Empowering Scientific Discovery

Jingyi Xingye Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGC-2010 Pro
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature RangeAmbient +4 °C to 450 °C
Oven Ramp Rate–250 to +250 °C/min (programmable)
Oven Cool-down Time≤3.4 min (450 °C → 50 °C)
Carrier Gas Flow Range & Control0–1250 mL/min (7-segment programming)
Carrier Gas Pressure Range & Control0–1035 kPa (7-segment programming)
Injector Maximum Temperature450 °C
Injector Pressure Setting Range0–1035 kPa
Injector Total Flow Setting Range0–1250 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGC-2014C
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature Control Range75–120 °C/min (ramp rate)
Temperature Ramp100–450 °C in 4.5 min
Cooling Rate100–0 °C in 4.5 min
Carrier Gas Flow Range & Control0–200 mL/min
Carrier Gas Pressure Range & Control150–700 kPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range100–500 kPa
Injector Total Flow Setting Range200–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGC-2014
Instrument TypeBenchtop Laboratory Gas Chromatograph
Temperature Control RangeAmbient +10 °C to 420 °C (–50 °C to 420 °C with liquid CO₂ cooling)
Maximum Ramp Rate250 °C/min
Cooling RateFrom 300 °C to 50 °C in <6 min
Carrier Gas Flow Range & Control0–1250 mL/min
Carrier Gas Pressure Range & Control0–1035 kPa
Injector Maximum Operating Temperature420 °C
Injector Pressure Setting Range0–1035 kPa
Injector Total Flow Setting Range0–1250 mL/min
Oven Volume15.8 L
Temperature Stability vs. Ambient Drift±0.01 °C/°C
Programmable Temperature Segments20 (including cooling ramps)
Programmed Ramp Rate Range–250 to +250 °C/min
Injector Types SupportedSplit/Splitless, Dual/Packed Column
Max Simultaneous Inlets3
Max Simultaneous Detectors4
Detector Temperature RangeUp to 420 °C (FID, TCD, FTD-S)
Display240 × 320-pixel graphical LCD (30 char × 60 line)
Dimensions (W×H×D)607 × 690 × 400 mm
Weight48 kg (GC-2014AF configuration)
Power SupplyAC 200 V, 1800 VA, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelNexis GC-2030
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature RangeAmbient +2 °C to 450 °C
Maximum Ramp Rate250 °C/min
Cool-down Time≤3.4 min (from 450 °C to 50 °C at ambient 22 °C)
Carrier Gas Flow Control Range0–1250 mL/min (7 programmable segments)
Carrier Gas Pressure Control Range0–1035 kPa (7 programmable segments)
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–1035 kPa
Injector Total Flow Setting Range0–1300 mL/min (He or H₂), 0–600 mL/min (N₂)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0