| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN70-4A |
| Instrument Type | Full-temperature microplate shaker |
| Timer Range | 0–99 h 59 min |
| Oscillation Speed | 300–1200 rpm |
| Orbit Diameter | 3 mm |
| Temperature Range | Ambient +5°C to 70°C |
| Plate Capacity | 4 standard microplates (96-well or 384-well) |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Stability | ≤ ±0.2°C |
| Heating Accuracy | < ±0.3°C at 37°C |
| Ramp Time | < 25 min (20°C → 70°C) |
| Drive Motor | Brushless DC motor |
| Power Consumption | 250 W |
| Dimensions (W×D×H) | 345 × 310 × 178 mm |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN80-6A |
| Temperature Range | 0–100 °C |
| Temperature Uniformity | ≤±0.5 °C @ 37 °C |
| Temperature Accuracy | ≤±0.5 °C @ 37 °C |
| Display Resolution | 0.1 °C |
| Speed Range | 200–1600 rpm |
| Orbit Diameter | 3 mm |
| Capacity | 6 deep-well plates (96-well or 24-well format compatible) |
| Timer Range | 1 min – 99 h 59 min |
| Heating Time | <5 min (25→60 °C), ≤20 min (25→100 °C) |
| Power Supply | AC 220 V, 50–60 Hz |
| Rated Power | 480 W |
| Dimensions | 481 × 346 × 228 mm |
| Weight | 15 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN92-II |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 650 W |
| Operating Frequency | 20–25 kHz |
| Temperature Range | −5 to 100 °C |
| Maximum Sample Volume | 650 mL |
| Number of Samples per Run | 1 |
| Probe Material | Titanium Alloy |
| Duty Cycle Adjustment | 1–99.9% |
| Automatic Frequency Tracking | Yes |
| Amplitude Stability Control | Yes |
| Integrated Temperature Monitoring & Protection | Yes |
| Brand | Hanuo |
|---|---|
| Model | HN92-IID |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 20–900 W (adjustable) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | Ambient to 90 °C |
| Maximum Sample Volume | 1000 mL |
| Probe Diameter | Φ6 mm or Φ10 mm (included) |
| Duty Cycle | 1–99.9% |
| Sample Capacity Range | 0.2–600 mL |
| Temperature Protection Threshold | ≤90 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Control System | Microprocessor-Based with Digital Interface |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN92-IIDL |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 900 W (adjustable, 20–900 W range) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | 0–90 °C |
| Sample Volume Capacity | 0.2–600 mL |
| Probe Diameter Options | Φ6 mm or Φ10 mm |
| Integrated Overtemperature Protection | Yes (triggers at ≥90 °C) |
| Display | LCD (upgraded large-screen interface) |
| Probe Material | Medical-grade titanium alloy (Ti-6Al-4V) |
| Amplitude Stability | Auto-compensated under variable load conditions |
| Duty Cycle & Pulse Mode | Programmable on/off intervals |
| Acoustic Enclosure | Sound-dampened chamber with certified acoustic insulation (≥35 dB attenuation at 25 kHz) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN96-II |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 10–150 W |
| Operating Frequency | 20–25 kHz |
| Standard Probe | Φ6 mm |
| Sample Volume Capacity | 0.2–150 mL |
| Optional Probes | Φ2, Φ3, Φ8, Φ10 mm |
| Duty Cycle Range | 1–99.9% |
| Temperature Control Range | −5 to 100 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Control System | Microprocessor-based, continuous power adjustment |
| Safety Features | Real-time temperature monitoring with thermal cutoff, automatic frequency tracking, fault diagnostics |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN96-II |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 10–150 W |
| Operating Frequency | 20–25 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume Capacity | 0.2–150 mL |
| Number of Samples per Run | 1 |
| Standard Probe Diameter | Φ6 mm |
| Optional Probe Diameters | Φ2, Φ3, Φ8, Φ10 mm |
| Duty Cycle | 1–99.9% |
| Integrated Temperature Monitoring & Control | Yes |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Microprocessor-Controlled Operation | Yes |
| Adjustable Amplitude with Load Compensation | Yes |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN98-I |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume | (0.1–2) mL × 4 |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220/110 V, 50/60 Hz |
