Industry-specific Instruments
Filter
Showing 2251–2280 of 6344 results
| Brand | HORIBA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Evaluator LT Series |
| Price Range | USD 135,000 – 270,000 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Custom-configurable XRF-based In-line Monitor |
| Pricing | Available upon consultation |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | SLFA-20 |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Detection Limit | 20 ppm (3σ) |
| Measurement Range | 0–5 wt% (extended to 0–90 wt% with matrix correction) |
| Repeatability | ≤15 ppm (at 1 wt% S) |
| Analysis Time | 1–600 s (user-selectable) |
| Sample Volume | 4–10 mL |
| Dimensions | 250 × 407 × 138 mm |
| Weight | 8 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH at 5–31 °C, linearly decreasing to 50% RH at 40 °C |
| Spectral Range | 0–10 keV |
| Output Interface | RS-232C |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | 80 VA |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | SLFA-2100/2800 |
| Detection Principle | Wavelength-Dispersive X-ray Fluorescence (WDXRF) |
| Analyte | Total Sulfur in Petroleum Products |
| Detection Range | ≤5 ppm (at 1% sample mass loading) / ≤1.6 ppm (at 0% baseline) |
| C/H Correction Error | ±50 ppm per 1% C/H ratio (at 1% sample loading) |
| Detection Limit | <5 ppm |
| Calibration Curves | Up to 5 stored |
| Calibration Points | 2–20 points using certified reference materials |
| Sample Volume | 4–10 mL |
| Measurement Time | 10–600 s (user-selectable) |
| Sample Capacity | 1 position (SLFA-2100) / 8-position automated turntable (SLFA-2800) |
| Operating Temperature | 5–35 °C |
| Relative Humidity | 30–85 % RH |
| Energy Range | 0–10 keV |
| Output Interface | RS-232C |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | 150 VA |
| Dimensions (W×D×H) | 430 × 500 × 230 mm |
| Weight | ~21 kg (SLFA-2100) / ~24 kg (SLFA-2800) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SLFA-60 |
| Detection Target | Total Sulfur |
| Measurement Principle | X-ray Fluorescence (XRF) Spectrometry |
| Detection Range | 0–10 wt% S |
| Detection Limit | 5 ppm |
| Precision | ±5 ppm (at 1.0% S), ±1.6 ppm (at 0% S) |
| Sample Volume | 4–10 mL per analysis |
| Measurement Time | Adjustable from 10 to 600 seconds |
| Sample Capacity | 8-position automated rotary stage |
| Sample Holder | Disposable liquid-specific film-bottom cup |
| Calibration Flexibility | Up to 20 calibration points across 5 stored curves (linear/nonlinear) |
| Environmental Operating Range | 5–35 °C, 30–85% RH |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | 150 VA |
| Interface | RS-232C standard serial port |
| Dimensions | 430 × 500 × 230 mm |
| Weight | ~24 kg |
| Compliance | ASTM D4294, ISO 8754, JIS K2541 & B7995, GB/T 17040–1997, GB/T 17060–1998, SN/T 0509–1995 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HSA |
| Pricing | Available Upon Request |
| Max Heating Temperature | 230 °C ±0.3% |
| Bidirectional Measurement | MD & CD |
| Thermal Expansion Range | up to 27% |
| Thermal Shrinkage Range | up to 5% |
| Sample Dimensions | 60 mm × 200 mm (MD or CD) |
| Resolution | 0.013% |
| Power Supply | 220 V / 50 Hz |
| Dimensions (H×W×D) | 295 mm × 280 mm × 320 mm |
| Weight | 15 kg |
| Brand | Hongtuo |
|---|---|
| Model | HT-1633-BA-4 |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | (120 ±10) °C/h, (12 ±1) °C/6 min, (50 ±5) °C/h, (5 ±0.5) °C/6 min |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Deflection Measurement Range | 0–10 mm |
| Deflection Resolution | ±0.001 mm |
| Specimen Stations | 4 independent test positions |
| Standard Span | 64 mm or 100 mm (per ISO 75 & ASTM D 648) |
| Load Bar + Platter Mass | 68 g |
| Heating Medium | Methyl Silicone Oil |
| Cooling Method | Integrated Forced-Air or External Water Cooling |
| Heating Power | 1.5 kW |
| Oil Bath Capacity | ~13 L |
| Dimensions (L×W×H) | 650 × 460 × 840 mm |
| Brand | hte |
|---|---|
| Origin | Germany |
| Product Type | Lab-scale High-Throughput Sintering Reactor |
