| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | TYZD-III |
| Price | USD 195 (FOB Shanghai) |
| Speed Range | 0–210 rpm |
| Timer Range | 0–60 min |
| Oscillation Amplitude | 22 mm |
| Platform Dimensions | 384 × 248 mm |
| Power Consumption | 10 W |
| Eccentric Rotation Diameter | 22 mm |
| Fuse Rating | 2 A |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TYZD-IIIA (Digital Display) |
| Instrument Type | Specialized Rotary Shaker for Serological Assays |
| Timer Range | 0–24 h (countdown mode |
| Oscillation Speed | 10–210 rpm (adjustable) |
| Orbit Diameter | 22 mm |
| Platform Quantity | 1 |
| Input Voltage | AC 220 V, 50/60 Hz |
| Power Consumption | 15 W |
| Fuse Rating | 2 A |
| Platform Dimensions | 314 × 218 mm |
| Display | Real-time digital readout of speed and remaining time |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | TYZD-IIIA |
| Instrument Type | Clinical Rotator for Serological Assays |
| Timing Range | 0–24 h (continuous mode at “0”) |
| Oscillation Speed | 10–210 rpm |
| Orbital Diameter | 22 mm |
| Platform Dimensions | 314 × 218 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Power Consumption | 15 W |
| Fuse Rating | 2 A |
| Display | Digital RPM and Timer |
| Brand | Hanuo |
|---|---|
| Model | TYZD-IIIA |
| Instrument Type | Rotary Shaker for Serological Assays |
| Timing Range | 0–24 h (countdown mode, “0” = continuous operation) |
| Oscillation Speed | 0–210 rpm |
| Stroke Amplitude | 22 mm |
| Platform Dimensions | 314 × 218 mm |
| Power Consumption | ≤15 W |
| Input Voltage | AC 220 V, 50/60 Hz |
| Fuse Rating | 2 A |
| Display | Digital LED showing real-time speed and remaining time |
| Number of Platforms | 1 |
| Temperature Control | None |
| Compliance | Designed for clinical laboratory use under GLP-aligned workflows |
| Key | Brand: Hanuo |
|---|---|
| Model | TYZD-IIIA |
| Origin | Shanghai, China |
| Oscillation Frequency Range | 10–210 rpm (adjustable) |
| Oscillation Amplitude | 22 mm (eccentric diameter) |
| Timer Range | 0–24 h (0 = continuous operation) |
| Platform Dimensions | 384 × 248 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Power Consumption | 15 W |
| Fuse Rating | 2 A |
| Number of Platforms | 1 |
| Temperature Control | None |
| Instrument Category | Clinical Diagnostic Oscillator |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | ULT-40-328L |
| Effective Volume | 328 L |
| Internal Dimensions (W×D×H) | 509 × 519 × 1393 mm |
| External Dimensions (W×D×H) | 673 × 676 × 1886 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 620 W |
| Operating Temperature Range | –10 °C to –40 °C |
| Net Weight | 128 kg |
| Brand | Hanuo |
|---|---|
| Model | UV-1000 |
| Type | Desktop Transilluminator |
| Wavelength Options | 254 nm, 302 nm, or 365 nm (single-wavelength selection) |
| UV Filter Size | 200 × 200 mm |
| UV Lamp Configuration | Eight 15 W low-pressure mercury lamps |
| Power Input | 120 V / 230 V, 50/60 Hz |
| Safety | Integrated UV-blocking acrylic shield with safety interlock |
| Compliance | CE-marked, RoHS-compliant |
| Dimensions (W × D × H) | 280 × 240 × 120 mm |
| Weight | 4.2 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2000 |
| Instrument Type | Darkroom-style transilluminator |
| Wavelength | 302 nm (single-band) |
| Transmission UV Filter Size | 200 × 150 mm |
| Reflective UV Filter Size | 200 × 80 mm |
| UV Lamp Power (Transmissive) | 64 W |
| UV Lamp Power (Reflective) | 24 W |
| White Light Illumination Power | 40 W |
| Input Voltage | 220 V AC |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-1 |
| Instrument Type | Benchtop |
| Wavelength Options | 254 nm (short-wave UV) and 365 nm (long-wave UV) |
| UV Lamp Power | 6 W (254 nm), 6 W (365 nm) |
| Visible Light Power | 4 W |
| UV Filter Glass Dimensions | 200 × 50 mm |
| Compliance | CE-marked for laboratory use under IEC 61010-1 safety standards |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-1B |
| Instrument Type | Darkroom-style transilluminator |
