Moisture Analyzer
Filter
Showing 451–480 of 676 results
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB23 |
| Capacity | 110 g |
| Readability | 0.01 g |
| Moisture Readability (≥10 g sample) | 0.1% |
| Repeatability (3 g sample) | 0.3% |
| Repeatability (10 g sample) | 0.2% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | Ø90 mm |
| Heating Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s increments), 60–90 min (1 min increments) |
| Endpoint Detection | Timed or Automatic |
| Display | Moisture %, Solid %, Weight, Time, Temperature |
| Interface | Bidirectional RS232 |
| Operating Ambient Temperature | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.15 kg |
| Heating Source | Infrared Halogen Lamp |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB23 |
| Heating Method | Infrared (MB23/MB25) / Halogen (MB35/MB45) |
| Moisture Range | 0.01–100% (MB35/MB45, standard mode) |
| Readability | 0.01 g (MB23/MB25), 0.001 g / 0.01% (MB35/MB45) |
| Repeatability | ±0.015% (10 g sample, MB45), ±0.05% (10 g sample, MB35), ±0.2% (3 g sample, MB23), ±0.05% (3 g sample, MB45) |
| Temperature Range | 50–160 °C (MB23/MB25), 50–200 °C (MB35/MB45), adjustable in 1 °C or 5 °C increments |
| Timer Range | 1–120 min (MB35/MB45: 10 s resolution up to 60 min |
| MB23/MB25 | 30 s up to 60 min) |
| Pan Diameter | 90 mm |
| Communication | Bidirectional RS232 |
| Compliance | GLP-compliant data logging and print output |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Heating Method | Infrared |
| Maximum Capacity | 110 g |
| Readability | 0.01 g |
| Moisture Readability (for >10 g sample) | 0.1% |
| Repeatability (SD) | 0.3% for 3 g sample, 0.2% for 10 g sample |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s steps), 60–90 min (1 min steps) |
| Endpoint Control | Timed & Automatic |
| Display | Backlit LCD showing moisture %, solids %, weight, time, temperature |
| Interface | Bidirectional RS232 |
| Operating Environment | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Sample Pan Handle | Standard |
| Heating Source | Infrared Lamp |
| Brand | OHAUS |
|---|---|
| Model | MB25 |
| Heating Source | Halogen Lamp |
| Capacity | 110 g / 99 g (max. weight / max. moisture loss) |
| Readability | 0.01 g / 0.005 g |
| Moisture Readability (>10 g sample) | 0.05% |
| Repeatability (3 g sample) | 0.2% |
| Repeatability (10 g sample) | 0.05% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Heating Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s steps), 60–90 min (1 min steps) |
| Endpoint Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight (g), Time (min:s), Temperature (°C) |
| Interface | Bidirectional RS232 |
| Operating Ambient | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.2 kg |
| Standard Features | Backlit LCD, Integrated Sample Pan Handle, Thermal-Isolation Weighing Sensor Architecture |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Model | MB25 |
| Capacity | 110 g / 99 g (max. sample + tare) |
| Readability | 0.01 g (≤10 g), 0.005 g (>10 g) |
| Moisture Readability | 0.05% (for samples >10 g) |
| Repeatability | 0.2% (3 g sample), 0.05% (10 g sample) |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Heating Source | Halogen lamp |
| Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s step), 60–90 min (1 min step) |
| End-point Modes | Timed, Automatic |
| Display | Backlit LCD showing moisture %, solids %, weight, time, temperature |
| Interface | Bidirectional RS232 |
| Operating Environment | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.2 kg |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MB25 |
