- All
- Favorite
- Popular
- Most rated
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Instrument Type | Class II Type A2 Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1340 × 753 × 1400 mm |
| Internal Dimensions (L×W×H) | 1220 × 580 × 660 mm |
| Filter Efficiency | ≥99.999% for 0.1–0.3 µm particles |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | VBD-4A1 |
| Cabinet Class | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1247 × 760 × 1966 mm (adjustable up to 2271 mm height) |
| Internal Dimensions (L×W×H) | 1040 × 680 × 594 mm |
| Inflow Air Velocity | 0.35 m/s (70 fpm) |
| ULPA Filter Efficiency | ≥99.999% @ 0.12 µm |
| Power Supply | 220–240 VAC, 50 Hz |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | LA2-4A1 |
| Certification Standards | NSF/ANSI 49, YY0569, EN 12469, JIS K 3800, SANS 12469 |
| ULPA Filtration Efficiency | ≥99.999% for particles >0.12 µm |
| Noise Level | <57.5 dBA (per EN 12469) |
| External Dimensions (L×W×H) | 1420 × 815 × 1540 mm |
| Internal Work Area (L×W×H) | 1260 × 623 × 670 mm |
| Ergonomic Design | 10° inclined sash and work surface |
| Antimicrobial Coating | Isoceide™ on exterior surfaces |
| Control System | Sentinel™ microprocessor-based digital interface |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 04714-51 |
| Output Power | 130 W |
| Frequency | 20 kHz |
| Probe Tip Diameter | 6 mm |
| Sample Volume Range | 10–50 mL |
| Dimensions (L×W×H) | 115 × 250 × 320 mm |
| Net Weight | 3 kg |
| Timer Range | 1 s – 10 min (digital) |
| Pulse Mode | On/Off cycles adjustable from 0.1 s to 10 s each |
| Transducer Type | CV18 PZT piezoelectric converter (Ø32 mm × 146 mm, 340 g) |
| Probe Material | Ti-6Al-4V titanium alloy |
| Input Voltage | 220 V / 50 Hz |
| Display | 3-digit LCD wattmeter |
| Remote Control | Footswitch interface provided |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 04711-65 (750 W), 04711-75 (500 W) |
| Output Power | 500 W / 750 W |
| Frequency | 20 kHz |
| Probe Tip Diameter Options | 2, 3, 6, 13, 19, 25 mm |
| Sample Volume Range | 250 µL – 1000 mL (batch) |
| Timer Range | 1 s – 10 h |
| Pulse Mode | On/Off duration adjustable from 0.1 s to 10 s |
| Transducer | CV33 PZT ceramic, sealed housing, 63.5 mm Ø × 183 mm L, 900 g |
| Standard Probe | 13 mm Ti-6Al-4V titanium alloy, 136 mm L, 340 g |
| Dimensions (Generator) | 235 × 190 × 340 mm |
| Weight (Generator) | 7 kg |
| Input Power | 220 V, 50 Hz |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Instrument Type | Class II, Type B2 Biosafety Cabinet |
| External Dimensions (L×W×H) | 1340 × 811 × 2171 mm |
| Internal Dimensions (L×W×H) | 1270 × 585 × 670 mm |
| Filter Efficiency | ≥99.999% (ULPA/HEPA) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | KS 4000 ic control |
| Shaker Type | Refrigerated/Heated Orbital Incubator Shaker |
| Temperature Range | Ambient −10 °C to 80 °C |
| Speed Range | 10–500 rpm |
| Orbit Diameter | 20 mm |
| Max Load (incl. clamps) | 20 kg |
| Timer Range | 1–59,940 min (or 0–999 h) |
| Cooling Interface | External chiller port (e.g., RC 2 basic/control) |
| Temp Control Accuracy (0.5 L water, 37 °C setpoint) | ±0.5 K |
| Temp Uniformity (5×0.5 L vessels, 37 °C) | ±0.5 K |
| Temp Stability (single 0.5 L vessel) | ±0.05 K |
| Power Input | 1120 W |
| Dimensions (W×D×H) | 580 × 520 × 750 mm |
| Weight | 55 kg |
| IP Rating | IP30 |
| Compliance | DIN EN 60529, CE |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Cabinet Type | Class II, Type B2 (Total Exhaust) |
