BrandMOTIS
OriginShanghai, China
ModelUIC-4
ConstructionCopper alcohol cups (4 pcs)
Test Angle45° sample support fixture (1 set)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMEI / Marlin Engineering
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelME1500-3 + ME2100-1
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelCTA
Air Flow Range0–3 L/min (digital display, adjustable in 0.1 L/min increments)
Temperature ControlDual-mode PID (programmable ramping and single-point setpoint)
Max Furnace Temperature1100 °C with over-temperature cutoff
Furnace TypeOpenable tubular furnace with imported thermocouple-equipped quartz heating tube
Auxiliary InstrumentsMagnetic stirrer, pH meter, conductivity meter
Air FiltrationActivated carbon + silica gel columns
ComplianceGB/T 17650.1–2–1998, IEC 60754-1/2–1994, EN 50305, BS 6853 Annex B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelWFT
PricingAvailable Upon Request
ComplianceGB/T 29416–2012
Heat Release Rate Peak(3.0 ± 0.5) MW
Total Energy Release (30 min)~4500 MJ
Fuel Load~400 kg Wood
Ignition Delay AlertAutomated 5-min pre-ignition warning
Data AcquisitionReal-time temperature, droplet onset, collapse timing, thermal flux, and flame dynamics
Sensor Suite3 × Medtherm water-cooled heat flux gauges (0–100 kW/m²), 1 × OMEGA anemometer (0–10 m/s, ±0.1 m/s), 30 × OMEGA thermocouples, dual high-resolution CCTV monitoring, Advantech DAQ modules, dedicated control & signal conditioning cabinets
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin ClassificationDomestic (China)
ModelTAI
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelMMS
PricingAvailable Upon Request
Standards ComplianceEN 348, ISO 9150, GB 8965.2–2009, GB/T 17599–1998
Power Supply220 V AC, 50 Hz
Operating Environment20 ± 2 °C, 65 ± 5 % RH
Dimensions (W × H × D)800 × 1200 × 450 mm
Gas SupplyOxygen and Acetylene
Burner Nozzle Diameter1.2 ± 0.1 mm
Specimen Pre-tension175 ± 0.5 g (via calibrated copper weight)
Droplet Guidance Angle45° with high-temperature anti-adhesion coated channel
Metal Feed MechanismStepper motor–driven wire feed system with adjustable linear speed
Backside Temperature SensorCalibrated thermocouple array for real-time fabric rear-surface temperature monitoring
Data LoggingAutomated temperature vs. time acquisition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
ModelVF-1
Compliance StandardsASTM D6413, ISO 6941, GB/T 5455, CFR 1615/1616, CA TB117
Chamber MaterialStainless Steel (304)
Viewing WindowTempered Borosilicate Glass
Burner AdjustmentLinear Sliding Rail with Precision Needle Valve
Sample Holder OptionsMultiple Interchangeable Fixtures for Woven, Knitted, and Nonwoven Textiles
Flame Height Range10–50 mm (adjustable via calibrated needle valve)
Ignition SourceLaboratory-grade Bunsen-type Gas Burner (Propane or Butane)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelCCA
ComplianceGB/T 16172–2007, ISO 5660-1/2/3/4:2002, ASTM E1354–2011
Radiant Heat Flux Range0–100 kW/m²
Mass Loss Measurement0–2000 g ±0.1 g
Oxygen Analysis0–25% vol, ±0.1% accuracy
CO₂/CO Detection0–10% / 0–1% vol, ±0.1% accuracy
Exhaust Flow Control0.024 m³/s min, variable via inverter-driven fan
Laser Smoke Density SystemHe–Ne source (632.8 nm), ±2% stability over 8 h
Data AcquisitionAdvantech industrial modules, 3000 Vdc isolation, 50/60 Hz auto-filtering
SoftwareVB-based, GLP-compliant, with full calibration traceability and audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelNCF
ComplianceISO 1182, GB/T 5464, BS 476-4 & BS 476-11, IMO FTP Code Part 1
Temperature Control Range750 ± 5 °C
Heating MethodRadiant Tube with Kanthal® Resistance Band
Thermocouple TypeOMEGA™ Type K (NiCr-NiAl)
Temperature Monitoring PointsFurnace Chamber, Specimen Surface, Specimen Center
Calibration Capabilities360° Rotatable & Vertically Adjustable Thermocouple Scanning System for Furnace Wall and Internal Temperature Mapping
Airflow StabilizationPTFE-Coated Stainless Steel Inverted Conical Air Stabilizer and Cylindrical Flow Guide
SoftwareIntegrated Windows-Based Data Acquisition, Real-Time Curve Plotting, Automated Report Generation (PDF/Excel), ASTM/ISO-Compliant Data Logging with Timestamped Audit Trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelSBI
ComplianceEN 13823, GB/T 20284
Heat Release Rate MeasurementOxygen consumption calorimetry
Smoke MeasurementOptical density (light extinction) via white-light beam
