Moisture Analyzer
Filter
Showing 541–570 of 676 results
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | LHS Series |
| Heating Method | Halogen Lamp |
| Maximum Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (LHS-16 models), 50–200 °C (LHS-20 models) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min increments) |
| Termination Modes | Automatic (weight change-based), Timed, Manual |
| Built-in Methods | 50 pre-programmed |
| Result Outputs | Initial mass (g), Residual mass (g), Moisture content (%), Dry matter (%), Moisture loss (%), Rehydration ratio, Wet basis moisture (%) |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation support |
| Power Supply | 220 VAC (−15% to +10%), 50 Hz |
| Power Consumption | 420 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Net Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | MaxTira20Q |
| Pricing | Upon Request |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | MaxTitra20V |
| Pricing | Upon Request |
| Titration Method | Volumetric Karl Fischer |
| Endpoint Detection | AC Polarization Potential Difference |
| Measurement Range | 0.1 mg – 500 mg H₂O (equivalent to 10 ppm – 100% w/w) |
| Minimum Dispensing Volume | 0.005 mL |
| Data Storage | 20 built-in methods & results |
| Display | 16-character × 2-line LCD with backlight |
| Interfaces | RS-232 for balance, printer, and PC |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 W |
| Dimensions | 310 W × 270 D × 310 H mm |
| Weight | ~6 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YLS-B Series |
| Price Range | USD 700 – 1,400 (FOB) |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g (YLS-B Plus) / 20 g (YLS-B Standard) |
| Readability | 1 mg (60 g model) / 2 mg (20 g model) |
| Moisture Resolution | 0.02–0.1% |
| Temperature Range | 50–160 °C (1 °C increments) |
| Heating Time | 0–99 min (1 min steps) |
| Display | Backlit dot-matrix LCD with dual blue/white background |
| Data Storage | 50 sample profiles |
| Interface | RS232C |
| Calibration | External weight calibration (20 g for YLS-B |
| Compliance | Supports IQ/OQ/PQ validation |
| Power Supply | 220 VAC (±15%/+10%), 50 Hz |
| Power Consumption | 300 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Recommended Ambient | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 458 × 278 × 246 mm |
| Net Weight | 5.5 kg |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 1100 |
| Sample Temperature Range | 5–60 °C |
| Ambient Temperature Range | 0–40 °C |
| Measurement Time | < 1 s |
| Repeatability | ±0.5% typical standard deviation (material-dependent) |
| Display | 3.5-inch backlit graphical LCD |
| Data Storage | EEPROM, up to 250 measurements |
| Memory Slots | 25 product-specific calibration profiles |
| Power Supply | NiMH rechargeable battery |
| Battery Life | ~5 h (median usage, fully charged) |
| Protection Rating | IP20 |
| Interface | USB |
| Software | TEWS Moisture View Lite © |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 1150 |
| Repeatability | ±0.5% typical standard deviation (material-dependent) |
| Measurement Time | <1 s |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Operating Sample Temperature Range | 5–60 °C (with optional Pt100 or IR temperature sensor and auto thermal stabilization compensation) |
| Ambient Temperature Range | 0–40 °C |
| Enclosure Rating | IP20 |
| Display | Backlit LCD graphic display (320 × 240 pixels), 5.7-inch diagonal |
| Internal Memory | EEPROM storage for up to 25 product profiles and 250 measurement records |
| Data Interface | USB (PC connectivity) |
| Analog Output | 0(4)–20 mA with current isolation |
| Software Support | TEWS Moisture View Lite © |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 3012 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Operating Temperature | 0–40 °C |
| Analog Input | Product Temperature |
| Analog Output | Measured Values |
| Digital I/O | Control & Status Signals |
| Communication Interfaces | RS-232/RS-485 Serial, Ethernet (10/100BASE-T), CAN 2.0A/B, LAN |
| Max Sampling Rate | 40,000 readings/s |
| Application Scope | In-line moisture & density measurement of fast-moving discrete or continuous materials (e.g., cigarettes, yarns, tablets, capsules, filter rods) |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 4260 / MW 4270 / MW 4200 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Power Consumption | 160 VA (MW 4260), 200 VA (MW 4270) |
| Operating Temperature | 0–45 °C |
| Display | 10.4" LED color touchscreen (MW 4270), 5" LCD (MW 4260), single-line LED (MW 4200) |
| Data Interfaces | 1× Ethernet, 1× analog input (0/4–20 mA), 3× analog outputs (0/4–20 mA), 8× passive digital outputs, 8× digital inputs |
| Measurement Rate | up to 3,500 readings per second |
| Internal Data Storage | 60,000 measurements |
| Enclosure Rating | IP55 (industrial duty), ATEX-certified variants available for gas/dust hazardous areas |
