Industry-specific Instruments
Filter
Showing 2191–2220 of 6344 results
| Brand | Heubach |
|---|---|
| Origin | Germany |
| Model | Dustmeter |
| Instrument Type | Seed Coating Dust Release Tester |
| Dust Measurement Principle | Controlled-Abrasion Air-Flow Filtration |
| Sample Rotation Speed | Adjustable (0–60 rpm) |
| Airflow Control | Programmable Volume (L) or Duration (s) |
| Filtration Efficiency | Standard Glass Fiber Filter (99.97% @ 0.3 µm) |
| Sample Mass Range | 1–100 g |
| Balance Resolution | 0.1 g |
| Operating Temperature Range | Ambient to 80 °C |
| Compliance | EN 15203, EU Directive 85/157/EEC (Feed Additives), ISO 17025-Compliant Testing Environment |
| Upgrade Path | Modular I → II → III Configuration |
| Brand | Hexin Mass Spectrometry |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Model | TAPI-TOF 1000 |
| Pricing | Available Upon Request |
| Detection Method | Thermal-Assisted Plasma Ionization (TAPI) coupled with Time-of-Flight Mass Spectrometry |
| Measurement Range | Customizable per pesticide analyte (validated per EU SANTE/11312/2021 & GB 2763-2021 guidelines) |
| Channel Capacity | High-throughput single-channel sequential analysis |
| Detection Channels | Single ionization source with multiplexed spectral acquisition |
| Measurement Uncertainty | Compliant with ISO/IEC 17025:2017 for qualitative screening |
| Limit of Detection (LOD) | Sub-ng/g level for >300 priority pesticides in matrix-matched calibration |
| Brand | Heyer Aerotech (SIGAS/Schütz Meßtechnik) |
|---|---|
| Origin | Germany |
| Product Type | Medical Gas Outlet Terminal |
| Compliance | DIN EN ISO 7396-1 |
| Mounting Options | Wall-mounted (load-bearing & non-load-bearing), equipment rail, ICU headwall, ceiling-suspended pendants, gas supply boxes from multiple OEMs |
| Gas Interface | Dual-seal, keyed coupling system preventing cross-gas misconnection |
| Certification | CE-marked per EU MDR 2017/745 |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | HFN-B |
| Measurement Principle | Capillary Efflux (ASTM D445 / ISO 3104 compliant) |
| Temperature Control | 40 °C ± 0.1 °C |
| Sample Volume | 80 µL |
| Measurement Time | ≤ 30 s per test |
| Viscosity Range | 2–1000 mm²/s (cSt) at 40 °C |
| Calibration | Multi-point viscosity standard calibration (certified mineral oil standards) |
| Display | 7-inch capacitive touchscreen |
| Power | Rechargeable Li-ion battery (≥ 8 h continuous operation) |
| Cleaning | Solvent-free — dry wipe with lint-free industrial cloth |
| Compliance | Designed to support ASTM D445, ISO 3104, and ISO 2909 procedures for kinematic viscosity determination |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LAS |
| Pricing | Available Upon Request |
| Brand | VINCI |
|---|---|
| Origin | France |
| Model | FluidEval 500 |
| Application | Reservoir Fluid PVT Analysis under In-Situ Conditions |
| Compliance | Designed for ASTM D7169, ISO 12213-2, and API RP 44 alignment |
| Temperature Range | Up to 200 °C |
| Pressure Range | Up to 140 MPa |
| Sample Volume | 5–50 mL |
| Measurement Principle | Constant-Composition Expansion (CCE), Differential Liberation (DL), Flash Separation, and Swelling Tests via Precision Piston-Cylinder Volumetry & Optical Phase Detection |
| Brand | Hinds Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | YP-150SDP |
| Chamber Volume | 150 L |
| Internal Dimensions | 600 × 405 × 620 mm |
| External Dimensions | 800 × 910 × 1630 mm |
| Temperature Range (Dark) | 0–65 °C |
| Temperature Range (Illuminated) | 10–65 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 40–95 %RH |
| Humidity Uniformity | ±0.5 %RH |
| Illuminance Range | 0–4500 lx (adjustable) |
| Illuminance Accuracy | ≤ ±500 lx |