| Configuration | 4×36 or 2×25 Independent Sample Channels |
| Crucible Capacity | Customizable (e.g., 36 × 10 g) |
| Max Operating Temperature | 1050 °C |
| Atmosphere Control | Oxidizing (O₂), Reducing (e.g., Syngas), Inert (N₂/Ar) |
| Temperature Gradient Resolution | ±0.5 °C per Zone |
| Heating/Cooling Rate Control | Programmable (0.1–20 °C/min) |
| Gas Flow Precision | ±1% FS Mass Flow Control |
| Data Acquisition | Real-time T, P, gas composition, dwell time, ramp profiles |
| Compliance | GLP-ready architecture, FDA 21 CFR Part 11–compatible audit trail (via hteControl v5.2) |
| Brand | HTE |
|---|---|
| Origin | Germany |
| Type | High-Throughput Co-Precipitation Reactor System for Battery Cathode Precursor Synthesis |
| Reactor Volume | 2 L or 10 L (customizable) |
| Operation Modes | Continuous, Batch with Concentrator, Heavy-Duty Batch with Concentrator |
| Max Operating Temperature | 70 °C at Ambient Pressure |
| Feed Types | Aqueous Metal Salt Solutions, Precipitants, Dopants, Dry Powders |
| Integrated Sensors | Real-time pH Monitoring, In-line Particle Size Measurement (e.g., laser diffraction), Automated Liquid Sampling |
| Software Suite | hteControl (experiment automation & data acquisition), Custom GUI, GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025-aligned R&D environments |
| Safety | Lab-in-Lab containment architecture with redundant safety sensors, 24/7 unattended operation certified |
| Material Output per Run | 1–5 kg of precursor (e.g., NMC, LFP, Prussian Blue analogues) |
| Scalability | Process parameters validated from lab-scale to pilot-scale with <±5% deviation in PSD and stoichiometry |
| Brand | Huaai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic (China-Made) |
| Model | Fuel Hydrogen Analysis System |
| Pricing | Upon Request |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GC-9560-GAS |
| Pricing | Upon Request |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Target Analytes | H₂, O₂, CO, CO₂, C₂H₂, CH₃OH, PH₃ |
| Detection Limits (ppm) | H₂/O₂/PH₃ ≤ 0.01 |
| Compliant Standards | GB/T 7715–2003, GB/T 7716–2002, GB/T 3393–2009, GB/T 3394–2009, GB/T 12701–1990, GB/T 3396–2002 |
| Column Configuration | Four-Valve, Five-Column Center-Cut & Back-Flush System |
| Sample Valve | Purge-Protected 6-Port or 10-Port Rotary Valve |
| Auxiliary Components | Integrated He Purifier, Zero-Dead-Volume Sampling Valve |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-3011SK |
| Detection Method | Cleveland Open Cup (COC) Method |
| Temperature Range | Ambient to 400 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤3 °C |
| Resolution | 0.1 °C |
| Heating Rate | 14–17 °C/min (from ambient to 56 °C below preset flash point) |
| Ignition | Automatic electronic ignition (silicon nitride igniter) |
| Cooling | Forced-air cooling |
| Power Consumption | ≤500 W |
| Data Storage | 1000 test records with date-based retrieval |
| Communication | RJ45 (LIMS integration), USB (firmware update & data export) |
| Power Supply | AC 170–264 V, 50/60 Hz or AC 120 V ±10%, 60 Hz ±1 Hz |
| Dimensions (Controller) | 270 × 170 × 130 mm, ~2.0 kg |
| (Testing Unit) | 480 × 245 × 280 mm, ~18.0 kg |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HK-3013SB |
| Detection Method | Closed Cup (ASTM D93 / ISO 2719 / GB/T 261) |
| Temperature Range | Ambient to 400 °C |
| Accuracy | ±1 °C (FP ≤ 110 °C), ±2 °C (FP > 110 °C) |
| Repeatability | 2 °C (FP ≤ 110 °C), 4 °C (FP > 110 °C) |
| Reproducibility | ≤10 °C |
| Resolution | 0.1 °C |
| Heating Rate | Step A: 5–6 °C/min |
| Step B | 1.0–1.5 °C/min |
| Ignition | Automatic electronic ignition (silicon nitride igniter) |
| Cooling | Forced-air cooling |
| Power Supply | AC (170–264) V, 50/60 Hz or AC (120±10%) V, 60±1 Hz (configurable at order) |
| Power Consumption | ≤300 W |
| Dimensions (Controller) | 270 × 170 × 130 mm, ~2.0 kg |
| (Test Unit) | 480 × 245 × 280 mm, ~18.0 kg |
| Data Storage | 1000 test records with date-based retrieval |
| Interfaces | RJ45 (LAN for LIMS integration & firmware update), USB (software update & data export) |
