Empowering Scientific Discovery

MOTIS Combustion Technology (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
ModelSDB
Compliance StandardsASTM E662, ISO 5659-2, NES 711
Internal Chamber Dimensions914 × 914 × 610 mm
Optical SystemSide-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001%
Radiation SourcesASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²), dual-standard flame burners
Temperature ControlExternal auxiliary heating jacket
Safety FeaturesExplosive-relief aluminum foil lining, pressure-regulated vent port with capacity bottle, top/bottom pneumatic actuators
CoolingIntegrated recirculating water chiller (MEDTHERM water-cooled heat flux meter included, NIST-traceable calibration certificate provided)
Weighing System0–5000 g capacity, 0.01 g readability
Optical CalibrationMotorized ND2 neutral density filter wheel with Clear/Filter/Dark auto-selection
Light SourceUniform incandescent collimated beam
Data InterfaceTouchscreen PC with integrated reporting and thermal gravimetric analysis (TGA) module
Optional Add-onsDräger gas detection tubes, FTIR coupling interface for smoke gas speciation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelSDB
Chamber Internal Dimensions914 mm × 914 mm × 610 mm
Optical SystemSide-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001%
Radiation SourcesASTM E662 radiant panel (25 kW/m²) and ISO 5659-2 conical heater (50 kW/m²)
Flame SourcesASTM E662 pilot flame burner, ISO 5659-2 burner, NES 711 burner with mixing fan
Temperature ControlExternal auxiliary heating jacket for chamber thermal stabilization
Pressure RegulationTop-mounted pressure relief port linked to calibrated volume bottle
Safety FeaturesExplosion-resistant aluminum foil lining, automatic pneumatic actuators for top/bottom access, full-front opening door
CoolingIntegrated recirculating water chiller with NIST-traceable water-cooled heat flux meter (50 kW/m² range)
Mass Loss MeasurementBuilt-in balance (0–2000 g, ±0.1 g) for MOD testing and thermogravimetric analysis
Calibration & ComplianceCompliant with ASTM E662, ISO 5659-2, NES 711
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMarlin Engineering (MEI)
OriginUSA
ModelME1100-1
ComplianceFAA-recognized NBS-type smoke density chamber
StandardsFAA AC 20-135, BSS 7238, BSS 7239, AITM 2.0007, AITM 3.0005, HB 6577
Temperature ControlPID-regulated radiant heating system
Optical PathFixed optical platform with calibrated photometric assembly
Light SourceStable tungsten-halogen lamp with collimated beam
Transmittance Measurement Range0–100% (logarithmic smoke density scale: 0–1000 Ds)
Gas Sampling InterfaceFour Swagelok® ports on chamber ceiling
Heat Flux Capability0–50 kW/m² (with traceable heat flux meter)
Sample HandlingPneumatic specimen insertion mechanism
IgnitionElectronic spark ignition burner
CalibrationThree neutral density filters (certified OD values), stainless steel specimen holders (3× standard + 1 blank), gas flow and pressure regulation for controlled flaming combustion
AncillaryIntegrated smoke toxicity test kit (portable sampling pump, colorimetric detector tubes), real-time data acquisition system with ASTM/ISO-compliant reporting engine
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFESTEC
OriginSouth Korea
ModelSB 2005
Chamber Internal Dimensions914 × 914 × 610 mm
Wall FinishEnamel-coated steel
Radiation SourceOptional ISO 5659-2 compliant conical heater (0–50 kW/m²)
PhotodetectorS4 spectral response photomultiplier tube (dark current <10⁻⁹ A) with silicon photodiode backup
Temperature MonitoringDigital display with calibrated thermocouple
Data AcquisitionIntegrated software compliant with ISO 5659-2 reporting requirements
Gas SamplingDedicated port for detector tubes (e.g., CO, HCl, HCN)
CalibrationNIST-traceable radiometric calibration certificate available for heat flux meter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
ModelXP-2
ComplianceASTM D2843
Chamber CoatingPTFE (Teflon®) Interior
Light SourceCalibrated Incandescent Lamp
DetectorCosine-Corrected Silicon Photodiode with Visible-Spectrum Filter (380–780 nm)
Primary Burner Pressure256 kPa
Auxiliary BurnerIntegrated for Dripping Combustion Control
Data Acquisition15-s Interval Transmittance Logging
OutputSDR (Smoke Density Rating) Calculation & Multi-Sample Comparative Analysis
SoftwareWindows-Based, CFR Part 11 Compliant Audit Trail Optional
Chamber Viewing WindowOptical-Grade Quartz with EXIT Marking (White-on-Red)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
ModelXP-2
ComplianceASTM D2843
Chamber CoatingPTFE (Teflon®) Interior
Light SourceCalibrated Tungsten Filament Lamp
DetectorCosine-Corrected Silicon Photodiode with Visible-Spectrum Bandpass Filter (380–780 nm)
Main Burner Pressure256 kPa
Auxiliary BurnerIntegrated for Dripping Combustion Control
Data Acquisition Interval15 s