| Cooling Interface | Yes (external chiller compatible) |
| Sample Throughput | Up to 4 tubes per cycle |
| Display | LCD |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN98-IB |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Tube | 0.2 / 0.5 / 1.5 / 2.0 mL |
| Sample Capacity | 4 or 6 tubes simultaneously |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Display | Large LCD (touchscreen optional) |
| Cooling Interface | Optional water-circulation port for external chiller |
| Communication | RS232/RS485 optional |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Tube | 0.2 / 1.5 / 2.0 mL |
| Sample Capacity | 4 or 6 tubes simultaneously |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN98-IIB |
| Instrument Type | Cup-Horn Ultrasonic Cell Disruptor |
| Ultrasonic Power | 2500 W |
| Operating Frequency | 19 kHz |
| Sample Volume per Tube | 0.1–2 mL |
| Maximum Simultaneous Samples | 8 |
| Temperature Control | Ambient (with optional external chiller interface) |
| Duty Cycle Range | 1–99.9% |
| Input Voltage | 220 V / 50 Hz (standard) |
| Compliance | CE-marked design principles |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN98-IIB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Frequency | 20 kHz |
| Maximum Ultrasonic Power | 1200 W |
| Temperature Range | 0–99 °C |
| Sample Volume per Tube | 0.1–2 mL |
| Number of Simultaneous Samples | 4 or 6 |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Cooling Interface | Yes (for external chiller connection) |
| Display | Large LCD |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IIID |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1200 W |
| Operating Frequency Range | 19–23 kHz |
| Temperature Control Range | 0–90 °C |
| Maximum Sample Volume | 1000 mL |
| Sample Throughput | Single-sample batch processing |
| Transducer Material | Titanium alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic load-compensated adjustment |
| Display | Backlit LCD with real-time parameter monitoring |
| Data Storage | 50 programmable protocols |
| Safety Features | Overtemperature alarm, frequency tracking failure detection, acoustic enclosure with certified sound attenuation (>35 dB reduction at 1 MHz) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN98-IIIDL |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume Capacity | 1000 mL |
| Sample Throughput | Single sample per cycle |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN99-IIDL |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1800 W |
| Operating Frequency | 19–23 kHz |
| Temperature Range | 0–90 °C |
| Sample Volume Capacity | 1500 mL |
| Number of Samples per Run | 1 |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HND-2000 |
| Instrument Type | Vortex Mixer |
| Timing Range | 1 min – 99 h 59 min |
| Oscillation Frequency | 500–2500 rpm |
| Oscillation Amplitude | 4 mm (orbital diameter) |
| Speed Accuracy | ±10 rpm (at 2500 rpm) |
| Capacity | 15 × 50 mL tubes |
| Max Load | 5 kg |
| Top Plate Dimensions | 311 × 184 mm |
| Overall Dimensions | 426 × 250 × 432 mm |
| Net Weight | 21.5 kg |
| Power Supply | 100–230 V, 50/60 Hz |
| Power Consumption | 70 W |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNGS-10 |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 50–350 rpm |
| Orbit Diameter | 10 mm |
| Load Capacity | 2 kg |
| Operating Temperature | 4–45 °C |
| Dimensions (W×D×H) | 284 × 264 × 90 mm |
| Power Supply | AC 100–230 V |
| Platform Options | Interchangeable trays (conical flask rack, adjustable flask holder, universal platform) |
| Platform Quantity | Up to 4 (optional) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | HNGS-20 |
| Instrument Category | Orbital Shaker |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 50–350 rpm |
| Orbit Diameter | 10 mm / 20 mm / 30 mm (selectable via interchangeable platforms) |
| Number of Platforms | 4 |
| Operating Temperature Range | 4–45 °C |
| Input Voltage | AC 100–230 V |
| Load Capacity | 2 kg |