| Cooling System | Air-cooled, hermetic Danfoss compressor |
| Refrigerant | R404A/R23 |
| Control Interface | TEMI880 programmable touchscreen controller (Korean origin) |
| Temperature Sensor | Pt100 platinum resistance thermometer |
| Humidity Sensor | Imported high-accuracy capacitive transducer |
| Air Circulation | Optimized tangential fan system with rear-mounted centrifugal blower |
| Safety Protections | Compressor overheat, overload, water shortage, overtemperature, electrical short-circuit |
| Compliance | GB 10586–2006, Chinese Pharmacopoeia (2010 Edition) Stability Guidelines, ICH Q1A(R2), WHO TRS 953 Annex 2, FDA Guidance for Industry — Stability Testing of Drug Substances and Products |
| Brand | Hinds Instruments |
|---|---|
| Origin | Shanghai, China |
| Model Variants | YP-SD, YP-SDP, YP-GSD, YP-GSP150/250/500/1000 |
| Chamber Volume | 150 L / 250 L / 500 L / 1000 L |
| Temperature Range (Dark) | 0–65 °C |
| Temperature Range (Illuminated) | 10–65 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 40–95 %RH |
| Humidity Uniformity | ±0.5 %RH |
| Illuminance Range | 0–4500 lx (adjustable) |
| Illuminance Accuracy | ≤±500 lx |
| Cooling System | Hermetic Danfoss Compressor (R404A/R23) |
| Control Resolution | 0.1 °C / 0.1 %RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Safety Protections | Compressor Overheat, Overload, Low-Water, Overtemperature, Electrical Short-Circuit |
| Brand | Hinds Instruments |
|---|---|
| Origin | Shanghai, China |
| Model Variants | YP-SD150, YP-SD250, YP-SD500, YP-SD1000, YP-SDP150, YP-SDP250, YP-SDP500, YP-GSP150, YP-GSP250, YP-GSP500 |
| Capacity | 150 L / 250 L / 500 L / 1000 L |
| Temperature Range | 0–65°C (dark), 10–65°C (with illumination) |
| Temperature Uniformity | ±0.5°C |
| Humidity Range | 30–95% RH |
| Humidity Uniformity | ±0.5% RH |
| Illuminance Range | 0–6000 lx (adjustable) |
| Illuminance Accuracy | ≤ ±500 lx |
| Control Resolution | 0.1°C / 0.1% RH |
| Refrigeration System | Hermetic Danfoss compressor (R404A/R23 refrigerant) |
| Cooling Capacity | 90–150 W @ −25°C to +55°C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Safety Protections | Compressor overheat, overload, water shortage, overtemperature, electrical short-circuit |
| Compliance | Chinese Pharmacopoeia (2010 Edition) Stability Guidelines, GB/T 10586–2018 Environmental Test Equipment General Specifications |
| Construction | Mirror-finish SUS304B interior, arc-shaped cabinet design, double-glazed vacuum-insulated observation window |
| Air Circulation | Optimized ducted convection system for high spatial uniformity |
| Standard Accessories | 2 adjustable stainless-steel shelves, left-side test lead port, PID-tuned Fuji controller with touchscreen interface |
| Brand | Hinds Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | YP-TSD-TSDP-TGSD / TGSP150 / TGSP250 / TGSP500 / TGSP1000 |
| Temperature Control Range | 10–65°C (±0.5°C fluctuation, ±2.0°C uniformity) |
| Humidity Control Range | 40–95% RH (±3% RH fluctuation, ±5% RH uniformity) |
| Light Chamber Illumination | 0–6000 lux (±500 lux deviation) |
| Chamber Volumes | A/B (100 L each), C (200 L) |
| Internal Dimensions (W×D×H mm) | 500×450×450 (A/B), 500×450×1000 (C) |
| External Dimensions (W×D×H mm) | 1300×900×1800 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 4.0 kW |
| Construction | Mirror-finish 304 stainless steel interior, powder-coated steel exterior |
| Refrigeration | Three independent imported hermetic compressors |
| Humidity Sensing | Imported capacitive humidity sensors |
| Controller | Imported programmable temperature/humidity controllers (A/B), dedicated light-temperature controller (C) |
| Data Output | Integrated dot-matrix thermal printer |
