| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UIC-4 |
| Construction | Copper alcohol cups (4 pcs) |
| Test Angle | 45° sample support fixture (1 set) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | CTA |
| Air Flow Range | 0–3 L/min (digital display, adjustable in 0.1 L/min increments) |
| Temperature Control | Dual-mode PID (programmable ramping and single-point setpoint) |
| Max Furnace Temperature | 1100 °C with over-temperature cutoff |
| Furnace Type | Openable tubular furnace with imported thermocouple-equipped quartz heating tube |
| Auxiliary Instruments | Magnetic stirrer, pH meter, conductivity meter |
| Air Filtration | Activated carbon + silica gel columns |
| Compliance | GB/T 17650.1–2–1998, IEC 60754-1/2–1994, EN 50305, BS 6853 Annex B |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | VF-1 |
| Compliance Standards | ASTM D6413, ISO 6941, GB/T 5455, CFR 1615/1616, CA TB117 |
| Chamber Material | Stainless Steel (304) |
| Viewing Window | Tempered Borosilicate Glass |
| Burner Adjustment | Linear Sliding Rail with Precision Needle Valve |
| Sample Holder Options | Multiple Interchangeable Fixtures for Woven, Knitted, and Nonwoven Textiles |
| Flame Height Range | 10–50 mm (adjustable via calibrated needle valve) |
| Ignition Source | Laboratory-grade Bunsen-type Gas Burner (Propane or Butane) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | NCF |
| Compliance | ISO 1182, GB/T 5464, BS 476-4 & BS 476-11, IMO FTP Code Part 1 |
| Temperature Control Range | 750 ± 5 °C |
| Heating Method | Radiant Tube with Kanthal® Resistance Band |
| Thermocouple Type | OMEGA™ Type K (NiCr-NiAl) |
| Temperature Monitoring Points | Furnace Chamber, Specimen Surface, Specimen Center |
| Calibration Capabilities | 360° Rotatable & Vertically Adjustable Thermocouple Scanning System for Furnace Wall and Internal Temperature Mapping |
| Airflow Stabilization | PTFE-Coated Stainless Steel Inverted Conical Air Stabilizer and Cylindrical Flow Guide |
| Software | Integrated Windows-Based Data Acquisition, Real-Time Curve Plotting, Automated Report Generation (PDF/Excel), ASTM/ISO-Compliant Data Logging with Timestamped Audit Trail |
| Brand | MOTIS |
|---|---|
| Model | TPP |
| Origin | Shanghai, China |
| Compliance | NFPA 1971, ASTM D4018, GB 8965.1–2009, ISO 12749 |
| Heat Source | Dual Meker burners (38 mm, 5/16″ orifice) + 9× T150 quartz IR tubes |
| Total incident heat flux | 83 kW/m² ± 2 kW/m² |
| Radiant flux range | 13–40 kW/m² ± 4 kW/m² |
| Convection source | 800–1200 BTU/h per burner |
| Calibrated water-cooled heat flux sensor | 0–100 kW/m², response <200 ms, emissivity >0.95 |
| Data acquisition | 20 Hz (50 ms interval), 0.1 °C resolution, ±0.75 °C accuracy, cold-junction compensation |
| Gas control | Rotameter (±2% accuracy, >3 L/min), pressure regulator (0–15 psi), quarter-turn shutoff valve |
| Brand | MOTIS |
|---|---|
| Model | CFRT |
| Application | Fire resistance testing of low-voltage power cables (≤ 0.6/1.0 kV) |
| Compliance | GB/T 19216.11 (equivalent to IEC 60331-11) |
| Ignition Source | AGF propane ribbon burner (500 mm length, 15 mm nominal width, triple-row 1.32 mm diameter orifices) |
| Temperature Calibration | Omega 1.5 mm sheathed thermocouple |
| Gas Control | Imported mass flow controllers (accuracy ≥ ±1.5%) |
| Air–Fuel Mixing | Venturi-type premixing system |
| Voltage Control | Programmable via PC interface or front-panel adjustment |
| Continuity Monitoring | 0.25 A DC test current per conductor, LED-based real-time circuit integrity indication |
