Optical Instruments
Filter
Showing 1621–1650 of 7820 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Quantax XFlash Series |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1,500 kcps |
| Elemental Detection Range | Be to Cf |
| Detector Active Area | 10–300 mm² |
| Window Options | Ultrathin Polymer Window or Windowless Configuration |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUANTAX xsense |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUANTAX XTrace |
| Pricing | Available Upon Request |
| Brand | Bunkoukeiki |
|---|---|
| Origin | Japan |
| Model | WAD |
| Light Source | 150 W Xenon Lamp |
| Spectral Range | 300–1150 nm |
| Bandwidth Options | 5 / 10 / 20 nm (FWHM) |
| Irradiance | ≥1 mW/cm² (≥40 μmol/m²/s) |
| Illumination Area | Ø ≥3 mm |
| Fiber Optic Coupling | Ø3 mm, 1 m length |
| Shutter | Manual |
| Calibration Sensor | Silicon Photodiode |
| Dimensions (W×D×H) | 230 × 295 × 414 mm (excluding protrusions: 242.5 × 350.4 × 441.2 mm) |
| Compliance | CE-marked optical test equipment for laboratory use |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SM25 |
| Pricing | Upon Request |
| Brand | Bunkoukeiki |
|---|---|
| Origin | Japan |
| Model | VC Series-1 |
| Wavelength Range | 300–1300 nm |
| Light Source | Xenon & Halogen Lamps |
| Effective Illumination Area | 10×10 mm (optional 40×40 mm) |
| Irradiance Stability | ±0.5% over 60 min |
| Irradiance Level | 10–50 µW/cm² (energy-stabilized, monochromatic) |
| Target Samples | CMOS image sensor modules, bare sensor dies, digital camera bodies |
| Compliance | ISO/IEC 17025-aligned calibration traceability (NMI-Japan referenced) |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | BXC |
| Pricing | Available Upon Request |
| Brand | BJBY (Beijing Baoyun) |
|---|---|
| Origin | Beijing, China |
| Model | BY-TC1100 |
| Type | Portable Turbidimeter |
| Measurement Principle | 90° Nephelometric Scattering |
| Range Options | 0–20 NTU / 0–200 NTU |
| Minimum Detectable Value | 0.01 NTU (0–20 range) / 0.1 NTU (0–200 range) |
| Accuracy | ±8% of reading (±2.5% F.S.) |
| Repeatability | ≤1% |
| Zero Drift | ±1% F.S. |
| Light Source | Long-life LED (90° scattering geometry) |
| Warm-up Time | ≤30 s |
| Power Supply | 9 V alkaline battery or AC/DC adapter (220 V AC / 50 Hz input |
| Dimensions | 235 × 75 × 65 mm |
| Display | Backlit LCD with microprocessor control |
| Auto Functions | Auto-zero, auto-calibration, auto-shutdown after 10 min inactivity |
| Data Interface | Analog/digital output port (RS-232 or TTL-level, configurable) |
| Compliance | ISO 7027:2016 (Nephelometric method for turbidity measurement) |
| Key | Brand: Benyuan Nanotechnology |
|---|---|
| Model | BY2000 |
| Origin | Beijing, China |
| Instrument Type | Atomic Force Microscope (AFM) / Scanning Tunneling Microscope (STM) / Lateral Force Microscope (LFM) |
| Vertical Position Detection Noise | 0.1 nm |
| Maximum Sample Diameter | 45 mm |
| Maximum Sample Thickness | 15 mm |
| XY Sample Stage Travel Range | 100 mm × 100 mm |
| XY Scan Range | ~10 μm |
| Z Scan Range | ~2 μm |
| Image Resolution Options | 128×128, 256×256, 512×512, 1024×1024 pixels |
| Scan Angle | 0–360° |
| Scan Frequency | 0.1–100 Hz |
| Controller | TI 32-bit DSP with Real-Time OS |
| DAC/ADC | 16-bit high-speed |
| High-Voltage Driver | 5-channel APEX integrated HV op-amps |
| Interface | 10/100 Mbps Fast Ethernet |
| Brand | BYK |
|---|---|
| Origin | Germany |
| Model | A-4430 |
| Measurement Angles | 20° / 60° / 85° |
| Geometry | Single-beam, fixed-angle reflectance |
| Measurement Area | 9 mm × 18 mm (60°), 9 mm × 9 mm (20°), 7 mm × 72 mm (85°) |
| Gloss Unit (GU) Range | 20°: 0–2000 GU |
| 60° | 0–1000 GU |
| 85° | 0–160 GU |
| Repeatability | ±0.5 GU (0–99.9 GU), ±0.2% (100–2000 GU) |
| Reproducibility | ±1 GU (0–99.9 GU), ±0.5% (100–2000 GU) |
| Light Source | Tungsten filament lamp (2.5 V / 60 mA) |
| Detector | Silicon photodiode |