| Wavelength Options | 254 nm (short-wave UV), 365 nm (long-wave UV), and visible light (4W) |
| UV Filter Glass Dimensions | 200 × 50 mm |
| UV Lamp Power | 6 W (each for 254 nm and 365 nm) |
| Input Voltage | 220 V AC |
| Compliance | Designed for laboratory-grade qualitative fluorescence visualization under controlled ambient conditions |
| Intended Use | Gel documentation, fluorescent compound screening, forensic sample inspection, and thin-layer chromatography (TLC) analysis |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-1B |
| Instrument Type | Darkroom-style transilluminator |
| Wavelength Modes | 254 nm (short-wave UV), 365 nm (long-wave UV), and visible light (400–700 nm) |
| UV Lamp Configuration | 6 lamps (3 × 254 nm, 3 × 365 nm) |
| Power Rating | 50 W total (254 nm: 18 W |
| 365 nm | 18 W |
| visible | 14 W) |
| UV Filter Glass Dimensions | 200 × 50 mm |
| UV Blocking Efficiency | >95% attenuation of incident UV radiation by front protective window |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-7 |
| Instrument Type | Portable (Handheld) |
| Wavelength Options | Dual-band (254 nm & 365 nm) |
| UV Filter Size | 50 × 200 mm |
| UV Lamp Power | 6 W |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Compliance | CE-marked for laboratory use under IEC 61010-1 safety standard |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-8 |
| Instrument Type | Darkroom-style |
| Wavelengths | 254 nm (UVC), 302 nm (UVB), 365 nm (UVA), and 400–700 nm (Visible) |
| UV Filter Glass Dimensions | 200 × 80 mm |
| UV Lamps | Four 6 W low-pressure mercury lamps |
| Visible Lamp | One 4 W white-light lamp |
| Power Supply | 220 V AC, 50 Hz |
| Weight | 6 kg |
| Compliance | CE-marked for laboratory use |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZF1-1 |
| Instrument Type | Darkroom-style |
| Wavelength Options | 254 nm, 302 nm, 365 nm, and White Light |
| UV Filter Area | 20 × 15 cm |
| UV Lamps | 60 W total (dual-band reflective configuration) |
| Input Voltage | 220 V AC, 50 Hz |
| Compliance | CE-marked for laboratory use, conforms to IEC 61010-1 safety standards |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ANESTHESIA |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mask Series (Canine, Feline, Rodent/Avian) |
| Pricing | Available Upon Request |
| Diaphragm Opening Diameter | 25 mm / 38 mm / 44 mm / 50 mm (varies by size) |
| Port ID | 11.9 mm / 15 mm |
| Material | Polycarbonate (mask body), Medical-Grade Rubber (diaphragm) |
| Sizes | Small, Medium, Large, Multi-Pack Kits |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-0001 |
| Gas Agent | Isoflurane |
| Carrier Gas | Oxygen |
| O₂ Inlet Pressure | 50 PSI (fixed) |
| O₂ Flow Range | 0–4 LPM (mechanically limited) |
| Max Safety Flow | 50 LPM (safety-limited bypass) |
| Vaporizer Range | 0.5–5.0% Isoflurane |
| CO₂ Absorber Capacity | 3 lb (reusable, removable) |
| Application Weight Limit | ≤136 kg (300 lb) |
| Compatibility | Rebreathing & Non-rebreathing Circuits |
| Integrable With | Veterinary Ventilators |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-006 |
| Oxygen Inlet Pressure | 50 PSI (fixed) |
| Max Oxygen Flow | 50 LPM (safety-limited) |
| Adjustable O₂ Flow Range | 0–4 LPM |
| Isoflurane Vaporizer Range | 0.5–5.0% |
| CO₂ Absorber Capacity | 3 lb (1.36 kg) |
| Dimensions (L×W×H) | 40 × 35.5 × 85 cm |
| Compliance | ASTM F2739, ISO 80601-2-13, USP <1211>, GLP-ready design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTX 384L |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | BTX Electrofusion Electrodes |
| Voltage Range | 0–500 V DC (Microslides), 0–480 V DC / 0–16 V AC (Meander & Flat Chambers) |
| Pulse Duration | 1 µs – 99 ms |
| Pulse Count | 1–99 |
| Electrode Gaps | 0.2 mm (Meander), 0.5 / 1.0 / 3.2 / 10.0 mm (Microslides), 1.0 mm (Flat Chamber) |
| Field Uniformity | Non-uniform (Microslides, Meander, Flat in fusion mode), Uniform (Flat in electroporation mode) |
