Optical Laboratory Equipment
Filter
Showing 841–870 of 1781 results
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | LAS X ID Modules |
| Price Range | USD 14,000 – 28,000 (based on configuration and licensing) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LAS X ID Modules |
| Price Range | USD 13,500 – 27,000 |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | LED1, LED3, LED5, LED8 |
| Light Source Type | Solid-State LED |
| Illumination Mode | Epi-illumination (External) |
| Wavelength Range (LED1) | 380–650 nm (White + 4 Discrete Channels) |
| Compatibility | Leica DM2500, DM4 B Microscopes |
| Control Interface | Analog Knob + TTL Trigger |
| LED Pod Support | Yes |
| Regulatory Compliance | CE, RoHS, IEC 61000-6-3 |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Leica LMD Software |
| Price Range | USD 13,500 – 27,000 (FOB Europe) |
| Regulatory Compliance | CE-marked, ISO 13485-aligned design controls, compatible with FDA 21 CFR Part 11–enabled audit trail configurations (when deployed with validated IT infrastructure) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Leica MAP |
| Price Range | USD 13,500 – 27,000 |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | OHX |
| Component Type | Surgical Microscope Integration Module |
| Display Resolution | 1920 × 1080 (Full HD) |
| Contrast Ratio | 500:1 |
| Light Source | LED backlight |
| Display Technology | LCD |
| Viewing Options | Monocular (left/right), Binocular (dual-eye), Overlay or Non-overlay Mode |
| Control Interface | Integrated microscope handle button, Wireless footswitch, Optional control panel |
| IGS Compatibility | Native integration with major neurosurgical navigation platforms (e.g., BrainLab, Stryker, Medtronic StealthStation) |
| Fluorescence Support | FL800 fluorescence mode synchronization |
| Recording Capability | Full HD video capture with metadata tagging (magnification, working distance, illumination ratio, acquisition timestamp) |
| Mounting | Integrated within Leica M530 surgical microscope main body |
| Regulatory Status | CE-marked as Class IIa medical device |
| Compliance | EN ISO 13485, IEC 60601-1, FDA 510(k) cleared (K220227), supports 21 CFR Part 11 audit trail when paired with Leica LAS X NAV software |
| Brand | Leica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PL APO Apochromatic Objective |
| Component Type | Optical Element |
| Field Flatness | Up to 25 mm |
| Chromatic Correction | Red, Green, and Blue wavelengths (3-color) |
| Axial Chromatic Aberration | ≤ 1.0× objective depth of field |
| Transmission Range | ≥85% from 470–1200 nm (IR-APO variant) |
| NA Range | Up to 1.4–1.6 (model-dependent) |
| Application Scope | Visible & near-IR imaging, multiphoton microscopy, CARS, confocal, live-cell water immersion, UV-stable confocal (CS2 series) |
| Brand | Leica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Semi-Apochromat Objective |
| Component Type | Optical Element |
| Field Flatness | Up to 25 mm |
| Chromatic Correction | Red, Green, and Blue wavelengths (3-band) |
| Axial Focus Deviation | ≤ 2.5× objective depth of field |
| Designation | PL FLUOTAR (PL-FL) |
| Application Domain | High-fidelity visible-spectrum microscopy, fluorescence imaging, live-cell observation |
| Correction Features | Adjustable correction collar (CORR) for coverslip thickness, immersion medium, and thermal drift compensation |
| Optical Material | High-transmission specialty glass |
| Compliance Context | Designed for use in ISO/IEC 17025-accredited labs |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Leica Rotatable Beamsplitter |
| Component Category | Optical Beam Steering Assembly |
| Compatibility | Leica M620, M820, M525 F20, M525 F40 Surgical Microscopes |
| Intended Use | Dual-observer surgical visualization and rapid optical path switching |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TL3000 Ergo and TL5000 Ergo |
| Numerical Aperture (NA) | 0.73 (TL3000 Ergo), 0.9 (TL5000 Ergo) |
| Illumination | High-stability white LED |
| Contrast Modes | Brightfield, Rottermann Contrast, Unilateral or Bilateral Darkfield |
| Field Diameter | 65 mm |
| Cooling | Passive (max. +6°C above ambient) |
| Software Integration | Fully encoded |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Water Immersion Micro |
| Component Type | Water Immersion Objective Auxiliary System |
| Compliance | Designed for ISO 10993-compliant biological imaging workflows |
| Integration | Fully compatible with Leica DMi8 and THUNDER imaging platforms |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | BCS196 |
| Temperature Range | –196 °C to +125 °C |
| Temperature Stability & Accuracy | ±0.01 °C |
