Laser Confocal Microscope
Filter
Showing 31–60 of 78 results
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | STELLARIS DLS |
| Instrument Type | Point-Scanning Confocal Microscope with Integrated Digital Light Sheet Module |
| Integration Compatibility | STELLARIS 5 and STELLARIS 8 platforms |
| Optical Architecture | Inverted microscope with vertical dual-axis light sheet generation via TwinFlect mirror system |
| Illumination | Scanned Gaussian or top-hat light sheet (405–785 nm excitation range) |
| Detection | Dual sCMOS cameras (optional high-speed or high-sensitivity configuration) |
| Sample Mounting | Standard glass-bottom dishes, U-shaped capillaries, FEP tubing, or custom mounting frames (24 × 50 mm rectangular / Ø30 mm circular) |
| Refractive Index Matching | Compatible with water, glycerol, BABB, Scale, CUBIC, and other clearing media |
| Software Platform | LAS X LightSheet Wizard with real-time fusion, environmental control module, 3D Visualization, and GLP-compliant audit trail (21 CFR Part 11 ready) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Instrument Type | Point-Scanning Confocal Microscope |
| Model | STELLARIS SpectraPlex |
| Spectral Unmixing Capacity | >15 fluorophores per acquisition |
| Workflow Integration | Aivia AI-powered analysis platform |
| Compliance | Designed for GLP/GMP-aligned spatial biology workflows, compatible with ISO 13485–informed documentation practices |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | Leica STELLARIS STED |
| Instrument Type | Point-Scanning Confocal Microscope |
| STED Laser Wavelengths | 592 nm, 660 nm, 775 nm |
| Excitation Range | 440–790 nm (White Light Laser) |
| Detection | Up to 5 spectral Power HyD detectors (HyD S/X/R), 1.5 ns system dead time |
| Objective Support | STED-optimized STED WHITE 100× oil, 93× glycerol (motCORR), 86× water (motCORR) |
| Resolution | <30 nm lateral, <100 nm axial (sample- and fluorophore-dependent) |
| Core Technology | Time-gated STED (TauSTED Xtend), TauSense-enabled lifetime discrimination, FLIM-capable with FALCON module |
| Software Platform | LAS X with ImageCompass, LAS X Navigator, TauSense tools |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | STELLARIS STED |
| Excitation Wavelength Range | 440–790 nm (White Light Laser) |
| STED Depletion Wavelengths | 592 nm, 660 nm, 775 nm |
| Spatial Resolution | <30 nm (lateral), <100 nm (axial), sample- and fluorophore-dependent |
| Detection | Up to 5 spectral Power HyD detectors with 1.5 ns system dead time |
| Objective Options | STED WHITE 100× oil, 93× glycerol (motCORR), 86× water (motCORR) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 CARS |
| Laser Modalities | Visible, UV, IR, SHG, CARS |
| Imaging Modes | Single-photon fluorescence, multiphoton fluorescence, CARS, SHG, spectral unmixing |
| Scan Systems | Dual scanning architecture (standard resonant + high-speed resonant/galvo) |
| Software Platform | LAS X (successor to LAS AF), FDA 21 CFR Part 11 compliant modules available |
| Compliance | ISO 13485–certified manufacturing, CE-marked, GLP/GMP-ready audit trail support |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 DLS |
| Imaging Principle | Orthogonal light-sheet illumination integrated with confocal detection |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 |
| Type | Laser Scanning Confocal Microscope |
| Optical Architecture | Upright or Inverted Configurable Platform |