| Price | USD 1,390 (FOB US Port) |
| Capacity | 110 g / 99 g |
| Readability | 0.01 g / 0.005 g |
| Moisture Readability (>10 g sample) | 0.05 % |
| Repeatability (3 g sample) | 0.2 % |
| Repeatability (10 g sample) | 0.05 % |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Heating Program | Standard |
| Operating Ambient Temperature | 10–30 °C |
| Communication Interface | Bidirectional RS232 |
| Endpoint Detection | Timer-based & Auto-termination |
| Heating Temperature Range | 50–160 °C (in 5 °C increments) |
| Display Parameters | Moisture %, Solid %, Mass (g), Time (min:s), Temperature (°C) |
| Drying Time Range | 1–60 min (30 s increments) |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.2 kg |
| Sample Pan Handle | Included |
| Heating Source | Halogen Lamp |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB25 |
| Capacity | 110 g / 99 g (moisture mode) |
| Readability | 0.01 g / 0.005 g |
| Moisture Readability (>10 g sample) | 0.05% |
| Repeatability (3 g sample) | 0.2% |
| Repeatability (10 g sample) | 0.05% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | Ø90 mm |
| Heating Source | Halogen lamp |
| Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s increments), 60–90 min (1 min increments) |
| End Point Modes | Timed, Automatic |
| Display | Backlit LCD showing moisture %, solids %, weight, time, temperature |
| Interface | Bidirectional RS232 |
| Operating Environment | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.2 kg |
| Sample Pan Handle | Standard |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB25ZH |
| Heating Source | Halogen Lamp |
| Capacity | 110 g / 99 g (max. sample weight) |
| Readability | 0.01 g / 0.005 g |
| Moisture Readability (>10 g sample) | 0.05% |
| Repeatability (3 g sample) | 0.2% |
| Repeatability (10 g sample) | 0.05% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s steps), 60–90 min (1 min steps) |
| End Point Detection | Timed & Automatic |
| Display | Backlit LCD showing moisture %, solids %, mass, time, temperature |
| Interface | Bidirectional RS232 |
| Operating Ambient | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Sample Pan Handle | Standard |
| Key | Brand: OHAUS |
|---|---|
| Origin | USA |
| Heating Source | Halogen Lamp |
| Max Capacity | 90 g |
| Readability | 1 mg / 0.01% moisture |
| Pan Diameter | 90 mm |
| Temperature Range | 50–160 °C |
| Display | Dual-line backlit LCD |
| Interface | RS232 |
| Dimensions (H×L×W) | 130 × 280 × 170 mm |
| Net Weight | 2.1 kg |
| Power Supply | AC adapter (included) |
| Auto-termination Modes | Fixed weight loss, time-based, manual |
| Measurement Units | % moisture, grams |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |
| Compliance | GLP-compliant data output |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB27ZH |
| Heating Method | Halogen Lamp |
| Capacity | 90 g |
| Readability | 1 mg / 0.01% |
| Pan Diameter | 90 mm |
| Part Number | 30128007 |
| Dimensions (W×D×H) | 17 × 14 × 28 cm |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | MB32 |
| Pricing | Upon Request |
| Heating Method | Infrared |
| Max Capacity | 90 g |
| Readability | 1 mg / 0.01% moisture |
| Pan Diameter | 90 mm |
| Heater Type | Carbon Fiber |
| Communication | USB Device |
| Moisture Range | 0.01% – 100% |
| Temperature Calibration Points | 100°C, 160°C |
| Weight Calibration | External (50 g) |
| Dimensions (L×H×W) | 352 mm × 210 mm × 138 mm |
| Display | 4" LCD, dual-line |