| Drive System | Brushless DC Motor |
| Display | LED (speed and timer) |
| Noise Level | <45 dB(A) |
| Compliance | CE-marked per EN 61000-6-3 & EN 61000-6-2 |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNGS-30 |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 50–250 rpm |
| Orbit Diameter | 30 mm |
| Load Capacity | 2 kg |
| Operating Temperature | 4–45 °C |
| Dimensions (W×D×H) | 284 × 264 × 90 mm |
| Input Voltage | AC 100–230 V |
| Power Supply Type | Universal voltage compatible |
| Motor Type | Brushless DC motor |
| Display | LED digital display for speed and timer |
| Platform Options | Interchangeable platforms (conical flask holder, adjustable flask rack, universal tray) |
| Platform Quantity | Up to 4 platforms (optional) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HNM4-150 |
| Price | USD 1,800 (excl. VAT & shipping) |
| Chamber Diameter | Ø150 mm (customizable) |
| Arm Count | 4 |
| Desiccant Towers | 4 × 500 mL |
| Glass Reservoirs | 4 × 25 mL, 4 × 50 mL, 4 × 100 mL |
| Flowmeters | 4 precision glass rotameters |
| Tubing | 4 × medical-grade silicone tubing |
| Activated Carbon | 1 kg (replenishable) |
| Optional | Oil-free silent vacuum pump |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTC-100 |
| Oscillation Frequency | 300–1800 rpm |
| Oscillation Amplitude | 3 mm (horizontal rotation) |
| Temperature Range | −5°C to 100°C |
| Temperature Uniformity | ≤ ±0.3°C |
| Temperature Stability | ±0.3°C |
| Temperature Display Resolution | 0.1°C |
| Heating Rate | <15 min (20°C → 100°C) |
| Cooling Rate | ≥7°C/min (100°C → 20°C), ≥1.2°C/min (ambient → ambient −20°C at 30°C ambient) |
| Timer Range | 0–99 h 59 min, multi-step programming |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 8.3 kg |
| Standard Plate | 1 interchangeable module included |
| Optional Modules | A–N series (including 96-well PCR plates, 0.2–50 mL tube formats, deep-well plates, and custom cavities) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTH-100 |
| Instrument Type | Heated Vortex Mixer / Thermo-Shaker |
| Timer Range | 0–100 h |
| Oscillation Frequency | 300–2000 rpm |
| Oscillation Amplitude | 3 mm (horizontal orbital) |
| Temperature Range | RT + 5°C to 100°C |
| Temperature Uniformity | ≤ ±0.3°C |
| Temperature Stability | ±0.3°C |
| Temperature Display Resolution | 0.1°C |
| Heating Rate | <15 min (20°C → 100°C) |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 6.8 kg |
| Sample Platform | Single interchangeable block platform |
| Drive Motor | Brushless DC motor |
| Safety Features | Over-temperature protection, auto-restart after power interruption, short-pulse mixing mode |
| Calibration Function | Built-in temperature calibration |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTH-100 |
| Instrument Type | Heated Orbital Shaker / Incubating Mixer |
| Timer Range | 0–99 h 59 min, multi-segment programming |
| Oscillation Speed | 300–2000 rpm |
| Oscillation Amplitude | 3 mm (horizontal orbital) |
| Temperature Range | Ambient +5 °C to 100 °C |
| Temperature Uniformity | ≤ ±0.3 °C |
| Temperature Stability | ±0.3 °C |
| Temperature Display Resolution | 0.1 °C |
| Heating Rate | <15 min (20 °C → 100 °C) |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 6.8 kg |
| Platform | Single interchangeable plate (multiple well-format compatible) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNUV-II |
| UV Wavelength | 254 nm (optional 312 nm / 365 nm lamps) |
| Exposure Time Range | 0–999.9 min |
| Exposure Energy Range | 0–99.99 J |
| UV Source | Five 10 W low-pressure mercury lamps |
| Power Consumption | 60 W |
| Chamber Material | Stainless steel |
| Display | Touch-enabled Chinese LCD interface |
| Memory | Non-volatile storage for up to 9 user-defined time/energy protocols |
| Operating Environment | 5–35 °C, ≤80% RH, 220 V AC ±20%, 50 Hz |
| Compliance | Designed for routine molecular biology workflows under GLP-aligned lab practices |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNUV-II |
| Instrument Type | Darkroom-style UV Crosslinker |
| UV Wavelength | 254 nm |