| Data Storage | 999 readings across 50 user-defined groups |
| Interface | RS232 |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z 8741, BS 3900-D5 |
| Traceability | Calibrated against BAM (Bundesanstalt für Materialforschung und -prüfung) and NRC (National Research Council Canada) reference standards |
| Power | One AA alkaline battery (up to 10,000 measurements) |
| Dimensions | 55 × 148 × 72 mm |
| Weight | 500 g |
| Enclosure | Impact-resistant polymer housing with integrated calibration base |
| Brand | BYK-GARDNER |
|---|---|
| Origin | Germany |
| Model | BYK-4561 |
| Measurement Angle | 60° |
| Application | Medium-Gloss Surfaces (Paints & Plastics) |
| Measuring Area | 9 × 15 mm |
| Display | Full-color TFT LCD |
| Data Storage | Onboard memory for >1,000 readings |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Software Included | smart-process Gloss (2-user license) |
| Power | Rechargeable Li-ion battery (≥10,000 measurements per charge) |
| Interface | USB-C |
| Brand | BYK-GARDNER |
|---|---|
| Origin | Germany |
| Model | BYK-4563 |
| Measurement Angles | 20°, 60°, 85° |
| Display | Full-color TFT LCD |
| Data Storage | Internal memory for up to 10,000 readings |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Power Supply | Rechargeable Li-ion battery (up to 10,000 measurements per charge) |
| Interface | USB 2.0 |
| Software Included | smart-chart QC software with trend analysis and pass/fail reporting |
| Measurement Area | 20°: Ø 4 mm |
| 60° | Ø 6 mm |
| 85° | Ø 8 mm |
| Repeatability | < 0.2 GU (per angle, on certified gloss standard) |
| Inter-instrument Agreement | < 0.5 GU (across calibrated units, per ISO 2813) |
| Brand | BYK-GARDNER |
|---|---|
| Origin | Germany |
| Model | BYK4561 |
| Type | Automatic |
| Gloss Measurement Angle | 60° |
| Gloss Range | 0–2000 GU |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–20 GU), ±0.5 GU (20–100 GU), ±0.5% (100–2000 GU) |
| Measurement Area | 9 × 15 mm |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Brand | BYK-GARDNER |
|---|---|
| Origin | Germany |
| Model | BYK4564 |
| Type | Automatic Tri-Angle Gloss Meter |
| Gloss Angles | 20°, 60°, 85° |
| Measurement Area (per angle) | 10×10 mm (20°), 9×15 mm (60°), 5×38 mm (85°) |
| Gloss Range | 0–2000 GU |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–20 GU), ±0.5 GU (20–100 GU), ±0.5% (100–2000 GU) |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741, BS 3900-E7 |
| Software Compatibility | smart-lab Gloss, smart-process Gloss |
| Data Interface | USB |
| Power | Rechargeable Li-ion battery |
| Operating Temperature | 10–40 °C |
| Storage Temperature | –10–50 °C |
| Brand | BYK-GARDNER |
|---|---|
| Origin | Germany |
| Model | BYK 4563 |
| Measurement Angles | 20°, 60°, 85° |
| Optical Aperture | 9×15 mm (60°), 10×10 mm (20°), 5×38 mm (85°) |
| Gloss Range | 0–2000 GU |
| Repeatability | ±0.2 GU (0–100 GU), ±0.2% (100–2000 GU) |
| Transmittance Range | 0–100% |
| Transmittance Repeatability | ±0.2% |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741, TAPPI T 480, BS 3900-E7 |
| Software Interface | smart-chart™ and smart-lab™ |
| Probe Type | Dual-mode (magnetic/non-magnetic) for coating thickness + gloss on metal substrates |
| Operating Temperature | 10–40 °C |
| Storage Temperature | –20–60 °C |
| Battery Life | >10,000 measurements per charge |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK 4563 |
| Measurement Angles | 20°, 60°, 85° |
| Compliant Standards | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Display | Full-color TFT screen with intuitive navigation |
| Calibration | Integrated auto-diagnostic system with certified reference standard stored in protective calibration base |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–20 GU), ±0.5 GU (20–100 GU), ±0.5% (100–2000 GU) |
| Measurement Area | 20°: 10×10 mm, 60°: 9×15 mm, 85°: 5×38 mm |
| Data Interface | USB |