| Compliance | Designed to meet ASTM D93, ISO 2719, and GB/T 261 requirements for closed-cup flash point determination |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | HK-3020ND |
| Price Range | USD 4,200 – 7,000 |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | HK-3031PK |
| Pricing | Upon Request |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HK-3040YN |
| Price Range | USD 1,400 – 4,200 |
| Temperature Control Range | Ambient to 100 °C |
| Bath Uniformity | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Stirring Speed | 1250 rpm |
| Heating Power | Main 800 W + Auxiliary 300 W |
| Capillary Mounting Positions | 4 |
| Sample Trials per Run | 1–6 |
| Data Storage Capacity | 1000 test records |
| Display | Color LCD touchscreen (Chinese/English UI) |
| Connectivity | Standard USB + RJ-45 Ethernet (optional RS-232) |
| Dimensions (L×W×H) | 400 × 450 × 650 mm |
| Weight | 25 kg |
| Compliance | GB/T 265–1988 (equivalent to ASTM D445 & ISO 3104) |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-3040YN |
| Price Range | USD 1,400 – 4,200 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Configuration | Dual-layer cylindrical stainless-steel bath |
| Number of Test Positions | 4 |
| Stirring Speed | 1250 rpm |
| Heating Power | Main heater 800 W + Auxiliary heater 300 W |
| Capillary Mounting Capacity | 2 capillaries simultaneously |
| Capillary Sizes Supplied | 0.8 mm, 1.0 mm, 1.2 mm, and 1.5 mm nominal bore |
| Data Storage | Up to 1000 test records with date/time stamping |
| Interface Options | Ethernet and USB 2.0 |
| Display | Color LCD touchscreen with bilingual (Chinese/English) UI |
| Built-in Thermal Printer | Yes, auto/manual print mode |
| Power Supply | AC 198–242 V, 50–60 Hz or AC 120 V ±10%, 60 Hz ±1 Hz (configurable at order) |
| Dimensions (W×D×H) | 400 × 450 × 650 mm |
| Net Weight | 25 kg |
| Operating Environment | 0–40 °C, RH ≤85%, non-corrosive, low-vibration, EMI/EMF-shielded ambient |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-3080XS |
| Price Range | USD 4,200 – 7,000 |
| Product Category | Laboratory Instrument |
| Test Parameter | Rust Inhibition Performance (Rust Rating) |
| Compliance Standard | GB/T 11143–2008 |
| Display | 800×480 Color TFT Touchscreen (Bilingual: English/Chinese) |
| Sample Stations | 4 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Timing Range | 0–99 h (programmable) |
| Stirring Speed | 1000 rpm |
| Power Supply | AC 120 V / 220–240 V, 50/60 Hz |
| Max Power Consumption | ≤2650 W |
| Dimensions (L×W×H) | 490 × 403 × 622 mm |
| Net Weight | 65 kg |
| Safety Features | Auto Liquid-Level Detection, Dry-Run Protection, Over-Temperature Alarm |
| Interface | USB for firmware update |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | HK-3160SZ |
| Pricing | Upon Request |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2600 |
| Pricing | Available Upon Request |
| Explosion-Proof Certification | Certified per GB 3836.1/GB 3836.4 (Ex ib IIB T4 Gb) |
| Compliance Standard | GB 20952–2020 Emission Standard for Atmospheric Pollutants from Gasoline Filling Stations |
| Environmental Sensors | Integrated temperature, relative humidity, and barometric pressure measurement |
| Connectivity | Bluetooth, USB-C, USB-A (data export & firmware update), U disk interface |
| Positioning | Built-in BeiDou GNSS module + manual coordinate entry |
| Power Options | AC adapter or optional rechargeable Li-ion battery (≥8 h runtime) |
| Control Interface | Intrinsically safe explosion-proof handheld controller (wireless, ATEX/IECEx-equivalent certified for Zone 1/21) |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HC3500 |
| Price | USD 3,650 (FOB Jiangsu) |
| Temperature Range | Ambient to 1000 °C |
| Display | 7-inch TFT LCD Touchscreen |
| Sample Capacity | 4 parallel positions |
| Heating Zone Length | 260 mm |
| Furnace Tube Dimensions | Ø45 mm × 600 mm |
| Chamber Dimensions | Ø45 mm × 350 mm |
| Heating Element | High-Temperature Alloy Resistance Wire |
