- All
- Favorite
- Popular
- Most rated
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | COND600 |
| Origin | USA |
| Instrument Type | Portable Conductivity/TDS/Temp Meter |
| IP Rating | IP67 |
| GLP Compliance | Yes |
| Measurement Principles | Two-electrode AC conductivity, temperature-compensated TDS calculation (linear α coefficient), NIST-traceable calibration |
| Key Ranges | Conductivity 0–200.0 mS/cm (5-range auto-ranging) |
| Resolution | 0.01 µS/cm (low range) to 0.1 mS/cm (high range) |
| Accuracy | ±1% of full scale + 1 LSD (conductivity & TDS) |
| Calibration | Up to 4-point automatic or 5-point manual using standard KCl solutions |
| Temperature Compensation | Linear, user-selectable α (0.00 to 10.00 %/°C), default 2.00 %/°C |
| Electrode Constant Range | 0.010–10.000 cm⁻¹ |
| Data Storage | 500 measurement sets with timestamp, temperature, and electrode ID |
| Connectivity | RS-232C serial port, IrDA infrared interface |
| Power | 4×AA alkaline batteries (≥200 h operation) or optional 9 V DC adapter (500 mA) |
| Dimensions (unit) | 18.3 × 9.5 × 5.7 cm |
| Weight (unit) | 460 g |
| Operating Environment | 0–50 °C, ≤95% RH non-condensing |
| Storage Environment | −25–70 °C |
| Display | Backlit LCD (5.4 × 7.1 cm active area), multi-parameter real-time view |
| Auto-off | Configurable 2–30 min idle timeout |
| Auto-hold | Yes |
| Certifications | CE, RoHS, FCC Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Salt6+ |
| Measurement Principle | Conductivity-based salinity determination with automatic temperature compensation (ATC) |
| Salinity Range | 1.0–50.0 ppt / 0.1–5.00% |
| Salinity Resolution | 0.1 ppt / 0.01% |
| Salinity Accuracy | ±1% of full scale |
| Temperature Range | −10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | ATC/MTC (0–50 °C) |
| Adjustable Temperature Coefficient | 0.0–3.0 %/°C |
| Reference Temperatures | 20.0 °C or 25.0 °C (selectable) |
| Cell Constant | 1.0 cm⁻¹ |
| Data Hold Function | Yes |
| Auto Power-Off | After 20 min of inactivity |
| Power Supply | 4 × 1.5 V AAA batteries |
| Dimensions (Instrument) | 14 × 17 × 3.5 cm |
| Weight (Instrument) | 200 g |
| Dimensions (Packaging) | 24 × 17 × 8 cm |
| Weight (Packaging) | 550 g |
| Compliance | Designed for GLP-compliant field and lab use |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | PH700 |
| Origin | USA |
| Type | Benchtop Electrochemical pH Meter |
| pH Range | −2.00 to 16.00 |
| pH Resolution & Accuracy | 0.01, ±0.01 pH |
| mV Range | ±2000 mV |
| mV Resolution & Accuracy | 0.1 mV (±199.9 mV), 1 mV (±200 mV+) |
| Temperature Range | 0.0 to 100.0 °C |
| Temp Resolution & Accuracy | 0.1 °C, ±0.5 °C |
| Calibration Points | Up to 5-point |
| Buffer Standards | USA (pH 4.01, 7.00, 10.01) and NIST (pH 4.01, 6.86, 9.18) |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Data Storage | 100 measurements |
| Output Interface | RS-232 or USB (with optional cable) |
| Power Supply | 9 V DC adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | PHTestr 30 |
| Origin | USA |
| Type | Waterproof Portable pH/Temp Pen Meter |
| Measurement Range | pH –1.00 to 15.00, Temperature 0 to 50 °C |
| Resolution | 0.01 pH / 0.1 °C |
| Accuracy | ±0.01 pH / ±0.5 °C |
| Calibration | Auto 3-point with USA (4.01, 7.00, 10.01) or NIST (4.01, 6.86, 9.18) buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Design | Double-junction Ag/AgCl reference system with high-capacity gel electrolyte |
| Auto-off | After 8.5 minutes of inactivity |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Power | 4 × 1.5 V button cells (LR44) |
| Battery Life | >500 hours |
| Operating Temperature | 0–50 °C |
| Dimensions (Instrument) | 16.5 × 3.8 cm |
| Weight (Instrument) | 90 g |
| Packaging Dimensions | 18.5 × 6.5 × 5 cm |
| Weight (Packaged) | 200 g |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 905 / 907 |
| Measurement Range | ±1200 mV, ±120 µA |
| Meter Accuracy | 0.15% (±30 µL at 20 mL) |
| Resolution | 0.001 pH, 0.1 mV, 0.1 °C |
| Titration Accuracy | 0.15% (±30 µL at 20 mL) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready, ASTM E202–22 applicable |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ECtestr 11+ |
| Conductivity Range | 0–200.0 µS/cm, 0–2000 µS/cm, 0–20.00 mS/cm |
| Resolution | 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm |
| Accuracy | ±1% of full scale |
| Calibration Points | 3-point (auto/manual) |
| Temperature Range | 0–50.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| TDS Conversion Factor | Adjustable (0.40–1.00) |
| Sensor Material | SS316 stainless steel with Valox protective housing |
| Ingress Protection | IP67 |
| Power | Replaceable batteries |
| Battery Status Retention | Calibration settings retained after battery replacement |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ORPTestr 10 |
| Electrode Type | Double-Junction |