| Software Compatibility | smart-lab Gloss & smart-process Gloss (30-day free trial per package) |
| Brand | BYK-GARDNER |
|---|---|
| Country of Origin | Germany |
| Model | BYK 4565 |
| Type | Automatic Tri-angle Gloss Meter |
| Measurement Angles | 20°, 60°, 85° |
| Gloss Range | 0–2000 GU |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741, GB/T 9754 |
| Display | Full-color TFT touchscreen |
| Interface | Bluetooth 5.0, USB-C |
| Data Storage | Internal memory (≥10,000 readings), SD card slot |
| Software Compatibility | smart-chart™ v5.x, smart-lab™ Gloss |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK-Micro-TRI-Gloss 4567 |
| Type | Automatic |
| Transmission Range | 0–100% |
| Transmission Repeatability | ±0.2% |
| Measurement Angle | 45° |
| Measuring Spot Size | 9 × 13 mm |
| Compliant Standards | ASTM D2457, ISO 2813, JIS Z8741, TAPPI T 480, DIN 67530 |
| Brand | BYK-Gardner |
|---|---|
| Country of Origin | Germany |
| Model | BYK 4568 |
| Type | Automatic |
| Transmission Range | 0–100% |
| Transmission Repeatability | ±0.2% |
| Measurement Angle | 75° |
| Application Focus | Paper, Paperboard, Coated & Uncoated Substrates, PVC Vinyl Wall Panels |
| Compliant Standards | ASTM D2457, ASTM D3679, TAPPI T 480, JIS Z 8741 |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK 4569 |
| Measurement Angles | 60° only |
| Aperture Size | 2 × 4 mm |
| Gloss Range | 0–2000 GU |
| Repeatability | ±0.2 GU (0–100 GU), ±0.2% (100–2000 GU) |
| Reproducibility | ±0.5 GU (0–100 GU), ±0.5% (100–2000 GU) |
| Spectral Response | CIE standard observer (illuminant C) |
| Measurement Time | 0.5 s |
| Substrate Compatibility | Fe (magnetic) and NFe (non-magnetic) |
| Coating Thickness Range | 0–500 µm |
| Thickness Accuracy | ±(1.5 µm + 2% of reading) |
| Memory Capacity | 999 readings with timestamp |
| Interface | USB |
| Power | 1 × AA alkaline battery (≈4,000 measurements) or USB bus power |
| Dimensions | 155 × 73 × 48 mm |
| Weight | 0.4 kg |
| Operating Temperature | 15–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Brand | BYK-GARDNER |
|---|---|
| Origin | Germany |
| Model | BYK4570 |
| Type | Automatic |
| Gloss Range | 0–20 GU (low-gloss mode), 20–100 GU, 100–2000 GU |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Measurement Spot Size | 2 mm × 4 mm |
| Compliant Standards | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK 4566 |
| Measurement Angles | 20°, 60°, 85° |
| Display | Full-color TFT touchscreen |
| Interface | USB |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Measurement Range | 0–2000 GU (angle-dependent) |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–20 GU), ±0.5 GU (20–100 GU), ±0.5% (100–2000 GU) |
| Probe Type | Dual-mode (magnetic/non-magnetic) for coating thickness integration |
| Optional Thickness Measurement | ISO 2360, ISO 2808, ASTM B499, D1400 |
| Calibration | Traceable certified standard tile included |
| Software Compatibility | smart-lab Gloss & smart-process Gloss (30-day trial, dual-license) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | C84-III-B |
| Pricing | Available Upon Request |
| Measurement Range | 0–100 % |
| Resolution | 0.1 % |
| Accuracy | ±1 % |
| Repeatability | ±0.3 % |
| Operating Temperature | 20 °C ± 5 °C |
| Relative Humidity | < 85 % RH |
| Power Supply | 220 V ± 10 %, 50 Hz |
| Compliance | GB/T 13452.3–1992, GB 9270–1988, GB 5211.17–1988, ISO 3906:1980(E) |
| Brand | CactuX |
|---|---|
| Model | SaguaroX Series |
| Type | Motorized Precision Translation Stage |
| Origin | Czech Republic |
| IP Rating | IP20 |
| RF Emission | < 4 mW |
| Power Input | 24 V DC / 2.5 A (5.5 × 2.1 mm barrel connector) |
| Max Input Power | 50 W |
| Battery | Li-ion (14.6 V / 3.4 Ah for S, 14.6 V / 5.54 Ah for M & M Heavy) |
| Operating Time | ~8 h (S), ~16 h (M & M Heavy) |
| Travel Speed | 9 mm/s (S), 10 mm/s (M & M Heavy) |
| Enclosure Protection | IP20 |
| Brand | CactuX |
|---|---|
| Origin | Czech Republic |