| Data Backup | USB flash drive storage |
| Safety Protections | Independent over-temperature cut-off, compressor overheat, fan overheat, high-pressure shutdown, overload protection, water shortage alarm |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | HK-265 |
| Price | Upon Request |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | 20–100 °C |
| Temperature Stability | ±0.1 °C (optional ±0.01 °C with HK-265A configuration) |
| Heating Power | 1800 W |
| Illumination | LED with silicone diffuser panel |
| Sample Holders | 4 capillary viscometer clamps |
| Safety Features | Liquid-level protection sensor |
| Cooling Interface | Dedicated external chiller port |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Model | HK-6536A |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Heating Power | 0–1000 W (continuously adjustable) |
| Bath Temperature Range | 0–60 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Voltage Regulation | Solid-State Phase-Angle Controller (stepless) |
| Stirring Method | Motor-Driven Stirring |
| Flask Capacity | 125 mL |
| Graduated Cylinder Capacity | 100 mL |
| Ambient Operating Conditions | 10–40 °C, ≤85% RH |
| Distillation Configuration | Single-Tube, Ambient Pressure |
| Compliance | GB/T 6536 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | HK-6536C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 3800 W |
| Temperature Control | Digital PID Controller |
| Temperature Accuracy | ±0.5 °C |
| Condensate Bath Range | 0–60 °C |
| Air Bath Range | 1 °C to Ambient |
| Cooling Method | Forced-Air with Dual Electric Coolers |
| Stirring | Pump-Circulated Coolant |
| Heating Element | Quartz Tube Heaters |
| Thermometer Fixation | Silicone Rubber Stopper |
| Air Chamber | Auto-Temperature Regulation & Digital Display |
| Illumination | Dual LED Auxiliary Lighting |
| Operating Environment | 5–40 °C, RH ≤85% |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | MFS-3-PRO |
| Vacuum Pump Type | Integrated High-Vacuum Silent Diaphragm Pump |
| Filtration Capacity | Up to 3 Independent Channels |
| Data Storage | 6400 Sets of Sampling Records |
| Sterilization Compatibility | 121 °C Autoclavable (Stainless Steel Filter Cups & Holders) |
| Display | HD Touchscreen LCD |
| Language Interface | English & Chinese |
| Compliance | GB 8538–2016, GB/T 5750.12–2006, GB/T 18204.5–2013, GB/T 19298–2014, ChP 2020 Microbial Limits Test |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | NC Series |
| Detection Method | Enzyme Inhibition Spectrophotometry |
| Measurement Range | 0–100% inhibition rate |
| Channel Count | 8 or 16 independent optical channels |
| Measurement Error | ±0.5% (inhibition rate) |
| Limit of Detection (LOD) | 0.3 ppm (for common organophosphates and carbamates) |
| Absorbance Range | 0–3.0 AU |
| Absorbance Accuracy | ±0.01 (0–2.0 AU) |
| Zero Drift | ≤0.1%/3 min |
| Repeatability | ±0.5% (transmittance) |
| Assay Time | 1–9 minutes per sample |
| Display | 4.3″ color TFT LCD (480×272 resolution) |
| Dimensions | 300 × 200 × 130 mm |
| Battery | 6400 mAh rechargeable Li-ion (≥24 h continuous operation) |
| Data Storage | Up to 780,000 test records |
| Interface | USB 2.0 |
| Compliance | GB/T 5009.199–2003, NY/T 448–2001 |
| Brand | HKM (Guangdong Huankai Microbial Technology Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Model | SAJ Series |
| Detection Principle | Enzyme Inhibition + Photometric Colorimetry |
| Detection Channels | 8 or 16 independent optical units |
| Measurement Range | Inhibition Rate 0–100% |
| Absorbance Range | 0–3.0 AU |
| Absorbance Accuracy | ±0.01 (410 nm, 0–2.0 AU), ±0.02 (512 nm & 555 nm, 0–1.0 AU) |
| Repeatability | ±0.5% (transmittance repeatability) |
