- All
- Favorite
- Popular
- Most rated
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | COND600 |
| Origin | USA |
| Instrument Type | Portable Conductivity/TDS/Temp Meter |
| IP Rating | IP67 |
| GLP Compliance | Yes |
| Measurement Principles | Two-electrode AC conductivity, temperature-compensated TDS calculation (linear α coefficient), NIST-traceable calibration |
| Key Ranges | Conductivity 0–200.0 mS/cm (5-range auto-ranging) |
| Resolution | 0.01 µS/cm (low range) to 0.1 mS/cm (high range) |
| Accuracy | ±1% of full scale + 1 LSD (conductivity & TDS) |
| Calibration | Up to 4-point automatic or 5-point manual using standard KCl solutions |
| Temperature Compensation | Linear, user-selectable α (0.00 to 10.00 %/°C), default 2.00 %/°C |
| Electrode Constant Range | 0.010–10.000 cm⁻¹ |
| Data Storage | 500 measurement sets with timestamp, temperature, and electrode ID |
| Connectivity | RS-232C serial port, IrDA infrared interface |
| Power | 4×AA alkaline batteries (≥200 h operation) or optional 9 V DC adapter (500 mA) |
| Dimensions (unit) | 18.3 × 9.5 × 5.7 cm |
| Weight (unit) | 460 g |
| Operating Environment | 0–50 °C, ≤95% RH non-condensing |
| Storage Environment | −25–70 °C |
| Display | Backlit LCD (5.4 × 7.1 cm active area), multi-parameter real-time view |
| Auto-off | Configurable 2–30 min idle timeout |
| Auto-hold | Yes |
| Certifications | CE, RoHS, FCC Class B |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InMotion KF Flex / Pro |
| Heating Method | Infrared |
| Sample Capacity | 24 positions on 25 cm footprint |
| Gas Flow Control | Digital mass flow meter (air or lab-line gas) |
| Temperature Program | Temperature ramping and isothermal scanning |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation (when paired with compatible titrators) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric/Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 ppm to 100% (V20S: volumetric |
| V30S | coulometric, down to 1 ppm) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Control Precision | 20,000 steps |
| Compliance | Designed for GLP/GMP environments with audit trail capability per FDA 21 CFR Part 11 requirements |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010 Pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Oven Ramp Rate | –250 to +250 °C/min (programmable) |
| Oven Cool-down Time | ≤3.4 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (7-segment programming) |
| Carrier Gas Pressure Range & Control | 0–1035 kPa (7-segment programming) |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1250 mL/min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Salt6+ |
| Measurement Principle | Conductivity-based salinity determination with automatic temperature compensation (ATC) |
| Salinity Range | 1.0–50.0 ppt / 0.1–5.00% |
| Salinity Resolution | 0.1 ppt / 0.01% |
| Salinity Accuracy | ±1% of full scale |
| Temperature Range | −10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | ATC/MTC (0–50 °C) |
| Adjustable Temperature Coefficient | 0.0–3.0 %/°C |
| Reference Temperatures | 20.0 °C or 25.0 °C (selectable) |
| Cell Constant | 1.0 cm⁻¹ |
| Data Hold Function | Yes |
| Auto Power-Off | After 20 min of inactivity |
| Power Supply | 4 × 1.5 V AAA batteries |
| Dimensions (Instrument) | 14 × 17 × 3.5 cm |
| Weight (Instrument) | 200 g |
| Dimensions (Packaging) | 24 × 17 × 8 cm |
| Weight (Packaging) | 550 g |
| Compliance | Designed for GLP-compliant field and lab use |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA100 Series Moisture Analyzer |
| Measurement Range | 0.05–100% moisture content |
| Readability | 0.001% |
| Weighing Precision | 0.1 mg |
| Heating Options | Ceramic IR heater, halogen lamp, quartz CQR heater |
| Heating Modes | Standard, Rapid, Gentle, Step (3 stages × 0.1–999 min) |
| Analysis Modes | Fully automatic, semi-automatic, timed (3 × 0.1–999 min), timed + auto/semi-auto (2 × 0.1–999 min + auto) |
| Built-in Calibration Weight | Yes |
| Reproducibility Test Function (reproTEST) | Yes |
| Programmable Methods | 30 |
