| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | WZS-182 |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0.00–500 NTU |
| Resolution | 0.01 NTU (at low range), 0.1 NTU (mid), 1 NTU (high) |
| Operating Temperature | 5–35 °C |
| Accuracy | ±6% FS |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% FS / 30 min |
| Stability | ±0.5% FS / 30 min |
| Calibration Points | Up to 5 points (2, 20, 50, 200, 500 NTU) |
| Data Storage Capacity | 1000 records |
| Display | 5.7-inch color LCD |
| Ingress Protection | IP54 |
| Power Supply | DC 24 V (AC 100–240 V input adapter) |
| Dimensions & Weight | 189 × 282 × 84 mm, ~1.5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WZS-182E |
| Price | USD 980 (FOB Shanghai) |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0.00–9.99 NTU |
| Resolution | 0.01 / 0.1 / 1 NTU (auto-ranging) |
| Operating Temperature | 5–35 °C |
| Accuracy | ±6% of reading |
| Light Source | Tungsten-halogen lamp |
| Measurement Principle | Nephelometric (90° scatter) and Ratio nephelometric-scatter/transmission |
| Compliance | USEPA Method 180.1, HJ 1075–2019, JJG 880–2006 |
| Display | 5.7-inch color LCD with tactile keypad |
| Protection Rating | IP54 |
| Calibration Standards Included | Long-life turbidity standards at 20, 200, and 500 NTU |
| Data Storage | 1000 measurement records |
| Interface | RS-232 (for thermal printer), USB-B (for PC communication) |
| Software Support | Dedicated Leici turbidity data management software (Windows-compatible) |
| GLP Features | Audit-trail enabled timestamped records, user ID logging, calibration history, factory reset with zero & calibration value recovery |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | WZS-182E |
| Price | USD 865 (FOB Shanghai) |
| Instrument Type | Benchtop / Laboratory |
| Measurement Range | (0.00–9.99) NTU, (10.0–99.9) NTU, (100–500) NTU |
| Resolution | 0.01 / 0.1 / 1 NTU |
| Accuracy | ±6% of reading |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% FS / 30 min |
| Stability | ±0.5% FS / 30 min |
| Calibration Points | Zero + up to 5 points (2, 20, 50, 200, 500 NTU) |
| Display | 5.7-inch color LCD |
| Ingress Protection | IP54 |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | AC 100–240 V input |
| Dimensions (L×W×H) | 189 × 282 × 84 mm |
| Weight | ~1.5 kg |
| Light Source | Tungsten-halogen lamp (400–600 nm), compliant with USEPA Method 180.1 and HJ 1075-2019 |
| Measurement Principle | Nephelometric (90° scattered light) and Ratio (scattered + transmitted light) modes |
| Units | NTU, FNU, EBC |
| Modes | Standard, Average (multi-read averaging), Zero Calibration, Multi-point Calibration |
| Data Storage | 1000 measurement records |
| Interface | RS-232 (for thermal printer), USB-B (for PC communication via proprietary software) |
| Compliance | GLP-compliant data logging with timestamp, operator ID, calibration history, and audit trail support |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | WZS-182E |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | (0.00–9.99) NTU |
| Resolution | 0.01 NTU |
| Accuracy | ≤ ±6% |
| Repeatability | ≤ 0.5% |
| Light Source | Tungsten-halogen lamp |
| Compliance | EPA Method 180.1 & HJ 075-2017 |
| Measurement Principles | Nephelometric (90° scattering) and Ratio (scattering + transmission) modes |
| Units | NTU, FNU, EBC |
| Display | High-resolution LCD with intuitive UI |
| Calibration | Built-in standard curves + user-defined single/multi-point calibration |
| Environmental Operating Temperature | Ambient (10–30 °C) |
| Ingress Protection | IP54 |
| Included Accessories | Instrument host, 5 x standardized turbidity vials, long-life calibration standards (20–500 NTU) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | WZS-186 |
| Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0.000–2000 NTU |
| Resolution | 0.001 NTU (at lowest range) |
| Operating Temperature | 5–35 °C |
| Accuracy | ±6% FS |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% FS / 30 min |
| Stability | ±0.5% FS / 30 min |
| Calibration Points | Up to 7 points (2, 20, 50, 200, 500, 1000, 2000 NTU) |
| Data Storage Capacity | 2000 measurements |
| Display | 7-inch color TFT touchscreen |
| Protection Rating | IP54 |
| Interface | RS-232, USB |
| Power Supply | DC 24 V (AC 100–240 V input adapter) |
| Dimensions | 189 × 282 × 84 mm |
| Weight | ~1.5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | WZS-188 |
| Price | USD 1,160 (approx.) |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0.000–4000 NTU |
| Accuracy | ≤ ±6 % |
| Repeatability | ≤ 0.5 % |
| Stability | ≤ ±0.5 % FS |
| Zero Drift | ≤ ±0.5 % FS |
| Dimensions | 358 × 323 × 160 mm |
| Weight | 3 kg |
| Light Source | Tungsten Halogen Lamp |
| Compliance | EPA Method 180.1 |
| Calibration | Up to 7-point user calibration with factory restore function |
| Data Storage | 1000 measurement records |
| Interfaces | USB + RS-232 |
| GLP Support | Yes, with audit-ready timestamped data logging |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | WZS-188E |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | (0.000–9.999) NTU, (10.00–99.99) NTU, (100.0–999.9) NTU, (1000–4000) NTU |
| Resolution | 0.001 / 0.01 / 0.1 / 1 NTU |
| Accuracy | ±6% |
| Light Source | Tungsten-Halogen Lamp |
| Compliance | US EPA Method 180.1, HJ 1075–2019 |
| Measurement Principle | Nephelometric (90° scatter) and Scatter-Transmission dual-mode |
| IP Rating | IP54 |
| Display | 7-inch HD color capacitive touchscreen |
| Calibration Options | Single-point or multi-point |
| Units | NTU, FNU, EBC |
| Modes | Standard measurement, averaging mode (for dynamic suspension stabilization), auto-ranging |
| Data Management | Onboard storage, recall, deletion, USB export, RS-232 printer output |
| Software Interface | PC communication via dedicated software (USB) |
| GLP Support | Full audit trail, timestamped records, user ID logging, calibration history retention |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | WZS-190S |
| Price Range | USD 1,400–2,100 |
| Instrument Type | Benchtop / Laboratory |
| Measurement Range | 0–4000 NTU (tungsten lamp), 0–2000 NTU (860 nm LED) |
| Resolution | 0.001 NTU (lowest range) |
| Accuracy | ±6% FS |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% FS / 30 min |
| Stability | ±0.5% FS / 30 min |
| Light Sources | Dual-source — Tungsten lamp (400–600 nm, compliant with US EPA Method 180.1 & HJ 1075-2019), 860 nm LED (compliant with ISO 7027 & HJ 1075-2019) |
| Calibration Points | Up to 8-point (tungsten), up to 7-point (LED) |
| Data Storage Capacity | 2000 turbidity measurements per light source + 2000 verification records + 500 system logs + 4000 operation logs |
| Environmental Operating Conditions | 5–35 °C, ≤85% RH |
| Power Supply | AC 100–240 V input, DC 20 V output |
| Dimensions & Weight | 300 × 200 × 88 mm, ~1.5 kg |
| Protection Rating | IP54 |
| Compliance Standards | JJG 880–2006, HJ 1075–2019, ISO 7027:2016, US EPA Method 180.1 |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | WZT-701 |
| Price Range | USD 1,400 – 2,800 |
| Configuration | Online Continuous Monitoring |
| Measurement Range | 0.00–500.0 NTU |
| Resolution | 0.01 NTU (≤10 NTU), 0.1 NTU (>10 NTU) |
| Accuracy | ±10% FS |
| Repeatability | ≤2% |
| Zero Drift | ±0.5% FS / 30 min, ±1% FS / 24 h |
| Span Drift | ±5% FS / 24 h |
| MTBF | ≥720 hours |
| Enclosure Rating | IP65 |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Dimensions (W×H×D) | 160 × 160 × 110 mm |
| Weight | 5.0 kg |