| Detection Principle | Point-scanning confocal fluorescence imaging with spectral detection and time-gated photon counting capability |
| Maximum Frame Rate | 428 fps (at 512 × 32 resolution) |
| Field of View | Up to 22 mm diagonal (with resonant scanner and wide-field optics) |
| Scan Modes | Galvoscanner, Resonant Scanner, Galvoflow (combined galvo-resonant hybrid mode for accelerated Z-stack acquisition) |
| Detector Options | Hybrid Detectors (HyD), PMTs, Spectral Detectors (Tuneable Bandpass or Linear Unmixing) |
| Excitation Sources | Integrated white-light laser (WLL, 470–670 nm), optional UV/IR lasers, acousto-optic tunable filters (AOTF) |
| Software Platform | LAS X (v3.7+), compliant with FDA 21 CFR Part 11 audit trail and electronic signature modules |
| Compliance | CE, IEC 61000-6-3, ISO 13485 (for medical device configurations), GLP/GMP-ready metadata logging |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 MP |
| Instrument Type | Point-Scanning Multiphoton Confocal Microscope |
| Excitation Range | 680–1300 nm |
| Maximum IR Wavelength | 1300 nm |
| Resonant Scanner Speed | 8 kHz / 12 kHz |
| Field of View (FOV) | up to 22 mm |
| Detection | Leica HyD NDD & HyD RLD non-descanned detectors |
| Objective Correction | motCORR electrically adjustable correction collar |
| Specialized Objectives | HC IRAPO L 25×/1.00 W motCORR, HC FLUOTAR L 25×/1.00 IMM (ne=1.457) motCORR VISIR, APO HCX L20×/0.95 IMM for BABB immersion (ne=1.559) |
| Software Platform | LAS X with integrated multiphoton control, FLIM wizard, and STED/FLIM/SMD module compatibility |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 SMD |
| Application Domain | Single-Molecule Detection (SMD), Fluorescence Correlation Spectroscopy (FCS), Fluorescence Cross-Correlation Spectroscopy (FCCS), Fluorescence Lifetime Imaging Microscopy (FLIM), Fluorescence Lifetime Correlation Spectroscopy (FLCS) |
| Integrated Hardware Platform | PicoQuant MD-series detection modules and timing electronics |
| Software Integration | PicoQuant SymPhoTime 64 (SMD-optimized edition) |
| Optical Architecture | Inverted confocal platform with tunable white-light laser (WLL), spectral detection (HyD detectors), and time-correlated single-photon counting (TCSPC) capability |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 X |
| Excitation Source | Tunable White Light Laser (WLL), Pulsed |
| Detection Channels | Up to 5 Spectral Detection Channels |
| Excitation Lines | Up to 8 Simultaneous Lines |
| FLIM Compatibility | Yes, with Adjustable Repetition Rate via Pulse Picker |
| LightGate Technology | Time-Gated Spectral Detection |
| Spectral Resolution | Continuous Excitation & Emission Acquisition (Excitation–Emission Matrix Mapping) |
| Application Scope | Live-Cell Imaging, Multicolor Fluorescence, Spectral Unmixing, FLIM, pH/Binding Microenvironment Analysis |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 X |
| Excitation Source | Tunable White Light Laser (WLL), Pulsed |
| Detection | Spectral Detection with Adjustable Bandpass, Up to 8 Simultaneous Excitation Lines |
| Fluorescence Lifetime Imaging (FLIM) Capability | Yes |
| Scan Mode | Galvo + Resonant Scanner |
| Zoom Optics | Continuous Spectral Zoom (λ-Zoom) |
| Microscope Frame | Inverted or Upright Configurable Platform |
| Vibration Isolation | Compatible with Active Damping Optical Tables |
| Software | LAS X Professional Suite with Spectral Unmixing, FLIM Analysis, and GLP-Compliant Audit Trail Modules |
| Compliance | Designed for ISO 13485-aligned workflows |