| Sample Volume Capacity | 20–2200 µL (Microslides), 5–20 µL (Meander), 500 µL (Flat Chamber) |
| Compatible Systems | ECM830, ECM2001 |
| Reusability | Yes (with mild cleaning) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model Variants | 450, 450-1, 453, 453-10 |
| Voltage Range | 0–500 VDC |
| Pulse Duration | 1 µs – 99 ms |
| Pulse Count | 1–99 |
| Electrode Gap Options | 0.5 mm, 1.0 mm, 3.2 mm, 10 mm |
| Sample Volume Capacity | 20 µL – 2.2 mL |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 20–80% |
| Altitude Limit | ≤2000 m |
| Insulation Category | CAT I |
| Pollution Degree | II |
| Autoclavable | No |
| Compatible Generators | ECM® 2001, ECM 630, 830, 395, 399, 600, T820 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTX Model 524 |
| Pricing | Upon Request |
| Electrode Type | Reusable bipolar tweezer-style electroporation electrode |
| Length | 11.5 cm |
| Adjustable Inter-electrode Gap | Up to 20 mm |
| Electrode Disk Diameter Options | 7 mm (Part #45-0118) or 10 mm (Part #45-0119) |
| Electrode Material | Stainless steel disk electrodes with integrated anode indicator |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BTX Specialized Electroporation Electrodes |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 2000 |
| Flow Range | 0.2–4 L/min (O₂) |
| Mounting | 5-Point Castor Base with MRI-Compatible Option Available |
| Compliance | FDA-Cleared Materials, ISO 13485–Aligned Manufacturing |
| Configuration Options | Single O₂, Dual O₂, O₂ + Air, O₂ + NO, MRI-Safe Variant |
| Standard Circuit | Jackson-Rees Non-Rebreathing (2 L bag, Cat. #72-3073) |
| CO₂ Absorption | Sealed Canister with Optimized Soda Lime Exposure Geometry |
| Surface Finish | Electrostatic Powder-Coated, Cleanroom-Compatible |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range | 0.2–4 L/min (O₂) |
| Vaporizer | Original 100 Series or TECH3 Isoflurane Vaporizer (≥250 mL, output accuracy ±0.5%) |
| CO₂ Absorbent Canister Capacity | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Circuit Type | Dual-path F-circuit with integrated Pop-off valve (2 cm H₂O constant negative pressure) |
| Construction | Anodized matte-finish aluminum chassis |
| Compliance | FDA-recognized materials (NASA-derived loop board), USP <1210> compatible design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model Range | CDS2000, CDS9000, Vaporstick Plus Desktop, Table Top Series |
| Flow Rate Range | 0.2–4 L/min (O₂), 0–1000 mL/min (auxiliary gases) |
| CO₂ Absorber Capacity | ≥900 mL (CDS9000) |
| Vaporizer Compatibility | ISO-standard 100-series isoflurane/sevoflurane vaporizers (e.g., Harvard 100 Series, Tech3/Tech4, Ohio) |
| Dimensions (CDS2000) | 133.35 cm H × 66.04 cm W (base diameter) |
| Dimensions (Desktop Models) | 30.48 cm W × 20.32 cm D × 38.1 cm H (Vaporstick Plus) |
| Regulatory Compliance | FDA-cleared materials, CE-marked, ISO 13485-manufactured, GLP-ready architecture |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range (O₂) | 0.2–4 L/min |
| Vaporizer | 100 Series Isoflurane Vaporizer (≥250 mL capacity, ±0.5% output accuracy) |
| CO₂ Absorbent Canister Volume | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Fresh Gas Outlet | Yes |
| Inhalation/Exhalation Ports (Closed-Circuit) | Yes |
| Pop-off Valve | Adjustable, provides continuous −2 cm H₂O baseline pressure for rebreathing bag |
| Oxygen Bypass Switch | Integrated |
| Construction | Anodized matte-finish aluminum chassis |
| Brand | Harvard Apparatus |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CMA Basic Microdialysis System |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | DHV1000 |
| Dimensions | 76.2 cm H × 40.6 cm W × 40.6 cm D |
| Weight | 20.4 kg |
| Power Supply | 100–220 V, 50/60 Hz |
| Compliance | MRI-compatible variant available |
| Included Accessories | 116.8 cm ventilator-to-bag hose (5.1 cm ID), 61 cm O₂ hose with DISS female connectors, power pack (P/N 32411B10), bellows assembly (P/N 32423C7), custom mounting bracket, descending bellows mechanism |