Moisture Analyzer
Filter
Showing 511–540 of 671 results
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SADP-D |
| Type | Portable Dew Point Meter |
| Measurement Principle | Aluminum Oxide Capacitive Sensor |
| Dew Point Range | –110 °C to +20 °C (configurable sub-ranges) |
| Accuracy | ±2 °C DP (traceable to NPL/NIST) |
| Repeatability | ±0.2 °C DP |
| Operating Temperature | –10 °C to +60 °C |
| Storage Temperature | –40 °C to +80 °C |
| Max Operating Pressure | 30 kPa(g) |
| Sample Flow Rate | 2–10 L/min (recommended: 2–5 L/min) |
| Response Time (dry → wet) | <20 s (–110 °C → –20 °C) |
| Response Time (wet → dry) | <120 s (–10 °C → –60 °C) |
| Display | 126 × 64 pixel backlit LCD |
| Power | Rechargeable Li-ion battery (250 h continuous operation, 6 h recharge) |
| Output Options | RS485 serial, USB, 4–20 mA analog (optional) |
| Calibration | User-accessible 2-point auto-calibration |
| Pressure Dew Point Calculation | Built-in, supports multiple pressure units |
| Data Logging | Real-time storage (optional) |
| Gas Path | Dual stainless-steel inlet/outlet ports (6 mm Swagelok + PTFE tubing) |
| Maintenance | Field-replaceable sensor and molecular sieve cartridge |
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SADP-U-P |
| Type | Portable Dew Point Meter |
| Measurement Principle | Aluminum Oxide Capacitive Sensor |
| Operating Temperature Range | −10 °C to +60 °C |
| Storage Temperature Range | −40 °C to +80 °C |
| Dew Point Range Options | −110 °C to +20 °C (configurable by sensor variant) |
| Accuracy | ±2 °C DP (traceable to NPL and NIST) |
| Repeatability | ±0.2 °C DP |
| Response Time (dry → wet) | <20 s (−110 °C to −20 °C) |
| Response Time (wet → dry) | <120 s (−10 °C to −60 °C) |
| Sample Flow Rate | 2–5 L/min (max 10 L/min) |
| Operating Pressure | ≤30 kPa(g) |
| Relative Humidity Limit | 95% RH (non-condensing) |
| Power Supply | Rechargeable Li-ion battery (250 h continuous operation, 6 h charge time) |
| Display | 126 × 64 pixel backlit LCD |
| Communication Interfaces | RS485, USB (optional), 4–20 mA analog output (optional) |
| Calibration | Two-point user-initiated auto-calibration |
| Pressure Dew Point Calculation | Built-in, supports multiple gauge pressure units |
| Gas Path | Dual stainless-steel inlet/outlet ports (6 mm Swagelok + PTFE tubing) |
| Sensor Lifetime | 5–10 years (gas-dependent) |
| Maintenance | User-replaceable sensor and molecular sieve cartridge |
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SADP.G |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Aluminum Oxide Capacitive Sensor |
| Operating Temperature Range | Up to 50 °C |
| Accuracy | ±2 °C |
| Repeatability | ±0.5 °C |
| Dew Point Range (Grey Dot) | −80 °C to 0 °C DP |
| Moisture Range (Grey Dot) | 0–6000 ppmv |
| Auto-Calibration | Ambient Air (1 min) |
| Intrinsic Safety | Certified |
| Power Supply | Alkaline Battery |
| Compliance | ISO 9002 |
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SDA-P |
| Type | Online Dew Point Meter |
| Principle | Chilled Mirror (Electrochemical Sensor Variant) |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±3 °C |
| Repeatability | ±3 °C |
| Measuring Range | -100 °C to 0 °C |
| Display | 3½-digit backlit LCD |
| Output | 4–20 mA analog signal, dual relay alarms (240 V AC @ 3 A) |
| Power Supply | 220 V AC, 50 Hz |
| Installation | Panel mount (cutout: 135 mm × 66 mm × 175 mm depth) |
| Sample Pressure | 1–30 psi (up to 200 bar sensor-rated) |
| Sample Flow Rate | 1–5 L/min (recommended: 1 L/min) |