| Brand | Lyncee Tec |
|---|---|
| Origin | Switzerland |
| Model | DHMT1001 |
| Light Source | Single-wavelength laser |
| Camera Resolution | 1392 × 1040 pixels, 8-bit |
| Vertical Resolution | 0.2 nm (instantaneous, in air) |
| Lateral Resolution | 300 nm (with 100× oil immersion objective, NA 1.4) |
| Imaging Speed | 15 fps at 512 × 512, 4 fps at 1024 × 1024 |
| Field of View | Up to 4.40 mm (dependent on objective) |
| Sample Stage | Manual XYZ (25 mm travel), optional motorized 2-/3-axis control |
| Software | Koala Software (C++/.NET, Windows XP-compatible) |
| Power Supply | 85–260 VAC, 50/60 Hz, <120 W |
| Dimensions | 400 × 400 × 500 mm, 34.5 kg |
| Brand | Nanolnsights |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SpinX |
| Pricing | Available Upon Request |
| Resolution | X-Y = 140 nm, Z = 450 nm |
| Excitation Wavelength Range | 400–750 nm |
| Detection Channels | Fluorescence + Brightfield |
| Fluorescence Detector | Scientific CMOS (sCMOS) Camera |
| Objective Lenses | 10×, 20×, 40×, 60×, 100× (oil/water immersion compatible) |
| Microscope Host | Fully Automated Motorized Platform |
| Illumination Source | Metal Halide Lamp / High-Power LED |
| Control Software | Dual-Mode Intelligent Suite (Beginner & Advanced Modes) |
| Vibration Isolation Table | 1.2 × 1.2 m Dedicated Anti-Vibration Platform |
| XY Stage Drive | Precision Motorized Linear Actuation |
| Brand | Nexcope |
|---|---|
| Origin | Zhejiang, China |
| Model | NCF1000 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Field of View | Φ25 mm (25 mm diameter circular field, square imaging area up to 8192 × 8192 pixels) |
| Lasers | 405 nm, 488 nm, 561 nm, 640 nm |
| Detectors | 4-channel PMT (standard), spectral detector (400–750 nm, 1 nm tuning resolution, up to 4 GaAsP PMTs), transmission PMT detector |
| Scan Modes | X, Y, Z, λ (spectral), and T (time-lapse) — fully combinable |
| Pinhole | Motorized continuous adjustment |
| Objective Lenses | 4×/0.16, 10×/0.45, 20×/0.75, 40×/0.95, 60×/1.42, 100×/1.45 & 100×/1.49 (oil immersion, coverslip-corrected) |
| Microscope Host | NIB1000-AT motorized inverted research-grade platform with NIS60 infinity optical system |
| Illumination | Epifluorescence LED light source (4-band, 6-position motorized filter turret: B/G/U standard |
| Software | Nomis Pro X-C (confocal scanning control, multi-dimensional acquisition, channel presets, hardware-integrated operation, 16-bit image output, real-time deconvolution & basic filtering) |
| XY Stage | Motorized grating-based, 130 mm × 100 mm travel, 0.1 µm positioning accuracy, 0.5 µm repeatability |
| Z Focus | Motorized, 10 mm range, 0.02 µm minimum step, 0.1 µm repeatability |
| Adaptive Focus Stabilization (AFS) | Real-time focal plane maintenance during time-lapse imaging |
| Optional Modules | SR-SIM super-resolution upgrade (2D-SIM lateral resolution ≤85 nm, 3D-SIM axial resolution ≤270 nm |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | AX / AXR |
| Type | Upright Laser Scanning Confocal Microscope System |
| Optical Architecture | Dual-galvo scanning with resonant scanner option |
| Detection | GaAsP hybrid detectors (HyD) with spectral unmixing capability |
| Objective Compatibility | Nikon CFI Plan Apo λ series, 10×–100×, oil/water/glycerol immersion |
| Laser Lines | 405 nm, 488 nm, 561 nm, 640 nm (standard), optional UV and IR lines |
| Maximum Imaging Speed | Up to 30 fps at 512 × 512 resolution (resonant mode) |
| Z-resolution | < 0.1 µm (with piezo stage and deconvolution) |
