| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Origin | Domestic (China) |
| Model | FLQ1004 |
| Light Source Type | Broadband Continuous Arc Lamp (Configurable for Xenon or Mercury Short-Arc Lamps) |
| Illumination Mode | External Illumination (Collimated or Diffuse Beam Delivery) |
| Integrating Sphere Diameter Options | 200 mm, 300 mm, 500 mm (Custom Diameters Available) |
| Control Interface | RS-232 / USB / Ethernet (via Integrated Controller) |
| Attenuation Mechanism | Motorized Iris Aperture + Motorized Neutral Density Filter Wheel + Electronic Shutter |
| Software Control | Windows-Based GUI with Real-Time Intensity Calibration & Log Data Export |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SKP5050 |
| Component Category | Optical Component |
| Spatial Resolution (Scanning Stage) | <317.5 nm |
| Work Function Resolution | <3 meV |
| Sample Size Range | 5–300 mm |
| Brand | Keopsys |
|---|---|
| Origin | France |
| Model | PUFL |
| Wavelength | 355 nm |
| Output Type | Free-space, collimated beam |
| Pulse Energy | up to 1.6 µJ |
| Peak Power | up to 1.6 kW |
| Average Power | up to 80 mW |
| Repetition Rate | 50 kHz |
| Beam Quality (M²) | < 1.3 |
| Power Consumption | Low |
| Package | Compact and rugged |
| Application Fields | Aerosol detection, fluorescence excitation, Raman spectroscopy, biological experimentation, wafer inspection |
| Brand | CHEMn (Distributor) |
|---|---|
| Origin | USA |
| Model | PR160 |
| Light Source Type | High-Precision Tunable LED Array |
| Illumination Mode | External Irradiation |
| Max Power | 40 W |
| Input Voltage | 100–240 V AC |
| Operating Temperature | 0–40 °C |
| Beam Angle | 56° |
| Peak Wavelength Options | 370 nm, 390 nm, 427 nm, 440 nm, 456 nm, 467 nm, 525 nm, 640 nm, 740 nm |
| Irradiance | 2.3 mW/mm² (measured at 1 cm distance) |
| Dimensions (H × D) | 114 mm × 63 mm |
| Spectral Accuracy | ±1 nm |
| Output Stability | ±3% over rated operating conditions |
| Brightness Control | 4-step discrete intensity adjustment |
| Mounting Compatibility | Universal lab clamp, dedicated PR160 adjustable stand |
| Origin | UK |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KP020 |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | KSMG Series |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer | ZOLIX (OEM/ODM Capable) |
| Model | KSMR5A-100 / KSMR5A-120 |
| Construction Material | Aerospace-Grade Aluminum Alloy |
| Top Plate Diameter | 100 mm / 120 mm |
| Coarse Rotation Range | ±360° |
| Fine Adjustment Range | ±5° |
| Angular Sensitivity | 4 arcseconds |
| Minimum Graduation | 5 arcminutes |
| Drive Mechanism | Precision Micrometer Head (Calibrated Vernier Scale) |
| Axial Runout (TIR) | <30 µm |
| Horizontal Center Load Capacity | ≤10 kg |
| Optical Aperture Option | Available with or without Central Through-Hole |
| Compliance | Designed to meet ISO 9283 (Robotic Manipulator Performance Criteria) and ASTM E2920 (Standard Practice for Calibration of Angular Positioning Devices) guidelines for manual optical positioning systems |
| Mounting Interface | Standard M6 threaded holes on base and top plate per ANSI/B46.1 surface finish spec |
| Brand | Labsphere |
|---|---|
| Model | ACR |
| Origin | Shanghai, China |
| Light Source Type | Tunable Integrating Sphere Source (Xenon/Mercury-Hybrid Capable) |
| Illumination Geometry | Internal Illumination |
| Color Temperature Range | 2000 K – 10000 K (CCT-adjustable) |
| Spectral Output | Programmable to CIE Standard Illuminants (A, D50, D65, D75, etc.) |
