| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MicroMR02-025V |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.05 ± 0.025 T |
| Field Homogeneity | 300 ppm over 25 mm × 25 mm × 35 mm |
| Field Stability | < 500 Hz/hour |
| Temperature Control Range | 25–35 °C (nonlinear precision thermostatic control), accuracy ±0.05 °C |
| RF Frequency Range | 2–30 MHz |
| Frequency Resolution | 0.1 Hz |
| RF Peak-to-Peak Output Power | >100 W, linearity distortion <0.3% |
| Probe Coil Diameter | 25 mm |
| Effective Sample Volume | Ø25.4 mm × H35 mm |
| Power Supply | 220 V, 50 Hz |
| Operating Ambient | 22–28 °C, 30–70% RH |
| Dimensions (L×W×H) | Magnet Cabinet: 410 × 450 × 500 mm |
| RF Cabinet | 450 × 90 × 410 mm |
| Spectrometer Unit | 425 × 177 × 480 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MicroMR06-040V-P-4 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnet Type | Permanent Magnet |
| Larmor Frequency | 6.17 MHz ± 0.2 MHz |
| Sample Cavity Dimensions | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Homogeneous Zone | Ø38.1 mm × H80 mm |
| Maximum Sample Length | 1.5 inches (38.1 mm) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Mode |
| Magnet Type | Permanent Magnet |
| Operating Frequency | 6.17 MHz ± 0.2 MHz |
| Sample Cavity Dimensions | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Homogeneity Zone | Ø38.1 mm × H80 mm |
| Max Sample Size | 1.5-inch rock core |
| Key Applications | Porosity, Permeability, Fluid Saturation, Movable Fluid Saturation, Pore Size Distribution, T₁–T₂ & D–T₂ 2D NMR Spectroscopy |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MicroMR06-040V-P-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnet Type | Permanent Magnet |
| Larmor Frequency | 6.17 MHz ± 0.2 MHz |
| Sample Cavity Dimensions | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Homogeneity Region | Ø38.1 mm × H80 mm |
| Max Core Diameter | 1.5 inches |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnet Type | Permanent Magnet |
| Larmor Frequency | 6.17 MHz ± 0.2 MHz |
| Effective Uniform Field Region | Ø38.1 mm × H80 mm |
| Max Sample Dimension | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Application Scope | Rock Core, Cuttings, Irregular & Standard Cylindrical Samples |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MicroMR06-040V-P2 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Magnet Type | Permanent Magnet |
| Operating Larmor Frequency | 6.17 MHz ± 0.2 MHz |
| Sample Cavity Dimensions | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Homogeneous Zone | Ø38.1 mm × H80 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MicroMR12-025V |
| Instrument Type | Low-Field NMR Analyzer |
| Operating Frequency | 12 MHz (corresponding to ~0.28 T static magnetic field) |
| Magnet Type | Permanent Magnet |
| Probe Coil Diameter | 25 mm |
| Effective Sample Volume | Ø25.4 mm × H35 mm |
| Sample Compatibility | Solid–Liquid Dual-Mode |
| Optional Upgrade | Diffusion-Weighted NMR (D-T2, D-T1-T2) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MRCL-110 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Analyzer |
| Sample Type | Solid–Liquid Combined (Full-Diameter Rock Cores) |
| Operating Frequency | 6.2 MHz |
| Maximum Core Length | 1 m |
| Maximum Core Diameter | 115 mm |
| Minimum Longitudinal Resolution | 1 cm |
| Primary Measurements | T₁ and T₂ Relaxation Spectra, T₁–T₂ Two-Dimensional Correlation Spectroscopy |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | NM-PQ001 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Magnetic Field Strength | 0.28 T ± 0.03 T |
| Sample Cavity Dimensions | Ø40 mm × H60 mm |
| Magnet Homogeneity | ≤40 ppm |
| Repeatability (11 Replicates) | ≤0.5% RSD |
| Oil Content Range | 1–100 wt% |
| Water Content Range | 2–10 wt% |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Field Strength | 0.5 T ± 0.03 T |
| Max Sample Dimensions | Ø68 mm × H60 mm |
| Sample Compatibility | Solid-Liquid Dual-Mode (in vivo small animals & ex vivo tissues) |
| Imaging Modes | T1-weighted, T2-weighted, Water-Fat Separation |
| Spatial Resolution | Sub-millimeter (typical in-plane resolution ≤ 0.5 mm) |
| Scan Time | ~2 minutes per standard protocol |
| Regulatory Compliance | CE-marked for research use only (RUO), compliant with ISO/IEC 17025 calibration traceability framework for NMR signal stability |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NM21-060H-I |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Imaging Analyzer |