| Software Platform | NIS-Elements AR/CV with AI-powered denoising and 3D/4D reconstruction modules |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | AX R MP |
| Optical System | Infinity-Corrected |
| Frame Type | AX-FNSP (Upright) / AX-FNGP (Gantry) |
| Focus Unit | AX-FN Motorized Coaxial Coarse/Fine Focus |
| Focus Travel | +13 mm / –2 mm |
| Minimum Step Size | 0.02 µm |
| Focal Plane Height | 400 mm above Vibration-Isolation Table |
| Controller | AX-FNCTL Main Controller + AX-FNHC Hub Controller (manages objective focus, transmitted illumination, joystick, motorized epi-fluorescence filter turret, ergonomic motorized quad-port head, DSC zoom port) |
| Scanning | 2K Resolution Resonant Scanner |
| Imaging Mode | Multiphoton Excitation + Confocal Detection |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | AX with NSPARC |
| Detector Type | NSPARC (Nikon Spatially Resolved Array Photon Counter) |
| Lateral Resolution | 100 nm |
| Axial Resolution | 300 nm |
| Scan Head Options | AX-SHS (Galvo-only), AX-SHR (Galvo + Resonant) |
| Field of View | 25 mm |
| Max Image Resolution | 8192 × 8192 pixels |
| Resonant Scan Speed | up to 720 fps @ 2048 × 16 px |
| Galvo Scan Speed | 10 fps @ 512 × 512 px |
| Pixel Dwell Time Range | 0.2 ms – 10 µs |
| Scan Modes | Unidirectional, Bidirectional, Line Scan, Rolling Average, Line Average |
| Real-time AI Denoising | Denoise.ai integrated |
| Emission Filter Capacity | Up to 7 positions (405/445/488/514/561/594/640 nm) |
| Excitation Compatibility | Multi-laser (405–640 nm) |
| Detector Architecture | SPPC (Single-Pixel Photon Counting) Array |
| Rotation Capability | ±180° image rotation |
| Software Platform | NIS-Elements AR/C |
| Brand | NIKON |
|---|---|
| Origin | Japan |
| Model | C1/C1si |
| Category | Laser Scanning Confocal Microscope |
| Optical Architecture | Upright/Inverted-Compatible Modular Scanning Head |
| Excitation Wavelength Range | 400–650 nm (with multi-laser AOTF control) |
| Pinhole Control | Motorized 4-position aperture wheel |
| Scan Modes | Bidirectional, Rotational (X/Y), Variable-interval Time-Lapse |
| Fluorescence Channels | Simultaneous 3-channel detection (optional DIC integration) |
| TIRF Compatibility | Yes, with Nikon CFI Apo TIRF 60×/100× NA 1.49 objectives |
| FRAP/FLIP/iFRAP Support | Software-enabled via dedicated photobleaching module |
| Laser Capacity | Up to 4 independent lasers (Ar+, HeNe, diode, DPSS) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-SIM E |
| Resolution (XY) | ~115 nm |
| Resolution (Z, 3D-SIM) | ~300 nm |
| Imaging Speed | ~1 frame/sec |
| Field of View | 66 µm × 66 µm |
| Objective Compatibility | High-NA objectives up to NA 1.49 |
| Modality | Structured Illumination Microscopy (SIM) with integrated confocal capability |
| 3D Reconstruction Modes | Slice and Stack |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-SIMS |
| Lateral Resolution (XY, FWHM) | 86 nm (TIRF-SIM), 115 nm (3D-SIM) |
| Axial Resolution (Z, FWHM) | 269 nm (3D-SIM) |
| Max Imaging Speed | 15 fps (TIRF-SIM/2D-SIM, 2 ms exposure) |
| Reconstruction Image Size | 1024 × 1024 or 2048 × 2048 pixels |
| Imaging Modes | TIRF-SIM, 2D-SIM, 3D-SIM (single-frame & time-series reconstruction) |
| Multicolor Capability | Up to 6 channels, simultaneous dual-color acquisition |
| Compatible Laser Units | LU-NV (std: 405/488/561/640 nm |
| opt | 445 nm), LUD-HV (std: same |
| opt | 445/515 nm), Ziva Light Engine (405/446/476/518/545/637 nm) |
