| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | ARIAS 500 |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index (RI) Range | 1.30000–1.70000 |
| RI Accuracy | ±0.00005 |
| Brix Range | 0.00–95.00% |
| Brix Accuracy | ±0.03% |
| Light Source | 589 nm LED |
| Temperature Control Range | 10–80 °C |
| Temperature Stability | ±0.01 °C |
| Detection Method | Dual-channel linear CCD array |
| Prism Material | Optical glass sealed with epoxy and 416 stainless steel sample well |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | Brake-Chek |
| Type | Handheld Refractometer |
| Temperature Control | Yes (ATC) |
| Digital Display | Yes |
| Measurement Range | 121–260 °C (for DOT3), up to 299 °C (DOT3HT), 125–275 °C (DOT4), 150–275 °C (DOT4 Plus) |
| Accuracy | ±1 °C |
| Light Source | 589 nm LED |
| Dimensions | 54 × 27 × 100 mm |
| Weight | 100 g |
| Power | 2 × AAA batteries (included) |
| Battery Life | ~10,000 measurements |
| Auto-off & Sleep Mode | Yes |
| IP Rating | IP65 |
| Compliance | CE, RoHS, WEEE |
| Warranty | 1 year |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | Brix/RI-Chek |
| Product Type | Handheld Refractometer |
| Temperature Control | Yes (ATC) |
| Digital Display | Yes (5-digit full-view LCD) |
| Refractive Index Range | 1.3330 – 1.4465 |
| RI Accuracy | ±0.0002 |
| Brix Range | 0.0 – 62.0% |
| Brix Accuracy | ±0.2% |
| Prism Material | Optical Glass |
| Dimensions | 54 × 27 × 100 mm |
| Weight | 100 g |
| IP Rating | IP65 |
| Certifications | CE, RoHS, WEEE |
| Warranty | 1 year |
| Order Code | 13940000 |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | DEF-Chek |
| Product Type | Handheld Digital Refractometer |
| Temperature Compensation | Automatic (ATC, 20 °C reference) |
| Display | Digital LCD |
| Measurement Range | 0.0 – 50.0% w/w urea in deionized water |
| Accuracy | ±0.1% w/w |
| Light Source | 589 nm LED (sodium-D line equivalent) |
| Dimensions | 54 × 27 × 100 mm |
| Compliance | Designed for ASTM D7596, ISO 22241-2, and US EPA/ULEV regulatory verification protocols |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | EG-Chek |
| Product Type | Handheld Digital Refractometer |
| Temperature Control | Yes (ATC) |
| Digital Display | Yes |
| Measurement Range | 0–95% EG concentration, −57 °C to +57 °C ice point, 117–180 °C boiling point |
| Accuracy | ±0.2% EG concentration, ±0.6 °C for temperature parameters |
| Light Source | 589 nm LED |
| Dimensions | 54 × 27 × 100 mm |
| Weight | 100 g |
| Power | 2 × AAA batteries (included) |
| Battery Life | ~10,000 measurements |
| Auto-off & Sleep Mode | Yes |
| IP Rating | IP65 |
| Compliance | CE, RoHS, WEEE |
| Warranty | 1 year |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | Mark III |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3106–1.7000 nD |
| Refractive Index Accuracy | ±0.0001 nD |
| Brix Range | 0.0–95.0 %Brix (ICUMSA) |
| Brix Accuracy | ±0.1 % |
| Light Source | High-intensity, long-life LED at 589 nm |
| Temperature Control Range | 10–80 °C |
| Temperature Stability | ±0.01 °C |
| Prism Material | Optical glass prism sealed with epoxy resin and 416 stainless steel sample well |
| Display | LCD, 44 × 44 mm active area |
| Interface | RS-232, user-configurable baud rate up to 57600 |