| Optical Aperture Diameter | 1.3 mm |
| Sample X–Y Travel | 16 mm |
| Active Sample Area | 22 mm |
| Quenching Rate | Up to 5000 °C/min |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Window Thickness | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.7 mm |
| Dimensions | 135 × 92 × 22.1 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CAP500 |
| Temperature Range | −180 °C to +500 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | <0.1 °C |
| Heating/Cooling Rate | 1–50 °C/min |
| Sample X-Axis Translation | 20 mm |
| Quartz Window Aperture | 22 mm long × 1.6 mm diameter groove for capillary insertion |
| Minimum Working Distance | Objective 4.5 mm / Condenser 12.5 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CCR1000 |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | 1–130 °C/min |
| Temperature Stability | ±1 °C |
| Maximum Pressure | 5 bar (with quartz window) |
| Sample Diameter | 7 mm |
| Sample Mass | 70–100 mg |
| Gas Inlet | 1/16″ stainless steel high-pressure tubing |
| Working Distance for Objective Lens | 6 mm |
| Window Compatibility | Reflectance microscopy, Raman spectroscopy, FTIR |
| Cooling | Integrated water-cooled jacket |
| Construction Materials | Non-reactive ceramics, inert ceramic fiber filter, quartz or sapphire optical windows |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CMS196 |
| Temperature Range | Ambient to −196 °C |
| EM Grid Compatibility | Standard TEM grids, Bessy, Planchette, FEI, Polara formats |
| Motorized XY Stage Resolution | 1 µm |
| Integrated Condenser | For transmitted light and phase contrast |
| LN₂ Hold Time | 30 min (standard Dewar) / 6 h (optional 3 L Dewar) |
| Startup Time | ≤10 min |
| Sample Drift | <1 nm over 10 min |
| Stage Architecture | Decoupled sample holder–Dewar mechanical interface |
| Automation | Magnetic sample cartridge auto-alignment system (up to 3 samples) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CSS450 |
| Temperature Range | −50 °C to 450 °C |
| Temperature Accuracy & Stability | ±0.1 °C |
| Optical Aperture Diameter | 2.5 mm |
| Sample Heating Area | 30 mm |
| Max. Heating/Cooling Rate | 30 °C/min |
| Minimum Objective/Condenser Working Distance | 7.4 mm / 11.5 mm |
| Shear Modes | Oscillatory, Steady, Step |
| Shear Rate Range | 0.003–7500 s⁻¹ |
| Gap Control Range | 5–2500 µm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FTIR600 |
| Temperature Range | −196 °C to 600 °C |
| Temperature Stability | < 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Optical Aperture Diameter | 2.4 mm |
| Sample X–Y Translation Range | 16 mm |
| Heating Area | 22 mm² |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Window Thickness (CaF₂) | 0.17 mm |
| Condenser Angle | 85° |
| Objective Angle | 116° |
| Minimum Working Distance (Objective/Condenser) | 4.5 mm / 12.5 mm |
| Chamber | Sealed, Gas-Purged Compatible |
| Dimensions (L×W×H) | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTS420 |
| Temperature Range | −196 °C to 420 °C (liquid nitrogen cooling optional) |
| Temperature Stability | < 0.1 °C |
| Max Ramp Rate | 0.1–50 °C/min |
| Sample Area | 53.5 × 43 mm |
| XY Translation | 15 × 15 mm |
| Optical Aperture | 2.5 mm |
| Minimum Objective Working Distance | 6 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Dimensions (Stage Only) | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTSE420 |
| Temperature Range | Ambient to +420 °C (with optional cryo-cooling: down to −196 °C) |
| Temperature Stability | <0.01 °C |
| Temperature Resolution | 0.01 °C |
| Electrode Configuration | Standard dual-electrode |
| Optical Aperture | Ø2.4 mm |
| Sample XY Translation | 15 × 15 mm |
| Stage Surface Area | 53.5 × 43 mm |
| Compatible Sample Holders | Standard 76 × 26 mm microscope slides or Ø16 mm coverslips |
| Heating Rate | 0.1–50 °C/min |
| Minimum Objective Working Distance | 6.0 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Stage Dimensions | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | MFS350 |
| Temperature Range | −195 °C to 350 °C |
| Sample Width | 0.001–22 mm |
| Sample Thickness | 0.001–2 mm |
| Minimum Sample Length | 26 mm |
| Tensile Speed | 1–5000 µm/s |
| Force Range | 0.01–20 N or 0.1–200 N |
| Force Resolution | 0.01 N or 0.1 N |
| Maximum Travel | 85 mm |
| Position Resolution | 1 µm |
| Objective Working Distance | 7.5 mm |
| Condenser Working Distance | 12.5 mm |
| Temperature Ramp Rate | 0.1–60 °C/min |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | PE100 |
| Temperature Range | −5 °C to 99 °C |
| Ramp Rate | ±10 °C/min |
| Temperature Accuracy & Stability | ±0.1 °C (full range) |
| Viewing Aperture Diameter | 16 mm |
| Sample Area Diameter | 108 mm |
