| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-FT1910 |
| Price Range | USD 150–15,000 |
| Brand | Spectra Invent (Chinainvent) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-KCR1875 |
| Price Range | USD 140–14,000 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-LR1838 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.5 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 520 mm × 330 mm × 570 mm |
| Net Weight | 9.5 kg |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-MI1885 |
| Price Range | USD 140 – 14,000 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-VIS1000 |
| Compliance Standard | GB/T 265 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Dimensions (W×D×H) | 545 × 370 × 500 mm |
| Weight | 18.4 kg |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-VIS1010A |
| Price Range | USD 150–15,000 |
| Brand | Spectra Invent (Chinainvent) |
|---|---|
| Origin | Beijing, China |
| Model | HX-VIS1050 |
| Power | 2000 W |
| Capillary Dispensing Accuracy | ±0.2 mL |
| Compliance | SH/T 0048 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-WR1847A |
| Price Range | USD 1,400 – 14,000 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-WS1840 |
| Price Range | USD 140–1,400 (FOB) |
| Weight | 26.7 kg |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-WSAA1835 |
| Power Consumption | 1200 W |
| pH Measurement Range | 0.00–14.00 |
| pH Accuracy | ±0.02 pH |
| pH Resolution | 0.01 pH |
| Repeatability | ≤1% |
| Stability | ±1% F.S. / 4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Control Range | Ambient to 100 °C |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HY-610 |
| Pricing | Available Upon Request |
| Impact Mass | 20.0 ± 0.2 kg |
| Impact Edge Geometry | Axe-shaped, Edge Radius R = 3.0 ± 0.1 mm |
| Impact Blade Dimensions | 60 mm length, included angle 90° ± 1°, tip radius 3.0 ± 0.1 mm |
| Cylindrical Anvil | Ø25 mm × H20 mm and Ø25 mm × H25 mm |
| Selectable Impact Energy | 200 ± 4 J or 100 ± 2 J |
| Clamp Assembly | Steel plate ≥150 mm × 150 mm × 19 mm thick, hardness 60 HRC |
| Anti-rebound Mechanism | Integrated mechanical lockout ensuring single-strike operation |
| Optional Ankle Protection Test Module | Guide mass 5000 ± 10 g |
| Force Measurement System | 120 kN load cell, resolution 0.1 kN |
| Calibration Documentation | CNAS-accredited calibration certificate per ISO/IEC 17025 |
| Brand | HENGYU |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HY-649 |
| Pricing | Upon Request |
| Test Speed | 5–30 cycles/min |
| Test Mass | 50 ± 0.5 kg per indenter |
| Number of Indenters | 2 |
| Control System | PLC with Touchscreen HMI |
| Pneumatic Actuator | SMC (Japan) |
| Integrated Thermal Printer | Chinese-language label output |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | ~210 kg |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HY-728 |
| Pricing | Available Upon Request |
| Friction Head Diameter | Φ30 mm |
| Stroke Lengths | 270 mm / 210 mm / 150 mm |
| Reciprocating Cycles Range | 0–999,999 |
| Cycle Rate | 26 cycles/min |
| Applied Pressure (Pelt Testing) | 19,700 ± 140 Pa |
| Brush Load (Blanket Shedding Test) | 1,098 g |
| Compliance Standards | QB/T 2790, GB/T 14254, GB 5460T |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HY-766 |