| Luminance Range | 0.01 – 100,000 cd/m² (adjustable) |
| Viewing Angles | 0°, 15°, 30°, 45° (symmetrical left/right ports |
| Detector Platform | Motorized Linear Rail with Sub-millimeter Positioning Accuracy |
| Compliance Standards | ICDM, VESA DisplayHDR™, NIST IR 6738, ISO 9241-307, CIE S 023/E:2022 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | AUX |
| Component Category | Light Source |
| Compatible Power Supply | Adjustable Labsphere Power Supply |
| Software Compatibility | LightMtrx® |
| Nominal Current Ratings | AUX-35 (3.07 A), AUX-50 (4.17 A), AUX-100 (8.33 A) |
| Mounting | 1-inch flange interface |
| Replacement Lamps | OC-03150-000 (AUX-35), OC-03161-000 (AUX-100) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Blue Sun |
| Light Source Type | Xenon-based broadband solar simulator |
| Illumination Mode | External illumination |
| Spectral Range | 400–2500 nm |
| Output Stability | <0.5% RMS over 8 hours |
| Spectral Smoothness | <1.5% spectral gradient in visible range |
| Calibration Interval | ≥12 months (under recommended operating conditions) |
| Lifetime | ≥2000 hours (xenon arc lamp, typical) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Helios-D Series |
| Light Source Type | Tungsten-Halogen |
| CCT | 3000K ± 50K |
| Exit Port Diameter | 2", 4", or 8" |
| Max Luminance | Up to 80,000 cd/m² |
| Exit Port Illuminance | Up to 251,200 lux |
| Angular Uniformity (FOV) | ±2.0% within ±35° |
| Internal Coating | Spectraflect or Spectralon |
| Variable Attenuator Options | Advanced VAA-220A (2.00E+06 steps), Dynamic VAD-012/VAD-021 (2.40E+04–4.80E+04 steps), Manual VA-MM (2.00E+04–4.00E+04 steps) |
| Dynamic Range | Up to 160 dB (26-bit equivalent) |
| Software Interface | HELIOSense GUI with LSAPI support |
| Compliance | Designed for ASTM E308, ISO/CIE colorimetry standards, and GLP/GMP-aligned calibration traceability |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Helios-LL Series |
| Light Source Type | Tungsten-Halogen |
| CCT | 2856 K ±50 K |
| Spectral Distribution | Blackbody-like |
| Integrating Sphere Coating | Spectraflect or Spectralon |
| Output Port Diameter | 2–8 in (0.05–0.2 m) |
| Sphere Diameter | 7.5–20 in (0.19–0.5 m) |
| Max Luminance | 1,600–9,500 cd/m² |
| Illuminance at Port | 5,000–30,000 lux |
| Dynamic Range | 4.00E+09 to 1.00E+10 (31–32 bits, 196–199 dB) |
| Angular Uniformity (FOV ±35°) | ±2.0% |
| Attenuation System | Advanced Variable Attenuator (VAA), 6.00E+06 to 8.80E+06 steps |
| Detector Configuration | Dual Silicon Detectors (SD-S1 & SD-L1) |
| Software Interface | HELIOSense GUI with LSAPI support |
| Compliance | MIL-STD-810G, ISO/IEC 17025 traceable calibration options available |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Helios-Plus AMA |
| Light Source Type | Xenon Arc Lamp |
| Illumination Mode | Internal Illumination |
| CCT Range | 3000 K to 6000 K |
| Spectral Range (Standard) | 350–1000 nm |
| Spectral Range (UV-Optimized) | 200–850 nm |
| Opening Diameter | 4 in or 8 in |
| Max Luminance | Up to 47,300 cd/m² |
| Opening Illuminance | Up to 182,000 lux |
| Field of View Uniformity | ±2.0% over 35° |
| Attenuation Options | Advanced Variable Attenuator (VAA), Dynamic Variable Attenuator (VAD), Manual Micrometer Attenuator (VA-MM) |
| Attenuator Resolution | Up to 2.00E+06 steps |
| Dynamic Range | Up to 152 dB |
| Integrated Spectroradiometer | Yes |
| Calibration Traceability | NIST-traceable |