| Output | Isolated 4–20 mA DC (user-configurable span/zero), RS-232 serial interface |
| Calibration | Single-point or two-point standard calibration |
| Alarm Functions | Programmable high/low limit alerts with latching logic |
| Data Retention | Non-volatile memory for settings and calibration history |
| Environmental Operating Range | 0–40 °C, <90% RH non-condensing |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WZT-701 |
| Product Type | Online Turbidimeter |
| Measurement Range | 0.00–500.0 NTU |
| Resolution | 0.01 NTU (≤10 NTU), 0.1 NTU (>10 NTU) |
| Accuracy | ±10% FS |
| Repeatability | ≤2% |
| Zero Drift | ±0.5% FS / 30 min, ±1% FS / 24 h |
| Span Drift | ±5% FS / 24 h |
| MTBF | ≥720 h |
| IP Rating | IP65 |
| Power Supply | AC 220 V ±10%, 50 Hz ±1% |
| Dimensions (W×H×D) | 160 × 160 × 110 mm |
| Weight | 5.0 kg |
| Output | Isolated 4–20 mA DC (configurable upper/lower limits) |
| Digital Interface | RS-232 |
| Calibration | Single-point or two-point standard calibration |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | WYL-3 |
| Price Range | USD 1,400 – 7,000 |
| Stress Measurement Range | 0–560 nm |
| Full-Wave Retardation Plate | 560 nm |
| Max Sample Dimensions | Width ≤ 440 mm, Height ≤ 240 mm, Length ≤ 440 mm |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GIR310 |
| Cooling Type | Uncooled Microbolometer |
| Measurement Method | Non-contact Passive Imaging |
| Primary Function | Optical Gas Imaging (OGI) & Radiometric Thermography |
| Detector Type | VOx Microbolometer |
| Spectral Band | 8–12 µm (LWIR), with Interchangeable Gas-Specific Bandpass Filters |
| Thermal Sensitivity (NETD) | ≤0.1 °C @ 30 °C |
| IR Resolution | 384 × 288 pixels |
| Temperature Range | –20 °C to +650 °C |
| Accuracy | ±3 °C or ±3% of reading (whichever is greater) |
| Frame Rate | 50 Hz ±1 Hz |
| Display | High-resolution articulating LCD with dual-band fusion capability |
| Gas Targets | SF₆, CH₄, NH₃, CFCs/HCFCs/HFCs (R-134a, R-410A, etc.) |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GIR310 |
| Price | USD 10,200 (FOB Beijing) |
| Spectral Response | Long-Wave Infrared (LWIR, 8–14 µm) |
| Detector Type | Uncooled Microbolometer Array |
| Application Class | Predictive Maintenance & Thermographic Survey |
| Measurement Method | Non-Contact Radiometric Imaging |
| Detector Cooling | Uncooled Operation |
| Display | High-Resolution OLED Viewfinder with Adjustable Dual-Band Fusion Mode |
| Connectivity | Integrated Wi-Fi 5 (802.11ac), USB-C Data Transfer, Real-Time Streaming to PC/Mobile |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GIR320 Plus |
| Price Range | USD 104,000–142,000 |
| Cooling Type | Cooled |
| Measurement Method | Non-contact |
| Application Type | Continuous Monitoring |
| Detector Type | Type-II Superlattice (T2SL) |
| Spectral Band | Mid-wave infrared (MWIR) |
| Spectral Range | 3.2–3.5 µm |
| Thermal Sensitivity (NETD) | ≤0.010 °C @ 25 °C |
| Infrared Resolution | 320 × 256 |
| Temperature Range | −40 °C to +350 °C |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater), calibrated per ISO 18434-1 |
| Frame Rate | 60 Hz (full frame) |
| Brand | LEUKOS |
|---|---|
| Model | DISCO |
| Type | Fiber-Pumped, Solid-State Hybrid Supercontinuum Source |
| Spectral Range | UV–NIR (350–2400 nm) |
| Repetition Rate | 2 kHz (externally triggered) |
| Timing Jitter | < 10 ns (RMS, at 2 kHz) |
| Pulse Energy | > 3 µJ per pulse |
| Beam Quality | Spatially Single-Mode (M² < 1.1) |
| Output Format | Free-space collimated beam (standard), optional fiber coupling (FC/APC or SMA) |
| Compliance | CE-marked, RoHS-compliant, Class 4 Laser Product (IEC 60825-1) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 85-SHG / 95-SHG |