| Sensor-to-Display Distance | up to 8 m (MW 4200 optimized for remote mounting) |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 4300 / MW 4310 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Power Consumption | 60 VA |
| Operating Temperature | 0–45 °C |
| Data Interfaces | 2× RS-232 (COM + Service), 1× Ethernet, 3× USB, 1× Analog Input (0/4–20 mA for optional IR sensor), 1× Pt100 temperature sensor input, PS/2 mouse & keyboard + VGA display support |
| Measurement Time | Millisecond-scale |
| Internal Data Storage | 6,000 measurements |
| External Server Storage | Unlimited |
| Display | MW 4300 — integrated 10.4" (26.4 cm) LCD color touchscreen |
| Sample Volume Range | 1–2000 mL |
| Max. Sensor Units Supported | 2 (lab-grade microwave sensors) |
| Calibration Profiles | Up to 200 product-specific calibration curves |
| Software | Pre-installed TEWS Moisture View© |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Sensor Types | Tubular, Planar, Fork-Type, TipTop & Custom Configurations |
| Application Scope | Laboratory QC, In-Line Process Monitoring, Batch Sampling |
| Material Compatibility | Powders, Granules, Tablets, Sheets, Fibers, Pellets, Non-Adhesive Bulk Solids |
| Construction | Stainless Steel (AISI 316L) + High-Strength Alumina Ceramic |
| Interface | Analog 4–20 mA / Digital RS-485 / EtherNet/IP (compatible with TEWS MW-E Series Electronics, excluding MW-T) |
| Compliance | CE, RoHS, ATEX Zone 22 (optional), ISO/IEC 17025 traceable calibration support |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW3012 |
| Measurement Principle | Microwave Absorption Spectroscopy (2.45 GHz) |
| Moisture Range | 10 ppm – 20 wt% |
| Sampling Rate | Up to 40,000 measurements per second |
| Response Time | < 1 ms |
| Sample Types | Powders, granules, tablets, capsules, fibers, films, sheets, yarns, cigarettes |
| Output | Simultaneous moisture content (%) and bulk density (g/cm³) |
| Compliance | CE, RoHS, ISO/IEC 17025 compatible workflows |
| Interface | RS-485, Ethernet (TCP/IP), 4–20 mA analog output |
| Operating Temperature | 0–50 °C |
| Enclosure Rating | IP65 |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-WS3 |
| Titration Method | Manual & Automated Coulometric/Volumetric |
| Moisture Range | 0.01 µg – 100% (w/w) |
| Detection Limit | 0.01 µg H₂O |
| Accuracy | ±2 µg (for 5–1000 µg), ±0.2% (for >1 mg, excluding sampling error) |
| Repeatability | ≤2% RSD |
| Titration Resolution | 0.1 µL (volumetric) / ±0.1 µA (coulometric current resolution) |
| Electrolysis Rate | 2 min per titration |
| Stirring Speed | 10 adjustable levels |
| Zero-Balance Time | ≤1 min |
| Power Supply | 12 V DC / 3 A |
| Operating Environment | 5–40 °C, <85% RH |
| Dimensions | 235 × 270 × 130 mm |
| Weight | 2.0 kg |
| Data Storage Capacity | >200,000 records |
| Compliance | GB/T 7600, GB 6283, SH/T 0246, SH/T 0255, GB/T 11133, GB/T 7380, GB 10670, GB/T 606, GB/T 8350, GB/T 8351, GB/T 3776.1, GB/T 6023, GB/T 3727, GB/T 7376, GB/T 18619.1, GB/T 1600, GB/T 11146, GB/T 12717, GB/T 18826, Chinese Pharmacopoeia (ChP) General Chapter 0832 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tiger HALO 3 H₂O |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | 111 |
| Price | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Technologies Co., Ltd. |
| Model | TP-108 |
| Measurement Range | 0.0–100.0 µg/L |
| Display | 7.0-inch color TFT touchscreen (Chinese UI) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <4 min |
| Cycle Time | ~3 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temp. | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Ambient Temp. | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Light Source | Monochromatic cold LED |
| Valves | Imported high-precision solenoid valves |
| Calibration | Automated dual-point standard calibration on user-defined schedule |
| Data Storage | 30 days of historical data per channel |
| Outputs | Isolated analog current signals (0–20 mA / 4–20 mA / 0–10 mA, programmable) |
| Alarms | Per-channel independent alarms (flow loss, upper/lower limit) |
| Power | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×D×H) | 460 × 280 × 720 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP-108 |
| Pricing | Upon Request |
| Measurement Range | 0.0–100.0 µg/L |
| Display | 7.0-inch color LCD touchscreen (Chinese interface) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <4 min |
| Cycle Time | ~3 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Ambient Temperature | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Output Signal | Isolated DC current output (0–20 mA / 4–20 mA / 0–10 mA, user-configurable) |
| Alarm Outputs | Independent per-channel alarms (flow interruption, upper/lower limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 mm × 720 mm × 280 mm |
| Panel Cutout | 670 mm × 410 mm |
| Weight | 22 kg |
| Channel Configurability | 1–6 channels selectable |