| Compliance | ASTM E927, ISO 9050, MIL-STD-810G (optical testing), USP <1059>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | Labsphere |
|---|---|
| Model | Helios-V Series |
| Origin | USA |
| Light Source Type | Tungsten-Halogen (3000K Blackbody Simulated) |
| Integrating Sphere Diameter | 12 in |
| Output Port Diameter | 4 in (0.1 m) |
| Luminance Range | 0.001–11,500 cd/m² |
| Illuminance at Port | Up to 36,000 lux |
| CCT | 3000K ±50K |
| Spectral Range | 300–2400 nm |
| Uniformity (FOV 35°) | ±2.0% |
| Attenuation Method | Manual VA-MM or Dynamic VAD |
| Attenuator Steps | 1.00E+04 (NMNN) / 1.20E+04 (NDNN) |
| Dynamic Range | 5.00E+04 (93 dB, 16-bit) / 1.20E+04 (81 dB, 14-bit) |
| Internal Coating | Spectraflect® |
| Compliance | ASTM E308, ISO/CIE 11664, NIST-traceable calibration options available |
| Software Interface | HELIOSense™ via Labsphere LSAPI |
| Brand | Labsphere |
|---|---|
| Model | LFFP-200-N |
| Origin | USA |
| Light Source Type | Tunable White LED Array |
| Color Temperature Range | 3000 K – 6000 K (continuously adjustable) |
| Luminance Range | 100 – 15,000 cd/m² (nit) |
| Active Emitting Area | 200 mm × 200 mm |
| Spatial Uniformity | ≥95% across active area |
| Control Interface | SDK available for C/C++, Python, LabVIEW, and .NET (English, Chinese, Japanese localizations supported) |
| Compliance | CE, RoHS, FCC Class A |
| Brand | LabSphere |
|---|---|
| Model | LFUSS |
| Coating | Spectraflect® or Spectralon® |
| Internal Diameter Options | 15 cm – 200 cm |
| Spectral Range | 350–2500 nm |
| Calibrated Radiance Range | 0–40,000 nit |
| Uniformity | ≥98% |
| Stability | ±0.1% |
| Light Source Type | Tungsten-halogen (150 W external + multiple internal options: 35/75/100/150 W) |
| Illumination Method | Internal illumination |
| Motorized Attenuator | ≥35,000 steps |
| Calibration Traceability | NIST and NIM (China National Institute of Metrology) |
| Operating Temperature | 20–40 °C |
| Detector Type | Silicon photodiode |
| Validated Spectral Calibration Range | 360–1100 nm |
| Color Temperature | 2856 ± 50 K |
| Aperture Configurations | Dual detector ports + variable source access ports |
| Software Compatibility | LabSphere Uniform Source Measurement Software (customizable) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPM |
| Coating | Infragold (700 nm – 20 µm) |
| Max Incident Power Density | 2 kW/cm² @ 10.6 µm (CW) |
| Cooling | Water-cooled (NPT 0.25", max 15 psi operating, 35 psi safety relief) |
| Detector Ports | Two standard SMA or flanged ports |
| Spectral Range | UV–Vis–NIR–MIR (compatible with Labsphere calibrated detectors) |
| Target Plate | Integrated energy-diffusing plate |
| Compliance | ASTM E275, ISO/IEC 17025-aligned calibration traceability, GLP-ready documentation support |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LS-LED-Production |
| Uniformity (Exit Port) | ≥98% |
| Exit Port Diameter | 45 mm |
| CCT Tuning Range | Adjustable Continuous from Warm to Cool White (Typ. 2700 K – 6500 K) |
| Illuminance Tuning Range | Continuously Adjustable (0–10,000 lx typical at port) |
| Control Resolution | Millisecond-level Setpoint Response |
| Power Supply | Integrated Multi-channel Constant-Current LED Drivers |
| Monitoring | Real-time Photometric Feedback (Illuminance, LED Forward Voltage/Current Decay) |
| Compliance | Designed for ISO/IEC 17025-compliant calibration workflows |
| Optional Add-on | Spectral Monitoring Module (VIS, 380–780 nm) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | PT-038-PLS |