| Temperature Control | PID with Multi-Stage Programmable Ramp/Soak Profiles |
| Temperature Uniformity | ±5 °C across working zone |
| Sensor Resolution | 0.1 °C |
| Gas Control | Dual Mass Flow-Controlled Inlets (N₂ only), Auto-Switching per Program Step |
| Cooling Method | Lid-Open Forced-Air Rapid Cool-down |
| Power Supply | AC 220 V / 50 Hz, 600 W |
| Overall Dimensions | 416 × 325 × 289 mm |
| Compliance | GB/T 3515–2005, GB/T 13021–1991, GB/T 2951.41–2008, ISO 6964:2015, IEC 60811-4-1:2012, ASTM D1606 (referenced), JTG E50 T1165–2006 |
| Brand | Huiron |
|---|---|
| Model | HRH-BRM-2100 |
| Origin | Beijing, China |
| Tidal Volume Range | 0–1000 mL |
| Accuracy | ±5% of full scale or ±1 mL (whichever is greater) |
| Power Supply | 220 V, 50 Hz |
| Dimensions | 70 × 35 × 62 cm |
| Weight | 35 kg |
| Compliance | USP <601>, Ph. Eur. 2.9.43, ChP 2020 Vol. IV <0951> |
| Predefined Breathing Profiles | Adult / Pediatric / Infant / Neonatal |
| Customizable Parameters | Tidal Volume, Breathing Frequency, I:E Ratio, Flow Profile Shape, Cycle Count |
| Real-time Output | Flow Rate Curve, Tidal Volume Curve, Respiratory Parameter Summary |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorFlex EZ |
| Measurement Principle | 45°/0° Geometry Reflectance Spectrophotometry |
| Illuminant | D65, A, C, F2, F7, F11 |
| Observer Angle | 10° |
| Wavelength Range | 400–700 nm |
| Optical Resolution | 10 nm |
| Repeatability | ΔE*ab < 0.08 (for white tile, 10 readings) |
| Interface | USB 2.0 |
| Software Compatibility | EasyMatch QC v5.0+ |
| Compliance | ASTM E308, ISO 7724, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XE |
| Application Domain | Food & Edible Oil Quality Analysis |
| Color Space Support | CIE L*a*b*, Hunter L,a,b, YI (ASTM D1925 & E313), WI (ASTM E313), ΔE*ab, ΔE00, etc. |
| Illuminant Options | D65, A, C, F2, F7, F11 |
| Observer Angle | 10° |
| Measurement Geometry | d/8° (diffuse illumination / 8° viewing, SCI & SCE modes) |
| Repeatability | σ ≤ 0.02 ΔE*ab (white tile, 10 readings) |
| Portability | Benchtop |
| Compliance | ISO 5-4:2022, ASTM E308, CIE No. 15:2018, FDA 21 CFR Part 11 ready (with optional software module) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabScan XE |
| Pricing | Available Upon Request |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LSXE Tomato |
| Optical Geometry | 45°/0° (45-degree annular illumination, 0-degree viewing) |
| Aperture Size | 44 mm |
| Compliant Standards | ASTM E313-96, USDA Tomato Color Grading Protocol, BCR Certified Reference Tiles |
| Built-in Tomato-Specific Indices | Tomato Color Score, Tomato Juice Score, Tomato Catsup Score, Tomato Paste Score, Tomato Sauce Score, Lycopene Estimation (457 nm Brightness), A/B Ratio, Hunter L,a,b (C/2° & D65/10°) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectraTrend-HT Online Paper Color & Height Measurement System |
| Price Range | USD 26,000 – 39,000 (FOB) |
| Measurement Principle | Reflectance-based spectrophotometry (CIE-compliant, D65/10°) |
| Optical Geometry | 45°/0° (annular illumination, directional viewing) |
| Spectral Bandwidth | 10 nm |
| Wavelength Range | 400–700 nm |
| Measurement Distance | Up to 100 mm (4 in) |
| Sampling Rate | 5 Hz |
| IP Rating | NEMA 4 / IP56 |
| Interface | Ethernet (TCP/IP), PLC-compatible digital I/O |
| Software Platform | HunterLab EasyMatch QC v5.0+ (FDA 21 CFR Part 11 compliant audit trail option) |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-CP1260A |
| Power Consumption | 1500 W |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-EL1920 |
| Price Range | USD 150–15,000 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-FP1120 |
| Price Range | USD 150–15,000 |
| Test Method | Cleveland Open-Cup (COC) |
| Operation Mode | Manual |
| Temperature Range | Ambient to 400 °C |
| Ignition Method | Manual Flame Application |
| Repeatability | ≤4 °C |
| Applicable Standard | GB/T 3536 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Resolution | 0.1 °C |
| Reproducibility | ≤8 °C |
| Heating Rate | Compliant with GB/T 3536 Annex A |