| Pricing | Upon Request |
| Roller Diameter | 150.0 ± 0.2 mm |
| Roller Length | ~500 mm |
| Lateral Traverse per Revolution | 4.2 ± 0.04 mm |
| Test Loads | 2.0 ± 0.1 N, 5.0 ± 0.1 N, 10.0 ± 0.2 N |
| Roller Speed | 40 ± 1 rpm |
| Abrasion Distance | 20.0 ± 0.1 m or 40.0 ± 0.2 m |
| Specimen Holder ID Range | 15.5–16.3 mm (adjustable) |
| Specimen Protrusion | 2.0 ± 0.2 mm |
| Holder Axis Tilt | 3° from vertical |
| Holder-to-Roller Longitudinal Offset | ±1 mm |
| Sandpaper Butt Joint Gap | ≤2 mm |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-767 |
| Price | USD 2,800 (FOB Tianjin) |
| Compliance | QB/T 4034–2010, QB/T 3805–1999 |
| Friction Head Dimensions | 50 mm × 29 mm |
| Mass Configurations | Wipe Test: 100 ± 5 g (foam + head) |
| Wash Test | 550 ± 10 g (felt + head) |
| Extra Wash Test | 100 ± 10 g |
| Brushing Test | 600 ± 10 g (brush + head) |
| Stroke Frequency | Wipe/Brushing: 30 ± 3 cycles/min |
| Wash | 120 ± 10 cycles/min |
| Extra Wash | 100 ± 10 cycles/min |
| Accessories | 2 friction heads with calibrated weights, 1 nylon-bristle brushing unit, 10 polyurethane foam pads (50 × 29 × 12 mm), 10 felt pads (50 × 29 × 6 mm), full technical manual |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-767D |
| Price | USD 720 (FOB Tianjin) |
| Compliance | QB/T 4034–2010, QB/T 3805–1999 |
| Stroke Length | 100 mm |
| Normal Load | 2 N |
| Traverse Speed | 30 mm/min |
| Friction Head Diameter | 16 mm (cylindrical, polished stainless steel) |
| Cycle Count Range | 1–9999 (LCD digital controller) |
| Motion Guidance | Precision linear rail with low-friction bushings |
| Moisture Control System | Adjustable manual mangle (two-roller squeeze unit), calibrated pressure range 0–500 kPa for standardized wet cloth moisture content |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | HY-769Q |
| Pricing | Upon Request |
| Temperature Range | Ambient to –30 °C (optional –50 °C) |
| Chamber Configuration | Horizontal insulated cold chamber with integrated refrigeration system |
| Chamber Material | Interior and exterior SUS 304 brushed stainless steel |
| Test Fixture | Standard-compliant shoe thermal insulation fixture per GB/T 21284–2007 |
| Included Accessories | Cold chamber unit, shoe-specific thermal insulation fixture, digital temperature data logger with calibrated Pt100 sensors, NIST-traceable calibration certificate (ISO/IEC 17025 accredited lab) |
| Key | Origin: Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HY-779 |
| Pricing | Upon Request |
| Resistance Range | 100 Ω to 1.99 × 10¹³ Ω |
| Accuracy | ±3% |
| Test Voltages | 10 V, 50 V, 100 V, 500 V |
| Inner Electrode | Stainless Steel Beads (Ø5 mm, Total Mass: 4 kg) |
| Outer Electrode | Conductive Contact Plate |
| Conductive Coating Probe Assembly | Three Metallic Probes (Radius: 3.0 ± 0.2 mm) |
| Calibration Certificate | CNAS-Accredited Laboratory Report |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-939CS |
| Pricing | Available Upon Request |
| Load Capacity Options | 2 / 5 / 10 / 50 / 100 / 200 kgf |
| Load Accuracy | ±0.5% of reading (within 0.4–100% of full scale) |
| Force Resolution | ±1/200,000 of maximum test load |
| Displacement Accuracy | ±0.5% of reading (within 2–100% FS) |
| Displacement Resolution | 0.005 mm |
| Large-Deformation Measurement Range | 10–800 mm |
