Empowering Scientific Discovery

Jingyi Xingye Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
ModelCOND600
OriginUSA
Instrument TypePortable Conductivity/TDS/Temp Meter
IP RatingIP67
GLP ComplianceYes
Measurement PrinciplesTwo-electrode AC conductivity, temperature-compensated TDS calculation (linear α coefficient), NIST-traceable calibration
Key RangesConductivity 0–200.0 mS/cm (5-range auto-ranging)
Resolution0.01 µS/cm (low range) to 0.1 mS/cm (high range)
Accuracy±1% of full scale + 1 LSD (conductivity & TDS)
CalibrationUp to 4-point automatic or 5-point manual using standard KCl solutions
Temperature CompensationLinear, user-selectable α (0.00 to 10.00 %/°C), default 2.00 %/°C
Electrode Constant Range0.010–10.000 cm⁻¹
Data Storage500 measurement sets with timestamp, temperature, and electrode ID
ConnectivityRS-232C serial port, IrDA infrared interface
Power4×AA alkaline batteries (≥200 h operation) or optional 9 V DC adapter (500 mA)
Dimensions (unit)18.3 × 9.5 × 5.7 cm
Weight (unit)460 g
Operating Environment0–50 °C, ≤95% RH non-condensing
Storage Environment−25–70 °C
DisplayBacklit LCD (5.4 × 7.1 cm active area), multi-parameter real-time view
Auto-offConfigurable 2–30 min idle timeout
Auto-holdYes
CertificationsCE, RoHS, FCC Class B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelSalt6+
Measurement PrincipleConductivity-based salinity determination with automatic temperature compensation (ATC)
Salinity Range1.0–50.0 ppt / 0.1–5.00%
Salinity Resolution0.1 ppt / 0.01%
Salinity Accuracy±1% of full scale
Temperature Range−10.0 to 110.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
Temperature CompensationATC/MTC (0–50 °C)
Adjustable Temperature Coefficient0.0–3.0 %/°C
Reference Temperatures20.0 °C or 25.0 °C (selectable)
Cell Constant1.0 cm⁻¹
Data Hold FunctionYes
Auto Power-OffAfter 20 min of inactivity
Power Supply4 × 1.5 V AAA batteries
Dimensions (Instrument)14 × 17 × 3.5 cm
Weight (Instrument)200 g
Dimensions (Packaging)24 × 17 × 8 cm
Weight (Packaging)550 g
ComplianceDesigned for GLP-compliant field and lab use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
ModelPH700
OriginUSA
TypeBenchtop Electrochemical pH Meter
pH Range−2.00 to 16.00
pH Resolution & Accuracy0.01, ±0.01 pH
mV Range±2000 mV
mV Resolution & Accuracy0.1 mV (±199.9 mV), 1 mV (±200 mV+)
Temperature Range0.0 to 100.0 °C
Temp Resolution & Accuracy0.1 °C, ±0.5 °C
Calibration PointsUp to 5-point
Buffer StandardsUSA (pH 4.01, 7.00, 10.01) and NIST (pH 4.01, 6.86, 9.18)
Temperature CompensationAutomatic or Manual (0–100 °C)
Data Storage100 measurements
Output InterfaceRS-232 or USB (with optional cable)
Power Supply9 V DC adapter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
ModelPHTestr 30
OriginUSA
TypeWaterproof Portable pH/Temp Pen Meter
Measurement RangepH –1.00 to 15.00, Temperature 0 to 50 °C
Resolution0.01 pH / 0.1 °C
Accuracy±0.01 pH / ±0.5 °C
CalibrationAuto 3-point with USA (4.01, 7.00, 10.01) or NIST (4.01, 6.86, 9.18) buffers
Temperature CompensationAutomatic (ATC)
Electrode DesignDouble-junction Ag/AgCl reference system with high-capacity gel electrolyte
Auto-offAfter 8.5 minutes of inactivity
DisplayDual-line LCD (2.1 × 2.7 cm)
Power4 × 1.5 V button cells (LR44)
Battery Life>500 hours
Operating Temperature0–50 °C
Dimensions (Instrument)16.5 × 3.8 cm
Weight (Instrument)90 g
Packaging Dimensions18.5 × 6.5 × 5 cm
Weight (Packaged)200 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetrohm
OriginSwitzerland
Model905 / 907
Measurement Range±1200 mV, ±120 µA
Meter Accuracy0.15% (±30 µL at 20 mL)
Resolution0.001 pH, 0.1 mV, 0.1 °C
Titration Accuracy0.15% (±30 µL at 20 mL)
ComplianceFDA 21 CFR Part 11, GLP/GMP-ready, ASTM E202–22 applicable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelECtestr 11+
Conductivity Range0–200.0 µS/cm, 0–2000 µS/cm, 0–20.00 mS/cm
Resolution0.1 µS/cm, 1 µS/cm, 0.01 mS/cm
Accuracy±1% of full scale
Calibration Points3-point (auto/manual)
Temperature Range0–50.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
TDS Conversion FactorAdjustable (0.40–1.00)
Sensor MaterialSS316 stainless steel with Valox protective housing
Ingress ProtectionIP67
PowerReplaceable batteries
Battery Status RetentionCalibration settings retained after battery replacement
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelORPTestr 10
Electrode TypeDouble-Junction
InterfaceBNC (ORPTestr 10 BNC variant)
Measurement Range−999 to +1000 mV
Resolution1 mV
Accuracy±2 mV
CalibrationSingle-point manual
Temperature CompensationNone
Operating Temperature0–50 °C
DisplayDual-line LCD (2.1 × 2.7 cm)
Power4 × 1.5 V button cells