| Data Storage Capacity | Up to 9,999 measurement records |
| Compliance | EC Type Approval Certificate, DIN/ISO-compliant automatic calibration and validation routines |
| Interface | RS-232, optional barcode scanner support |
| FDA/HACCP Compatibility | Requires YDS03MA adapter kit |
| GLP/GMP-Ready Print Output | Yes, user-configurable |
| Password Protection | Yes |
| Dust-Protected Keypad | Yes |
| Operating Temperature Range | Ambient to 180 °C (adjustable in 1 °C increments) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | PH700 |
| Origin | USA |
| Type | Benchtop Electrochemical pH Meter |
| pH Range | −2.00 to 16.00 |
| pH Resolution & Accuracy | 0.01, ±0.01 pH |
| mV Range | ±2000 mV |
| mV Resolution & Accuracy | 0.1 mV (±199.9 mV), 1 mV (±200 mV+) |
| Temperature Range | 0.0 to 100.0 °C |
| Temp Resolution & Accuracy | 0.1 °C, ±0.5 °C |
| Calibration Points | Up to 5-point |
| Buffer Standards | USA (pH 4.01, 7.00, 10.01) and NIST (pH 4.01, 6.86, 9.18) |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Data Storage | 100 measurements |
| Output Interface | RS-232 or USB (with optional cable) |
| Power Supply | 9 V DC adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | PHTestr 30 |
| Origin | USA |
| Type | Waterproof Portable pH/Temp Pen Meter |
| Measurement Range | pH –1.00 to 15.00, Temperature 0 to 50 °C |
| Resolution | 0.01 pH / 0.1 °C |
| Accuracy | ±0.01 pH / ±0.5 °C |
| Calibration | Auto 3-point with USA (4.01, 7.00, 10.01) or NIST (4.01, 6.86, 9.18) buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Design | Double-junction Ag/AgCl reference system with high-capacity gel electrolyte |
| Auto-off | After 8.5 minutes of inactivity |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Power | 4 × 1.5 V button cells (LR44) |
| Battery Life | >500 hours |
| Operating Temperature | 0–50 °C |
| Dimensions (Instrument) | 16.5 × 3.8 cm |
| Weight (Instrument) | 90 g |
| Packaging Dimensions | 18.5 × 6.5 × 5 cm |
| Weight (Packaged) | 200 g |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 905 / 907 |
| Measurement Range | ±1200 mV, ±120 µA |
| Meter Accuracy | 0.15% (±30 µL at 20 mL) |
| Resolution | 0.001 pH, 0.1 mV, 0.1 °C |
| Titration Accuracy | 0.15% (±30 µL at 20 mL) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready, ASTM E202–22 applicable |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA150 |
| Maximum Capacity | 150 g |
| Readability | 0.01 g |
| Sensor Resolution | 1 mg |
| Repeatability | ±0.2% (initial sample ≥1 g), ±0.05% (initial sample ≥5 g) |
| Heating Range | 40–220 °C (1 °C increments) |
| Heating Sources | Ceramic IR or Quartz IR heater |
| Endpoint Modes | Automatic, Semi-Automatic (mass loss rate: 1–50 mg/5–300 s or 0.1–5.0 %/5–300 s), Timed |
| Programmable Methods | 20 stored methods |
| Display Units | % moisture, % dry weight, % ratio, evaporation mass (mg), residue (g/kg or g/L), % ash |
| Heating Modes | Standard or Gentle |
| Data Interface | RS232 |
| GLP-Compliant Reporting | Yes (with optional printer YDP03-0CE) |
| Dimensions (W×L×H) | 213 × 320 × 180.5 mm |
| Weight | 5.5 kg |
| Compliance | FDA/HACCP-compliant configuration (aluminum shielding panels replace glass), 21 CFR Part 11-ready with software YMW02MA and audit trail enabled |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2014C |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Control Range | 75–120 °C/min (ramp rate) |
| Temperature Ramp | 100–450 °C in 4.5 min |
| Cooling Rate | 100–0 °C in 4.5 min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 150–700 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 100–500 kPa |
| Injector Total Flow Setting Range | 200–1200 mL/min |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 870 KF Titrino Plus (Volumetric) |
| Measurement Principle | Volumetric Karl Fischer Titration |
| Titration Resolution | 1/10,000 (0.0001 mL) |
| Display | Integrated LCD with Real-Time Titration Curve |
| Input Interface | USB Keyboard & Optical Mouse |
| Dosing Unit | Smart Exchange Unit with Embedded EEPROM Chip |