| Light Source | Monochromatic cold LED |
| Calibration | Automated dual-point standard calibration at user-defined intervals |
| Data Storage | 30 days of historical measurement data |
| Compliance | Designed for continuous operation in industrial process environments per IEC 61000-6-2/6-4 EMC standards |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP-130 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP-340 |
| Measurement Principle | Conductivity-based concentration determination via molar conductivity correlation |
| Measuring Range (selectable) | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% FS |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Stability | ±1% FS / 4 h |
| Temperature Compensation | PT1000 sensor, 0–60 °C |
| Sample Temp. Range | 5–50 °C |
| Ambient Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Storage Temp. | −25–55 °C |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤5 W |
| Dimensions | 200 mm × 200 mm × 85 mm |
| Weight | 2.1 kg |
| Display | 5.0″ capacitive color touchscreen, Chinese UI |
| Data Storage | Cyclic memory with auto-overflow management |
| Electrode | Corrosion-resistant conductive cell (included) |
| Compliance | Designed for industrial process QC per ISO/IEC 17025-aligned laboratory practices |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 ppm to 100% (w/w) |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Control Precision | ±20% for 3 µg H₂O |
| Electrolysis Current | 0–400 mA |
| Maximum Electrolysis Rate | ≤2.4 mg H₂O/min |
| Operating Temperature | 20–30 °C |
| Relative Humidity Limit | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤30 W |
| Dimensions (W×D×H) | 320 × 240 × 200 mm |
| Net Weight | 5 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Principle | Coulometric Titration (Faraday’s Law) |
| Water Content Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±1% at 100 µg, ±0.5% above 100 µg (excluding sample introduction error) |
| Minimum Dispensing Increment | 0.1 µL |
| Electrolysis Current Range | 0–400 mA |
| Detection Current Resolution | ±0.1 µA |
| Built-in Data Storage | Yes |
| Display | Backlit LCD with Chinese interface |
| Printer | Thermal, 36-character, Chinese-capable |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <200 W |
| Dimensions (W×D×H) | 310 × 315 × 215 mm |
| Weight | 3.5 kg |
| Brand | TimePower |
|---|---|
| Model | TP1051 |
| Origin | Beijing, China |
| Manufacturer | TimePower (Producer) |
| Type | Laboratory & Field-Deployable Dew Point Analyzer |
| Measurement Principle | Chilled-Mirror–Calibrated Electrochemical Sensor (Vaisala CARBOCAP®-derived architecture) |
| Operating Temperature | −20 °C to +60 °C |
| Accuracy | ±2 °C dew point |
| Repeatability | ±0.5 °C dew point |
| Measurement Range | −100 °C to 0 °C dew point (frost point mode below 0 °C) |
| Response Time (T90) | < 60 s (dependent on gas flow and moisture level) |
| Resolution | 0.1 °C dew point |
| Gas Flow Rate | 0.5–1.5 L/min |
| Sample Temperature Range | −20 °C to +50 °C |
| Ambient Temperature (continuous operation) | 0 °C to 40 °C |
| Ambient Temperature (intermittent use) | −20 °C to +50 °C |
| Relative Humidity Range | 0–100 %RH |
| Maximum System Pressure | 0.6 MPa |
| Output Signal | 4–20 mA (max. load 800 Ω) |
| Power Supply | AC 220 V, 50 Hz |
| Probe Protection | Stainless steel sintered filter (ISO 4406 Class 17/14 compliant) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP106 |
| Price | Upon Request |
| Measurement Principle | Molybdenum Blue Photometric Method (Silicomolybdate Reduction with 1-Amino-2-Naphthol-4-Sulfonic Acid) |
| Measurement Range | 0.0–200.0 μg/L or 0.0–2000 μg/L (selectable) |
| Accuracy | ±2% FS |
| Repeatability | ≤±1% FS |
| Drift | <±1% FS/24 h |
| Response Time | <10 min |
| Cycle Time | ~10 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Light Source | Monochromatic Cold LED |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Channels | 1–6 Configurable |
| Environmental Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month per reagent (4 reagents total) |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (user-selectable) |
| Alarm Outputs | Independent per channel — flow interruption, upper/lower limit |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 mm × 720 mm × 280 mm |
| Panel Cutout | 670 mm × 410 mm |
| Weight | 22 kg |
| Compliance | Designed for continuous industrial water quality monitoring in regulated environments |
| Brand | TimePower |
|---|---|
| Model | TP106 |
| Origin | Beijing, China |
| Manufacturer | TimePower Instruments Co., Ltd. |
| Measurement Principle | Molybdenum Blue Photometric Method |
| Measurement Range | 0.0–200.0 μg/L or 0.0–2000 μg/L (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <10 min |
| Cycle Time | ~10 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Sample Particulate Limit | <5 µm, non-colloidal |