| Zero Drift | ≤0.1%/3 min |
| Photocurrent Drift | ≤0.1%/3 min |
| Detection Time | 15 s – 30 min per assay |
| Display | 4.3″ color TFT-LCD (480×272 resolution) |
| Data Storage Capacity | Up to 780,000 test records |
| Power Supply | 6400 mAh rechargeable Li-ion battery (≥24 h continuous operation) |
| Dimensions | 300 × 200 × 130 mm |
| Compliance | GB/T 5009.199–2003, GB 5009.33–2010, GB/T 5750.10–2006, NY/T 448–2001 |
| Brand | Höenle |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SFL Floodlight |
| Pricing | Available Upon Request |
| Housing | Extruded aluminum profile with aluminum plates |
| Finish | High-temperature-resistant powder coating |
| Igniter | Integrated, thermally insulated, tool-free replaceable |
| Thermal Design | Compact architecture with low socket temperature |
| Environmental Suitability | Engineered for climate chambers and wind tunnels |
| Lamp Replacement | Tool-free front-access lamp change |
| Beam Angle | 60° symmetric wide-angle distribution (±30°) |
| Optional Lamps | Temperature-controlled HMI/HQI variants |
| Dimensions (W×H×D) | 460 × 440 × 250 mm (standard) / 460 × 440 × 380 mm (with rear cooling extension) |
| Weight | 15 kg (bare unit), 17 kg (without mounting bracket and front glass) |
| Power Supply | Internally integrated EVG EPS20C-HQI / EPS25C-HMI / EPS40C-HMI / EPS80C-HMI electronic ballasts with active power factor correction (PFC) |
| Input | Single-phase 208–240 V, 50/60 Hz |
| Lamp Options | HQI 2000 W, HMI 2500 W/DXS, HMI 4000 W/DXS |
| Mechanical Shutter | Slide-in rail-mounted design, full radiation blockage, continuous-duty rated, auto-dimming to 50% output when closed |
| Shutter Dimensions | 860 × 520 × 60 mm |
| Shutter Weight | 6.0 kg |
| Accessories | Mechanical shutter, universal mounting bracket, front glass H1 (indoor-rated), front glass H2 (outdoor-rated), transmission-adjusting diffuser grids |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Model | Compact UV Curing System |
| Lamp Length | 100–540 mm (customizable) |
| Max Power Density | 236 W/cm |
| Cooling | Air-cooled or air/water hybrid |
| Quartz Front Window | Oil- and dust-resistant |
| Control Interface | PLC-integrated with shutter & intensity modulation |
| Power Adjustment | Continuously variable from 30% to 100% |
| Compliance | Designed for integration into industrial OEM lines |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Model | EPSA 240 |
| Max. Output Power | 24 kW |
| Output Waveform | Square Wave |
| Power Adjustment Range | 11–100% (continuously variable) |
| Connectors | Pluggable, service-oriented interface |
| Design | Compact and lightweight |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Model | EPSA Series (EPSA 80 / EPSA 120 / EPSA 240 / EPSA 340) |
| Input Voltage | 400–480 V AC, 50/60 Hz |
| Power Output Range | 8–32 kW |
| Control | 12–100% stepless dimming |
| Cooling | Integrated forced-air or liquid-cooled variants |
| Compliance | CE, IEC 61000-6-3, IEC 61000-6-4, EN 61204-3 |
| Footprint Reduction | Up to 50% vs. conventional magnetic ballasts |
| Weight | Significantly reduced vs. legacy systems |
| Fault Diagnostics | Real-time monitoring with event logging |
| Restrike Capability | Enhanced hot-restart performance |
| Cable Reduction | Optimized internal bus architecture minimizing external cabling |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Type | Industrial Infrared Emitter Tube |
| Wavelength Options | NIR (3000 K filament), Short-Wave IR (2300 K), Medium-Wave IR (900 K), Fast Medium-Wave IR (1600 K) |
| Max Length | 3000 mm |
| Custom Configurations | Single- or dual-end termination, twin-tube modules |