| Gas Connection | 1/4" or 1/8" compression fittings |
| Intrinsic Safety | Sensor certified intrinsically safe |
| Calibration | Automatic 1-minute ambient air zero calibration |
| Compliance | ISO 9002 quality management system |
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SuperDew3 |
| Type | Online Dew Point Meter |
| Measurement Principle | Capacitive Polymer Sensor |
| Operating Temperature Range | −10 °C to +50 °C |
| Accuracy | ±2 °C (at 23 °C ambient, typical for calibrated sensor in dry gas) |
| Repeatability | ±0.5 °C |
| Display Resolution | 0.1 °C |
| Output Signal | 4–20 mA (isolated, HART-compatible), 0–1 V optional |
| Alarm Outputs | Two SPDT relays (240 V AC, 3 A) |
| Power Supply | 220 V AC, 50 Hz |
| Panel Cutout | 135 mm × 66 mm × 175 mm (D) |
| Enclosure Rating | IP65 (front panel), NEMA 4X equivalent |
| Sensor Cable Length | Up to 1000 m (with shielded twisted-pair cable) |
| Sensor Pressure Rating | Up to 200 bar (burst), operational range 1–30 psi (0.07–2.1 bar) |
| Sample Flow Rate | 1–5 L/min (recommended: 1 L/min) |
| Connection | 1/4″ or 1/8″ Swagelok®-type compression fittings |
| Intrinsic Safety | Ex ia IIC T4 Ga certified (sensor head only) |
| Calibration | Automatic 1-minute ambient air self-calibration routine |
| Optional Ranges | −110 °C to −20 °C (Silver), −100 °C to 0 °C (Purple), −80 °C to 0 °C (Grey), −80 °C to −20 °C (Red), −60 °C to 0 °C (Yellow) |
| Compliance | ISO 9001:2015 certified manufacturing |
| Environmental Certification | Meets EN 61000-6-2 (EMC immunity) and EN 61000-6-3 (EMC emission) standards |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MOC-120H |
| Price Range | USD 1,400 – 4,200 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | MOC-120H |
| Measurement Principle | Infrared Heating + Gravimetric Loss-on-Drying |
| Weighing Range | 120 g |
| Minimum Readability | 0.001 g |
| Moisture Content Range | 0.01–100.00% |
| Moisture Resolution | 0.01% |
| Sample Pan Diameter | 130 mm |
| Heating Source | Medium-Wave Quartz Infrared Heater |
| Temperature Setting Range | 30–180 °C (1 °C increments) |
| Heater Lifetime | 20,000–30,000 hours |
| Power Supply | AC 100–120 V / 220–240 V, max. 640 W |
| Dimensions (W×D×H) | 220 × 415 × 190 mm |
| Weight | 4.5 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Interface | RS-232C (direct Excel data export) |
| Predefined Modes | 10 |
| Stop Criteria | Auto-stop, Time-stop |
| Drying Profiles | Standard, Rapid, Slow, Stepwise, Predictive (Comparative) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | MOC120H |
| Measurement Principle | Gravimetric Loss-on-Drying (Infrared Heating) |
| Sample Capacity | 0.5–120 g |
| Moisture Resolution | 0.01% or 0.1% (selectable) |
| Mass Resolution | 0.001 g |
| Moisture Range | 0–100% (w/w), 0–500% (dry basis) |
| Repeatability | ±0.02% (≥10 g sample) |
| Temperature Range | 30–180 °C (1 °C increments) |
| Heating Source | Medium-Wave Infrared Lamp (625 W max) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions | 220 × 415 × 190 mm (W×D×H) |
| Weight | 4.5 kg |
| Data Storage | 100 measurement records |
| Method Storage | 10 user-defined protocols |
| Interface | RS-232C, Windows Direct Pass-through |
| Operating Environment | 5–40 °C, ≤85% RH |
| Sample Pan | Stainless Steel (Ø130 mm × 13 mm depth) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | MOC63U |
| Maximum Sample Capacity | 60 g |
| Minimum Sample Weight | 0.02 g |
| Minimum Display Resolution | 0.001 g / 0.01% or 0.1% (selectable) |