| Compatible Microscope Platform | Nikon ECLIPSE Ti2-E motorized inverted microscope with Perfect Focus System (PFS), encoded motorized XY stage, and piezo-driven Z-stage |
| Objective Lenses | CFI SR HP Plan Apochromat Lambda S 100XC Sil (NA 1.35), CFI SR HP Apochromat TIRF 100XC Oil (NA 1.49), CFI SR HP Apochromat TIRF 100XAC Oil (NA 1.49), CFI SR Plan Apochromat IR 60XC WI (NA 1.27), CFI SR Plan Apochromat IR 60XAC WI (NA 1.27), CFI Plan Apochromat Lambda 60XC (NA 0.95), CFI Plan Apochromat Lambda 40XC (NA 0.95) |
| Camera | ORCA-Fusion BT sCMOS (Hamamatsu Photonics K.K.) |
| Software | NIS-Elements AR (with NIS-A 6D and N-SIM analysis modules required), NIS-Elements C (for AX/AX R confocal systems) |
| Operating Environment | 20–28 °C (±1.5 °C) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-STORM |
| XY Resolution | ~20 nm |
| Z Resolution | ~50 nm |
| Imaging Modes | 2D-STORM (n-STORM, c-STORM), 3D-STORM (n-STORM, c-STORM), 3D-Stack |
| Maximum Field of View | 80 µm × 80 µm |
| Frame Rate | up to 500 Hz |
| Multicolor Capability | up to 3 channels |
| Compatible Lasers | LU-NV Series (405/488/561/647 nm), LUD-H Series (405/488/561/640 nm) |
| Compatible Platform | Nikon ECLIPSE Ti2-E motorized inverted microscope |
| Autofocus System | Perfect Focus System (PFS) with encoder-based motorized XY stage and Piezo Z-stage |
| Objective Lenses | CFI SR HP Plan Apochromat Lambda S 100XC Sil (NA 1.35), CFI SR HP Apochromat TIRF 100XC oil (NA 1.49), CFI SR HP Apochromat TIRF 100XAC oil (NA 1.49), CFI HP Plan Apochromat VC 100X oil (NA 1.40) |
| Camera Options | ORCA-Fusion BT sCMOS (Hamamatsu), iXON Ultra DU-897U EMCCD (Andor) |
| Software | NIS-Elements AR / NIS-Elements C (optional), NIS-A 6D and N-STORM Analysis Module (required) |
| Operating Temperature | 20–25 °C (±0.5 °C) |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FV4000 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Resolution | High Spatial and Spectral Resolution |
| Lasers | Multiple NIR-capable laser lines (405–785 nm), optional 808/980 nm for upconversion |
| Detectors | Six-channel synchronous silicon-based photodetectors (SilVIR™), 400–900 nm spectral range |
| Fluorescence Detection | SilVIR™ visible-to-infrared silicon detectors with linear response, low noise, and >6-decade dynamic range |
| Scanning Module | Hybrid scanning unit supporting conventional galvo + resonant scanner |
| Scan Modes | Bidirectional resonant scanning, sequential/simultaneous spectral acquisition, Z-stack, time-lapse, tile scan |
| Scan Speed | Up to 438 fps at 1024 × 32 pixels |
| Optical Zoom | Continuous digital and optical zoom with wide dynamic magnification range |
| Objectives | Wide selection of high-NA oil/water/glycerol immersion and dry objectives (e.g., UPLSAPO 60×/1.35, LUCPLFLN 60×/1.20 W) |
| Microscope Frame | Research-grade fully motorized inverted, upright, electrophysiology, or “gate-type” stand |
| Illumination Sources | LED-based fluorescence excitation (white LED + filter wheels), optional halogen or LED brightfield |
| Software Platform | FLUOVIEW v5.x with AI-powered denoising, automated organoid detection, C. elegans motion tracking, and multi-modal experiment scripting |
| Vibration Isolation | Dedicated active/passive anti-vibration tables (multiple footprint options) |
| XY Stage Control | Motorized stage with remote joystick and full software API integration |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | IXplore SpinSR |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | IXplore IX85 SpinXL |