| Calibration History Storage | Hundreds of entries |
| Auto Thermal Equilibrium Detection | Yes |
| Password Protection | For method setup and menu parameters |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | Multi-Chek |
| Type | Handheld Digital Refractometer |
| Temperature Control | Yes (ATC) |
| Display | Digital LCD |
| Measurement Range | EG freeze point: 0 to –57 °C |
| PG freeze point | 0 to –51 °C |
| Battery electrolyte SG | 1.000–1.463 |
| Windshield washer fluid freeze point | 0 to –54 °C |
| Accuracy | ±0.3 °C (EG/PG), ±0.003 SG (battery), ±1 °C (washer fluid) |
| Light Source | 589 nm LED |
| ATC Reference | 20 °C |
| IP Rating | IP65 |
| Compliance | CE, RoHS, WEEE |
| Power | 2 × AAA batteries (included) |
| Battery Life | ~10,000 measurements |
| Dimensions | 54 × 27 × 100 mm |
| Weight | 100 g |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | Multi-Chek7 |
| Type | Handheld Digital Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | Engine Coolant Freeze Point: 0 to –57 °C |
| Coolant Concentration | 0–95% |
| AdBlue/DEF Concentration | 0–50% |
| Windshield Washer Fluid Freeze Point | 0 to –54 °C |
| Battery Electrolyte Specific Gravity | 1.000–1.463 SG |
| DOT4 Brake Fluid Boiling Point | 125–275 °C |
| DOT4 Plus Boiling Point | 150–275 °C |
| Accuracy | ±0.3 °C (freeze point), ±1% (concentration), ±0.1% (AdBlue), ±1% (washer fluid freeze point), ±0.003 SG (electrolyte), ±3 °C (brake fluid boiling point) |
| Dimensions | 54 × 27 × 100 mm |
| Weight | 100 g |
| IP Rating | IP65 |
| Compliance | ASTM D1120, ISO 2808, CE, RoHS, WEEE |
| Power | 2 × AAA batteries (included) |
| Battery Life | >10,000 measurements |
| Auto-off & Sleep Mode | Yes |
| Warranty | 1 year |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | PG-Chek |
| Type | Handheld Digital Refractometer |
| Temperature Control | Yes (ATC) |
| Display | Digital LCD |
| Measurement Range | 0–95% PG concentration |
| Accuracy | ±0.2% PG |
| Ice Point Range | 0–51°C (±0.6°C) |
| Boiling Point Range | 117–174°C (±0.6°C) |
| Light Source | 589 nm LED |
| ATC Reference | 20°C |
| IP Rating | IP65 |
| Compliance | CE, RoHS, WEEE |
| Power | 2×AAA batteries (included) |
| Battery Life | ~10,000 measurements |
| Dimensions | 54 × 27 × 100 mm |
| Weight | 100 g |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | R2i300 |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3330–1.5600 nD |
| Brix Range | 0.0–95.0% |
| RI Accuracy | ±0.0001 nD |
| Brix Accuracy | ±0.1% |
| Light Source | High-intensity LED, 589 nm |
| Prism Material | Sapphire |
| Sample Chamber | PTFE-lined 416 stainless steel |
| Auto Temperature Compensation (ATC) | Yes |
| Calibration Modes | Fixed-point and user-defined range/point |
| Display | LCD, 11 × 6 cm |
| Predefined Measurement Modes | 7 |
| Brand | Reichert |
|---|---|
| Origin | USA |
| Model | Rhino Duo-Chek |
| Type | Handheld Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Freezing Point Range | 0 to –48 °C |
| Accuracy | ±0.55 °C |
| Specific Gravity Range | 1.100–1.400 (Resolution: 0.01) |
| Ethylene Glycol Concentration Range | 0–70% |
| Propylene Glycol Concentration Range | 0–61% |
| Refractive Index Range | 1.3330–1.4048 |