| Repeatability | ±0.15% (2 g sample), ±0.05% (5 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Heating Power | 400 W |
| Temperature Setting Range | 50–200 °C (1 °C increments) |
| Display | Backlit LCD |
| Pan Diameter | 95 mm |
| Dimensions (W × D × H) | 202 × 336 × 157 mm |
| Weight | 4 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Measurement Modes | Standard, Rapid Dry, Slow Dry, Step Dry |
| Measurement Duration | 1–120 min (extendable up to 12 h) |
| Interfaces | RS-232C (9-pin), DATA I/O, USB |
| Predefined Method Storage | 10 methods |
| Data Storage Capacity | 100 results |
| Optional Accessories | Temperature calibration kit |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Designation | ASTM-compliant GC-BID Configuration |
| Pricing | Available upon Request |
| Brand | Shimadzu |
|---|---|
| Model | Unibloc MOC63U |
| Heating Source | Halogen Lamp |
| Temperature Range | 50–200 °C |
| Minimum Sample Weight | 0.001 g |
| Display | Backlit LCD |
| Interfaces | RS-232C, USB, DATA I/O |
| Data Export | Direct to Microsoft Excel via Windows Pass-Through Window |
| Measurement Modes | Auto-Stop, Time-Stop, Standard/Fast/Slow/Step Drying |
| Dimensions (L) | 202 mm |
| Brand | ShinYEI |
|---|---|
| Origin | Japan |
| Model | mini CRDS-H2O |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Range | 12 ppbv to 20 ppmv (equivalent to -100 °C to +55 °C dew point) |
| Accuracy | ±4% of reading or 12 ppbv LOD |
| Response Time | ~60 s (90% from 50 to 1000 ppbv) |
| Operating Temperature | 10 °C to 40 °C |
| Sample Gas Flow Rate | <2 L/min |
| Sample Gas Temperature | 5 °C to 60 °C |
| Sample Gas Pressure | 86–106 kPaA |
| Gas Compatibility | Air, N₂, O₂, Ar, CO₂ |
| Interface | RS-232C, analog output (optional) |
| Power Supply | AC adapter (100–240 VAC, 50/60 Hz, max 1.4 A) |
| Enclosure Rating | IP67 |
| Dimensions (Sensor Unit) | 150 × 300 × 165 mm |
| Dimensions (Display/Control Unit) | 150 × 80 × 200 mm |
| Weight (Sensor Unit) | ~5 kg |
| Weight (Display/Control Unit) | ~1.7 kg |
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | AGS60 250C PRO, AGS120 250C PRO |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g / 120 g |
| Tare Range | –60 g / –120 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Linearity | ±0.002 g |
| Accuracy Class | II |
| Resolution | 0.01% moisture |
| Moisture Repeatability | ±0.3% (2 g sample), ±0.06% (5 g sample) |
| Interface | USB, RS232C, PS2 |
| Max Drying Temperature | 250 °C |
| Drying Time Range | 1–180 s per step, up to 10 hr total |
| Drying Power | 250 W |
| Preheat Time | ~30 s |
| Pan Diameter | 90 mm |
| Chamber Dimensions | 108 × 20 mm |
| External Dimensions | 215 × 345 × 200 mm |
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | ATS60, ATS120 |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g / 120 g |
| Readability | 0.001 g |
| Linearity | ±0.002 g |
| Accuracy Class | II |
| Resolution | 0.01% |
| Moisture Measurement Accuracy | ±0.1% (2 g sample), ±0.04% (5 g sample), 1% (0.02–0.5 g sample) |
| Drying Temperature Range | Up to 160 °C |
| Drying Time Range | 1–600 s (10 hr max) |
| Drying Power | 200 W |
| Preheat Time | ~60 s |
| Pan Diameter | 90 mm |
| Drying Chamber Dimensions | 108 × 20 mm |
| External Dimensions | 185 × 290 × 170 mm |
| Net Weight | 6.8 kg |
| Interfaces | USB, RS232C, PS2 |
| Brand | SOTAX |
|---|---|
| Model | CE 7smart |
| Apparatus Type | USP <724> Apparatus 4 (Flow-Through Cell) |
| Compliance | USP <711>, <1088>, Ph. Eur. 2.9.3, 2.9.42, 2.9.43, JP Dissolution Test Method 3 |
| Temperature Control Range | Ambient – 45 °C (±0.2 °C) |