| Titration Stand | 803 KF Dedicated Titration Stand (Integrated Membrane Pump) |
| Stirring | 801 Magnetic Stirrer (Optional) |
| Connectivity | 1 × USB Port, 1 × MSB Port (Metrohm Serial Bus), RS-232 via USB Adapter (Optional) |
| Compliance | Full GLP/GMP Support, Audit Trail, User Management, Electronic Signatures (21 CFR Part 11 Ready), ASTM E203, ISO 760, USP <921>, EP 2.5.12 |
| Safety Features | Liquid Overflow Prevention, Reagent Transfer Safeguard, Waste Bottle Anti-Siphon Valve, Ethanol-Compatible Solvent System |
| Operating Language | English Only |
| Sample Forms | Solids, Liquids, Gases |
| Moisture Range | 10 ppm to 100 wt% |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ECtestr 11+ |
| Conductivity Range | 0–200.0 µS/cm, 0–2000 µS/cm, 0–20.00 mS/cm |
| Resolution | 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm |
| Accuracy | ±1% of full scale |
| Calibration Points | 3-point (auto/manual) |
| Temperature Range | 0–50.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| TDS Conversion Factor | Adjustable (0.40–1.00) |
| Sensor Material | SS316 stainless steel with Valox protective housing |
| Ingress Protection | IP67 |
| Power | Replaceable batteries |
| Battery Status Retention | Calibration settings retained after battery replacement |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | LCMS-8060NX |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | Dedicated Use |
| Mass Range | 2–2000 m/z |
| Sensitivity | S/N ≥ 2000:1 (100 fg clenbuterol on-column) |
| Resolution | 0.4–0.7 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-TQ8040 NX |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Mode | Conventional Gas Chromatography-Mass Spectrometry (GC-MS/MS) |
| Mass Range | 2–1090 u |
| Resolution | 1000–2000 (FWHM, at m/z 502) |
| Sensitivity | >18,000:1 (S/N, for 1 pg OFN in Scan mode) |
| Scan Speed | Up to 20,000 u/s |
| Ion Source | High-Efficiency EI/CI Dual-Mode Ion Source |
| Collision Cell | Optimized RF-only Quadrupole Collision Cell |
| Temperature Ramp Rate | Programmable up to 120 °C/min (oven-dependent) |
| Pressure Control Accuracy | ±0.01 psi (electronic pneumatic control) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ORPTestr 10 |
| Electrode Type | Double-Junction |
| Interface | BNC (ORPTestr 10 BNC variant) |
| Measurement Range | −999 to +1000 mV |
| Resolution | 1 mV |
| Accuracy | ±2 mV |
| Calibration | Single-point manual |
| Temperature Compensation | None |
| Operating Temperature | 0–50 °C |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Power | 4 × 1.5 V button cells |
| Battery Life | >500 hours |
| Dimensions (Instrument Only) | 16.5 × 3.8 cm |
| Weight (Instrument Only) | 90 g |
| Packaging Dimensions | 18.5 × 6.5 × 5 cm |
| Package Weight | 200 g |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T5 / T7 / T9 |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HC103 |
| Heating Source | Halogen Lamp |
| Compliance | Designed for GLP/GMP environments |
| Software Capability | Built-in method wizard, touch-screen interface, SmartCal performance verification |
| Sample Pan | Stainless steel, flat surface for rapid cleaning |
| Dimensions | Compact footprint (< 200 mm × 300 mm), robust metal housing |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Model | Sepacore |
| Pressure Range | Up to 50 bar (725 psi) |
| Flow Rate | 2.5–250 mL/min |
| Column ID Range | 15–100 mm |
| Max Sample Load | 100 g (glass columns) |
| Detector Wavelength | 190–745 nm |
| Gradient Capability | Binary to Quaternary, 0–100% B, linearity ±2% |
| Software | SepacoreControl (PC-based, optional 21 CFR Part 11 compliance) |
| Pump Type | Tri-piston, pulse-free, solvent-compatible with acids/bases/organics |
| Column Options | Glass (coated), polypropylene flash columns, cartridge-based packing systems |
| Fraction Collection Modes | Time-, volume-, or UV peak-triggered |
| Safety Features | Grounded metal fraction collector arm, transparent pressure-rated glass columns, integrated pressure sensors and level monitoring |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | CON 6000 |