| Calibration Fluid | Distilled Water |
| Compliance | ASTM D3321-94 (2002) |
| Brand | REO (Research Electro-Optics) |
|---|---|
| Origin | USA |
| Type | Gas Laser System |
| Wavelength | 633 nm |
| Output Power Range | 0.5–35 mW |
| Polarization | Linear (>500:1) or Unpolarized |
| Beam Mode | TEM₀₀ |
| Power Rise Time | ≤3 s to 75% of rated output |
| Beam Diameter | 0.57–1.22 mm |
| Beam Divergence | 0.66–1.41 mrad |
| Longitudinal Mode Spacing | 163–1082 MHz |
| Frequency Stability (Stabilized Models) | ±1 MHz (1 hr), ±2 MHz (8 hr) |
| Power Stability (Stabilized Models) | ±0.1% (1 min), ±0.2% (1 hr) |
| Orthogonal Polarization Option | Dual-output, orthogonal linear polarization (Δθ = 90°, >500:1 extinction ratio) |
| Optional Wavelengths | 543 nm, 594 nm, 604 nm, 612 nm, 1.15 µm, 1.52 µm, 3.39 µm, dual-wavelength (e.g., 633/1.52 µm) |
| Brand | Resolution Spectra Systems |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectraResolver |
| Core Hardware Integration | SWIFTS-based laser spectrometers (Zoom Spectra & Micro Spectra platforms) |
| Supported Light Sources | Semiconductor laser diodes and multi-mode laser systems |
| Calibration Reference | Temperature-stabilized internal reference for absolute wavelength accuracy |
| Wavelength Accuracy | Sub-picometer (pm) level for multi-mode lasers under controlled thermal conditions |
| Data Acquisition Modes | High-frame-rate burst capture and low-frame-rate long-term monitoring |
| Native Data Compatibility | Zoom Spectra and Micro Spectra spectral acquisition units |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RF-1 |
| Pricing | Upon Request |
| Dimensions | 200 mm (W) × 90 mm (H) × 75 mm (D) |
| Weight | 820 g (without batteries) |
| Housing Material | Sheet Metal |
| Power Supply | 4 × AA alkaline batteries (Ni-Cd rechargeable compatible) |
| Display | 16-character × 2-line LCD |
| Operation Keys | 4 tactile buttons |
| Illumination/Viewing Geometry | 0°/45° |
| Light Source | Tungsten-halogen lamp |
| Detector | Silicon photodiode array |
| Measurement Aperture | 10 mm diameter |
| Sample Holders | Glass cuvette, glass plate, solid test plate |
| Sample Types | Powders, liquids, transparent viscous pastes, clay-like solids, hydrated solids (*with optional plastic film or transparent bag) |
| Standard White Tile | Removable, mounts directly onto glass cuvette |
| Output Color Spaces | CIE XYZ, CIE L*a*b*, CIELAB, Whiteness (WB), ISO Brightness (W), Tint (Tw) |
| Color Differences | ΔXYZ, ΔL*a*b*, ΔE*ab, ΔE*00, ΔWB, ΔW, ΔTw (*WB valid only under C/2° |
| Display Resolution | 0.1 unit |
| Repeatability | ΔE*ab ≤ 0.1 (SD of 20 measurements on certified white tile) |
| Instrument Accuracy | ΔE*ab ≤ 1.0 (mean error across NIST-traceable R/G/B/Y ceramic tiles) |
| Observer Angle | 2° (C illuminant), 10° (D65 illuminant) |
| Calibration Method | Reflectance-based, using factory-certified white tile with XYZ input |
| Reference Standard | Single user-defined reference |
| Averaging Function | Up to 9 consecutive readings |
| Battery Indicator | Multi-segment real-time level display |
| Auto Power-Off | After 5 minutes of inactivity |
| Interface | RS-232C serial port (9600 bps), 8-pin circular DIN connector |