Battery Life>500 hours
Dimensions (Instrument Only)16.5 × 3.8 cm
Weight (Instrument Only)90 g
Packaging Dimensions18.5 × 6.5 × 5 cm
Package Weight200 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelT5 / T7 / T9
Measurement Range±2000 mV / −26.0 to +40.0 pH
Meter Accuracy0.01%
Meter Resolution0.1 mV / 0.001 pH
Titration Precision0.2 mV / 0.003 pH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelCON 6000
Conductivity Range0.000–500.0 mS/cm
Resistivity Range3 Ω·cm – 100 MΩ·cm
TDS Range0.0–500.0 ppt
Accuracy±0.5% of full scale + 1 digit
Repeatability±0.01% of full scale
Temperature Range−5.0 to 105.0 °C
Temp. Accuracy±0.2 °C
Temp. Repeatability±0.1 °C
CalibrationAuto or manual up to 4-point per range
Cell Constants0.1, 1.0, 10.0 cm⁻¹
Display640 × 480 pixel color TFT touchscreen
Data StorageUp to 10,000 readings with timestamp and user ID
ConnectivityUSB, IrDA, RS-232C, Ethernet (RJ45)
Power9 VDC, 3.3 A, center-negative
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetrohm
OriginSwitzerland
Model848
Titration PrinciplePotentiometric Endpoint Detection
Burette Resolution1/10,000
Input Signal ResolutionHigh-resolution analog-to-digital conversion
Control InterfaceKeyboard & USB Mouse
DisplayIntegrated high-contrast LCD with real-time titration curve plotting
Stirring OptionsCompatible with 801 Magnetic Stirrer or 802 Spiral Stirrer
ComplianceGLP/GMP-compliant data handling, ASTM E202–22, ISO 8655-3, USP <541>, FDA 21 CFR Part 11 ready (with optional software modules)
ConnectivityRS232, USB Host (for printer, keyboard, mouse, barcode scanner, USB storage), Remote I/O for autosamplers (e.g., 869 Compact Sample Processor)
Software Supporttiamo™ PC software for method development, data acquisition, audit trail, electronic signatures, and LIMS integration
Measurement ModesSET (set endpoint), MET (equivalence point), DET (dynamic titration), pH/mV/T measurement, 5-point pH calibration
Optional ModulesPhotometric titration (523 nm / 610 nm), Polarographic titration (Ipol/Upol)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginSingapore
ModelpH6+
Instrument TypePortable
Measurement ParameterspH, ORP, Temperature (°C)
pH Range0.00–14.00
pH Resolution0.01 pH
pH Accuracy±0.01 pH
Temperature Range0.0–100.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
ORP Range±1000 mV
ORP Resolution0.1 mV (up to 199.9 mV), 1 mV (above)
ORP Accuracy±2 mV ±1 LSD
Calibration Points3-point (pH)
Buffer StandardsUSA, NIST, PWB
ATC/MTC Compensation0–100 °C
Auto-OffAfter 20 min inactivity
Power Supply4 × 1.5 V AAA alkaline batteries
Battery Life>200 hours
DisplayLCD (4.5 × 2.3 cm)
Dimensions (unit)14 × 17 × 3.5 cm
Weight (unit)200 g
Packaging Dimensions36 × 28 × 8 cm
Packaging Weight1500 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelCON700
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelPC700
pH Range–2.00 to 16.00 pH
pH Resolution0.01 pH
pH Accuracy±0.01 pH + 1 LSD
pH CalibrationUp to 5-point (pH 1.68, 4.01, 7.00, 10.01, 12.45)
Temperature Range–10.0 to 110.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
Conductivity Range0–200.0 mS/cm
Conductivity Resolution0.1 / 0.01 mS/cm
Conductivity Accuracy±1% of full scale
Conductivity CalibrationUp to 5-point per range
TDS Range0–100 ppt (TDS factor 0.5)
TDS Resolution0.1 / 0.01 ppt
TDS Accuracy±1% of full scale + 1 digit
TDS CalibrationUp to 5-point per range
mV Range±2000 mV
mV Resolution0.1 mV (±199.9 mV), 1 mV (>±200 mV)
mV Accuracy±0.2 mV (±199.9 mV), ±2 mV (>±200 mV)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelS210 / S220 / S230
Instrument TypeBenchtop
Parameter TypesMulti-parameter (pH, mV, rel. mV, °C)
Measurement Range–2.000 to 20.000 pH
Resolution0.001 / 0.01 / 0.1 pH
Accuracy±0.002 pH
Calibration SolutionsChina-specific buffer sets (e.g., pH 4.01, 6.86, 9.18)
IP RatingIP54
DisplayHigh-contrast color TFT touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginShanghai, China
Manufacturer StatusAuthorized Distributor
Product OriginDomestic (China)
ModelsET18 / ET28 / ET38 / ET58 / Easy Na
Instrument TypeGeneral-purpose Potentiometric Titrator
Application ScopeUniversal
Measurement RangespH: 1–14
mV0–2000 mV
Temperature0–100 °C
Meter Accuracy±0.2% of full scale
Meter ResolutionpH: 0.01 pH
mV0.1 mV
Temperature0.1 °C
Titration Stability(±0.3 mV ±1 digit) over 3 h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelG10S / G20S
Instrument TypeGeneral-purpose Automatic Potentiometric Titrator
Measurement Range±2000 mV / pH –26.0 to 40.0
Meter Accuracy0.01%
Meter Resolution0.1 mV / 0.001 pH
Titration Precision0.2 mV / 0.003 pH
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0