| Light Source | Monochromatic cold LED |
| Display | 7.0-inch color TFT touchscreen (Chinese UI) |
| Channels | 1–6 configurable |
| Reagent Consumption | ~3 L/month per reagent (4 reagents total) |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (programmable) |
| Alarm Outputs | Independent per channel — high/low limit, flow interruption |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460×720×280 mm |
| Panel Cutout | 670×410 mm |
| Weight | 22 kg |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP106 |
| Price | Upon Request |
| Measurement Principle | Molybdenum Blue Photometric Method |
| Measurement Range | 0.0–200.0 μg/L or 0.0–2000 μg/L (selectable) |
| Accuracy | ±2% FS |
| Repeatability | ≤±1% FS |
| Drift | <±1% FS/24 h |
| Response Time | <10 min |
| Cycle Time | ~10 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Light Source | Monochromatic Cold LED |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Channels | 1–6 selectable |
| Data Storage | 30 days local history |
| Environmental Operating Conditions | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460×720×280 mm |
| Panel Cutout | 670×410 mm |
| Weight | 22 kg |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (configurable) |
| Alarm Outputs | Independent per channel — high/low limit, flow interruption |
| Reagent Consumption | ~3 L/month per reagent (4 reagents total) |
| Valves | Imported High-Precision Electromagnetic Valves |
| Compliance | Designed for continuous industrial water quality monitoring in regulated environments |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP107 |
| Measurement Principle | Vanadomolybdophosphoric Yellow Photometric Method (Acidic Medium) |
| Display | 7.0-inch TFT Color Touchscreen (Chinese UI) |
| Range Options | 0.00–20.00 mg/L or 0.00–50.00 mg/L |
| Accuracy | ±2% FS |
| Repeatability | ≤±1% FS |
| Drift | ≤±1% FS/24 h |
| Response Time | < 4 min |
| Cycle Time | ~3 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temp. | 5–50 °C |
| Particulates | < 5 µm, non-colloidal |
| Ambient Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (configurable) |
| Alarm Outputs | Independent per channel (flow loss, high/low limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions | 460 × 280 × 720 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Channel Configurability | 1–6 channels selectable |
| Data Storage | 30 days of historical measurement records |
| Light Source | Monochromatic cold LED |
| Calibration | Automated dual-point standard calibration on user-defined schedule |
| Compliance | GB/T 6913–2008 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP107 |
| Price | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | TP107 |
| Pricing | Available Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP108 |
| Price | Upon Request |
| Measurement Principle | Colorimetric Analysis (p-Dimethylaminobenzaldehyde Reaction in Acidic Medium) |
| Measurement Range | 0.0–100.0 µg/L |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <4 min |
| Cycle Time | ~3 min per channel |
| Channels | 1–6 configurable |
| Light Source | Monochromatic Cold LED |
| Valve Actuation | Imported High-Precision Solenoid Valves |
| Calibration | Automated Dual-Point Standard Calibration (User-Defined Interval) |
| Data Storage | 30 days of historical data (timestamped, per channel) |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (programmable per channel) |
| Alarm Outputs | Independent per-channel alarms (flow loss, upper/lower limit) |
| Sample Flow Rate | 10–40 L/h |
| Sample Temp. | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Ambient Temp. | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 × 720 × 280 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP108 |
| Price | Upon Request |
| Measurement Range | 0.0–100.0 μg/L |
| Display | 7.0-inch color LCD touchscreen, Chinese interface |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <4 min |
| Cycle Time | ~3 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Sample Particulates | <5 µm, non-colloidal |
| Ambient Temperature | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Output Signals | Isolated analog current outputs (0–20 mA / 4–20 mA / 0–10 mA, user-selectable) |
| Alarm Outputs | Independent per-channel alarms (flow interruption, upper/lower limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 × 720 × 280 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Channel Configuration | 1–6 channels selectable |
| Light Source | Monochromatic cold LED source |
| Calibration | Automated dual-point standard calibration at user-defined intervals |
| Data Storage | 30 days of historical data (per channel) |
| Compliance | Designed for continuous operation in industrial process environments per IEC 61000-6-2/6-4 EMI immunity & emission standards |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP110 |
| Pricing | Upon Request |