| Large-Deformation Accuracy | ±0.5% of reading (within 2–100% FS) |
| Large-Deformation Resolution | 0.008 mm |
| Drive System | Panasonic 750 W AC servo motor + HIWIN precision ball screw + rotary encoder |
| Speed Range | 0.05–500 mm/min (optional 0.1–1000 mm/min) |
| Speed Accuracy | ±0.5% of set value |
| Test Stroke | 600 mm or 1000 mm (adjustable gauge length, fixture excluded) |
| Force Sensor Configuration | Up to four interchangeable load cells (max. 2 kN per channel) |
| Software Platform | Windows-based proprietary testing software with modular standard compliance, real-time multi-curve plotting, auto-calculation of mechanical parameters, and export to Excel, TXT, HTML |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDH-5901 |
| Cooling Method | Compressor-based refrigeration |
| Heating Method | Electric heating tube |
| Temperature Control | Digital PID controller |
| Temperature Range | 0–60 °C |
| Timing System | Digital timer |
| Power Supply | AC 220 V |
| Brand | SDL Atlas |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SDL Atlas |
| Pricing | Available Upon Request |
| Brand | aboni |
|---|---|
| Origin | Germany |
| Model | HT3 |
| Measurement Principle | Calcium Hydride Reaction (Direct Absolute Moisture Quantification) |
| Resolution | 0.01 mg / 1 ppm / 0.0001 % H₂O |
| Sample Type Compatibility | Plastic pellets, granules, powders, and molded polymer components |
| Interface | USB-connected to Windows PC |
| Output | Auto-generated PDF report with timestamp, sample ID, moisture content, and operator metadata |
| Calibration | Calibration-free across polymer types |
| Vacuum Requirement | None |
| Brand | Hyeyan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MZY8S |
| Output Interface | Standard BJ-26 Waveguide |
| Input Voltage | AC 380 V ±10% |
| Operating Frequency | 2450 MHz ±50 MHz |
| Control Architecture | Industrial PLC with HMI Touchscreen (Chinese-language UI) |
| Power Regulation | Automatic Multi-Step Power Level Switching |
| Monitoring | Real-time Magnetron Temperature Sampling with Fault Alarms |
| I/O Interfaces | Multiple Peripheral Control Ports |
| Compliance | Designed for integration into CE-compliant microwave processing systems (user-responsible final system certification) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EnSURE™ |
| Price | USD 3,800 (approx.) |
| Function Type | Single-Parameter Detection |
| Sample Format | Single-Sample Dedicated |
| Wavelength Range | 400–680 nm |
| Detection Time | <15 s |
| Repeatability | <5% RSD |
| Detection Channels | 1 |
| ATP Detection Limit | 0.1 fmol (1 × 10⁻¹⁶ mol) |
| Dynamic Range | 0–9999 RLU |
| Data Storage Capacity | 2000 records |
| Calibration | Auto-calibration within 60 s on power-up |
| Power Supply | Two AA alkaline batteries |
| Weight | 260 g |
| Display | Backlit LCD |
| Brand | Hygiena |
|---|---|
| Origin | USA |
| Model | Pi-102 |
| Detection Limit | 1 × 10⁻¹⁸ mol ATP/assay |
| Measurement Time | Adjustable from 0.2 to 100 s (default 5 s) |
| Output Units | RLU (Relative Light Units) and fg (femtograms of bacterial ATP) |
| Memory Capacity | 800 stored results with category tagging |
| Display | LCD |
| Dimensions | 208 × 105 × 57 mm (L × W × H) |
| Weight | 1.5 kg |
| Measurement Range | 0–3,000,000 RLU |