| Flow Rate Range | 1.5–35 mL/min (with CP 7-35 piston pump) |
| Cell Capacity | 6 positions |
| Bath Volume | 8 L |
| Dimensions (H×D×W) | 470 × 600 × 580 mm |
| Weight | 36 kg |
| Software | WinSOTAX (21 CFR Part 11 compliant, client-server architecture supported) |
| Sample Handling | Online UV/Vis/UV-FO coupling or offline fraction collection for HPLC analysis |
| Brand | Southland Sensing |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-P |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | −20 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual range switching) |
| Display | Touchscreen with optional Chinese language interface |
| Output Signals | 4–20 mA (configurable), High/Low alarm relay outputs |
| Power Supply | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Weight | ~6 kg |
| Intrinsic Safety | Integrated Zener barrier compliant with IEC/EN 60079-11 for hazardous area use |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | InfraCal 2 ATR-SP |
| Price | Upon Request |
| Detection Limit (Water) | 0.3 ppm |
| Detection Limit (Soil) | 3 ppm |
| Compliance | EPA 1664, EPA 413.2, EPA 418.1, ASTM D7066, ISO 9377-2 |
| Solvents | Hexane, Pentane, Cyclohexane, Vertrel MCA |
| Measurement Principle | Fixed-Filter Infrared Absorption with Horizontal Attenuated Total Reflectance (HATR) |
| Analysis Time | <15 minutes |
| Sample Matrix | Water, Soil, Drilling Mud, Drill Cuttings, Wastewater (FOG), Sludge |
| Operating Environment | Marine-grade corrosion-resistant housing, rated for continuous offshore deployment >10 years |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPS Series |
| Pricing | Available Upon Request |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SF-2 |
| Price | USD 1,950 (approx.) |
| Brand | Stork |
|---|---|
| Origin | Poland |
| Model | DEWCom |
| Product Type | Online Dew Point Transmitter |
| Measurement Principle | Dual-ceramic nanofilm capacitive sensor |
| Operating Temperature | -40 °C to +60 °C |
| Accuracy | ±2 °C dew point |
| Repeatability | ±0.5 °C dew point |
| Dew Point Range | -100 °C to +20 °C dew point |
| Response Time (T95) | ~1 min (dry-to-wet) |
| Output Signal | 4–20 mA, 2-wire |
| Supply Voltage | 8–36 V DC |
| Load Resistance | ≤660 Ω @ 24 V DC |
| Power Consumption | ≤20 mA |
| Pressure Rating | up to 40 MPa |
| Flow Rate | 0.2–5 L/min (in standard flow cell) |
| Temperature Compensation | Full-range automatic compensation |
| Enclosure Rating | IP65 |
| Housing Material | Stainless steel |
| Filter | 20 µm sintered stainless steel |
| Sensor Interchangeability | Fully plug-and-play, no field recalibration required |
| Fault Signals | 23 mA or 3.5 mA (configurable) |
| <range | 4 mA |
| >range | 20 mA |
| Dimensions | Ø30 mm × 114 mm |
| Weight | 170 g |
| Brand | Stork |
|---|---|
| Origin | Poland |
| Model | DEWRanger UNO |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Capacitive Sensor with Dual-Ceramic Nanofilm Technology |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±2 °C |
| Dew Point Range | -100 °C to +20 °C |
| Flow Rate | Up to 3 L/min |
| Pressure Rating | Max 3 MPa (Swagelok fitting) |
| Display | 4-digit LED |
| Output | 4–20 mA analog |
| Power Supply | Rechargeable Li-ion battery & AC adapter |
| Enclosure | IP67-rated yellow polypropylene housing |
| Dimensions | 270 × 125 × 250 mm |
| Weight | ~3.0 kg |
| Filter | Sintered HDPE |
| Tubing | 6 mm PTFE |
| Fitting | 6 mm quick-connect |
| Brand | Stork |
|---|---|
| Origin | Poland |
| Model | DEWRay |
| Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror (Optical Beam-Splitting Reflectance) |
| Operating Temperature | 0 °C to +40 °C |
| Accuracy | ±0.2 °C |
| Dew Point Range | −30 °C to +90 °C (single-stage cooling), −40 °C to +90 °C (dual-stage cooling), −20 °C to +130 °C (high-temperature mode) |
| Resolution | 0.1 °C / 0.1 °F / 0.1 % RH |
| Flow Rate | 0.1–2 L/min |
| Response Speed | ~1 °C/s + stabilization time |
| Display | Blue LCD graphic display |
| Power | Rechargeable Li-ion battery |
| Enclosure | IP65-rated yellow polypropylene case |
| Dimensions | 270 mm × 124 mm × 248 mm |
| Weight | ~4 kg |
| Pressure Rating | 0–2.5 MPa standard |
| Output | 4–20 mA analog or RS-232 (RS-485 optional) |
| Data Storage | Internal non-volatile memory |
| Calibration | Traceable to international standards (NIST/PTB-equivalent) |
| Brand | Sundly |
|---|---|
| Model | SDTGA520 |
| Origin | Hunan, China |
| Application | Coal, coke, ores, solid biomass fuels |
| Standards Compliance | GB/T 212–2008, GB/T 211–2017, DL/T 2029–2019 |
| Sample Capacity | 20 positions |
| Temperature Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±2 °C |
| Max Power | 2 kW |
| Sample Mass (Analytical Moisture) | 0.9–1.1 g |
| Sample Mass (Total Moisture) | 10–12 g |
| Test Duration (Analytical Moisture) | 15–40 min |
| Test Duration (Total Moisture) | 25–60 min |
| Particle Size Compatibility | 0.2 mm, 3 mm, 6 mm |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 651 mm × 636 mm × 451 mm |
| Net Weight | ~67 kg |
| Heating Modes | Forced-air convection + infrared radiant heating |
| Optional Atmosphere | Nitrogen purge capability |
| Data Logging | Environmental temperature & humidity auto-captured and embedded in reports |
| Software Features | Batch configuration, custom test protocols, power-interruption recovery, GLP-compliant audit trail |
| Brand | Sundy |
|---|---|
| Model | SDTGA500 |
| Origin | Hunan, China |
| Instrument Type | Automatic Thermogravimetric Moisture Analyzer |
| Standards Compliance | GB/T 212–2008, GB/T 211–2017, DL/T 2029–2019 |
| Sample Capacity | 12 positions |
| Analytical Water Sample Mass | 0.9–1.1 g |
| Total Moisture Sample Mass | 10–12 g (user-definable range) |
| Test Duration | 15–40 min (analytical moisture), 25–60 min (total moisture) |
| Temperature Control Range | Ambient to 150 °C |
| Temperature Accuracy | ±2 °C |
| Max Power Consumption | 1.5 kW |
| Sample Particle Size Compatibility | ≤0.2 mm, 3 mm, 6 mm |
| Balance Resolution | 0.1 mg (imported high-precision weighing module) |
| Dimensions (W×D×H) | 450 mm × 480 mm × 450 mm |
| Net Weight | ~40 kg |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Nitrogen Purge Function | Yes, with optimized flow control |
| Safety Features | Auto-diagnostic, power-fail recovery, thermal self-protection |
| Data Output | Real-time mass tracking, GLP-compliant audit trail, CSV/PDF report export, LAN-enabled remote monitoring |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | ESH Series (ESH122 / ESH123 / ESH124) |
| Heating Source | 600 W Quartz Halogen Lamp |
| Weighing Range | 120 g |
| Readability | 5 mg / 1 mg / 0.1 mg |
| Moisture Readability | 0.01% / 0.01% / 0.001% |
| Repeatability | ±0.5% / ±0.25% / ±0.1% (at 2 g) |
| Display | 4.3″ TFT Touchscreen |
| Temperature Range | 40–180 °C |
| Heating Modes | Standard / Progressive / Step |
| Measurement Modes | Auto / Manual / Timer / Loss-on-Drying |
| Data Storage | 36 test records |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Max Power Consumption | 800 W |