| Conductivity Range | 0.000–500.0 mS/cm |
| Resistivity Range | 3 Ω·cm – 100 MΩ·cm |
| TDS Range | 0.0–500.0 ppt |
| Accuracy | ±0.5% of full scale + 1 digit |
| Repeatability | ±0.01% of full scale |
| Temperature Range | −5.0 to 105.0 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Repeatability | ±0.1 °C |
| Calibration | Auto or manual up to 4-point per range |
| Cell Constants | 0.1, 1.0, 10.0 cm⁻¹ |
| Display | 640 × 480 pixel color TFT touchscreen |
| Data Storage | Up to 10,000 readings with timestamp and user ID |
| Connectivity | USB, IrDA, RS-232C, Ethernet (RJ45) |
| Power | 9 VDC, 3.3 A, center-negative |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 848 |
| Titration Principle | Potentiometric Endpoint Detection |
| Burette Resolution | 1/10,000 |
| Input Signal Resolution | High-resolution analog-to-digital conversion |
| Control Interface | Keyboard & USB Mouse |
| Display | Integrated high-contrast LCD with real-time titration curve plotting |
| Stirring Options | Compatible with 801 Magnetic Stirrer or 802 Spiral Stirrer |
| Compliance | GLP/GMP-compliant data handling, ASTM E202–22, ISO 8655-3, USP <541>, FDA 21 CFR Part 11 ready (with optional software modules) |
| Connectivity | RS232, USB Host (for printer, keyboard, mouse, barcode scanner, USB storage), Remote I/O for autosamplers (e.g., 869 Compact Sample Processor) |
| Software Support | tiamo™ PC software for method development, data acquisition, audit trail, electronic signatures, and LIMS integration |
| Measurement Modes | SET (set endpoint), MET (equivalence point), DET (dynamic titration), pH/mV/T measurement, 5-point pH calibration |
| Optional Modules | Photometric titration (523 nm / 610 nm), Polarographic titration (Ipol/Upol) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA35 |
| Maximum Sample Capacity | 35 g |
| Readability | 0.01% |
| Sensor Resolution | 1 mg |
| Repeatability | ±0.2% (for initial sample mass ≥ 1 g), ±0.05% (for initial sample mass ≥ 5 g) |
| Moisture Display Modes | % moisture, % dry matter (solids), % ratio, final dried mass (g) |
| Heating Source | Infrared dark-field metal heating tube |
| Temperature Range | 40–160 °C (adjustable in 1 °C increments) |
| Drying Time Range | 0.1–99 minutes |
| Heating Chamber | Flip-open lid with wide opening angle |
| Compliance | FDA and HACCP-compliant (glass or optional aluminum sample pan insert) |
| GLP-Compliant Reporting | Optional thermal printer for audit-ready reports |
| Dimensions (W × D × H) | 224 × 366 × 191 mm |
| Weight | Approx. 5.8 kg |
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MA100 |
| Price Range | USD 7,000–14,000 (FOB) |
| Heating Source | Halogen Lamp |
| Maximum Capacity | 100 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1% (≥1 g sample), ±0.02% (≥5 g sample) |
| Temperature Range | 30–200 °C |
| Temperature Increment | 1 °C |
| Drying Modes | Automatic, Semi-Automatic, Timer-Based, SPRM (Smart Parameter Recognition Mode) |
| Predefined Programs | 30 |
| Display Units | % Moisture, % Dry Matter, g Dry Matter, % Ratio, Evaporated Mass (mg), Residue (g/kg), Custom Multiplier Output |
| Interface | RS-232 (RS-485 optional) |
| Built-in Printer | Optional |
| Sample Pan Diameter | 90 mm |
| Compliance | ISO 8573-3, DIN 53149, GLP/GMP-ready with audit trail support (via optional software) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Model | pH6+ |
| Instrument Type | Portable |
| Measurement Parameters | pH, ORP, Temperature (°C) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| ORP Range | ±1000 mV |
| ORP Resolution | 0.1 mV (up to 199.9 mV), 1 mV (above) |
| ORP Accuracy | ±2 mV ±1 LSD |
| Calibration Points | 3-point (pH) |
| Buffer Standards | USA, NIST, PWB |
| ATC/MTC Compensation | 0–100 °C |
| Auto-Off | After 20 min inactivity |
| Power Supply | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Display | LCD (4.5 × 2.3 cm) |
| Dimensions (unit) | 14 × 17 × 3.5 cm |
| Weight (unit) | 200 g |
| Packaging Dimensions | 36 × 28 × 8 cm |
| Packaging Weight | 1500 g |
Show next