| Data Acquisition | Digital multichannel logging of voltage, current, gas flow, air flow, and thermocouple temperature |
| Safety Protection | D-II type fuse per GB 13539.5 (2 A), imported miniature circuit breakers per test circuit |
| Flame Stabilization | Automatic closed-loop control of propane/air ratio for stable 750 °C or 950 °C flame profile |
| Software Features | Standard-compliant report generation, pre-test parameter configuration (cable specs, standard selection, max duration), audit-trail-capable data logging, calibration history management (≥10 min stabilized acquisition) |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | NFP-1 |
| Compliance | NFPA 701 (2004 & 2009 Ed.), Test Method 1 |
| Burner Type | Meker Burner |
| Heat Output | 10,500 BTU/hr |
| Ignition | Automatic spark ignition |
| Burn Duration | Fixed 20 s ± 0.1 s |
| Timer Resolution | 0.1 s |
| Sample Holder | Standard ASTM/NFPA-compliant specimen clamp |
| Max Fabric Areal Density | 700 g/m² (21 oz/yd²) |
| Chamber Construction | Calcium silicate board lined with stainless steel exterior |
| Configuration | Open-top vertical combustion chamber |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | RFS |
| Standards Compliance | ASTM E162, ASTM E365, ASTM D3675 |
| Radiant Panel Dimensions | 300 × 460 mm |
| Reflector Surface | 305 × 457 mm, Porous Cement |
| Max Reflector Temp | 815 °C |
| Calibration Burner | Methane (95% purity, 20 L/min @ 150 mbar) |
| Pilot Burner | Acetylene (0.5 L/min @ 150 mbar) |
| Propane Burner | 1.0 L/s @ 20 mbar |
| Compressed Air Supply | 50 L/s @ 700 Pa water column |
| Exhaust Airflow Velocity | 0.5 m/s ±0.05 m/s |
| Black-Body Temperature Control Range | 180–230 °C (±5 °C accuracy) |
| Heat Flux Measurement Range | 0–100 kW/m² (±10% full scale, Schmidt-Boelter type) |
| Data Acquisition | GPIB/USB interface DAQ system with 19" touchscreen control unit |
| Frame Dimensions | 1850 H × 700 D × 1250 L mm |
| Electrical Supply | 220 V AC, 60 Hz, 12 A |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BFT |
| Pricing | Available Upon Request |
| Compliance | ASTM D4151 |
| Construction | Stainless Steel Enclosure with Tempered Glass Viewing Window |
| Ignition Source | No. 18 Needle Burner (Adjustable Flame Height) |
| Timing Resolution | 0.01 s |
| Accessories | Standardized Brushing Device, Sample Holder Assembly, Stainless Steel Specimen Clamps |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SCT |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Model | VFT |
| Standard Compliance | ISO 15025, AQ 6103–2007 |
| Ignition Source | Propane burner |
| Ignition Duration | Adjustable (default 10 s) |
| Sample Orientation | Vertical |
| Measured Parameters | Afterflame time, afterglow time, char length |
| Burner Control | Stepper motor–actuated angular positioning for bottom-edge and edge ignition |
| Display | Integrated LCD interface |
| Power Supply | 220 V, 50 Hz |
| Ambient Conditions | 20 ± 2 °C, 65 ± 5 % RH |
| Dimensions (W × H × D) | 410 × 900 × 380 mm |
| Gas Supply | Propane |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | GCF |
| Compliance | GB/T 29416–2012 Annex C, BS 8414 |
| Temperature Control | Programmable controller with standardized temperature ramp profile |
| Test Duration | 24 h continuous monitoring |
| Thermocouple Configuration | Internal furnace thermocouples + surface-mounted sample thermocouples |
| Data Logging | Real-time temperature display and curve plotting |
| Pass/Fail Criteria | Based on thermal trajectory divergence (sample center temperature vs. furnace ambient temperature) |