| Results Shown | Moisture Content, Residual Solids, Moisture Regain, Heating Temperature, Elapsed Time, Method ID, Sample Weight |
| Heating Modes | Standard, Rapid |
| Built-in Screen Protector | Yes |
| Database Capacity | 2 test methods |
| Net Weight | 4.3 kg |
| Operating Ambient | 10°C – 40°C |
| Repeatability | ±0.02% (10 g sample), ±0.15% (3 g sample) |
| Shutdown Options | Automatic, Timed, Manual |
| Temperature Range | 40°C – 180°C |
| Environmental Compliance | CE, RoHS compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MB35 |
| Price | USD 2,520 (approx.) |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MB35 |
| Price | USD 2,450 (FOB) |
| Capacity | 35 g |
| Readability | 0.001 g / 0.01% |
| Repeatability (SD) | ±0.18% (3 g sample), ±0.05% (10 g sample) |
| Moisture Range | 0.05–100% |
| Timer | 1–120 min (30-sec intervals ≤60 min |
| Heating Temperature Range | 50–160 °C (5 °C increments) |
| Operating Ambient Temperature | 10–40 °C |
| Display | Backlit LCD, 128 × 64 pixel matrix |
| Data Output | RS232 interface |
| Compliance | GLP-compliant print output |
| Pan Diameter | 9 cm |
| Dimensions (W × H × D) | 19 × 15.2 × 36 cm |
| Weight | Approx. 3.2 kg |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | MB62 |
| Pricing | Upon Request |
| Heating Method | Infrared |
| Max Capacity | 90 g |
| Readability | 1 mg / 0.01% moisture |
| Pan Diameter | 90 mm |
| Heater Type | Carbon Fiber |
| Communication | USB Device, RS232 |
| Moisture Range | 0.01% – 100% |
| Repeatability | 0.018% (10 g sample), 0.10% (3 g sample) |
| Temperature Range | 40 °C – 200 °C |
| Calibration | Temperature calibration at 100 °C and 160 °C |
| Dimensions (L×H×W) | 352 mm × 210 mm × 138 mm |
| Net Weight | 4.3 kg |
| Operating Ambient | 10 °C – 40 °C |
| Display | 5” LCD, dual-line |
| Data Storage | 100 results |
| Method Library | 20 pre-programmable methods |
| Heating Modes | Slow, Standard, Step, Fast |
| Result Outputs | Moisture content, Solid content, Moisture regain, Weight loss, Heating temperature, Elapsed time, Method ID, Sample ID |
| Status Indicator | Multi-color status LED |
| Auto Shutdown | Timer-based, Automatic, Manual |
| Screen Protection Cover | Included |
| Environmental Compliance | CE, RoHS compliant |
| Software Compatibility | OHAUS MoisturePro™ (optional PC software for data export and audit trail) |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | MB92 |
| Pricing | Upon Request |
| Heating Method | Infrared |
| Maximum Capacity | 90 g |
| Readability | 1 mg / 0.01% moisture |
| Pan Diameter | 90 mm |
| Heater Type | Carbon Fiber |
| Communication Interfaces | RS232, USB Device, USB Host |
| Moisture Range | 0.01% – 100% |
| Repeatability | 0.08% (3 g sample), 0.015% (10 g sample) |
| Temperature Range | 40 °C – 200 °C |
| Calibration | External weight calibration (50 g), temperature calibration at 100 °C and 160 °C |
| Display | 4.3" capacitive touchscreen |
| Dimensions (L×H×W) | 352 mm × 210 mm × 138 mm |
| Net Weight | 4.3 kg |
| Operating Ambient | 10 °C – 40 °C |
| Sample Naming | Name, ID, batch number |
| Heating Modes | Slow, Standard, Step, Fast |
| Result Storage | 200 records |
| Test Database | 20 methods |
| Shut-off Criteria | Timed, Auto, Manual, Custom |
| Status Indicator | Multi-color LED |
| Screen Protection | Included |
| Displayed Parameters | Moisture content, solids content, moisture regain, heating temperature, real-time heating curve, elapsed time, sample name, statistics, mass loss, current weight |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | V100 |
