BrandCole-Parmer
OriginUSA
Model05611-21
Flow Range0.26–8 GPM
Accuracy±0.5% of reading
Viscosity Range1–1000 cP
Operating Temperature−5 to 55 °C (23 to 131 °F)
Max Pressure1500 psi
Wetted MaterialsAcetal, aluminum, steel, nitrile
Power SupplyTwo AAA batteries
Battery Life2000 hours
Display6-digit LCD
Connection1/2" NPT(F)
Unitsgal, L, qt, pt
OutputLocal display only (no pulse or remote output)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCole-Parmer
OriginUSA
Model05613-65
Power Supply230 VAC
Flow Measurement PrincipleTransit-time ultrasonic
Pipe ID Range25–762 mm (1–30 in)
Velocity Range0.1 ft/s to 30 ft/s (0.03–9.14 m/s)
Flow Unitsgal/min, ft³/s, gal/day, Mgal/day, L/s
Totalizer Resolution7-digit, in gal or L
Display3.5-digit LCD, 12.7 mm digit height
Accuracy±2.0 least significant digit
Repeatability±0.2% of full scale
Operating Temperature−5 to 70 °C
Output4–20 mA analog, user-adjustable digital filter, response time 0–99 s
Enclosure Dimensions105 mm W × 184 mm H × 51 mm D
Battery Life4 h (rechargeable NiMH), included charger/AC adapter
Standard Accessories1 m cable, flow sensor coupling kit, nylon carrying case with shoulder strap
Fluid CompatibilityLiquids containing suspended solids or entrained gas (≥100 µm particles, ≤100 lb/min solids loading)
NIST TraceabilityNot certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCole-Parmer
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model32648-00
PricingUpon Request
Sensor PrincipleThermal Mass Flow Measurement (Constant Temperature Anemometry)
Accuracy±1.0% FS (≤15 SLPM), ±1.5% FS (>15 SLPM)
Repeatability±0.5% FS
Response Time2 s
Operating Temperature0–50 °C
Max System Pressure500 psi (3.4 MPa)
Max Particle Size5 µm
Leak Rate≤1 × 10⁻⁷ sccs He
Output Signals0–5 VDC and/or 4–20 mA
DisplayRemovable 3.5-digit LCD, 90° rotatable
Housing OptionsAnodized Aluminum or 316 Stainless Steel
Wetted MaterialsAnodized Al / Brass / Viton® (Al housing)
Interface Sizes1/4" compression (≤50 SLPM), 3/8" (100–200 SLPM), 1/2" (500 SLPM), 3/4" female NPT (1000 SLPM)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCole-Parmer
OriginUSA
Model32986-00
Liquid TypeSuspensions with particles ≥100 µm or entrained gas bubbles
Flow Range0.30–16 ft/s (0.1–9 m/s)
Accuracy±2% of full scale
Repeatability±1% of full scale
Operating Temperature–20 to 60 °C (–28 to 140 °F)
Display4-digit LCD, switchable between ft/s and m/s
Power Supply4 × AA alkaline batteries
Dimensions102 mm W × 197 mm H × 38 mm D
CE CompliantYes
NIST TraceabilityNot certified
Sensor MountingClamp-on, non-intrusive
Pipe Diameter Range25–1524 mm (1–60 in)
Transducer Cable Length1.83 m (6 ft)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCole-Parmer
Model05629-22 (Battery-Powered) / 05629-40 (AC/DC-Powered)
Accuracy±0.5% of reading
DisplayUpper 4-digit LCD (flow rate), Lower 8-digit LCD (totalizer)
Power05629-22 — dual internal lithium batteries (4-year nominal life)
Dimensions05629-22 — 3.875" W × 3.875" H × 3.875" D
Operating Temperature–10 to 55 °C (14 to 131 °F)
Relay Output2 SPDT, 125 VAC / 30 VDC, 5 A max
Analog Output4–20 mA (non-isolated)
Pulse OutputOptically isolated, sink current ≤5 mA
Display Update Rate200 ms
Hysteresis2% of setpoint
Sensor CompatibilityRoto-X and Metalex flow sensors only (Roto-X low-flow sensors excluded)
Environmental RatingNEMA 4X-rated enclosure (IP65 equivalent)