Empowering Scientific Discovery

Jingyi Xingye Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Distributor StatusAuthorized Distributor
ModelUVM-4020
Instrument TypeOnline Analyzer
Measurement PrincipleWeighted Multi-Wavelength Ultraviolet Absorption Spectrophotometry (UV-Vis)
Wavelengths243 nm, 254 nm, 265 nm, 275 nm, and 290 nm (simultaneous acquisition with spectral weighting)
Measurement Ranges0–400 SAC, 0–200 SAC, 0–80 SAC
Cycle TimeMinimum 1 minute
Power Supply220 V ±10 V, 50/60 Hz, ~100 VA
Operating Environment5–40 °C, ≤90% RH (non-condensing, non-freezing)
Sample Flow Rate1–2 L/min
Sample Pressure≤50 kPa
CalibrationAutomated zero/span calibration (optional reagent-free standard solutions)
Conversion FunctionsSimultaneous real-time calculation of COD, BOD, TOC, and SAC using 30 built-in empirical correlation models
CleaningScheduled internal tubing purge via user-defined intervals
InstallationIndoor wall- or rack-mounted configuration
ComplianceDesigned for continuous operation under ISO 5667-3, ASTM D5540, and EPA Method 415.3-aligned monitoring workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Manufacturer StatusAuthorized Distributor
Product OriginDomestic (China)
ModelCOD-4200
Price RangeUSD 21,000 – 28,000 (est.)
Instrument TypeOnline Analyzer
Measurement PrincipleHigh-Temperature Acidic Potassium Dichromate Digestion with Photometric Detection
Accuracy±10% for concentrations ≥100 mg/L
Minimum Measurement Cycle20 minutes
Measuring Range30–4000 mg/L COD (extended range available upon consultation)
Repeatability≤±5%
Zero Drift±5 mg/L
Span Drift≤±5%
Resolution<1 mg/L
Output SignalsRS-232, 4–20 mA (bidirectional communication & remote control supported)
Power Supply220 VAC ±10%, 50 Hz ±5%
Power Consumption~100 VA
Dimensions500 × 420 × 1550 mm (W × D × H)
Weight~90 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelDO6+
Measurement PrincipleGalvanic Cell Electrode
Dissolved Oxygen Range0.00–19.99 mg/L (ppm)
Resolution0.01 mg/L
Accuracy±1.5% of full scale
Saturation Range0.0–199.9%
Resolution0.1%
Temperature Range0.0–50.0 °C (32–122 °F)
Temp. Resolution0.1 °C
Temp. Accuracy±0.5 °C
Salinity Compensation0.0–50.0 ppt (manual input, automatic correction)
Pressure Compensation500–1499 mmHg or 66.6–199.9 kPa (manual input, automatic compensation)
CalibrationTwo-point (0% and 100% O₂)
Temperature CompensationATC/MTC (0.0–50.0 °C)
Electrode TypeGalvanic (self-polarizing) sensor
Response Time (t₉₅)≤60 s
Data Hold & Auto-OffYes (20 min inactivity)
DisplaySingle-line LCD
Input InterfacesBNC + 2.5 mm audio jack
Power4 × AAA alkaline batteries
Battery Life>700 hours
Dimensions (instrument)14 × 17 × 3.5 cm
Weight (instrument)200 g
Packaging Dimensions24 × 17 × 8 cm
Weight (shipping)0.55 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
Manufacturer StatusAuthorized Distributor
Product OriginImported
ModelTOC-L
Price RangeUSD 13,500 – 27,000 (FOB Japan)
Instrument TypeLaboratory TOC Analyzer
Detection PrincipleHigh-Temperature Catalytic Combustion Oxidation
Oxidation Temperature680 °C
Measurement Range4 µg/L to 30,000 mg/L as C
Detection MethodNDIR (Non-Dispersive Infrared)
Sample TypesLiquid aqueous matrices including ultrapure water, wastewater, seawater, and industrial process water
ComplianceDesigned to meet ASTM D7573, ISO 8245, USP <643>, and EP 2.2.44 requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
ModelTOC-4200
Measurement PrincipleCatalytic Combustion Oxidation + NDIR CO₂ Detection
Oxidation Temperature680 °C
Measurement Range0–1 ppm to 0–20,000 ppm (selectable)
Accuracy±1.0% of reading
Detection Limit0.01 ppm
Resolution0.001 ppb
Repeatability≤1% RSD
Analysis CycleMinimum 4 minutes
Carrier GasHigh-purity nitrogen (≥99.99%, 250–300 kPa)
Power Supply90–260 V AC, 50/60 Hz, 6 A
Power Consumption200 W (at operating temperature)
Operating Environment0–40 °C, ≤90% RH, indoor installation only
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Model420D-01A
Instrument TypePortable
Measurement PrincipleFluorescence-based (RDO) and Polarographic DO
pH Range−2.000–20.000
pH Resolution0.001
pH Accuracy±0.001
pH Calibration PointsUp to 5
mV Range±2000.0 mV
mV Resolution0.1 mV
DO Concentration (RDO)0–50 mg/L
DO Accuracy (RDO)±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% of reading (20–50 mg/L)
DO Saturation0–500%
Saturation Accuracy±2%
Temperature Range−5 to 105 °C
Temp Resolution0.1 °C
Temp Accuracy±0.1 °C
Data Storage5000 GLP-compliant entries
Protection RatingIP67 (portable unit)
InterfaceUSB, RS232
Power4×AA batteries or AC adapter
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0