| Price Range | USD 2,800 – 7,000 (FOB Shanghai) |
| Titration Mode | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1 µg |
| Moisture Content Range | 100 ppm to 100% w/w |
| Accuracy | ±0.3% relative |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Titration Control Precision | 1 µg (equivalent to 0.001 mL at 1 mg/mL KF reagent concentration) |
| Brand | PERIC |
|---|---|
| Model | GNF-TR-DP |
| Sensor Principle | Ultra-Thin Aluminum Oxide Capacitive |
| Measurement Range | –100 °C to +20 °C (Td) |
| Accuracy | ±2 °C @ +20 °C to –60 °C Td |
| Repeatability | ±0.5 °C |
| Stability | ±1% F.S. / 7 days |
| Response Time (63% / 90%) | 5 s / 10 s (–60 °C → –20 °C Td) |
| Explosion Protection | Ex db IIC T6 Gb (ATEX-compliant) |
| Ingress Protection | IP66 |
| Power Supply | 24 V DC |
| Communication Interface | TTL-level Serial Port |
| Analog Output | 4–20 mA (hardware-ready, software-configurable) |
| Mechanical Interface | M20×1.5 thread (display unit) |
| Operating Ambient Temperature | –10 °C to +50 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Sample Pressure | Atmospheric ±10% (vented to ambient) |
| Sample Flow Rate | 3–5 L/min |
| Sensor Lifetime | >2 years (normal operation) |
| Instrument Lifetime | >5 years (normal operation) |
| Brand | Perten |
|---|---|
| Origin | Imported (Sweden) |
| Model | AM 5200 |
| Heating Method | Radiofrequency (150 MHz) |
| Measurement Principle | RF Dielectric Constant |
| Sample Volume | 700 mL |
| Analysis Time | ~10 s |
| Display | 5.7-inch color resistive touchscreen |
| Communication | USB port |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 115/230 V, 50/60 Hz |
| Dimensions (W×D×H) | 415 × 424 × 353 mm |
| Net Weight | 18.3 kg |
| Measured Parameters | Moisture content, bulk density, temperature |
| Sample Types | Cereals, oilseeds, pulses (soybeans, lentils), dry beans, seeds, and other agricultural commodities |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | DPT-500 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Capacitive Metal Oxide Thin-Film Sensor (Nanoporous Al₂O₃) |
| Operating Temperature | -20 °C to +60 °C |
| Accuracy | ±2 °C (dew point) |
| Repeatability | ±0.5 °C |
| Dew Point Range | -110 °C to +20 °C |
| Response Time | ≤3 min to 95% of step change (dry-to-wet) |
| Gas Flow Rate | >1 L/min |
| Temperature Sensor Range | -40 °C to +70 °C |
| Pressure Sensor Option | 0–150 PSIA (0–10 bar), ±1% FS |
| Display Units | °C(dp), °F(dp), ppmv, ppmw, µbar, g/m³, lb/1000 ft³ |
| Data Logging Capacity | >4000 records (dew point, temperature, pressure) |
| Power | Rechargeable Li-ion battery (USB or AC adapter charging) |
| Enclosure Rating | IP65 (body), IP67/IP68 (connector with cap) |
| ATEX Certification | Ex II 2 G |
| Housing Material | Impact-resistant polyamide 12 |
| Wetted Materials | 316L stainless steel, PTFE |
| Dimensions | 187 × 106 × 50 mm (L×W×H) |
| Weight | 0.8 kg |
| Brand | PhyMetrix |
|---|---|
| Model | DPT-600 |
| Type | Portable/Tabletop Dew Point Meter |
| Measurement Principle | Capacitive Nanoporous Metal Oxide Sensor |
| Dew Point Range | −110 °C to +20 °C |
| Accuracy | ±2 °C |
| Repeatability | ±0.8 °C |
| Response Time (95% step) | 3 min |
| Operating Temperature | −20 °C to +60 °C |
| Gas Flow Rate | >1 L/min |
| Temperature Sensor Range | −40 °C to +70 °C |
| Pressure Sensor Option | 0–150 PSIA (10 bar), ±1% FS |
| Enclosure Rating | IP67/IP68 |
| Dimensions | 199 × 162 × 84 mm (L×W×H) |
| Weight | 1.6 kg |
| Power | Rechargeable Li-ion battery or 100–240 VAC adapter via USB Mini-B |