| Accuracy | ±5% |
| Power Supply | Rechargeable Ni/Cd battery + AC adapter |
| Connectivity | Real-time data transmission to PC via USB |
| Brand | Hygiena |
|---|---|
| Origin | United Kingdom |
| Model | SystemSURE II |
| Detection Range | 0–9999 RLU |
| Detection Time | 15 s |
| Resolution | 1 RLU |
| Accuracy | ±5 RLU or ±5% |
| Data Storage | 500 results |
| Operating Temperature | 5–40 °C |
| Relative Humidity (Operating) | 20–85% non-condensing |
| Storage Temperature | −10–40 °C |
| Battery | 2 × AA (alkaline, 2600 mAh |
| Interface | EIA-232 compatible serial port |
| Power Life | ≥6 months at 20 °C (6000 tests) |
| Brand | Hygiena |
|---|---|
| Origin | United Kingdom |
| Model | SystemSURE PLUS |
| Detection Range | 0–9999 RLUs |
| Sensitivity | up to 2×10⁻¹⁶ mol ATP |
| Response Time | 15 s (calibration), 15 s (measurement) |
| Display | 45 mm × 45 mm LCD |
| Weight (with batteries) | 260 g |
| Power | 2 × AA alkaline batteries (≈3000 tests per set) |
| Data Storage | 2000 results |
| User Accounts | ≥200 |
| Test Protocols | ≥5000 |
| Detection Programs | ≥100 |
| RLU Resolution | 1 RLU |
| Blank Background | 0–1 RLU |
| ATP Recovery Rate | 92% |
| Swab Shelf Life | ≥12 months at 2–8 °C |
| Compliance | CE-marked, ISO 22000-aligned, validated for HACCP/SSOP verification |
| Brand | Hygiena |
|---|---|
| Origin | USA |
| Model | SystemSURE PLUS™ |
| Detection Range | 0–9999 RLU |
| Resolution | 1 RLU |
| Measurement Time | 15 s |
| Accuracy | ±5% or ±5 RLU |
| Data Storage Capacity | 2000 results |
| Operating Temperature | 5–40 °C |
| Relative Humidity (Operating) | 20–85% non-condensing |
| Storage Temperature | −10–40 °C |
| Relative Humidity (Storage) | 20–95% non-condensing |
| Dimensions (W×H×D) | 72 × 191 × 32 mm |
| Weight (with batteries) | ~269 g |
| Power Supply | 2 × AA (LR6/E91), alkaline (1.5 V nom.) or rechargeable NiMH/NiCd (1.2 V nom.) |
| Battery Life | ≥6 months at 20 °C (alkaline, standby) |
| Interface | EIA-232 (RS-232) compatible |
| User-Programmable Limits | 251 |
| Customizable Protocols | 251 |
| Program Groups | 20 |
| User ID Support | Yes |
| Software Included | SURE Trend™ v4.x |
| Key | Brand: Ichihashi Seiki |
|---|---|
| Origin | Japan |
| Model | Autotab-200 |
| Max Compression Force | 40 kN |
| Max Tablet Diameter | Φ16 mm (IPT/TSM-B) / Φ23 mm (IPT/TSM-D) |
| Fill Depth | ≈18 mm |
| Tooling Standard | IPT/TSM-B or D |
| Cycle Time | 12–20 sec/tablet |
| Motor Power | 0.8 kW |
| Voltage | 100/110 V or 200/220 V |
| Weight | 180 kg |
| Dimensions (W×D×H) | 400 × 500 × 1540 mm |
| Hopper Capacity | 100 mL |
| Compliance | IPT, TSM, EU standard tooling compatible |
| Brand | Ichihashi Seiki |
|---|---|
| Origin | Japan |
| Model | Autotab-200TR |
| Maximum Compression Force | 40 kN |
| Max Tablet Diameter | Φ16 mm (IPT/TSM-B) / Φ23 mm (IPT/TSM-D) |
| Fill Depth | ~18 mm |
| Tooling Standard | IPT/TSM-B or D |
| Cycle Time | 30–60 sec per tablet |
| Motor Power | 0.8 kW |
| Voltage | 100/110 V or 200/220 V |
| Weight | 240 kg |
| Dimensions (W×D×H) | 600 × 500 × 1540 mm |
| Hopper Capacity | 70 mL × 3 |
| Safety Interlock | Three-side mechanically and programmatically interlocked doors |
| Data Export | USB interface with proprietary PC software for compression force, ejection force, and cycle log export |