| Software Functionality | Automated test execution, time-synchronized thermal data acquisition, and smoldering propensity classification per GB/T 29416–2012 |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | IEC 60754-1&2 |
| Compliance | IEC 60754-1 Ed. 2.0 b:1994, IEC 60754-2 Ed. 1.0 b:1991, GB/T 17650 |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | CWFP |
| Applicable Standards | NFC 32-070 (France), UL 2556 |
| Heating Source | Electric Furnace + Dual Butane Burners |
| Sample Mounting | Vertically Suspended Cable |
| Smoke Duct | PTFE-Coated, Rotatable with Three 120° Ventilation Orifices |
| Ignition System | Electric Spark-Ignited Butane Burners with V-Shaped Wind Shield |
| Airflow Control | Variable-Frequency Fan + Adjustable Top-Mounted Damper + Anemometer |
| Calibration | Standard Radiant Rod for Furnace Power Verification |
| Chamber Construction | Integrated Combustion Test Enclosure with Forced-Air Ventilation |
| Compliance Support | Designed for GLP-aligned test execution and traceable calibration protocols |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Relia-Burn |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SCF |
| Compliance | ASTM E108, UL 790, NFPA 256, IEC 61730-2 Annex A |
| Test Chamber Dimensions (L×W×H) | 1020 × 1000 × 1473 mm |
| Roof Deck Substrate | Plywood, 1300 × 1000 × 120 mm |
| Non-combustible Backstop Panel | Stainless steel, installed at rear end of test deck |
| Adjustable Fan-shaped Deflector Plate | 1440 × 940 mm, stainless steel, angle-adjustable |
| Eave Simulator Assembly | 330 × 2130 × 584 mm, non-combustible board mounted at front frame |
| Airflow Velocity | 19 ± 8 km/h (5.5 ± 2.2 m/s), monitored via calibrated anemometer |
| Exhaust Duct | Stainless steel, 2130 × 762 × 3000 mm, equipped with honeycomb flow straightener, guide vanes, and adjustable turbulence plates |
| Fan | 220 V, 50 Hz, three-phase, reverse-flow capable, 0–100% infinitely variable speed control, min. airflow 300 m³/min |
| Gas Burner | 1.12 m long × 60.3 mm OD, linear slit (12.7 mm wide × 0.91 m long), heat output Class A/B: 21,000–22,000 Btu/min (369–387 kWh) for 10 min |
| Class C | 18,000–19,000 Btu/min (316–334 kWh) for 4 min |
| Burner Surface Temperature | 880 ± 10 °C |
| Automatic Ignition System | High-voltage electrode ≥1.8 kVp |
| Mass Flow Control | Precision thermal mass flow meters for repeatable gas delivery per test class |
| Data Acquisition | NI-based LabVIEW system with 16-bit thermocouple input, 16-bit analog input, digital I/O, 12-bit analog output, 4/8-slot chassis, real-time & Ethernet modules |
| Sample Support | Rotatable metal mesh tray with load-bearing capacity for standard PV modules (up to 2.0 m length) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SFT |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | CTA |
| Air Flow Range | 0–3 L/min (digital display, ±0.1 L/min resolution) |
| Temperature Control | Dual-mode PID (programmable ramp & single-point setpoint) |
| Max Furnace Temp | 1100 °C with over-temperature cutoff |
| Furnace Type | Openable quartz tube furnace with imported thermocouple-based heating system |
| Auxiliary Instruments | Magnetic stirrer, pH meter, conductivity meter |
| Filtration | Activated carbon + silica gel dual-column air filter |
| Standards Compliance | GB/T 17650.1–2, IEC 60754-1/2:1994, EN 50305, BS 6853 Annex B |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UL94-X |
| Chamber Volume | >0.75 m³ |
| Interior Finish | Matte Black |
| Viewing Window | Large Transparent Observation Port |
| Burner Angle Adjustment | 0°, 20°, 45° |