| Data Logging Capacity | >4,000 records (dew point, temperature, pressure) |
| Display | Backlit graphical LCD with auto-scaling bar chart |
| Interface | USB Mini-B (sealed cap), optional 4–20 mA (HART), optional ATEX-certified intrinsically safe version |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | DPT-600plus |
| Type | Portable/Benchtop Dew Point Meter |
| Principle | Capacitive Polymer Sensor (Nanoporous Metal Oxide Film) |
| Operating Temperature | -20 °C to +60 °C |
| Accuracy | ±2 °C |
| Repeatability | ±0.5 °C |
| Dew Point Range | -110 °C to +20 °C (standard), optional -60 °C to +20 °C |
| Response Time (T95) | ≤3 min (dry-to-wet) |
| Resolution | 0.1 °C |
| Temperature Compensation Range | -40 °C to +70 °C |
| Flow Rate | 1–5 SCFH (recommended 2–4 SCFH) |
| Pressure Measurement | Built-in absolute pressure sensor with dew point correction |
| Data Storage | >10,000 records (dew point, temperature, pressure) |
| Enclosure Rating | IP67/IP68 |
| Intrinsically Safe | Class I, Div. 1, Groups A, B, C, D |
| Dimensions | 142 × 180 × 146 mm (L×W×H) |
| Weight | 2.6 kg |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | DPT-810 Series |
| Product Type | Online Dew Point Transmitter |
| Measurement Principle | Capacitive Polymer/Metal Oxide Thin-Film Sensor |
| Operating Temperature Range | −20 °C to +60 °C |
| Accuracy | ±2 °C (at −40 °C to +20 °C dp) |
| Repeatability | ±0.5 °C |
| Dew Point Range | −110 °C to +20 °C dp |
| Response Time (95% step) | 180 s |
| Output Signal | 4–20 mA (2-wire, 20–28 VDC) |
| Enclosure Rating | IP68 |
| Housing Material | 316 Stainless Steel |
| Process Connection | 3/4″–16 UNF |
| Max. Operating Pressure | 6 bar |
| Weight | 0.17 kg |
| Dimensions (L × Ø) | 138.4 mm × 30 mm |
| Resolution | <0.01 °C dp |
| Compliance | CE, NIST-Traceable Calibration, ATEX/IECEx Optional (with certified housing variant) |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | DPT-830 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Capacitive Metal Oxide Thin-Film Sensor (Nanoporous Al₂O₃-based) |
| Operating Temperature Range | 0 °C to +45 °C |
| Dew Point Range | −110 °C to +20 °C |
| Accuracy | ±2 °C |
| Repeatability | ±0.8 °C |
| Response Time (T90) | < 3 min |
| Minimum Flow Rate | > 3 SCFH |
| Output Signals | 4–20 mA (user-configurable range), RS232 (configuration & data access), RS485 (Modbus RTU), Optional 433 MHz RF Wireless |
| Relay Outputs | 2 × 10 A / 240 V AC, fully user-configurable |
| Data Logging | Optional |
| Calibration Traceability | NIST-traceable |
| Safety Certification | Optional Intrinsically Safe (IS) Rating |
| Probe Configuration | Optional Remote-Mount Sensor Head |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | DPT-900 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | -20 °C to +60 °C |
| Accuracy | ±2 °C |
| Repeatability | ±0.5 °C |
| Dew Point Range | -110 °C to +20 °C |
| Response Time | ≤3 min (to 95% of step change, dry-to-wet) |
| Gas Flow Rate | >1 L/min |
| IP Rating | IP66/IP68 |
| Hazardous Area Certifications | FM/CSA Class I Div 1 Groups B, C, D |
| ATEX/IECEx | Ex d IIC T6 Gb |
| Enclosure Material | Aluminum (standard), optional 316L stainless steel |
| Dimensions | 226 × 147 × 147 mm (L×W×H) |
| Weight | 2.5 kg |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | DPT-910 |
| Type | Online Dew Point Analyzer |
| Principle | Chilled-Mirror Hygrometry (Nanoporous Metal Oxide Sensor) |
| Measurement Range | −110 °C to +20 °C (dew point) |
| Accuracy | ±2 °C |
| Operating Temperature | −20 °C to +60 °C |