| Resolution (Lateral) | ~230 nm (with 1.4 NA objective) |
| Resolution (Axial) | ~600 nm (with 1.4 NA objective) |
| Lasers | 405 nm, 445 nm, 470 nm, 488 nm, 520 nm, 530 nm, 555 nm, 577 nm, 640 nm, 730 nm |
| Detectors | Up to 7 simultaneous channels |
| Scan Module | Integrated spinning-disk unit |
| Scanning Modes | Multi-mode acquisition (e.g., frame scan, line scan, ROI scan, time-lapse, Z-stack) |
| Objective Compatibility | Wide range of high-NA and correction-collared objectives (including silicone/oil/water immersion) |
| Microscope Host | Research-grade fully motorized inverted fluorescence microscope (IX85 platform) |
| Illumination Source | 89 North Laser Diode Illuminator (LDI) with independent intensity control per wavelength |
| Software & Workstation | Intelligent acquisition software with guided setup, hardware synchronization, and real-time feedback |
| Vibration Isolation | Dedicated active or passive anti-vibration optical table included |
| XY Stage Control | Motorized high-precision piezo-enhanced stage with closed-loop feedback |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OLS4100 |
| Pricing | Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | LEXT OLS4100 |
| Type | Laser Scanning Confocal Microscope |
| Optical Resolution (XY) | 0.12 µm |
| Axial Resolution (Z) | 10 nm |
| Laser Wavelength | 405 nm |
| Detection System | Dual-Confocal Optical Architecture |
| Measurement Modes | 7 |
| Imaging Modes | Confocal, DIC-Laser (Laser Differential Interference Contrast), Multi-Layer Surface Analysis |
| Vibration Isolation | Integrated Composite Damping Mechanism (Spiral Spring + Damping Rubber) |
| Compliance | Designed for ISO/IEC 17025-aligned metrology workflows, supports GLP/GMP documentation traceability |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | LEXT OLS4500 |
| Type | Hybrid Optical/Laser/Probe Microscope |
| Measurement Range | Millimeter to Nanometer Scale |
| Max Magnification | Up to 1,000,000× |
| Objective Lenses | Four Motorized Objectives (Low-to-Ultra-High Magnification) |
| SPM Integration | Integrated Lens-Type SPM Head on Motorized Nosepiece |
| SPM Modes | Contact, Dynamic, Phase, Current, Surface Potential, Magnetic Force (Optional) |
| Alignment | Coaxial and Confocal Objective–Cantilever Configuration |
| Automation | Guided Workflow for Rapid 3D Topography Acquisition and Analysis |
| Compliance | Designed for ISO/IEC 17025-aligned metrology workflows, supports GLP/GMP documentation traceability |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | OLS4500 |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LEXT OLS5100 |
| Pricing | Available Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LEXT OLS5500 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Laser Source | 405 nm wavelength, max output 0.95 mW, Class 2 laser (compliant with JIS C 6802:2018, IEC 60825-1:2014, EN 60825-1:2014/A11:2021, GB/T 7247.1-2024) |
| Scanning Module | Integrated design |
| Scan Speed & Resolution | Up to 4096 × 4096 pixels per single measurement |
| Objective Lenses | Interchangeable high-NA objectives including dedicated LEXT confocal and WLI objectives (up to NA 0.8) |
| Illumination | White LED for brightfield and contrast-enhanced imaging |
| Software Platform | Intelligent acquisition and analysis suite with automated parameter optimization |
| XY Stage Control | Motorized precision stage with sub-micron repeatability |