| Minimum Objective Working Distance | 0.1 mm |
| Heating Element | Pt100-resistive |
| Control Interface | Integrated LCD touchscreen |
| Power Supply | DC |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | PE120 |
| Temperature Range | −25 °C to +120 °C |
| Heating/Cooling Rate | 0.1–20 °C/min |
| Stage Aperture Diameter | 5 mm |
| Sample Area | 35 × 32 mm |
| Temperature Stability & Accuracy | ±0.1 °C |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Control Interface | LCD Touchscreen |
| Minimum Objective Working Distance | 0.1 mm |
| Minimum Condenser Working Distance | 5 mm |
| Stage Dimensions (PE120XY) | 160 × 110 mm |
| Cooling Method | External Recirculating Chiller (ECP Series) |
| Compatibility | Olympus BX, Nikon Ni-E/Ni-U, Zeiss Axio Imager/Axioskop with Optional Mount Adapters |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS600 |
| Temperature Range | –196 °C to +600 °C |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Temperature Stability | <0.01 °C |
| Temperature Accuracy | ±0.1 °C (full range) |
| Sample Area Diameter | 22 mm |
| Optical Aperture Diameter | 2.0 mm |
| X/Y Translation Range | 16 mm each axis |
| Upper Window Thickness | 0.17 mm (coverslip-grade fused silica) |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Dimensions (Stage Body) | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSE600 |
| Temperature Range | −196 °C to +600 °C (−196 °C requires optional liquid nitrogen cooling system) |
| Temperature Stability | < 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Optical Aperture Diameter | 2.4 mm |
| Sample XY Translation Range | 15 × 15 mm |
| Sample Area | 22 mm diameter |
| Electrode Configuration | Standard dual-electrode |
| Electrode Integration | Embedded in sealed chamber, compatible with conductive glass LC cells |
| Chamber Environment Control | Vacuum, inert gas (N₂, Ar), or humidity-controlled atmosphere |
| Window Thickness | 0.17 mm |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Stage Dimensions | 137 × 92 × 22 mm |
| Compatible Sample Format | 16 mm diameter cover slips with capillary-filled LC cells (5 µm cell gap) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSG600 |
| Temperature Range | −195 °C to +600 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Stability | <0.01 °C |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample XY Travel | 16 mm |
| Heating Area Diameter | 22 mm |
| Window Thickness | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Dimensions | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1200 |
| Temperature Range | Ambient to 1200 °C |
| Temperature Accuracy & Stability | ±1 °C |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | Ø10 × 5 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Key | Brand: Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1400XY |
| Temperature Range | Ambient to 1400 °C |
| Heating Rate | 1–200 °C/min |
| Temperature Stability | ±1 °C |
| XY Translation Range | X = 4 mm, Y = 10 mm |
| Thermocouple Type | S-type (Pt-10% Rh / Pt) |
| Maximum Sample Size | 5 × 5 × 0.5 mm |
| Minimum Objective Working Distance | 6 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Optical Aperture | 1.7 mm |
| Gas-Tight Chamber | Yes |
| Cooling | Dedicated Water-Circulation System |
| Dynamic Thermal Response | Fast heating and cooling with real-time control |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1500 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy & Stability | ±1 °C over full range |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | φ7 × 6 mm or φ7 × 3 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Vacuum Compatibility | Down to 10⁻³ mbar |
| Brand | Linos |
|---|---|
| Origin | Germany |
| Model | newopto |
| Wavelength Range | 355–1064 nm |
| Expansion Ratio | 2×–8× (variable, manual or motorized) |
| Max. Input Beam Diameter (1/e² Gaussian) | 3.4–8 mm |
| Max. Output Beam Diameter | 31 mm |
| Number of Lens Elements | 4 |
| Entrance Lens Material | Fused Silica (Quartz) |
| Mounting Diameter | 37.6 mm |
| Compliance | ISO 10110 optical surface specifications, RoHS-compliant housing |
| Brand | LINOS |
|---|---|
| Origin | Germany |
| Product Category | Optical Component |
| Crystal Types | KD*P, BBO, RTP, LiNbO₃ |
| Aperture Diameter | Ø2.6–Ø15 mm |
| Transmission | 84–99% |
| Extinction Ratio (Zero Voltage) | 100:1–3000:1 |
| Half-Wave Voltage (at 1064 nm) | 1.8–8 kV |
| Capacitance | 3.6–6.0 pF |
| Damage Threshold | >100–600 MW/cm² (1064 nm, 10 ns, 1 Hz) |
| Wavefront Distortion | <λ/4 |
| Mounting Compatibility | Up to 35 mm cell diameter |
| Operating Modes | Standard, Water-Immersion (IM), Sol-Gel (SG) |