| Standard Accessories | Glass cuvette, glass calibration plate, solid test plate, removable white calibration tile, light-shielding hood, printed operation manual |
| Optional Accessories | Thermal printer, RS-232 cable, protective carrying case |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | Rhopoint IQ-S |
| Instrument Type | Handheld, Automatic |
| Haze Range | 0–90% |
| Transmittance Range | 0–100% |
| Haze Repeatability | ±0.2% |
| Transmittance Repeatability | ±0.2% |
| Measurement Angles | 20°, 60°, 85° (angle-selectable per surface finish) |
| Key Metrics | Gloss, Peak Gloss, Reflectance Haze, Reflectance Image Quality (RIQ), DOI (Distinctness of Image) |
| Brand | Rhopoint |
|---|---|
| Origin | United Kingdom |
| Model | IQ20/60/85 |
| Gloss Angles | 20°, 60°, 85° |
| Gloss Range | 0–100 GU and 100–2000 GU |
| Gloss Resolution | 0.1 GU |
| Gloss Repeatability | ±0.2 GU or ±0.2% |
| Gloss Reproducibility | ±0.5 GU or ±0.5% |
| Haze Range | 0–30 HU (LogHU optional) |
| Haze Resolution | 0.1 HU |
| Haze Repeatability | ±0.5 HU |
| Haze Reproducibility | ±1.5 HU |
| DOI (Distinctness of Image) Range | 0–100 |
| DOI Resolution | 0.1 |
| DOI Repeatability | ±0.2 |
| DOI Reproducibility | ±0.5 |
| Transmittance Range | 0–100% |
| Transmittance Repeatability | ±0.1% |
| Power | Rechargeable Li-ion battery (17+ hours runtime, 20,000+ measurements) |
| Data Storage | 8 MB internal memory (>999 readings with user-defined labels) |
| Interface | Full-color capacitive touchscreen, USB-C connectivity, no driver installation required |
| Compliance | ISO 2813, ASTM D523, ASTM D2457, DIN 67530, JIS Z8741 (gloss) |
| Brand | Rhopoint |
|---|---|
| Origin | United Kingdom |
| Model | NG206085 NOVO-GLOSS 20/60/85 |
| Type | Manual Portable Gloss & Haze Meter |
| Haze Range | 0–30% |
| Transmittance Range | 0–100% |
| Haze Repeatability | ±0.2% |
| Transmittance Repeatability | ±0.1% |
| Gloss Measurement Angles | 20°, 60°, 85° |
| Gloss Range | 0–100 GU (standard), 100–2000 GU (extended) |
| Gloss Resolution | 0.1 GU |
| Gloss Repeatability | ±0.2 GU |
| Gloss Reproducibility | ±0.5 GU |
| Compliance | ISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z 8741 |
| Measurement Areas | 20°: 6 mm × 6.4 mm, 60°: 6 mm × 12 mm, 85°: 4.4 mm × 44 mm |
| Operating Temperature | 15–40 °C |
| Operating Humidity | <85% RH, non-condensing |
| Dimensions | 65 mm (H) × 140 mm (W) × 50 mm (D) |
| Weight | 530 g |
| Battery Life | >17 hours / >14,000 readings per charge |
| Internal Storage | 8 MB (>2000 readings) |
| Data Transfer | Bluetooth 4.0, USB interface, no driver required |
| Display | Full-color adjustable-brightness touchscreen |
| Calibration | Integrated positioning-detect calibration base with certified reference tiles |
| Brand | Rhopoint |
|---|---|
| Origin | United Kingdom |
| Model | NOVO-CURVE |
| Measurement Angle | 60° |
| Measurement Range | 0–1000 GU |
| Repeatability | ±0.2 GU (<200 GU) |
| Reproducibility | ±0.5 GU (<200 GU) |
| Aperture Diameter | 4.5 mm |
| Measured Area | 2 × 2 mm |
| Data Storage Capacity | 199 readings |
| Weight | 2.5 kg |
| Dimensions | 160 × 220 × 100 mm |
| Power Supply | 110–120 V AC or 220–240 V AC |
| Compliant Standards | ASTM D523, ISO 2813 |