| Core Technology | Gas Laser System (Argon Ion) |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LGN-212 |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LHP |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Core Technology | Gas Laser System |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-250A |
| Sensor Type | Silicon Photodiode |
| Accuracy (25 °C) | ±0.4% of full scale ±3 digits |
| Accuracy (0–55 °C) | ±0.6% of full scale ±3 digits |
| Range Selection | Auto-ranging across 3 scales |
| Linearity | ±0.05% |
| Display | Digital LCD, 0.5 s update in instantaneous mode |
| Power | One 9 V alkaline battery (150 h typical life) |
| Operating Environment | 0–55 °C, 0–95% RH (non-condensing) |
| Storage | −55–60 °C, 0–95% RH (non-condensing) |
| Dimensions | 14 × 7.7 × 3.8 cm |
| Weight | 0.26 kg |
| IP Rating | Rain- and dust-resistant (O-ring sealed enclosure) |
| Signal Averaging | 15 s moving average (~60 samples) |
| Input Interface | BNC connector for LI-COR radiation sensors |
| Calibration | User-entered sensor-specific calibration coefficient |
| Brand | LICHEN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | WSB Series |
| Price Range | USD 170 – 475 |
| Power Supply | WSB-1: 5×AA alkaline batteries (DC 1.5 V) or AC 220 V / 50 Hz |
| WSB-2 | AC 220 V / 50 Hz |
| Display | LCD |
| Whiteness Formula | Blue Light Whiteness WB = R₄₅₇ |
| Measurement Range | 0–199 |
| Aperture Diameter | WSB-1: Φ15 mm |
| WSB-2 | Φ30 mm |
| Zero Drift | ≤0.2 / 10 min |
| Indication Drift | ≤0.3 / 3 min |
| Repeatability Error | WSB-1: ≤0.2 |
| WSB-2 | ≤0.3 |
| Net Weight | WSB-1: 0.4 kg |
| WSB-2 | 2.1 kg |
| Dimensions | WSB-1: 70 × 220 × 75 mm |
| WSB-2 | 260 × 330 × 250 mm |
| Calibration Standard | Certified National White Reference Tile |
| Preheat Time | 30 seconds |
| Compliance | GB/T 2913, GB/T 5950, GB/T 8940.1, GB/T 12097, GB/T 13025.2 |
| Brand | Powerlase |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Sprout-10 |
| Output Power | >10 W |
| Wavelength | 532 nm |
| Spectral Purity | >99.9% |
| Beam Quality (M²) | 1.0–1.1 |
| Spatial Mode | TEM₀₀ |
| Beam Diameter | 2.3 mm ±10% |
| Beam Divergence | <0.5 mrad |
| Pointing Stability | <2 µrad/°C |
| Power Stability | <±0.25% RMS (24 h) |
| Intensity Noise (NET version) | <0.03% RMS |
| Laser Head Dimensions | 69 × 135 × 256 mm |
| Laser Head Weight | 3.2 kg |
| Power Supply Dimensions | 330 × 323 × 463 mm |
| Power Supply Weight | 25 kg |
| Brand | Lighthouse Photonics |
|---|---|
| Origin | USA |
| Model Variants | Sprout-G, Sprout-D, Sprout-H, Sprout-C, Sprout-Solo |
| Wavelength | 532 nm |
| Output Power Range | 3–20 W (model-dependent) |
| Beam Mode | TEM₀₀ |
| M² | 1.0–1.1 |
| Beam Diameter (1/e²) | 2.2–2.3 mm ±10% |
| Beam Divergence | <0.5 mrad |
| Power Stability | <±0.25% RMS (24 h) |
| Intensity Noise | Standard <0.1% RMS (10 Hz–10 MHz), NET Option <0.02% RMS |
| Polarization Ratio | >100:1 (Vertical, Horizontal Optional) |
| Spectral Purity | >99.9% |
| For Sprout-Solo | Linewidth <2 MHz, PZT Tuning Range >8.2 GHz, DC–20 kHz Bandwidth |
| Brand | Lighthouse Photonics |
|---|---|
| Model | Sprout-H |
| Wavelength | 532 nm |
| Output Power Options | 5–20 W (selectable in 1 W increments: 5, 6, 8, 10, 12, 15, 18, 20 W) |
| Beam Mode | TEM₀₀ |
| Beam Quality (M²) | 1.0–1.1 |
| Spectral Purity | >99.9% |
| Polarization Ratio | >100:1 (vertical standard |
| Beam Diameter | 2.3 mm ±10% |
| Beam Divergence | <0.5 mrad |
| Pointing Stability | ≤2 µrad/°C |
| Power Stability | <±0.25% RMS (24 h, closed-loop) |
| Intensity Noise | Standard: <0.1% RMS |
| Low-Noise (NET) Version | <0.02% RMS |
| Cooling | Integrated TEC-based chiller in power supply unit |
| Control Interfaces | USB, RS-232, Ethernet |
| Pump Source Lifetime | >50,000 h |
| Enclosure | Hermetically sealed laser head with Seal™ and Lock™ technologies |