| Sample Type | Solid-Liquid Hybrid Samples |
| Magnet Type | Permanent Magnet |
| Field Strength | 0.6 T ± 0.03 T |
| Homogeneity | ≤30 ppm over 60 mm DSV |
| Sample Weight Range | 1–350 g (mice, rats, excised tissues, contrast agents, magnetic nanoparticles) |
| Imaging Modes | T1-weighted, T2-weighted, Proton Density-weighted, Water-Fat Suppressed Imaging |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | NM42-060H-1 |
| Instrument Type | Low-Field NMR Spectrometer |
| Sample Compatibility | Solid-Liquid Hybrid (ex vivo tissues & live rodents, 1–350 g) |
| Magnet Type | Permanent Magnet |
| Field Strength | 1 T ± 0.05 T |
| Homogeneity | ≤30 ppm over DSV |
| Imaging Modes | T1-weighted, T2-weighted, Proton Density-weighted, Water-Fat Suppressed Imaging |
| Application Domain | Preclinical Metabolic Disease Research |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode (Ex Vivo Tissues & Live Rodents, 1–350 g) |
| Magnet Type | Permanent Magnet |
| Field Strength | 1 T ± 0.05 T |
| Magnetic Homogeneity | ≤30 ppm over 60 mm DSV |
| Spatial Resolution | <100 µm (in-plane, optimized conditions) |
| Imaging Sequences | T1-weighted, T2-weighted, Proton Density-weighted, Fat-Suppressed, Diffusion-Weighted (optional) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-I-1 |
| Instrument Type | Low-Field NMR Imager |
| Sample Compatibility | Solid and Liquid Samples (in vivo rodents, ex vivo tissues, contrast agents, magnetic nanoparticles) |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 1.0 T ± 0.05 T |
| Magnetic Field Homogeneity | ≤30 ppm over 60 mm DSV |
| Sample Weight Range | 1–350 g (mice, rats, excised tissues) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | NM42-060H-I-2 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Imaging System |
| Sample Type | Solid-Liquid Dual Compatibility |
| Magnet Type | Permanent Magnet |
| Field Strength | 1.0 T ± 0.05 T |
| Magnet Homogeneity | ≤30 ppm over Ø60 mm DSV |
| Supported Sample Mass Range | 1–350 g (mice, rats, excised tissues) |
| RF Coil Apertures | Ø60 / Ø45 / Ø35 / Ø30 / Ø25 mm |
| Max Reconstruction Matrix | 512 × 512 × 128 |
| Integrated Anesthesia & Respiratory Monitoring | Yes |
| Temperature-Controlled Animal Bed | Yes |
| Pulse Sequence Flexibility | Graphical GUI + Python API for custom sequence development |
| Data Throughput Architecture | Gigabit Ethernet-based real-time acquisition with <10⁻⁹ bit error rate |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | NM42-060H-I |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Imaging System |
| Sample Type | Solid-Liquid Dual-Mode (ex vivo tissues, live rodents: 1–350 g) |
| Magnet Type | Permanent Magnet |
| Field Strength | 1.0 T ± 0.05 T |
| Magnetic Homogeneity | ≤30 ppm over 60 mm DSV |
| Spatial Resolution | Sub-millimeter (typical in-plane: ≤150 µm, slice thickness: ≥0.5 mm) |
| Imaging Sequences | T1-weighted, T2-weighted, Proton Density-weighted, Fat/Water Separation (Dixon), Diffusion-Weighted Imaging (DWI), MR Angiography (MRA) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-I |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Imaging System |
| Sample Type | Solid-Liquid Dual-Mode (In Vivo Mice, Ex Vivo Tissues, Contrast Agents, Magnetic Nanoparticles) |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 1.0 T ± 0.05 T |
| Magnet Homogeneity | ≤30 ppm over Ø60 mm DSV |
| Imaging Matrix Support | Up to 512 × 512 × 128 |
| RF Coil Options | φ25 mm / φ30 mm / φ35 mm / φ45 mm / φ60 mm Dedicated Animal Body Coils |
| Integrated Anesthesia & Respiratory Monitoring | Yes |
| Temperature-Controlled Animal Bed | Yes |
| Pulse Sequence Flexibility | Graphical GUI + Python Scripting Support |
| Data Throughput Architecture | Gigabit Ethernet-Based Real-Time Acquisition Platform |
| Bit Error Rate | One Order of Magnitude Lower Than Conventional Open-Source Spectrometers |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NMI20 |
| Instrument Type | Low-Field NMR Relaxometer & Imager |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Larmor Frequency | 21.3 MHz |
| Probe Coil Diameter | 15 mm |
| Effective Sample Volume | Ø12.5 mm × H30 mm |
| Relaxation Analysis | T₁, T₂, T₂* quantification |
| Imaging Modes | Proton Density, T₁-weighted, T₂-weighted |
| Contrast Agent Analysis | r₁ and r₂ relaxivity determination |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NMI20 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Mode |
| Magnet Type | Rare-Earth Permanent Magnet |