| Light Source Type | Tungsten-Halogen (Standard Configuration) |
| Spectral Range | 380–1000 nm (Typical) |
| Luminance Range | 0.1–10,000 cd/m² (Adjustable via Precision Attenuation) |
| Uniformity | ≤ ±0.5% over Central 80% Area |
| Stability | ≤ ±0.2% over 30 min (Thermally Stabilized) |
| Portability | Integrated Battery Option (Optional), < 8 kg |
| Compliance | NIST-Traceable Calibration Certificate Included |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPECTRA-CT |
| Light Source Type | Tunable Broadband LED-Based Integrating Sphere Source |
| Illumination Method | Internal Illumination |
| Key Dimensions (CT-1000-S / M / L) | 20/30/50 cm sphere diameter |
| Output Aperture | 5/10/20 cm |
| Spectral Range | UV-Vis-NIR (250–1700 nm) |
| Luminance Range | 0.1–500,000 cd/m² (model-dependent) |
| Uniformity | >99% (per EMVA 1288 Annex A) |
| Color Temperature Range | 2800–7500 K |
| CCT Uniformity | ±15 K |
| Short-Term Stability | ±0.1% over 10 min |
| Warm-up Time | ≤30 s |
| Monitoring Sensor | Integrated Silicon Photodiode |
| Control Interface | USB + Ethernet |
| Software SDK | Yes (C/C++, Python, LabVIEW compatible) |
| Compliance | Fully supports EMVA 1288:2016 for camera characterization |
| Brand | Labsphere |
|---|---|
| Model | Spectra-FT |
| Origin | USA |
| Light Source Type | Tungsten-Halogen & LED Hybrid Spectral Engine |
| Spectral Range | 390–1000 nm |
| Luminance Range | 10–25,000 cd/m² |
| Field Uniformity | >98% over 360° × 200° FOV |
| Calibration Traceability | NIST-traceable spectral radiance |
| Feedback System | Integrated spectroradiometric real-time feedback loop |
| Re-calibration | User-executable via SpectraSoft™ v4.2 |
| Compliance | ASTM E308, ISO/CIE 11664, USP <1033>, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectra-FT VIS-NIR |
| Output Aperture | 75 mm (Ø) |
| Spectral Range | 380–1050 nm |
| Max Luminance | 25,000 cd/m² |
| LED Channels | 32 |
| Uniformity | >98% over 360° × 200° FOV |
| Integrated Spectrometer | Yes |
| Compliance | ISO/IEC 17025 traceable calibration support, NIST-traceable spectral radiance characterization available |
| Software Control | USB/Ethernet, Labsphere SpectraSuite™ v5.0+ with real-time feedback loop |
| Operating Temperature Stability | ±0.1°C active thermal regulation |
| Radiometric Accuracy | ±2.5% (k=2, 380–950 nm, relative to NIST SRM) |
| Brand | Labsphere |
|---|---|
| Model | Spectra-PT |
| Origin | USA |
| Light Source Type | Integrating Sphere-Based Uniform Radiance/Luminance Source |
| Sphere Diameter | 13.5 cm |
| Output Port Diameter | 5 cm |
| Variable Aperture | Motorized, Precision Automatic (VA) |
| Built-in Reference Photodetector | Yes |
| Luminance Range | 0.01–50,000 cd/m² (continuous, programmable) |
| Spectral Output | Broadband (Xenon or Mercury-based, configurable) |
| Calibration | NIST-traceable spectral radiance and luminance |
| Compliance | ISO/IEC 17025-accredited calibration certificate included |
| Software Interface | LabVIEW-compatible, USB/Ethernet control, GUI for preset definition and real-time monitoring |
| Form Factor | Integrated benchtop enclosure with mobility handles |
| Optional Configuration | Wide-Angle Field-of-View (WAF) version available for >180° FOV imaging systems |
| Brand | Labsphere |
|---|---|
| Model | Spectra-UT |
| Origin | USA |
| Light Source Type | Tunable Hyperspectral Source with Integrated Tungsten-Halogen (QTH) Reference Lamp and Onboard Spectrometer |
| Spectral Range | 380–780 nm (Visible) |