| Cable | Detachable 3 m flexible control cable |
| Compliance | Designed for ISO 13847-compliant optical alignment environments |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | BCS196 |
| Temperature Range | –196 °C to +125 °C |
| Temperature Stability & Accuracy | ±0.01 °C |
| Optical Aperture Diameter | 1.3 mm |
| Sample X–Y Travel | 16 mm |
| Active Sample Area | 22 mm |
| Quenching Rate | Up to 5000 °C/min |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Window Thickness | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.7 mm |
| Dimensions | 135 × 92 × 22.1 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CAP500 |
| Temperature Range | −180 °C to +500 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | <0.1 °C |
| Heating/Cooling Rate | 1–50 °C/min |
| Sample X-Axis Translation | 20 mm |
| Quartz Window Aperture | 22 mm long × 1.6 mm diameter groove for capillary insertion |
| Minimum Working Distance | Objective 4.5 mm / Condenser 12.5 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CCR1000 |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | 1–130 °C/min |
| Temperature Stability | ±1 °C |
| Maximum Pressure | 5 bar (with quartz window) |
| Sample Diameter | 7 mm |
| Sample Mass | 70–100 mg |
| Gas Inlet | 1/16″ stainless steel high-pressure tubing |
| Working Distance for Objective Lens | 6 mm |
| Window Compatibility | Reflectance microscopy, Raman spectroscopy, FTIR |
| Cooling | Integrated water-cooled jacket |
| Construction Materials | Non-reactive ceramics, inert ceramic fiber filter, quartz or sapphire optical windows |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CMS196 |
| Temperature Range | Ambient to –196 °C |
| EM Grid Compatibility | Standard TEM grids, Bessy, Planchette, FEI, Polara formats |
| Motorized XY Stage Resolution | 1 µm |
| Liquid Nitrogen Hold Time | 30 min (standard Dewar) / 6 h (optional 3 L Dewar) |
| Integrated Condenser | For transmitted light and phase contrast |
| Sample Capacity | Up to 3 magnetic sample carriers |
| Startup Time | ≤10 min |
| Drift Performance | <1 nm/min (under stable conditions) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CMS196 |
| Temperature Range | Ambient to −196 °C |
| EM Grid Compatibility | Standard TEM grids, Bessy, Planchette, FEI, Polara formats |
| Motorized XY Stage Resolution | 1 µm |
| Integrated Condenser | For transmitted light and phase contrast |
| LN₂ Hold Time | 30 min (standard Dewar) / 6 h (optional 3 L Dewar) |
| Startup Time | ≤10 min |
| Sample Drift | <1 nm over 10 min |
| Stage Architecture | Decoupled sample holder–Dewar mechanical interface |
| Automation | Magnetic sample cartridge auto-alignment system (up to 3 samples) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CSS450 |
| Temperature Range | −50 °C to 450 °C |
| Temperature Accuracy & Stability | ±0.1 °C |
| Optical Aperture Diameter | 2.5 mm |
| Sample Heating Area | 30 mm |
| Max. Heating/Cooling Rate | 30 °C/min |
| Minimum Objective/Condenser Working Distance | 7.4 mm / 11.5 mm |
| Shear Modes | Oscillatory, Steady, Step |
| Shear Rate Range | 0.003–7500 s⁻¹ |
| Gap Control Range | 5–2500 µm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FTIR600 |
| Temperature Range | −196 °C to 600 °C |
| Temperature Stability | < 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Optical Aperture Diameter | 2.4 mm |
| Sample X–Y Translation Range | 16 mm |
| Heating Area | 22 mm² |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Window Thickness (CaF₂) | 0.17 mm |
| Condenser Angle | 85° |
| Objective Angle | 116° |
| Minimum Working Distance (Objective/Condenser) | 4.5 mm / 12.5 mm |
| Chamber | Sealed, Gas-Purged Compatible |
| Dimensions (L×W×H) | 137 × 92 × 22 mm |