| Language Support | English, French, German, Italian, Spanish, Dutch |
| Brand | Rhopoint |
|---|---|
| Origin | United Kingdom |
| Model | NOVO-GLOSS 60 |
| Gloss Measurement Angle | 60° |
| Haze Range | 0–30% |
| Transmittance Range | 0–100% |
| Haze Repeatability | ±0.2% |
| Transmittance Repeatability | ±0.1% |
| Compliance | ISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z 8741 |
| Display | Full-color TFT touchscreen |
| Battery Life | >17 hours / >14,000 readings per charge |
| Data Storage | 8 MB (≥2,000 readings) |
| Connectivity | Bluetooth 4.2, USB Type-B |
| Measurement Area (60°) | 6 mm × 12 mm |
| Operating Temperature | 15–40 °C |
| Operating Humidity | <85% RH, non-condensing |
| Dimensions (H×W×D) | 65 × 140 × 50 mm |
| Weight | 390 g |
| Brand | Rhopoint |
|---|---|
| Origin | United Kingdom |
| Model | Novo-Shade Duo+ |
| Reflectance Repeatability | 0.2% |
| Reflectance Accuracy | ±0.1 |
| Measurement Geometry | 0°/45° |
| Display | Full-color LCD with adjustable brightness |
| Interface | 6 capacitive touch keys |
| Construction | Anodized aluminum housing, tempered glass front panel, integrated calibration stand with position detection |
| Data Storage | 8 MB (up to 999 readings), user-definable batch names |
| Connectivity | Bluetooth 4.2, USB Type-A (driver-free PC connection) |
| Battery | Rechargeable Li-ion, ≥17 hours continuous operation, ≥20,000 measurements per charge, 4-hour full recharge |
| Operating Environment | 15–40 °C, ≤85% RH non-condensing |
| Dimensions | 65 mm (H) × 140 mm (L) × 50 mm (W) |
| Weight | 790 g |
| Compliance | ISO 2814, ISO 6504, BS 3900-D4 & D7, ASTM E97, E1347, D4214, D2805, D589 |
| Brand | Hengjiu |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rincon |
| Wavelength Range | 700–1500 nm |
| Dynamic Range | 10⁸ (10⁴ in measurement window) |
| Temporal Scan Range | 950 ps |
| Input Pulse Energy | < 500 µJ (for 40–50 fs pulses) |
| Minimum Pulse Width | > 20 fs |
| Repetition Rate | < 100 Hz |
| Input Polarization | Linear, Horizontal |
| Temporal Resolution | 150 fs (2 ps time window), 400 fs (12 ps time window) |
| Power Supply | 220 V, 50/60 Hz ±10% |
| Origin | Denmark |
|---|---|
| Manufacturer | Risø National Laboratory (Technical University of Denmark) |
| Type | TL/OSL Reader System |
| Model | DA20 C/D |
| Power Supply | 100–240 V, 50/60 Hz, 120 W |
| Heating Range | Room temperature to 700 °C |
| Heating Rate | 0.1–10 K/s |
| TL Detection | PMT with U-340, BG-39, and Corning 7-59 filters |
| OSL Excitation | Blue LED (470 nm, ≥50 mW/cm²), IR LED (870 nm, ≥140 mW/cm²), optional green laser (532 nm, 50 W/cm²) |
| Irradiation Sources | ⁹⁰Sr/⁹⁰Y β-source (1.48 GBq, ~0.1 Gy/s on quartz), ²⁴¹Am α-source (10.7 MBq, ~45 mGy/s on quartz), X-ray tube (Varian VF-50J, 50 kV/1 mA, dose rate 10 mGy/s–2 Gy/s with 50 mm Al filtration) |
| Sample Capacity | Up to 48 positions |
| Vacuum & N₂ Cooling | Integrated for TL measurement |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TL/OSL-DA-20 |
| Heating Range | RT–700 °C (programmable ramp rate: 0.1–10 K/s) |
| TL Detection | PMT with U-340/BG39/7-59 filter set |
| OSL Excitation Sources | 470 nm blue LED (≥50 mW/cm²), 870 nm IR LED (≥140 mW/cm²), optional 532 nm green laser (50 W/cm²) or 830 nm IR laser (~500 W/cm²) |