OutputSDR (Smoke Density Rating) Integral & Time-Resolved Curve
SoftwareASTM-D2843-Compliant Reporting Suite with Multi-Sample Overlay, Comparative Analysis, and CFR 21 Part 11–Ready Audit Trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
ModelXP-2
Standard ComplianceASTM D2843
Chamber CoatingPTFE (Teflon®) Interior
Light SourceCalibrated Incandescent Lamp
PhotodetectorCosine-Corrected Silicon Photodiode with Visible-Spectrum Bandpass Filter (380–780 nm)
Main Burner Pressure256 kPa
Auxiliary BurnerIntegrated for Dripping Combustion Control
Data Acquisition Interval15 s
OutputSDR (Smoke Density Rating) Integral & Time-Resolved Curve
Software FeaturesMulti-sample SDR Overlay, Comparative Analysis, CFR 21 Part 11–Ready Report Export
Chamber MarkingHigh-Contrast “EXIT” Label on White Background
Viewing WindowOptical-Grade Quartz, UV/IR-Blocked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
ModelSDB
Compliance StandardsASTM E662, ISO 5659-2, NES 711
Chamber Internal Dimensions914 × 914 × 610 mm
Optical SystemSide-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001%
Radiation SourcesASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²)
Combustion OptionsASTM E662 flame burner, ISO 5659-2 flame burner, NES 711 flame burner + mixing fan
Temperature ControlExternal auxiliary heating jacket for chamber thermal stabilization
Safety FeaturesExplosion-resistant aluminum foil lining, pressure-relief port with calibrated volume bottle, dual pneumatic actuators (top/bottom), Teflon-coated interior walls
Data AcquisitionIntegrated touchscreen PC with dedicated software, GLP-compliant audit trail, built-in thermal printer
Optional ModulesDräger gas detection tubes (toxicity screening), FTIR coupling interface (smoke gas speciation), water-cooled Medtherm heat flux meter (NIST-traceable), wind-cooled copper calorimeter, integrated balance (0–5000 g, ±0.01 g)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
Model3MC
Chamber Volume27 m³ (3000 mm × 3000 mm × 3000 mm)
ComplianceIEC 61034, BS 6853, GB/T 17651.1–2
Light Source2896 K tungsten halogen lamp with constant-current driver
DetectorCosine-corrected silicon photodiode with color filter
Optical Resolution0.01% transmittance
ExhaustTop-mounted centrifugal fan
IgnitionRemote-controlled surface igniter
Sample SupportStainless steel alcohol tray and adjustable cable test stand
Data SystemIntegrated industrial touchscreen PC with thermal printer
Chamber LiningPTFE-coated SUS 304 stainless steel interior
ViewingDual-side tempered glass ports and front observation window
Air BalanceBottom perimeter ventilation openings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
ModelSDB
Chamber Internal Dimensions914 × 914 × 610 mm
Optical SystemSide-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution 0.0001%
Radiation SourcesASTM E662 radiant heater (25 kW/m²) and ISO 5659-2 conical heater (50 kW/m²)
Ignition SystemsASTM E662 flame burner, ISO 5659-2 flame burner, NES 711 flame burner with mixing fan
Temperature ControlExternal auxiliary heating jacket for chamber thermal stabilization
Safety FeaturesExplosion-proof aluminum foil lining, pressure-relief port linked to calibrated volume bottle, dual pneumatic actuators (top/bottom), Teflon-coated interior walls
CoolingIntegrated recirculating water chiller (no external supply required), water-cooled MEDTHERM heat flux meter (NIST-traceable calibration)
Mass MeasurementIntegrated balance, 0–5000 g range, 0.01 g resolution
Data AcquisitionTouchscreen PC-based control software with real-time transmittance logging, automated filter wheel (Clear/Filter/Dark/ND2), built-in thermal printer
ComplianceASTM E662, ISO 5659-2, GB/T 8323, NES 711
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
ModelSDB
OriginShanghai, China
Chamber Internal Dimensions914 × 914 × 610 mm
Optical Detection SystemSide-window Photomultiplier Tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001%
Radiation SourcesASTM E662 Radiant Panel (25 kW/m²) and ISO 5659-2 Radiant Cone (50 kW/m²)
Ignition SourcesASTM E662 Flame Burner, ISO 5659-2 Flame Burner, NES 711 Flame Burner with Mixing Fan
Temperature ControlExternal Auxiliary Heating Jacket
Pressure RegulationAutomatic Pressure Relief Valve with Calibrated Volume Bottle
Safety FeaturesExplosion-Proof Aluminum Foil Liner, Top/Bot Pneumatic Cylinders, Full-Access Front Door
Cooling OptionsAir-Cooled Copper Heat Flux Meter, Water-Cooled MEDTHERM Heat Flux Meter (NIST-traceable), Self-contained Recirculating Chiller
Mass Loss MeasurementIntegrated Balance (0–5000 g, ±0.01 g)
Compliance StandardsASTM E662, ISO 5659-2, NES 711, GB/T 8323
SoftwareIntegrated Touchscreen PC with Real-time Transmittance Logging, Report Generation, and Calibration Workflow
Optional Add-onsDräger Gas Detection Tubes, FTIR Coupling Interface for Smoke Toxicity & Speciation Analysis