| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Model | QMR06-090H-3 |
| Sample Compatibility | Solid-Liquid Dual-Phase (Live Small Animals) |
| Magnetic Field Strength | ~0.06–0.09 T (Typical for Benchtop LF-NMR) |
| Measurement Time per Sample | 60–180 s |
| Output Parameters | Fat Mass, Lean Body Mass, Total Body Water (TBW), Fat Fraction (%), Lean/Fat Ratio |
| Compliance | Designed for GLP-aligned preclinical research workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode (In Vivo Conscious Small Animals & Excised Tissues) |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Animal Weight Range | 10–100 g (in vivo) |
| Excised Tissue Range | 0.1–6 g |
| Measurement Time | <80 s per acquisition |
| Magnet Type | Permanent Magnet |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Instrument Manufacturer (not distributor) |
| Product Category | Domestic |
| Model | QMR06-090H-PRO |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode (Live Small Animals & Excised Tissues) |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.15 ± 0.015 T |
| Magnetic Homogeneity | ≤300 ppm over DSV |
| Sample Weight Range | 0.1–6 g (excised tissues) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Sample Capacity | 0.1–6 g (ex vivo tissue) or 10–800 g (live small rodents) |
| Measurement Mode | Solid-Liquid Dual-State NMR Relaxometry |
| Acquisition Time | ≤80 s per quantitative assay |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | QMR06-090H-PRO-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Mode (Live Small Animals & Excised Tissues) |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Sample Weight Range | 10–800 g (live rodents), 0.1–6 g (excised tissues) |
| Analysis Time | <80 s per measurement |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | QMR06-090H-PRO-5 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Mode (Live Small Animals & Excised Tissues) |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Sample Weight Range | 10–800 g (live rodents), 0.1–6 g (excised tissues) |
| Measurement Time | <80 s per acquisition |
| Magnet Type | Permanent Magnet |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | QMR06-090H-PRO-1 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Mode |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Sample Weight Range | 0.1–6 g (ex vivo tissue) |
| Magnet Type | Permanent Magnet |
| Analysis Time | <80 s per measurement |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QMR06-090H-PRO-4 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase (Live Small Animals) |
| Magnet System | Permanent Magnet |
| Dedicated Probe | Mouse Body-Composition Optimized RF Coil |
| Software | NIUMAG Proprietary Mouse Body Composition Analysis Suite |
| Regulatory Compliance | Designed for GLP-Compliant Preclinical Research Environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Full-Diameter Core Analyzer-1 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Spectrometer |
| Sample Type | Solid-Liquid Dual-Phase (Intact Shale Cores under In-Situ Pressure) |
| Operating Frequency | 6.2 MHz |
| Minimum Echo Time (TE) | 0.1 ms |
| Longitudinal Spatial Resolution | 1 cm |
| Maximum Core Length | 3.4 cm |
| Maximum Core Diameter | 115 mm |
| Relaxometry Modes | T₁, T₂, and T₁–T₂ Two-Dimensional Correlation Spectroscopy |
| Brand | NIUMAG |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SMARtracer™ |
| Instrument Type | Low-Field NMR Relaxometer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Operating Nuclei | ¹H, ¹⁹F |
| Frequency Range | 10 mHz – 10 kHz |
| Temperature Control Range | −140 °C to +140 °C (0.1 °C resolution) |
| Relaxation Time Range | Sub-millisecond to several seconds |
| Cryogen-Free Operation | Yes |
| Automation Level | Fully Automated NMRD Profile Acquisition |
| Brand | NIUMAG |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported Low-Field NMR Analyzer |
| Model | SPINMASTER FFC2000 1T C/DC |
| NMR Frequency Range (¹H) | 0.1 kHz – 42.6 MHz |
| Temperature Control Range | −140 °C to +140 °C (0.1 °C resolution) |
| Sample Compatibility | Solid–Liquid Hybrid, Colloids, Liquid Crystals, Porous Media, Polymers, Biological Tissues |
| Multinuclear Capability | ¹H, ²H, ¹³C, ¹⁹F, ⁷Li |
| Relaxation Time Range | Sub-millisecond to several seconds (T₁ and T₂) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Analyzer |
| Sample Type | Solid-Liquid Hybrid |
| Operating Mode | Pulsed Fourier Transform (PFT) |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Typical Measurement Time | ≤2 min per sample |
| Core Techniques | T₁/T₂ Relaxometry, NMR Imaging (MRI), FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₂ Signals |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | VTMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Compatible |
| Operating Mode | Pulsed Fourier Transform |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Effective Sample Detection Volume | Ø8.5 mm × H20 mm |
| Temperature Control Range | Ambient to 130 °C (Standard) / Ambient to 180 °C (Optional) |
| Measurement Time | ≤2 min per sample |
| Imaging Capability | Optional |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR Series |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Operating Mode | Pulsed Fourier Transform |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₁/T₂ & Weak-Signal Detection |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₂/Weak-Signal Detection |
| Primary Measurement Modes | T₁ & T₂ Relaxometry, Diffusion-Weighted Analysis, MR Imaging (optional) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR- |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Compatible |