| Probe Inner Diameter | 40 mm |
| Core Functionality | T₁/T₂ Relaxometry & MRI (Proton Density, T₂-Weighted, T₁-Weighted) |
| Pulse Sequences | FID, SE, CPMG, SEG-CPMG, IR, MSE, FSE |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NMI20 |
| Instrument Type | Low-Field NMR Analyzer & Imager |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Magnet Type | Rare-Earth Permanent Magnet |
| Probe Inner Diameter | 40 mm |
| Core Functionality | T₁/T₂ Relaxometry + 2D MRI (Arbitrary Slice Orientation, Variable Slice Thickness) |
| Pulse Sequences | FID, Spin Echo (SE), CPMG, SEG-CPMG, Inversion Recovery (IR), Fast Spin Echo (FSE), Multi-Spin Echo (MSE) |
| Software Platform | Proprietary 2nd-Generation NMR Console & Imaging Suite |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual Mode |
| Operating Principle | Pulsed Fourier Transform NMR |
| Magnet Type | Rare-Earth Permanent Magnet |
| Probe Inner Diameter | 60 mm |
| Sample Mass Range | 1–120 g |
| Minimum Sample Volume | ≥1 mL |
| Imaging Modes | Proton Density, T₂-Weighted, T₁-Weighted |
| Core Applications | Oil/Water Content Quantification, Water Binding State Analysis, Spatial Distribution Mapping of Moisture & Lipids |
| Software Sequences | FID, Spin Echo (SE), CPMG, SEG-CPMG, Inversion Recovery (IR) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NMI20 Series |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Compatible |
| Operating Mode | Pulsed Fourier Transform |
| Minimum Sample Volume | ≥1 mL |
| Sample Mass Range | 1–120 g |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NMI20-040V-I |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NMI20-060V-I |
| Instrument Type | Low-Field NMR Spectrometer & Imager |
| Sample Compatibility | Solid-Liquid Dual-Mode |
| Bore Diameter | 60 mm |
| Minimum Sample Volume | ≥1 mL |
| Sample Mass Range | 1–120 g |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual Mode |
| Operating Principle | Pulsed Fourier Transform NMR |
| Magnet Type | Rare-Earth Permanent Magnet |
| Probe Inner Diameter | 40 mm |
| Core Functionality | T₁/T₂ Relaxometry & MRI (Proton Density, T₁-Weighted, T₂-Weighted Imaging) |
| Software Platform | Proprietary 2nd-Generation NMR Console & Imaging Suite |
| Compliance Context | Designed for GLP-aligned laboratory workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Portable NMR Logger |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnet Frequency | 6 MHz ± 0.05 MHz |
| Magnet Homogeneity | ≤200 ppm (over Ø40 mm × H80 mm uniform region) |
| Magnet Stability | <80 µs drift over 24 h |
| Probe Compatibility | Customized for core plugs up to 1.5″ length and cuttings |
| Key Applications | Porosity, Permeability, Fluid Saturation (S<sub>o</sub>, S<sub>w</sub>), Bound/Free Fluid Ratio, T<sub>2</sub> & T<sub>1</sub>–T<sub>2</sub> Mapping |
| Brand | NIUMAG |
|---|---|
| Model | PQ-001 |
| Instrument Type | Low-Field NMR Analyzer |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 T ± 0.03 T |
| Magnetic Field Homogeneity | ≤30 ppm |
| Sample Tube Diameter | Ø8.5 mm |
| Sample Height | 20 mm |
| Probe Coil Diameter | 18 mm |
| Sample Volume | 2–6 mL |
| Sample Compatibility | Solid–Liquid Dual-Mode |
| Origin | Jiangsu, China |
| Manufacturer Status | Authorized Distributor |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Spectrometer |
| Model | PQ001 |
| Sample Compatibility | Solid-Liquid Dual-Phase (Intact Oilseeds & Pressed Cake) |
| Magnetic Field Strength | 0.50 ± 0.01 T |
| Sample Tube Dimensions | Ø16 mm × H40 mm |
| Magnet Homogeneity | ≤30 ppm |
| Oil Content Range | 1–100 wt% |
| Moisture Content Range | 2–10 wt% |
| Repeatability (11 Replicates) | ≤0.5% RSD for Oil Content |
| Measurement Principle | Time-Domain Pulsed NMR (T₂ Relaxation & FID Signal Separation) |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Larmor Frequency | 21.3 MHz |
| Probe Coil Diameter | 25 mm |
| Effective Sample Volume | Ø25 mm × H35 mm |
| Compliance | GB/T 6504–2008 (Fiber Oil Content) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | PQ001-Fiber Suspension Dispersion |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Analyzer |
| Sample Type | Solid–Liquid Hybrid Systems |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 T ± 0.03 T |
| Sample Tube Dimensions | Ø24.2 mm × H25 mm |
| Measurement Time | ≤120 s per test |
| Software Architecture | Integrated GUI with Real-Time T₂ Relaxometry |
| Compliance Framework | Designed for GLP-compliant environments |