Flame Spread AssessmentLateral flame spread (LFS) up to 1.5 m × 1.0 m specimen edge
Droplet CollectionIntegrated metal drip tray with thermal shielding
Chamber Dimensions3 m × 3 m × 2.4 m (W × D × H)
Ignition Source31 kW propane corner burner (250 mm × 250 mm × 80 mm) mounted on specimen trolley
Sampling DuctStainless-steel duct with integrated probe zone for multi-parameter gas analysis
Data AcquisitionSimultaneous sampling of O₂, CO, CO₂, flue gas temperature, mass flow, and optical density
Analyzer SpecificationsSiemens OXYMAT 61 (0–25% O₂, ±1% FS/week drift, <3 s response), U23 NDIR (CO: 0–1%, CO₂: 0–10%, ±0.5% FS linearity)
Calibration SupportFull software-based calibration routines per ISO 5660-1 and EN 13823 Annex B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
ModelTPP
OriginShanghai, China
ComplianceNFPA 1971, ASTM D4018, GB 8965.1–2009, ISO 12749
Heat SourceDual Meker burners (38 mm, 5/16″ orifice) + 9× T150 quartz IR tubes
Total incident heat flux83 kW/m² ± 2 kW/m²
Radiant flux range13–40 kW/m² ± 4 kW/m²
Convection source800–1200 BTU/h per burner
Calibrated water-cooled heat flux sensor0–100 kW/m², response <200 ms, emissivity >0.95
Data acquisition20 Hz (50 ms interval), 0.1 °C resolution, ±0.75 °C accuracy, cold-junction compensation
Gas controlRotameter (±2% accuracy, >3 L/min), pressure regulator (0–15 psi), quarter-turn shutoff valve
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
ModelCFRT
ApplicationFire resistance testing of low-voltage power cables (≤ 0.6/1.0 kV)
ComplianceGB/T 19216.11 (equivalent to IEC 60331-11)
Ignition SourceAGF propane ribbon burner (500 mm length, 15 mm nominal width, triple-row 1.32 mm diameter orifices)
Temperature CalibrationOmega 1.5 mm sheathed thermocouple
Gas ControlImported mass flow controllers (accuracy ≥ ±1.5%)
Air–Fuel MixingVenturi-type premixing system
Voltage ControlProgrammable via PC interface or front-panel adjustment
Continuity Monitoring0.25 A DC test current per conductor, LED-based real-time circuit integrity indication
Data AcquisitionDigital multichannel logging of voltage, current, gas flow, air flow, and thermocouple temperature
Safety ProtectionD-II type fuse per GB 13539.5 (2 A), imported miniature circuit breakers per test circuit
Flame StabilizationAutomatic closed-loop control of propane/air ratio for stable 750 °C or 950 °C flame profile
Software FeaturesStandard-compliant report generation, pre-test parameter configuration (cable specs, standard selection, max duration), audit-trail-capable data logging, calibration history management (≥10 min stabilized acquisition)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
ModelSDB
Compliance StandardsASTM E662, ISO 5659-2, NES 711
Internal Chamber Dimensions914 × 914 × 610 mm
Optical SystemSide-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001%
Radiation SourcesASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²), dual-standard flame burners
Temperature ControlExternal auxiliary heating jacket
Safety FeaturesExplosive-relief aluminum foil lining, pressure-regulated vent port with capacity bottle, top/bottom pneumatic actuators
CoolingIntegrated recirculating water chiller (MEDTHERM water-cooled heat flux meter included, NIST-traceable calibration certificate provided)
Weighing System0–5000 g capacity, 0.01 g readability
Optical CalibrationMotorized ND2 neutral density filter wheel with Clear/Filter/Dark auto-selection
Light SourceUniform incandescent collimated beam
Data InterfaceTouchscreen PC with integrated reporting and thermal gravimetric analysis (TGA) module
Optional Add-onsDräger gas detection tubes, FTIR coupling interface for smoke gas speciation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginShanghai, China
ModelNFP-1
ComplianceNFPA 701 (2004 & 2009 Ed.), Test Method 1
Burner TypeMeker Burner
Heat Output10,500 BTU/hr
IgnitionAutomatic spark ignition
Burn DurationFixed 20 s ± 0.1 s
Timer Resolution0.1 s
Sample HolderStandard ASTM/NFPA-compliant specimen clamp
Max Fabric Areal Density700 g/m² (21 oz/yd²)
Chamber ConstructionCalcium silicate board lined with stainless steel exterior
ConfigurationOpen-top vertical combustion chamber
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelRFS
Standards ComplianceASTM E162, ASTM E365, ASTM D3675
Radiant Panel Dimensions300 × 460 mm
Reflector Surface305 × 457 mm, Porous Cement