| Enclosure Rating | IP66 & IP68 |
| Hazardous Area Certifications | FM/CSA Class I, Div 1, Groups B, C, D |
| ATEX/IECEx | Ex d IIC T6 Gb / Ex d IIIC T6 Db |
| Gas Inlet/Outlet | 1/4″ Swagelok stainless steel fittings |
| Sample Flow Rate | >1 L/min |
| Power Options | 90–260 VAC, 47–440 Hz |
| Outputs | Isolated RS-422 |
| Housing | Fiberglass-reinforced polymer (FRP) enclosure with large optical-grade viewport |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | DPT-990EX |
| Product Type | Online Dew Point Meter |
| Measurement Principle | Chilled-Mirror–Based Electrochemical Metal Oxide Sensor (Nanoporous Metal Oxide Film) |
| Operating Temperature Range | −110 °C to +20 °C (Dew Point) |
| Ambient Operating Temperature | −20 °C to +60 °C |
| Accuracy | ±1 °C |
| Repeatability | ±1 °C |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC (47–63 Hz) or 12–24 VDC (10 VA) |
| Output Signal | 4–20 mA HART-enabled analog output |
| Pressure Limit | ≤68 bar (gauge) |
| Sample Flow Rate | >1 NL/min |
| Certification | FM/CSA Class I, Div 1, Groups B, C, D |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PLD-GRS6 |
| Price | USD 6,700 (approx.) |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 1 μg – 500 mg H₂O |
| Sensitivity | 0.1 μg |
| Accuracy | ±5% ±1 μg |
| Control System | PULL T 8.0 Test Platform |
| Single-Test Duration | 2–4 min |
| Endpoint Detection | Dual Platinum Electrodes |
| Titration Cell Volume | 150 mL |
| Stirring Method | Magnetic Stirrer |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz |
| Power Consumption | 40 W |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤70% |
| Compliance Standards | GB/T 7600, GB/T 11133, GB/T 6283, SH/T 0207, SH/T 0246, SH/T 0255 |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | 330XM |
| Heating Source | Halogen Lamp |
| Display | High-Contrast VFD Screen |
| Weighing System | Integrated 320XB Precision Electronic Balance |
| Sensor Technology | MFR Electromagnetic Force Restoration |
| Construction | Full Die-Cast Aluminum Housing |
| Calibration | External Calibration Mode |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ) |
| Regulatory Features | Real-Time Clock, Password Protection, Mechanical Safety Interlock |
| Connectivity | Standard RS232 & USB |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | EM120-HR |
| Heating Source | Halogen Lamp |
| Display | Backlit LCD with Graphical Real-Time Moisture Trend Plot |
| Construction | Full Cast-Aluminum Housing |
| Calibration | Fully Automatic Smart Calibration System (SCS) |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ), GxP-Compliant Real-Time Clock, Multi-Level User Access Control with Password Protection |
| Software Features | Built-in Automatic Repeatability Test (ART), Checkweighing, Statistical Analysis |
| Connectivity | Standard RS232 & USB |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM120 |
| Maximum Capacity | 124 g |
| Minimum Readability | 0.001 g |
| Moisture Resolution | 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Drying Time Range | 0.1–99.9 min |
| Termination Modes | Automatic, Semi-Automatic (Δdigit/sec or Δ%/sec), Fixed-Time |
| Data Output Interval | 0.1–10.0 min |
| Password Protection | Yes |
| Statistical Functions | Count, Mean, Max, Min, Standard Error |
| Interface | RS232 |
| Memory | 50 Method Programs, 999 Test Records |
| Preheating | 30–100 °C |
| Multi-Stage Heating | 3 programmable segments (temp + time per stage) |
| Boost Mode | 140% target temp for first 3 min |
| Firmware Update | Remote via network |