| Interface | BNC (ORPTestr 10 BNC variant) |
| Measurement Range | −999 to +1000 mV |
| Resolution | 1 mV |
| Accuracy | ±2 mV |
| Calibration | Single-point manual |
| Temperature Compensation | None |
| Operating Temperature | 0–50 °C |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Power | 4 × 1.5 V button cells |
| Battery Life | >500 hours |
| Dimensions (Instrument Only) | 16.5 × 3.8 cm |
| Weight (Instrument Only) | 90 g |
| Packaging Dimensions | 18.5 × 6.5 × 5 cm |
| Package Weight | 200 g |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T5 / T7 / T9 |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | CON 6000 |
| Conductivity Range | 0.000–500.0 mS/cm |
| Resistivity Range | 3 Ω·cm – 100 MΩ·cm |
| TDS Range | 0.0–500.0 ppt |
| Accuracy | ±0.5% of full scale + 1 digit |
| Repeatability | ±0.01% of full scale |
| Temperature Range | −5.0 to 105.0 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Repeatability | ±0.1 °C |
| Calibration | Auto or manual up to 4-point per range |
| Cell Constants | 0.1, 1.0, 10.0 cm⁻¹ |
| Display | 640 × 480 pixel color TFT touchscreen |
| Data Storage | Up to 10,000 readings with timestamp and user ID |
| Connectivity | USB, IrDA, RS-232C, Ethernet (RJ45) |
| Power | 9 VDC, 3.3 A, center-negative |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 848 |
| Titration Principle | Potentiometric Endpoint Detection |
| Burette Resolution | 1/10,000 |
| Input Signal Resolution | High-resolution analog-to-digital conversion |
| Control Interface | Keyboard & USB Mouse |
| Display | Integrated high-contrast LCD with real-time titration curve plotting |
| Stirring Options | Compatible with 801 Magnetic Stirrer or 802 Spiral Stirrer |
| Compliance | GLP/GMP-compliant data handling, ASTM E202–22, ISO 8655-3, USP <541>, FDA 21 CFR Part 11 ready (with optional software modules) |
| Connectivity | RS232, USB Host (for printer, keyboard, mouse, barcode scanner, USB storage), Remote I/O for autosamplers (e.g., 869 Compact Sample Processor) |
| Software Support | tiamo™ PC software for method development, data acquisition, audit trail, electronic signatures, and LIMS integration |
| Measurement Modes | SET (set endpoint), MET (equivalence point), DET (dynamic titration), pH/mV/T measurement, 5-point pH calibration |
| Optional Modules | Photometric titration (523 nm / 610 nm), Polarographic titration (Ipol/Upol) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Model | pH6+ |
| Instrument Type | Portable |
| Measurement Parameters | pH, ORP, Temperature (°C) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| ORP Range | ±1000 mV |
| ORP Resolution | 0.1 mV (up to 199.9 mV), 1 mV (above) |
| ORP Accuracy | ±2 mV ±1 LSD |
| Calibration Points | 3-point (pH) |
| Buffer Standards | USA, NIST, PWB |
| ATC/MTC Compensation | 0–100 °C |
| Auto-Off | After 20 min inactivity |
| Power Supply | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Display | LCD (4.5 × 2.3 cm) |
| Dimensions (unit) | 14 × 17 × 3.5 cm |
| Weight (unit) | 200 g |
| Packaging Dimensions | 36 × 28 × 8 cm |
| Packaging Weight | 1500 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CON700 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | PC700 |
| pH Range | –2.00 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH + 1 LSD |
| pH Calibration | Up to 5-point (pH 1.68, 4.01, 7.00, 10.01, 12.45) |
| Temperature Range | –10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Conductivity Range | 0–200.0 mS/cm |
| Conductivity Resolution | 0.1 / 0.01 mS/cm |
| Conductivity Accuracy | ±1% of full scale |
| Conductivity Calibration | Up to 5-point per range |
| TDS Range | 0–100 ppt (TDS factor 0.5) |
| TDS Resolution | 0.1 / 0.01 ppt |
| TDS Accuracy | ±1% of full scale + 1 digit |
| TDS Calibration | Up to 5-point per range |
| mV Range | ±2000 mV |
| mV Resolution | 0.1 mV (±199.9 mV), 1 mV (>±200 mV) |
| mV Accuracy | ±0.2 mV (±199.9 mV), ±2 mV (>±200 mV) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S210 / S220 / S230 |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, rel. mV, °C) |
| Measurement Range | –2.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH |
| Accuracy | ±0.002 pH |
| Calibration Solutions | China-specific buffer sets (e.g., pH 4.01, 6.86, 9.18) |
| IP Rating | IP54 |
| Display | High-contrast color TFT touchscreen |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | ET18 / ET28 / ET38 / ET58 / Easy Na |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: 1–14 |
| mV | 0–2000 mV |
| Temperature | 0–100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Stability | (±0.3 mV ±1 digit) over 3 h |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | G10S / G20S |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Measurement Range | ±2000 mV / pH –26.0 to 40.0 |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
Show next