed | ≥4 elements per minute |
| Linear Dynamic Range | 5 orders of magnitude |
| Certified Standards Compliance | ASTM D6595, ASTM D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | P-ICP |
| Product Category | Laboratory Instrument |
| Analytical Method | Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES) |
| Compliant Standards | ASTM D6595, ASTM D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Customizable Detection Channels | 1000 channels |
| Brand | PULUODY |
|---|---|
| Model | PDM-301A |
| Measurement Principle | Oscillating U-tube |
| Density Range | 0–3.0000 g/cm³ |
| Resolution | ±0.0001 g/cm³ |
| Repeatability | ±0.0002 g/cm³ |
| Temperature Control Accuracy | ±0.1 °C |
| Thermostatic Range | 15–30 °C |
| Power Supply | 220 V ±10%, 50 Hz |
| Sample Volume | 2–3 mL |
| Data Storage Capacity | >20,000 records |
| Display | LCD |
| Dimensions | 206 × 205 × 200 mm |
| Compliance | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, SN/T 2383–2009, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, IP 559–2008, JJG 1058–2010 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-0175B |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Heating Power | 1500 W |
| Temperature Control Accuracy | ±0.1 °C |
| Bath Capacity | 4 Test Positions |
| Oxygen Flow Control | Calibrated Precision Flowmeter |
| Cooling Method | Integrated Drain Valve + Forced-Air Fan |
| Operating Environment | Dark Chamber Enclosure |
| Compliance Standard | SH/T 0175 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-0193A |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Main Heating Power | 1500 W |
| Auxiliary Heating Power | 1200 W |
| Pressure Gauge Range | 0–1500 kPa |
| Pressure Gauge Accuracy | ±0.2% FS |
| Oil Bath Temperature Range | 100–160 °C |
| Oil Bath Temperature Stability | ±0.1 °C |
| Printer Model | TpuP-A40PB |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-0193A |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Main Heating Power | 1500 W |
| Auxiliary Heating Power | 1200 W |
| Pressure Gauge Range | 0–1500 kPa |
| Pressure Gauge Accuracy | ±0.2% FS |
| Oil Bath Temperature Range | 100–160 °C |
| Oil Bath Temperature Stability | ±0.1 °C |
| Printer Model | TpuP-A40PB |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | PLD-0201 |
| Price | USD 45,800 (FOB Shanghai) |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Calibration Standards | ISO 11171:2016, ISO 4402:1991, GB/T 18854–2002, JJG/T 066, NAS 1638, ISO 4406:2021 |
| Measurement Range | 0.01 µm – 1000 µm (configurable sensor modules) |
| Channel Resolution | Up to 1000 user-definable size channels |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Max. Viscosity Handling | ≤450 mm²/s |
| Operating Temp. | 20–65 °C (sample), 0–50 °C (ambient) |
| Pressure Range | –0.08 to 0.8 MPa |
| Data Storage | 3000+ tests onboard |
| Output Interface | RS232, touchscreen GUI, integrated thermal printer |
| Software | PULL 8.1 Multi-Language Platform (EN/CN/JP/KO/DE/FR/ES/IT/RU/AR) |
| Compliance Support | ASTM D6786, USP <788>, ISO 21501-4, GLP/GMP audit trail (optional), FDA 21 CFR Part 11 compliant mode (with optional license) |
| Brand | PULUODY |
|---|---|
| Model | PLD-0221A |
| Power Supply | AC 220 V |
| Power Consumption | 1750 W |
| Temperature Control Range | 15 °C to 20 °C |
| Temperature Stability | ±0.2 °C |
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-0248A |
| Origin | Shaanxi, China |
| Manufacturer | Yes |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Input Power | <1250 W |
| Cooling Range | Ambient to –40 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | 400 W |
| Refrigerant | Anhydrous Ethanol |
| Filtration Pressure | 1961 Pa (200 mmH₂O) |
| Filter Mesh | 363 mesh (≈40 µm nominal aperture) |
| Standard Compliance | SH/T 0248 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-0248B |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Input Power | <1250 W |
| Cooling Bath Temperature Range | Ambient to –40 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | 400 W |
| Refrigerant | Anhydrous Ethanol |
| Refrigeration System | Cascade Compressor-Based |