Max Reflector Temp815 °C
Calibration BurnerMethane (95% purity, 20 L/min @ 150 mbar)
Pilot BurnerAcetylene (0.5 L/min @ 150 mbar)
Propane Burner1.0 L/s @ 20 mbar
Compressed Air Supply50 L/s @ 700 Pa water column
Exhaust Airflow Velocity0.5 m/s ±0.05 m/s
Black-Body Temperature Control Range180–230 °C (±5 °C accuracy)
Heat Flux Measurement Range0–100 kW/m² (±10% full scale, Schmidt-Boelter type)
Data AcquisitionGPIB/USB interface DAQ system with 19" touchscreen control unit
Frame Dimensions1850 H × 700 D × 1250 L mm
Electrical Supply220 V AC, 60 Hz, 12 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMEI/Marlin Engineering
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelME1500-3 + ME1700-3
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelBFT
PricingAvailable Upon Request
ComplianceASTM D4151
ConstructionStainless Steel Enclosure with Tempered Glass Viewing Window
Ignition SourceNo. 18 Needle Burner (Adjustable Flame Height)
Timing Resolution0.01 s
AccessoriesStandardized Brushing Device, Sample Holder Assembly, Stainless Steel Specimen Clamps
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMEI / Marlin Engineering
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelME1500-1/3
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelSBI-
ComplianceGB/T 20284-2006, EN 13823
Power Supply380 V AC, 50 Hz
Fuel95% commercial propane
Exhaust Flow Rate≥8000 m³/h
Gas Flow ControlMass flow controller (0–2.3 g/s C₃H₈, ±1% FS accuracy)
Temperature MeasurementK-type thermocouples (±0.5 °C)
Pressure SensingDifferential pressure transducers (±0.5 Pa)
Oxygen Analysis0–25% vol, T90 ≤ 2 s, linearity < ±0.1% O₂
CO/CO₂ AnalysisCO (0–1% vol, ±0.02% vol), CO₂ (0–10% vol, ±1% FS), T90 ≤ 2 s
Smoke MeasurementWhite-light extinction method (24 V, 6 W incandescent source
Data AcquisitionNI-compatible 16-bit analog input modules, LabVIEW-based real-time system
Cooling SystemActive chiller (≤5 °C operational setpoint)
FiltrationDual-stage (coarse ≤25 µm, fine ≤3 µm)
Exhaust DuctJ-shaped double-walled 304 stainless steel (ID 315 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelRCF
ComplianceGB/T 30735-2014, ENV 1187 (t1), ISO 12468-1
Sample Mounting Angle Range0–50°
Air Duct Adjustment Range0–35°
Airflow Capacityup to 250 m³/min
Fan Motor Power5.5 kW
Radiation Panel Dimensions600 mm × 600 mm
Ignition MethodElectric Spark with Thermocouple-Monitored Flame Supervision
Wind Speed MeasurementThree Vane Anemometers (±0.1 m/s accuracy)
Construction MaterialsSUS304 Stainless Steel Duct (2 mm thickness), Structural Steel Frame with Pneumatic & Servo-Driven Actuation
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelSCT
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
ModelVFT
Standard ComplianceISO 15025, AQ 6103–2007
Ignition SourcePropane burner
Ignition DurationAdjustable (default 10 s)
Sample OrientationVertical
Measured ParametersAfterflame time, afterglow time, char length
Burner ControlStepper motor–actuated angular positioning for bottom-edge and edge ignition
DisplayIntegrated LCD interface
Power Supply220 V, 50 Hz
Ambient Conditions20 ± 2 °C, 65 ± 5 % RH
Dimensions (W × H × D)410 × 900 × 380 mm
Gas SupplyPropane
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelCCT
Heating Source5 kW Cone Heater (0–100 kW/m²)
Sample Capacity100 mm × 100 mm × 50 mm
Mass Measurement Range0–3000 g (±0.1 g)
Oxygen AnalyzerABB Paramagnetic (0–25% O₂)
CO/CO₂ AnalyzersABB NDIR (CO: 0–1%
CO₂0–10%)
Smoke MeasurementHe-Ne Laser System (632.8 nm)
Exhaust Flow Control0–50 g/s (±0.1 g/s)
Heat Flux CalibrationNIST-Traceable Foil Heat Flux Meter (0–100 kW/m², ±3% accuracy)
ComplianceISO 5660-1 & -2, ASTM E1354, GB/T 16172, BS 476-15
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOTIS
OriginJiangsu, China
ModelGCF
ComplianceGB/T 29416–2012 Annex C, BS 8414
Temperature ControlProgrammable controller with standardized temperature ramp profile
Test Duration24 h continuous monitoring
Thermocouple ConfigurationInternal furnace thermocouples + surface-mounted sample thermocouples
Data LoggingReal-time temperature display and curve plotting
Pass/Fail CriteriaBased on thermal trajectory divergence (sample center temperature vs. furnace ambient temperature)
Software FunctionalityAutomated test execution, time-synchronized thermal data acquisition, and smoldering propensity classification per GB/T 29416–2012