| Ignition Source | Bunsen Burner (ASTM D5025 Compliant) |
| Flame Geometry | Fan-shaped Burner (ASTM D4986 Compliant) |
| Gas Flow Control | Rotameter + High-Precision Pressure Regulator |
| Exhaust System | Top-mounted Forced Ventilation |
| Optional Accessory | Burner Calibration Kit (ASTM D5207 Compliant) |
| Standards Supported | UL 94 HB/V-0/V-1/V-2/5VA/5VB/VTM-0/VTM-1/VTM-2/HF-1/HF-2/HBF |
| Referenced Standards | IEC 60695-11-10, IEC 60695-11-20, ISO 1210, ISO 9770, ISO 9772, ISO 9773, GB/T 2408, GB/T 5169.17, GB/T 8332 |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | VF-2 |
| Compliance | CA TB 117 (Sec. A & B), CPAI 84 (Wall & Top), FAA FAR 25 App. F Part I, Boeing BSS 7230, Airbus AITM 2.0002, ASTM D6413 |
| Ignition Source | ASTM D5025-compliant Bunsen burner |
| Flame Application | Motorized lateral burner movement |
| Timing Resolution | 0.1 s |
| Chamber Construction | Stainless steel with transparent quartz side viewport |
| Sample Holders | Interchangeable stainless steel fixtures for multi-standard adaptability |
| Control Mode | Fully automated flame positioning and timing sequence |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | NES 713 |
| Compliance Standard | NES 713 (Naval Engineering Standard) |
| Operating Temperature | 800 °C |
| Chamber Volume | V m³ (user-specified per configuration) |
| Sample Mass | 100 g (standard test mass) |
| Toxicity Index Calculation | Σ(C₈ᵢ / Cfᵢ), i = 1 to n |
| Observation Window | Reinforced PTFE-coated polycarbonate viewport |
| Exhaust Control | Timer-actuated automatic purge mode |
| Test Modes | Manual and programmable automatic cycle |
| Chamber Lining | PTFE-bonded stainless steel interior |
| Door Mechanism | Positive-seal dual-latch system |
| Ignition System | Electric spark ignition with auto-shutoff |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UK-1 & UK-2 |
| Compliance | BS 5852:2006, UK Furniture and Furnishings (Fire) (Safety) Regulations 1988 (as amended), CFR 1634 |
| Chamber Dimensions (UK-1) | 450 × 300 × 150 mm |
| Chamber Dimensions (UK-2) | 450 × 450 × 300 mm |
| Construction | Full stainless steel frame and test fixture |
| Ignition Sources | Standard smoldering cigarette (ISO 12403-1), No. 0–No. 7 calibrated ignition sources |
| Included Accessories | Certified standard polyurethane foam (density 25 ± 1 kg/m³), standardized timber crib (ASTM E1321), stainless steel mesh screen (aperture ≤ 1 mm), stainless steel ignition tube, precision-cut stainless steel template for specimen positioning |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UL94-X |
| Compliance | UL 94 (HB, V-0/V-1/V-2, 5VA/5VB, VTM-0/1/2, HF-1/HF-2/HBF) |
| Chamber Volume | ≥0.75 m³ |
| Interior Finish | Matte Black |
| Viewing Window | Extra-Large Tempered Glass |
| Burner Adjustment | 0°, 20°, 45° |
| Gas Supply | Precision Regulated Propane or Methane |
| Flow Control | Rotameter with ±1% Full-Scale Accuracy |
| Pressure Regulation | High-Accuracy Dual-Stage Pressure Reducer |
| Burner Types | Bunsen (ASTM D5025), Ribbon (ASTM D4986) |
| Exhaust System | Top-Mounted Forced Ventilation |
| Optional | ASTM D5207 Burner Calibration Kit |
| Standards Supported | UL 94, IEC 60695-11-10/-20, ISO 1210/9770/9772/9773, GB/T 2408/5169.17/8332 |
| Brand | MOTIS |
|---|---|
| Model | 5659-2 |
| Conical Heater Heat Flux Range | 10–70 kW/m² |
| Shield Shutter | Motorized Radiation Blocker for Pre-Test Isolation |
| Compliance | ISO 5659-2 (Fire Tests — Reaction to Fire Tests — Part 2: Room/Corner Test) |
| Origin | Jiangsu, China |
| Distribution Type | Authorized Distributor |