Empowering Scientific Discovery

MOTIS Combustion Technology (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSBI
PricingAvailable Upon Request
ComplianceEN 13823, GB/T 20284
Core Measurement PrincipleOxygen Consumption Calorimetry & Optical Smoke Density Analysis
Key OutputsFIGRA, THR, SMOGRA, TSP, LFS, Droplet Observation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHTI
PricingAvailable Upon Request
Standard ComplianceEN 367, ISO 9151, AQ 6103–2007
Heat Flux80 kW/m²
Thermocouple TypeCopper Disc Calorimeter (ISO 9151-compliant)
Temperature Rise Thresholds12 °C and 24 °C above baseline (25 °C)
CoolingForced-air cooling for calorimeter
ControlPneumatic actuation + PC-based software automation
Power Supply220 V, 50 Hz
Gas SupplyPropane + compressed air
Dimensions (W×H×D)500 × 500 × 500 mm
Ambient Test Environment25 ± 5 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSBI
PricingAvailable Upon Request
Standards ComplianceEN 13823, GB/T 20284
Core Measurement PrinciplesOxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection
Key OutputsFIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
ModelSDB
OriginShanghai, China
Chamber Internal Dimensions914 × 914 × 610 mm
Optical Detection SystemSide-window Photomultiplier Tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001%
Radiation SourcesASTM E662 Radiant Panel (25 kW/m²) and ISO 5659-2 Radiant Cone (50 kW/m²)
Ignition SourcesASTM E662 Flame Burner, ISO 5659-2 Flame Burner, NES 711 Flame Burner with Mixing Fan
Temperature ControlExternal Auxiliary Heating Jacket
Pressure RegulationAutomatic Pressure Relief Valve with Calibrated Volume Bottle
Safety FeaturesExplosion-Proof Aluminum Foil Liner, Top/Bot Pneumatic Cylinders, Full-Access Front Door
Cooling OptionsAir-Cooled Copper Heat Flux Meter, Water-Cooled MEDTHERM Heat Flux Meter (NIST-traceable), Self-contained Recirculating Chiller
Mass Loss MeasurementIntegrated Balance (0–5000 g, ±0.01 g)
Compliance StandardsASTM E662, ISO 5659-2, NES 711, GB/T 8323
SoftwareIntegrated Touchscreen PC with Real-time Transmittance Logging, Report Generation, and Calibration Workflow
Optional Add-onsDräger Gas Detection Tubes, FTIR Coupling Interface for Smoke Toxicity & Speciation Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSBI
PricingUpon Request
Standards ComplianceEN 13823, GB/T 20284
Measurement PrinciplesOxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection
Key OutputsFIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
ModelPFET
ComplianceIMO A.753, ISO 19921–1 & 19921–2, ISO 10497, FTP Code Annex 2 (Res. A.753)
Test Pressure Range0–20 bar
Thermal Radiation SensorCalibrated heat flux meter (kW/m²)
Cooling SystemIntegrated water-cooled calorimeter mount
Temperature MonitoringDual K-type thermocouples (0–1200 °C)
Sample PositioningMotorized X-Y-Z adjustable test platform
Data AcquisitionPC-based real-time logging software with time-synchronized thermal, pressure, and radiation curves
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCF
PricingAvailable Upon Request
Temperature ControlProgrammable controller with standard temperature ramp profile (e.g., BS 8414 Annex A)
Test DurationUp to 24 h continuous monitoring and control
ComplianceBS 8414-1:2015, BS 8414-2:2015 (aligned with draft GB/T 39173 under development)
Data AcquisitionReal-time display of furnace interior and specimen surface temperatures
Thermocouple ConfigurationIntegrated internal furnace thermocouples + dedicated specimen surface thermocouples
Specimen HandlingFreely accessible test chamber with standardized mounting interface for façade system assemblies