| Spectral Resolution | Adjustable down to ~10 nm FWHM |
| Output Uniformity | >98% over 50 mm Ø field (flat-field compliant) |
| Control Interface | USB 2.0 + Ethernet |
| Software | SpectraSoft v4.x (Windows-based, supports scripting via Python API) |
| Calibration Traceability | NIST-traceable via integrated QTH lamp and factory-characterized spectrometer |
| Compliance | ISO/IEC 17025–accredited calibration documentation available |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Cooling | Forced-air thermal management system |
| Dimensions | 320 × 240 × 180 mm (W × D × H) |
| Weight | 8.2 kg |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectra-UT |
| Light Source Type | Tunable Solid-State Spectral Source |
| Illumination Mode | External Illumination |
| Spectral Range | 390–780 nm |
| FWHM | 12 nm ± 2 nm |
| Peak Wavelength Spacing | 0.4 nm |
| Spectral Accuracy | < 0.5 nm |
| Max Luminance | 1000 cd/m² |
| Luminance Adjustment Range | 25–1000 cd/m² |
| Luminance Uniformity | ≥99% |
| Max Spectral Scan Rate | < 1.0 spectrum/sec |
| Brand | Labsphere |
|---|---|
| Model | SPECTRAFLECT |
| Origin | USA |
| Base Material | Barium Sulfate (BaSO₄) with Proprietary Binder System |
| Spectral Range | 300–2400 nm |
| Average Diffuse Reflectance (400–700 nm) | 96–98% |
| Lambertian Character | >99.5% (cosine angular response) |
| Thermal Stability | Up to 100 °C |
| Laser Damage Threshold | 1.7 J/cm² (at 1064 nm, 10 ns pulse) |
| Application Method | Air-spray or HVLP spray |
| Substrate Compatibility | Aluminum, stainless steel, anodized metals, ceramics, and machined polymers |
| Compliance | RoHS-compliant, non-toxic, solvent-based formulation (proprietary low-VOC carrier) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectralon |
| Reflectance | >99% (400–1500 nm), >95% (250–2500 nm) |
| Lambertian Character | Excellent |
| Chemical Stability | Inert |
| Thermal Stability | High |
| UV Resistance | Certified for Space-Grade Exposure |
| Compliance | NASA/JPL, GSFC, TRW, CSEM Qualified |
| Form Factor | Custom-Machinable Solid PTFE-Based Material |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectralon® |
| Material | PTFE-based sintered polymer |
| Spectral Range | 250–2500 nm |
| Reflectance Options | 2%, 5%, 10%, 20%, 25%, 40%, 50%, 60%, 75%, 80%, 99% |
| Spectral Flatness | ±1% (400–1500 nm), ±4% (250–2500 nm) |
| Lambertian Character | >99.9% |
| Calibration Traceability | NIST-traceable |
| Physical Form | Circular disk (1.25″ or 2.00″ diameter) |
| Packaging | Polyoxymethylene (POM) protective case with lid |
| Compliance | ASTM E259, ISO 13468-2, USP <857> |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | WS-1 |
| Component Type | Optical Reference Standard |
| Spectral Range | 250–2000 nm |
| Diffuse Reflectance | >98% (400–1500 nm), >95% (250–2000 nm) |
| Substrate Material | PTFE (Polytetrafluoroethylene) |
| Housing | Anodized Aluminum |
| Diameter (with housing) | 38 mm |
| Thickness | 10 mm |
| Weight | 30 g |
| Compliance | NIST-traceable calibration available (optional) |
| Brand | Labthink |
|---|---|
| Model | SPS-80T |
| Light Sources | CIE Standard Illuminant D65 (6500 K, Ra > 90) and Illuminant A (2900 K, Ra = 100) |
| Viewing Area | 1050 mm × 700 mm |
| Cabinet Dimensions | 1050 mm (L) × 800 mm (W) × 2100 mm (H) |
| Net Weight | 40 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Illumination Method | External Projection |
| Compliance | CIE No. 51, ISO 3664:2009, CY/T 3–1991, ASTM D1729, DIN 6173-2 |