- All
- Favorite
- Popular
- Most rated
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711 |
| Internal Chamber Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²), dual-standard flame burners |
| Temperature Control | External auxiliary heating jacket |
| Safety Features | Explosive-relief aluminum foil lining, pressure-regulated vent port with capacity bottle, top/bottom pneumatic actuators |
| Cooling | Integrated recirculating water chiller (MEDTHERM water-cooled heat flux meter included, NIST-traceable calibration certificate provided) |
| Weighing System | 0–5000 g capacity, 0.01 g readability |
| Optical Calibration | Motorized ND2 neutral density filter wheel with Clear/Filter/Dark auto-selection |
| Light Source | Uniform incandescent collimated beam |
| Data Interface | Touchscreen PC with integrated reporting and thermal gravimetric analysis (TGA) module |
| Optional Add-ons | Dräger gas detection tubes, FTIR coupling interface for smoke gas speciation |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SDB |
| Chamber Internal Dimensions | 914 mm × 914 mm × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001% |
| Radiation Sources | ASTM E662 radiant panel (25 kW/m²) and ISO 5659-2 conical heater (50 kW/m²) |
| Flame Sources | ASTM E662 pilot flame burner, ISO 5659-2 burner, NES 711 burner with mixing fan |
| Temperature Control | External auxiliary heating jacket for chamber thermal stabilization |
| Pressure Regulation | Top-mounted pressure relief port linked to calibrated volume bottle |
| Safety Features | Explosion-resistant aluminum foil lining, automatic pneumatic actuators for top/bottom access, full-front opening door |
| Cooling | Integrated recirculating water chiller with NIST-traceable water-cooled heat flux meter (50 kW/m² range) |
| Mass Loss Measurement | Built-in balance (0–2000 g, ±0.1 g) for MOD testing and thermogravimetric analysis |
| Calibration & Compliance | Compliant with ASTM E662, ISO 5659-2, NES 711 |
| Brand | Marlin Engineering (MEI) |
|---|---|
| Origin | USA |
| Model | ME1100-1 |
| Compliance | FAA-recognized NBS-type smoke density chamber |
| Standards | FAA AC 20-135, BSS 7238, BSS 7239, AITM 2.0007, AITM 3.0005, HB 6577 |
| Temperature Control | PID-regulated radiant heating system |
| Optical Path | Fixed optical platform with calibrated photometric assembly |
| Light Source | Stable tungsten-halogen lamp with collimated beam |
| Transmittance Measurement Range | 0–100% (logarithmic smoke density scale: 0–1000 Ds) |
| Gas Sampling Interface | Four Swagelok® ports on chamber ceiling |
| Heat Flux Capability | 0–50 kW/m² (with traceable heat flux meter) |
| Sample Handling | Pneumatic specimen insertion mechanism |
| Ignition | Electronic spark ignition burner |
| Calibration | Three neutral density filters (certified OD values), stainless steel specimen holders (3× standard + 1 blank), gas flow and pressure regulation for controlled flaming combustion |
| Ancillary | Integrated smoke toxicity test kit (portable sampling pump, colorimetric detector tubes), real-time data acquisition system with ASTM/ISO-compliant reporting engine |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | SB 2005 |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Wall Finish | Enamel-coated steel |
| Radiation Source | Optional ISO 5659-2 compliant conical heater (0–50 kW/m²) |
| Photodetector | S4 spectral response photomultiplier tube (dark current <10⁻⁹ A) with silicon photodiode backup |
| Temperature Monitoring | Digital display with calibrated thermocouple |
| Data Acquisition | Integrated software compliant with ISO 5659-2 reporting requirements |
| Gas Sampling | Dedicated port for detector tubes (e.g., CO, HCl, HCN) |
| Calibration | NIST-traceable radiometric calibration certificate available for heat flux meter |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | XP-2 |
| Compliance | ASTM D2843 |
| Chamber Coating | PTFE (Teflon®) Interior |
| Light Source | Calibrated Incandescent Lamp |
| Detector | Cosine-Corrected Silicon Photodiode with Visible-Spectrum Filter (380–780 nm) |
| Primary Burner Pressure | 256 kPa |
| Auxiliary Burner | Integrated for Dripping Combustion Control |
| Data Acquisition | 15-s Interval Transmittance Logging |
| Output | SDR (Smoke Density Rating) Calculation & Multi-Sample Comparative Analysis |
| Software | Windows-Based, CFR Part 11 Compliant Audit Trail Optional |
| Chamber Viewing Window | Optical-Grade Quartz with EXIT Marking (White-on-Red) |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | XP-2 |
| Compliance | ASTM D2843 |
| Chamber Coating | PTFE (Teflon®) Interior |
| Light Source | Calibrated Tungsten Filament Lamp |
| Detector | Cosine-Corrected Silicon Photodiode with Visible-Spectrum Bandpass Filter (380–780 nm) |
| Main Burner Pressure | 256 kPa |