| UV Lamp Configuration | Five 10 W low-pressure mercury lamps (total nominal output 50 W) |
| Exposure Time Range | 0.1–999.9 min (0.1 min resolution) |
| Exposure Energy Settings | 9 programmable and persistent energy presets |
| Exposure Time Settings | 9 programmable and persistent time presets |
| Display | Monochrome LCD with Chinese interface |
| Control Interface | Touch-sensitive keypad |
| UV Shielding View Window | Yes |
| Chamber Material | Stainless steel interior |
| Chamber Dimensions (L×W×H) | 340 × 260 × 150 mm |
| External Dimensions (L×W×H) | 360 × 340 × 310 mm |
| Power Supply | 220 V AC, 50 Hz |
| Compliance | Designed for laboratory use in nucleic acid immobilization, UV sterilization, and photochemical crosslinking applications per standard molecular biology workflows |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNX-1500 |
| Type | Orbital Microplate Shaker |
| Timing Range | 0–99 h 59 min or Continuous Mode |
| Speed Range | 300–1500 rpm (300–1000 rpm under full load) |
| Orbit Diameter | 3 mm |
| Platform Capacity | 4 standard microplates (96-well format) |
| Dimensions (W×D×H) | 284 × 264 × 121 mm |
| Weight | 6 kg |
| Drive System | Brushless DC Motor |
| Display | LED Digital Display |
| Alarm | Audible End-of-Timer Alert |
| Compliance | CE-marked for laboratory use in EU |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNX-1500 |
| Instrument Type | Microplate Orbital Shaker |
| Timer Range | 99 h 59 min |
| Oscillation Frequency | 300–1500 rpm (standard range: 300–1000 rpm under full load) |
| Oscillation Amplitude | 3 mm (orbital, horizontal rotation) |
| Capacity | 4 standard microplates (96-well or 384-well) |
| Dimensions (W×D×H) | 284 × 264 × 121 mm |
| Weight | 6 kg |
| Drive System | Brushless DC motor |
| Display | LED digital display |
| Alarm | Audible end-of-program alert |
| Power Supply | AC 220 V, 50 Hz |
| Certifications | CE-compliant design |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HNX-1500 |
| Price | USD 760 (est.) |
| Instrument Type | Microplate Shaker |
| Timer Range | 0–99 h 59 min |
| Oscillation Speed | 300–1500 rpm |
| Amplitude | 3 mm (orbital) |
| Temperature Control | None |
| Capacity | 4 standard microplates (e.g., 96-well, 384-well, 24-well, 48-well plates) |
| Dimensions | 284 × 264 × 121 mm |
| Weight | 6 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNX-2500P |
| Instrument Type | Benchtop Microplate Centrifuge |
| Function | General-purpose microplate centrifugation |
| Max RCF | 797 × g |
| Max Speed | 2500 rpm |
| Capacity | 2 standard microplates (96-well) or deep-well plates |
| Speed Range | 500–2500 rpm |
| RCF Range | 32–797 × g |
| Timer Range | 1–30 min |
| Noise Level | ≤55 dB(A) |
| Multi-step Programming | up to 5 segments |
| Cycle Repetition | up to 99 cycles |
| Auto Re-start After Power Failure | Yes |
| Imbalance Detection | Real-time dynamic monitoring with audible/visual alarm |
| Safety Features | Electronic lid lock, overspeed protection, self-diagnostic system |
| Motor | Brushless DC motor |
| Power Input | AC 220 V, 50–60 Hz |
| Max Power Consumption | 150 W |
| Dimensions (W×D×H) | 463 × 340 × 248 mm |
| Weight | 16 kg |
| Operating Environment | 0–35 °C, ≤70% RH |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HNX-2500P |
| Instrument Type | Benchtop Microplate Centrifuge |
| Function | Standard Microplate Centrifugation |
| Maximum RCF | 797 × g |
| Maximum Speed | 2500 rpm |
| Sample Capacity | 2 × 96-well PCR plates (or deep-well plates) |
| Operating Noise | ≤55 dB(A) |
| Speed Range | 500–2500 rpm |
| RCF Range | 32–797 × g |
| Timer Range | 1–30 min |
| Multi-step Programming | Up to 5 segments |
| Cycle Repetition | Up to 99 cycles |
| Auto Restart After Power Failure | Yes |
| Imbalance Detection | Real-time electronic monitoring with audible/visual alarm |
| Drive System | Brushless DC motor |
| Power Input | AC 220 V, 50–60 Hz |
| Max. Power Consumption | 150 W |
| Dimensions (W×D×H) | 463 × 340 × 248 mm |
| Weight | 16 kg |
| Ambient Operating Temperature | 0–35 °C |
| Relative Humidity | ≤70 % RH |