| Certification | NSF/ANSI 49, YY0569 |
| Filter Efficiency | ≥99.999% for particles ≥0.1 µm (ULPA) |
| Inflow Velocity | 0.53 m/s (105 fpm) |
| Downflow Velocity | 0.31 m/s (60 fpm) |
| Power Supply | 220 VAC, 50 Hz |
| Construction | Seamless stainless steel work chamber |
| Motor | Brushless DC motor |
| Control System | Esco Sentinel Gold microprocessor-based interface |
| Compliance | Meets IEST-RP-CC001.3 for ULPA filter performance |
| Airflow Configuration | Unidirectional downflow + total external exhaust |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | KS 501digital |
| Speed Range | 0–300 rpm (infinitely variable) |
| Orbit Diameter | 30 mm |
| Max Load Capacity | 15 kg |
| Display | Digital LED |
| Timer Function | Yes |
| Compliance | CE, ISO 9001 certified manufacturing |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 04711-35 (500 W), 04711-45 (750 W) |
| Instrument Type | Ultrasonic Cell Disruptor |
| Power Output | 500 W / 750 W |
| Frequency | 20 kHz |
| Sample Volume Range | 250 µL – 1000 mL |
| Continuous Flow Rate | up to 19 L/h |
| Temperature Control Range | 1–100 °C |
| Timer Range | 1 s – 10 h |
| Pulse Cycle | On/Off adjustable from 0.1 s to 10 s |
| Probe Material | Ti-6Al-4V titanium alloy |
| Transducer | CV33 PZT ceramic, sealed housing |
| Dimensions (Generator) | 235 × 190 × 340 mm |
| Weight (Generator) | 7 kg |
| Input Power | 220 V / 50 Hz |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | VORTEX 3 |
| Oscillation Frequency | 0–2500 rpm |
| Orbit Diameter | 4 mm |
| Operating Mode | Continuous & Touch-Start (Pulse) |
| Dimensions (W × D × H) | 127 × 136 × 149 mm |
| Weight | 4.5 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Input Power | 60 W |
| Protection Class | IP21 |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % |
| Motor Output Power | 10 W |
| Motor Input Power | 58 W |
| Duty Cycle | 100 % continuous operation |
| Minimum Adjustable Speed | 500 rpm |
| Plate Compatibility | Single standard platform (no heating/cooling) |
| Microplate Support | Yes (1 × 96-well plate) |
| Foot Material | Silicone vibration-damping feet |
| Housing Material | Die-cast zinc |
| Bearing Type | Eccentric ball bearing |
| Ventilation | Optimized motor airflow design |
| Timer | None |
| Display | None |
| RS232 Interface | No |
| Analog Output | No |
| Compliance | DIN EN 60529 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | MS 3 basic |
| Oscillation Frequency | 0–3000 rpm |
| Oscillation Amplitude | 4.5 mm |
| Platform Quantity | 1 |
| Operating Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Rating | IP21 |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Power Consumption | 20 W |
| Dimensions (W×H×D) | 148 × 205 × 63 mm |
| Weight | 2.9 kg |
| Max Load Capacity (incl. fixture) | 0.5 kg |
| Motor Output Power | 8 W |
| Minimum Adjustable Speed | 200 rpm |
| Display | LED speed indicator |
| Operation Modes | Continuous & Pulse (with standard plate adapter) |
| Plate Compatibility | Standard microtiter plates (96-well), PCR plates, small tubes (e.g., 1.5–2.0 mL), vials, and cuvettes |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HS 260 control |
| Price | Upon Request |
| Motion Type | Reciprocal |
| Orbit Diameter | 20 mm |
| Max Load Capacity (incl. clamp) | 7.5 kg |
| Motor Input Power | 45 W |
| Motor Output Power | 10 W |
| Duty Cycle | 100 % |
| Speed Range | 10–300 rpm |
| Speed Display | LCD |
| Timer | Yes |
| Timer Display | LCD |