| Auxiliary Burner | Integrated for Dripping Combustion Control |
| Data Acquisition Interval | 15 s |
| Output | SDR (Smoke Density Rating) Integral & Time-Resolved Curve |
| Software | ASTM-D2843-Compliant Reporting Suite with Multi-Sample Overlay, Comparative Analysis, and CFR 21 Part 11–Ready Audit Trail |
| Brand | MOTIS |
|---|---|
| Model | XP-2 |
| Standard Compliance | ASTM D2843 |
| Chamber Coating | PTFE (Teflon®) Interior |
| Light Source | Calibrated Incandescent Lamp |
| Photodetector | Cosine-Corrected Silicon Photodiode with Visible-Spectrum Bandpass Filter (380–780 nm) |
| Main Burner Pressure | 256 kPa |
| Auxiliary Burner | Integrated for Dripping Combustion Control |
| Data Acquisition Interval | 15 s |
| Output | SDR (Smoke Density Rating) Integral & Time-Resolved Curve |
| Software Features | Multi-sample SDR Overlay, Comparative Analysis, CFR 21 Part 11–Ready Report Export |
| Chamber Marking | High-Contrast “EXIT” Label on White Background |
| Viewing Window | Optical-Grade Quartz, UV/IR-Blocked |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711 |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²) |
| Combustion Options | ASTM E662 flame burner, ISO 5659-2 flame burner, NES 711 flame burner + mixing fan |
| Temperature Control | External auxiliary heating jacket for chamber thermal stabilization |
| Safety Features | Explosion-resistant aluminum foil lining, pressure-relief port with calibrated volume bottle, dual pneumatic actuators (top/bottom), Teflon-coated interior walls |
| Data Acquisition | Integrated touchscreen PC with dedicated software, GLP-compliant audit trail, built-in thermal printer |
| Optional Modules | Dräger gas detection tubes (toxicity screening), FTIR coupling interface (smoke gas speciation), water-cooled Medtherm heat flux meter (NIST-traceable), wind-cooled copper calorimeter, integrated balance (0–5000 g, ±0.01 g) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | 3MC |
| Chamber Volume | 27 m³ (3000 mm × 3000 mm × 3000 mm) |
| Compliance | IEC 61034, BS 6853, GB/T 17651.1–2 |
| Light Source | 2896 K tungsten halogen lamp with constant-current driver |
| Detector | Cosine-corrected silicon photodiode with color filter |
| Optical Resolution | 0.01% transmittance |
| Exhaust | Top-mounted centrifugal fan |
| Ignition | Remote-controlled surface igniter |
| Sample Support | Stainless steel alcohol tray and adjustable cable test stand |
| Data System | Integrated industrial touchscreen PC with thermal printer |
| Chamber Lining | PTFE-coated SUS 304 stainless steel interior |
| Viewing | Dual-side tempered glass ports and front observation window |
| Air Balance | Bottom perimeter ventilation openings |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²) and ISO 5659-2 conical heater (50 kW/m²) |
| Ignition Systems | ASTM E662 flame burner, ISO 5659-2 flame burner, NES 711 flame burner with mixing fan |
| Temperature Control | External auxiliary heating jacket for chamber thermal stabilization |
| Safety Features | Explosion-proof aluminum foil lining, pressure-relief port linked to calibrated volume bottle, dual pneumatic actuators (top/bottom), Teflon-coated interior walls |
| Cooling | Integrated recirculating water chiller (no external supply required), water-cooled MEDTHERM heat flux meter (NIST-traceable calibration) |
| Mass Measurement | Integrated balance, 0–5000 g range, 0.01 g resolution |
| Data Acquisition | Touchscreen PC-based control software with real-time transmittance logging, automated filter wheel (Clear/Filter/Dark/ND2), built-in thermal printer |
| Compliance | ASTM E662, ISO 5659-2, GB/T 8323, NES 711 |
| Brand | MOTIS |
|---|---|
| Model | SDB |
| Origin | Shanghai, China |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical Detection System | Side-window Photomultiplier Tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001% |
| Radiation Sources | ASTM E662 Radiant Panel (25 kW/m²) and ISO 5659-2 Radiant Cone (50 kW/m²) |
| Ignition Sources | ASTM E662 Flame Burner, ISO 5659-2 Flame Burner, NES 711 Flame Burner with Mixing Fan |
| Temperature Control | External Auxiliary Heating Jacket |
| Pressure Regulation | Automatic Pressure Relief Valve with Calibrated Volume Bottle |
| Safety Features | Explosion-Proof Aluminum Foil Liner, Top/Bot Pneumatic Cylinders, Full-Access Front Door |
| Cooling Options | Air-Cooled Copper Heat Flux Meter, Water-Cooled MEDTHERM Heat Flux Meter (NIST-traceable), Self-contained Recirculating Chiller |
| Mass Loss Measurement | Integrated Balance (0–5000 g, ±0.01 g) |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711, GB/T 8323 |
| Software | Integrated Touchscreen PC with Real-time Transmittance Logging, Report Generation, and Calibration Workflow |
| Optional Add-ons | Dräger Gas Detection Tubes, FTIR Coupling Interface for Smoke Toxicity & Speciation Analysis |