| Compliance | CE-marked, RoHS-compliant, designed for integration into industrial heating systems |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IR Solar Simulator System |
| Pricing | Upon Request |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Model | jetCURE LED |
| Wavelength Options | 365 nm, 385 nm, 395 nm, 405 nm (±10 nm tolerance) |
| Application | Pre-cure, final cure, ink, coating, adhesive, encapsulant, and sealant curing in industrial printing and building materials manufacturing |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Model | jetCURE UV Series |
| UV Output | up to 240 W/cm |
| Cooling | Air-cooled |
| Spectral Options | 365 / 385 / 395 / 405 nm (±10 nm) |
| Configuration | Modular linear array, shutter-integrated, electronically controlled power supply |
| Compliance | CE, RoHS, ISO 14001 (manufacturer), compatible with GMP/GLP-aligned process validation frameworks |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Model | jetCURE UV/IR/LED Series |
| Max UV Power Output | 240 W/cm |
| UV Wavelength Options | 365, 385, 395, 405 nm (±10 nm) |
| Cooling | Air-cooled IR module |
| Configuration | Modular linear units with shutter system and electronic power control |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Model | LED Cube 100 IC |
| Type | Integrated Benchtop UV LED Curing System |
| Wavelength Options | 365 nm, 385 nm, 405 nm (selectable) |
| LED Power Control Range | 10–100% (continuous, stepless) |
| LED Lifetime | ≥20,000 hours (L70) |
| Cooling | Active air-cooled thermal management |
| Compliance | CE, RoHS, IEC 61000-6-3/-4 |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Model | LED Floodlight |
| Power Options | 3000 W / 4500 W / 6000 W (main array) |
| Cooling | Integrated forced-air cooling system with aluminum heat sinks |
| Control Interface | Dedicated power supply with remote ON/OFF input and programmable boost timer (up to 15 s at full channel output) |
| Optical Flexibility | Five interchangeable lenses with distinct beam angles (e.g., 10°, 25°, 40°, 60°, 90° FWHM) |
| Illuminance Output | ≥100,000 lux at 6–12 m distance (per fixture, calibrated per ISO/CIE photometric standards) |
| Compliance | Designed for ISO 17025-accredited crash test laboratories |
| Mounting | Modular aluminum extrusion chassis for rigid multi-unit alignment |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Configuration | 4-Channel Modular LED Array with Integrated Air Cooling |
| Max. Boost Power | 1500 W per Channel (up to 15 s) |
| Standard Operating Power | 750–3000 W total |
| Beam Angle Options | 5 Interchangeable Optical Lenses |
| Control Interface | TTL-compatible On/Off Input, Programmable Auto-Timer for Boost Mode |
| Compliance | Designed for ISO/IEC 17025-aligned test laboratories |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Product Type | High-Speed Imaging Floodlight System |
| Power Options | 1500 W, 3000 W, 4500 W, 6000 W (per system) |
| Cooling | Integrated aluminum heat sinks + forced-air cooling |
| Control Interface | Dedicated power supply with ON/OFF input, boost mode timer (up to 15 s), dimming capability |
| Optical Flexibility | Five interchangeable lenses with distinct beam angles |
| Compliance | Designed for ISO/IEC 17025-aligned test environments |
| Brand | Hoenle |
|---|---|
| Origin | Germany |
| Model | LED Power Pen 2.0 |
| Wavelength | 365 nm ±10 nm |
| Power Supply | External AC/DC adapter (included, worldwide voltage compatible) |
| Activation | Manual pressure switch on unit |
| Optional Control | Dry-contact PLC input or footswitch interface |
| Safety Features | Integrated thermal cutoff and internal current regulation |
| Compliance | CE-marked, RoHS-compliant, designed for industrial UV curing environments |