| Timer Setting Range | 1–599 min |
| Operation Modes | Timed & Continuous |
| Benchtop Vibration Damping | Yes |
| Dimensions (W×H×D) | 360 × 100 × 420 mm |
| Weight | 8.8 kg |
| Ambient Temperature Range | 5–50 °C |
| Relative Humidity Limit | 80 % |
| Ingress Protection | IP21 (DIN EN 60529) |
| RS232 Interface | Yes |
| Analog Output | Yes |
| Voltage | 220–240 V / 100–120 V |
| Frequency | 50/60 Hz |
| Device Input Power | 45 W |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Cabinet Type | Class II, Type A2 |
| Certification | EN 12469 compliant |
| Filter Efficiency | ≥99.999% @ 0.3 µm (ULPA) |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.30 m/s (60 fpm) |
| External Dimensions (AC2-4D) | 1340 × 753 × 1400 mm (w/o armrest), 1340 × 810 × 1400 mm (w/ armrest) |
| Internal Dimensions (AC2-4D) | 1220 × 580 × 660 mm |
| Power Supply | 220 V, 50 Hz |
| Work Surface | Seamless stainless steel, integral arch spill containment |
| Antimicrobial Coating | Esco ISOCIDE® on all external and internal surfaces |
| Control System | EscoSentinel Gold microprocessor-based display with real-time airflow monitoring |
| Communication Interface | RS-232 for BMS integration |
| Ergonomic Features | Adjustable armrests, sloped front grille, footrest option, height-adjustable base options |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Cabinet Type | Class II, Type A2 |
| Filter Efficiency | 99.999% (ULPA, 0.1–0.3 µm) |
| Power Supply | 220 VAC, 50 Hz |
| Compliance | NSF/ANSI 49, EN 12469, YY 0569, JIS K 3800 |
| Airflow | Inflow 0.53 m/s (105 fpm), Downflow 0.35 m/s (70 fpm) |
| Construction | Seamless stainless steel work area, ISOCIDE® antimicrobial powder coating |
| Control System | Sentinel Gold™ microprocessor-based digital display with RS232 port |
| Ergonomics | 10° front tilt, ADA-compliant angled control panel and display |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Instrument Type | Class II Type A2 Biological Safety Cabinet |
| Filter Efficiency | ≥99.999% for 0.1 µm particles (ULPA-grade) |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.30 m/s (60 fpm) |
| Power Supply | 230 V, 50/60 Hz |
| Compliance | EN 12469:2000, NSF/ANSI 49-2022, IEST-RP-CC001-2022 (equivalent to EN 1822 H14) |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | LB2-4B1 |
| Certification | NSF/ANSI 49 & YY0569 |
| ULPA Downflow Filter Efficiency | >99.999% for particles ≥0.12 µm |
| HEPA Exhaust Filter Efficiency | >99.99% for particles ≥0.3 µm |
| Noise Level (per EN 12469) | <58 dBA |
| External Dimensions (L×W×H) | 1420 × 815 × 1568 mm |
| Internal Work Area (L×W×H) | 1260 × 623 × 715 mm |
| Construction | 304 Stainless Steel Work Surface, Isocide™ Antimicrobial Coating, Seamless Front Intake & Sloped Ergonomic Design |
| Brand | Analytik Jena (Biometra) |
|---|---|
| Origin | Germany |
| Model | OV1 / OV3 / OV5 |
| Chamber Construction | Double-glazed vacuum-insulated door (OV3 & OV5) |
| Hybridization Vessel Design | Uniform-diameter rotating bottles with bottle-angling geometry |
| Fluid Distribution | Continuous buffer flow across membrane surface via optimized bottle orientation |
| Membrane Capacity | Multiple membranes per bottle using integrated nylon mesh support |
| Motion Control | Adjustable-speed oscillating platform (OV3 & OV5) |
| Configuration Flexibility | Dual-mode operation — static hybridization (OV1-style) and dynamic agitation (OV3/OV5), with OV5 supporting concurrent independent hybridization protocols |
Show next