| Operating Mode | Pulsed Fourier Transform |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Effective Sample Detection Volume | Ø8.5 mm × H20 mm |
| Temperature Control Range | RT to 130 °C (Standard) / RT to 180 °C (Optional) |
| Imaging Capability | Optional |
| Measurement Time | ≤2 min per sample |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Domestic/Imported | Domestic |
| Model | VTMR-MRI |
| Instrument Type | NMR Imaging System |
| Sample Compatibility | Solid-Liquid Dual-State |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Magnet Type | Permanent Magnet |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₂/Weak-Signal Samples |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | VTMR-nmr |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Magnet Type | Permanent Magnet |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| MRI Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Pulse Sequence for Short-T₂ Signal Acquisition |
| Primary Measurement Modes | T₁ & T₂ Relaxometry, Diffusion-Weighted Analysis, Spatially Resolved Imaging (with optional gradient set) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR-Tg |
| Instrument Type | Low-Field NMR Spectrometer |
| Sample Type | Solid-Liquid Dual-Mode |
| Operating Mode | Pulsed Fourier Transform |
| Sensitivity | Signal-to-Noise Ratio (SNR) Optimized |
| Resolution | Sub-millimeter Spatial Resolution (Imaging Mode, Optional) |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.05 T |
| Effective Sample Volume | Ø8.5 mm × H20 mm |
| Temperature Control Range | Ambient to 130 °C (Standard) |
| Imaging Capability | Optional MRI-Enabled Configuration |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Model | VTMR20-010V |
| Sample Compatibility | Solid-Liquid Hybrid Systems |
| Operating Field Strength | < 0.5 T |
| Measurement Principle | Transverse Relaxation Time (T₂) Distribution Analysis |
| Temperature Simulation Range | Ambient to 120 °C (integrated heating module) |
| Data Acquisition Mode | CPMG pulse sequence |
| Key Output Parameters | T₂ distribution spectra, bound/free fluid ratio, peak shift quantification, area under curve (AUC) change rate |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | VTMR20-010V |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Compatibility |
| Operating Mode | Pulsed Fourier Transform |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Effective Sample Volume | Ø8.5 mm × H20 mm |
| Temperature Control Range | Ambient to 130 °C (standard), extended options available |
| Brand | NIUMAG |
|---|---|
| Model | VTMR20-010V / VTMR20-010V-I |
| Magnet Type | Permanent Magnet |
| Field Strength | 0.5 ± 0.05 T |
| Temperature Control Range | Ambient to 130 °C (standard) |
| Sample Compatibility | Solid–Liquid Hybrid Systems |
| Core Techniques | T₁/T₂ Relaxometry, MRI (optional), FLAT Pulse Sequence for Short-T₂ Signal Acquisition |
| Measurement Time | ≤2 min per sample |
| Application Domain | Crosslink Density Quantification, Hard/Soft Segment Ratio Analysis, Curing Kinetics Monitoring, Aging Evaluation, Interface Interaction Studies |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR20-010V-01 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid–Liquid Hybrid Samples |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.05 T |
| Temperature Control Range (Standard) | 25–130 °C |
| Optional Cryo/High-Temp Module | –100 to 200 °C |
| Measurement Time per Sample | ≤ 2 min |
| Detection Principle | Transverse Relaxation (T₂) Decay Analysis |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | VTMR20-010V-1 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Control Range | RT to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| Measurement Time per Sample | ~2 min |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | VTMR20-010V-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Hybrid |
| Magnet Type | Permanent Magnet |
| Static Magnetic Field Strength | 0.5 ± 0.05 T |
| Temperature Control Range (Standard) | 25–130 °C |
| Optional Cryo/High-Temp Module | –100 to 200 °C |
| Pulse Sequence | Modified Spin-Echo CPMG (MSE-CPMG) |
| Measurement Time | ≤2 min per sample |
| Detection Nucleus | ¹H |
| Applications | Crosslinking density, T₂ relaxation distribution, phase-separated water dynamics, polymer segment mobility quantification |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VTMR20-010V-3 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid–Liquid Hybrid Samples |
| Magnet Type | Permanent Magnet |
| Static Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Control Range | +20 °C to +130 °C |
| Optional Cryo–High-Temp Module | –100 °C to +200 °C |
| Imaging Capability | Optional |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR20-010V-4 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Phase Compatible |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₂ Signals |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR20-010V-5 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid–Liquid Hybrid Samples |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Control Range | 25–130 °C |
| Optional Cryo/High-Temp Module | –100 to 200 °C |
| Measurement Time per Sample | ≤2 min |
| Signal Source | Proton (¹H) Relaxation in Hydrated Membranes |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Model | VTMR20-010V-6 |
| Sample Compatibility | Solid-Liquid Hybrid (Hydrated PEMs) |
| Operating Field Strength | ~0.5 T (Typical for VTMR Series) |
| Temperature Control Range | –40 °C to +120 °C (Programmable, In Situ) |
| Measurement Principle | Transverse Relaxation (T₂) Distribution Analysis of Confined Water Protons |