| Model | Spirit Resolution |
| Component Type | Optical Calibration Phantom |
| Compliance | ASTM E1695-95 |
| Material | Synthetic Ruby & Carbon |
| Voxel Size Range | < 1 µm to > 10 µm |
| Ball Diameters | 0.5 / 1.0 / 2.5 / 5.0 mm |
| Maximum Feature Widths | 1.0 / 2.0 / 5.0 / 10.0 mm |
| Mounting Post Dimensions | Ø1.5 / Ø1.5 / Ø3.0 / Ø5.0 mm × 50.0 mm (L) each |
| Brand | Caikon |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | CK400CM |
| Power Input | AC 220 V ±10%, 45–60 Hz |
| Heating Supply | DC 24 V / 3 A |
| Max. Power Consumption | 260 W |
| Temperature Range | Ambient to 400 °C (tested at 25 °C ambient, natural convection cooling) |
| Stage Surface Temp. Limit | ≤70 °C at housing (when hot zone = 400 °C) |
| Max. Sample Load | 200 g |
| Heating Zone Diameter | φ41 mm |
| Stage Disc Diameter | φ99 mm × 11 mm thick |
| Optical Aperture | φ3.8 mm |
| Display | Industrial capacitive full-color touchscreen, 800 × 480 resolution |
| Control Core | 32-bit ARM processor with proprietary fuzzy PID adaptive algorithm |
| Heating Element | Ceramic PTC heater with uniform thermal distribution |
| Temp. Accuracy | ≤±0.5% of full scale |
| Temp. Stability (Drift) | ±0.5 °C |
| Response Time (Setpoint Hold) | ≤0.01 s |
| Ramp Rates | 5, 10, 20, 40, or 80 °C/min (user-selectable) |
| Ramp Time | ≤100 s (RT → 100 °C), ≤190 s (RT → 200 °C), ~17 min (RT → 400 °C, dependent on ambient & ramp rate) |
| Dimensions (Control Unit) | 280 × 220 × 150 mm |
| Brand | Caikon Optical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Upright Metallurgical Microscope |
| Equipped with Image Analysis Software | Yes |
| Total Optical Magnification | 50×–500× (up to 2000× with system magnification) |
| Eyepiece | Wide-Field 10× (Φ22 mm) |
| Objective Lenses | PL 5×/0.12, PL 10×/0.25, PL 40×/0.60 (spring-loaded), PL 60×/0.70 (spring-loaded) |
| Focusing Mechanism | Coaxial coarse/fine focus, fine adjustment graduation: 2 µm |
| Illumination | 6 V / 30 W halogen lamp (adjustable brightness, Köhler illumination for both epi- and trans-illumination) |
| Stage | Dual-layer mechanical stage (210 × 140 mm, travel range 75 × 50 mm) |
| Polarization System | Insertable polarizer/analyzer, 360° rotatable analyzer, removable from optical path |
| Camera | CK-500 Color CMOS Camera (2560 × 1920 resolution, 12-bit A/D, USB 2.0 interface, 22 fps at full resolution) |
| Software | Full-featured metallurgical image analysis suite supporting measurement (≥1 µm accuracy), annotation, report generation (PDF/CSV/XLS), GLP-compliant audit trail logging, and ISO 13079-compliant grain size evaluation |
| Brand | Cairn |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Multisplit V2 |
| Pricing | Available Upon Request |
| Brand | Cairn |
|---|---|
| Origin | United Kingdom |
| Model | OptoScan |
| Light Source Type | Xenon Lamp |
| Illumination Mode | Internal Illumination |
| Optical Design | Enhanced Czerny-Turner |
| Grating Options | 1200 lp/mm (UV-Vis), optional 1800/2000 lp/mm holographic gratings |
| Wavelength Range | 300–800 nm |
| Wavelength Accuracy | ±1.5 nm |
| Spectral Resolution | 0.5 nm (FWHM) |
| Bandwidth Range | 0–30 nm |
| Bandwidth Accuracy | ±0.2 nm |
| 200 nm Wavelength Switching Time | <1.5 ms |
| 50 nm Wavelength Switching Time | <1.0 ms |
| Slit-Driven Bandwidth Switching Time | <1.5 ms |
| TTL Digital Shutter Response | <2 ms |
| Dimensions (L×W×H) | 230 × 180 × 180 mm |
| Brand | Cairn |
|---|---|
| Origin | United Kingdom |
| Model | OPTOSPIN 32 |
| Filter Diameter | 32 mm |
| Positions per Wheel | 6 |
| Max Speed | 7500 rpm |
| Step Time (adjacent) | 40 ms |
| Step Time (opposite) | 70 ms |
| Dimensions | 120 × 120 × 35 mm |
| Interface | USB and TTL digital |
| Compatible Filter Sizes | 32 mm (standard), 25 mm (with adapter ring) |
| Mounting | Dual-wheel configuration supported within 35 mm optical path |
| Software Compatibility | NIS-Elements, SlideBook, Micro-Manager, MetaMorph |