| Operating Ambient | 5–40 °C |
| Sample Pan Diameter | Φ100 mm |
| Dimensions (W×D×H) | 380 × 200 × 210 mm |
| Net Weight | 5.8 kg |
| Gross Weight | 7.8 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | ESH31 |
| Price | USD 780 (FOB Shanghai) |
| Heating Method | Quartz Halogen Lamp |
| Weighing Range | 110 g |
| Readability | 10 mg |
| Display | High-Resolution LCD (Backlight Optional) |
| Sensor Type | Strain-Gauge Load Cell |
| Sample Pan Diameter | Φ90 mm |
| Net Weight | 5.8 kg |
| Dimensions (L×W×H) | 200 × 180 × 380 mm |
| Operating Temperature | 5–40 °C |
| Temperature Range | 40–199 °C (1 °C increments) |
| Moisture Range | 0.00–100.00 % |
| Moisture Readability | 0.01 % |
| Drying Range | 100.00–0.00 % |
| Drying Readability | 0.01 % |
| Timer Setting | 3–99 min |
| Data Storage | 15 test history entries |
| Calibration Standard | Class F2 Stainless Steel Weights |
| Heating Power | 450 W |
| Lamp Lifetime | ≥5000 h |
| Cooling System | Low-Noise Fan (<20 dB) + Multi-Channel Airflow |
| Interface | RS232 Serial Port |
| Housing Material | Die-Cast Aluminum + High-Temp Polymer (250 °C continuous rating) |
| Chamber | Dual-Layer 304 Stainless Steel, Mirror-Finished Interior |
| Viewing Window | Frosted Tempered Glass |
| Sample Height Clearance | 22 mm |
| Leveling | Precision Bubble Level + Adjustable Feet |
| Standard Accessories | 50 × Aluminum Sample Pans |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | DHS Series |
| Heating Method | Infrared |
| Max Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (DHS-16A), 50–200 °C (DHS-20A) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min steps) |
| Termination Modes | Auto (weight stability), Timed, Manual |
| Built-in Methods | 50 user-programmable protocols |
| Output Parameters | Initial mass (g), Residual mass (g), Moisture content (% w/w), Dry matter (%), Moisture loss (%), Regain (%), Wet basis moisture (%), Heating mode, Set temperature, Duration |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation templates available |
| Power Supply | 220 VAC (±15% / −10%), 50 Hz |
| Power Consumption | 400 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | LHS Series |
| Heating Method | Halogen Lamp |
| Maximum Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (LHS-16 models), 50–200 °C (LHS-20 models) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min increments) |
| Termination Modes | Automatic (weight change-based), Timed, Manual |
| Built-in Methods | 50 pre-programmed |
| Result Outputs | Initial mass (g), Residual mass (g), Moisture content (%), Dry matter (%), Moisture loss (%), Rehydration ratio, Wet basis moisture (%) |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation support |
| Power Supply | 220 VAC (−15% to +10%), 50 Hz |
| Power Consumption | 420 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Net Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | MaxTira20Q |
| Pricing | Upon Request |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | MaxTitra20V |
| Pricing | Upon Request |
| Titration Method | Volumetric Karl Fischer |
| Endpoint Detection | AC Polarization Potential Difference |
| Measurement Range | 0.1 mg – 500 mg H₂O (equivalent to 10 ppm – 100% w/w) |
| Minimum Dispensing Volume | 0.005 mL |
| Data Storage | 20 built-in methods & results |
| Display | 16-character × 2-line LCD with backlight |
| Interfaces | RS-232 for balance, printer, and PC |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 W |
| Dimensions | 310 W × 270 D × 310 H mm |
| Weight | ~6 kg |