| Irradiation Options | β (⁹⁰Sr/⁹⁰Y, 1.48 GBq, ~0.1 Gy/s on quartz), α (²⁴¹Am, 10.7 MBq, ~45 mGy/s on quartz), X-ray (Varian VF-50J, 50 kV/1 mA, 10 mGy/s–2 Gy/s with 50 mm Al filtration) |
| Sample Capacity | 48-position programmable carousel |
| Vacuum & N₂ cooling | Integrated sample chamber with controlled purge and rapid post-heating quenching |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TL/OSL-DA20 C/D |
| Price Range | USD 0–7,200 (est. based on ¥0–50,000) |
| Brand | RJS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D4000 |
| Pricing | Available Upon Request |
| Brand | Roadvista |
|---|---|
| Origin | USA |
| Model | ROADVISTA 932 |
| Measurement Range | 0–20,000 cd·lx⁻¹·m⁻² |
| Measurement Accuracy | ±0.001% (RA) |
| Incident Angle Adjustment | −45° to +45° (continuous) |
| Observation Angle Adjustment | 0.2° to 2.0° (continuous) |
| Aperture Angle (Source & Detector) | 0.1° |
| Test Area Diameter | 25 mm |
| Colorimetric Compliance | CIE 1931 xy chromaticity coordinates (retroreflected) |
| Data Storage Capacity | >32,000 measurements |
| Interface | USB 2.0 + Bluetooth 4.2 |
| Power Supply | Removable 12 VDC, 2.4 Ah Li-ion battery |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Dimensions | 380 × 115 × 325 mm |
| Weight | 2.9 kg (with battery) |
| Standards Compliance | ASTM E1709, ASTM E2540, ASTM D4956, EN 12899, EN 471, ANSI/ISEA 107, ISO 20471, GB/T 28648, GB 20653, GB/T 28468–2012 |
| Brand | TEO |
|---|---|
| Origin | Israel |
| Model | RTP |
| Type | Electro-Optic Q-Switch & Phase/Amplitude Modulator |
| Operating Temperature Range | −50 °C to +70 °C |
| Crystal Structure | Rhombohedral (Space Group R3c) |
| Electro-Optic Coefficient | r₄₁ ≈ 11.8 pm/V (at 1064 nm) |
| Half-Wave Voltage (Vπ) | < 3.5 kV (for standard 25 mm aperture, λ = 1064 nm) |
| Laser Damage Threshold | > 1 GW/cm² (10 ns, 1064 nm, 10 Hz) |
| Insertion Loss | < 0.2 dB per surface (AR-coated, 1064 nm) |
| Extinction Ratio | > 30 dB (with precision bias control) |
| Hygroscopicity | Non-hygroscopic |
| Ringing Effect | Negligible (τ < 1 ns step response) |
| Brand | SYNOPTICS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Ruby |
| Price Range | USD $0 – $7,200 (FOB) |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | AUTOPOL 589 |
| Measurement Wavelength | 589 nm |
| Wavelength Switching | Manual or Optional Motorized |
| Measurement Range | ±225°Z |
| Resolution | 0.01°Z |
| Optical Element | Calcite Prism |
| Temperature Control Accuracy | ±0.1°C |
| Calibration | One-Touch Auto-Calibration |
| Measurement Modes | Sucrose Concentration (°Z), Optical Rotation (°), Purity, User-Defined Units |
| Compliance | SPRI Certified |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | AUTOPOL 880 |
| Measurement Wavelengths | 589 nm and 880 nm |
| Wavelength Switching | Automatic |
| Optical Rotation Range | ±225°Z |
| Resolution | 0.01°Z |
| Optical Element | Calcite Prism |
| Temperature Control Range | 20–40 °C |
| Temperature Accuracy | ±0.1 °C |
| Calibration | One-Touch Auto-Calibration |
| Measurement Modes | Sucrose Concentration (°Z), Specific Rotation (°), Purity, or User-Defined Parameters |
| Sample Type | Non-Destructive Analysis |