Other General Analytical Instruments
Filter
Showing 121–150 of 382 results
| Brand | ENSOUL |
|---|---|
| Model | MHSS-2 |
| Sample Positions | 2 |
| Heating Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±3 °C |
| Timer Range | 0–999 min |
| Power Supply | AC 220 V |
| Power Consumption | 420 W |
| Compatibility | PEN-series electronic nose systems |
| Application | Headspace volatile profiling for sensory intelligent analysis |
| Brand | ENSOUL |
|---|---|
| Model | MHSS-9 |
| Sample Positions | 9 |
| Heating Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | AC 220 V |
| Power Consumption | 650 W |
| Compatibility | PEN-series electronic nose instruments |
| Origin | Beijing, China |
| Brand | EPROI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SiriusT3 |
| Price Range | USD 280–425 |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Fideris |
| Pricing | Upon Request |
| Brand | CNI (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FB-25 / FB-50 (Customizable) |
| Price | USD 285 (approx. ¥2016) |
| Compatibility | Standardized optical filter mounts for UV-Vis-NIR spectroscopy and photochemical applications |
| Brand | AWT |
|---|---|
| Origin | United Kingdom |
| Model | 1000 Series Fire Detector Test Chamber |
| Compliance | EN 54-7, EN 54-5, EN 14604, BS 5446-2, GB 4715-2024, GB 4716-2024 |
| Configuration Options | 1100 (smoke-only), 1300 (heat-only), 1400 (combined smoke/heat), 1700 (heat-only with active cooling), 1800 (combined smoke/heat with active cooling) |
| Form Factor | Benchtop |
| Application Domain | Factory QC, R&D Lab, Certification Testing |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | FLOWSTAR2020 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 270–1100 nm |
| Sample Volumes/Cup Capacity | 5 mL / 100 cups, 8 mL / 180 cups, 10 mL / 270 cups |
| Reagent Positions | 100, 180, or 270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | BreathSpec® |
| Sample Introduction | 6-port valve direct injection |
| Sensitivity | sub-ppb (pptv–ppbv range) |
| Spectral Library | Volatile Organic Compounds (VOCs) |
| Ionization Source | ³H beta emitter (300 MBq, exempt per IEC 61017 & GB 18871-2002 Annex A) |
| Drift Voltage Polarity | Switchable positive/negative mode |
| Detection Principle | Coupled Gas Chromatography–Ion Mobility Spectrometry (GC-IMS) |
| Data Acquisition | High-speed ADIO board with X-scale real-time processing |
| Display | 6.4″ TFT VGA screen |
| Connectivity | RS232 / USB-A ×2 / Ethernet (RJ45) |
| Power Input | 100–240 V AC, 50–60 Hz |
| Dimensions | 449 × 375 × 177 mm (W × D × H) |
| Weight | 15.5 kg |
| Enclosure | 19″ rack-mountable chassis, IP20 rated, EMC compliant |
| Cooling | Thermally regulated axial fan (max. 5.5 m³/h) |
| Gas Fittings | 3 mm stainless steel Swagelok® for drift gas, sample inlet/outlet, carrier gas, and IMS exhaust |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | FlavourSpec® 25 |
| Sample Introduction | Headspace Auto-sampling |
| Sensitivity | Sub-ppb (without preconcentration) |
| Spectral Output Formats | 2D ion mobility chromatograms, 3D retention time–drift time–intensity plots, and compound-specific fingerprint spectra |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Model | FlavourSpec®25 |
| Sample Introduction | Headspace (HS) |
| Sensitivity | <1 ppb (without preconcentration) |
| Data Output Formats | 2D chromatogram (GC × IMS), 3D spectrochromatogram, fingerprint plot |
| Detection Principle | Drift Tube Ion Mobility Spectrometry coupled with Capillary Gas Chromatography |
| Operating Pressure | Ambient atmospheric pressure |
| Instrument Architecture | Time-of-Flight (TOF)-based IMS detector with integrated thermal desorption and GC column |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | GC-IMS |
| Detection Limit | <1 ppb (v/v) |
| Sample Introduction | 6-port valve direct injection |
| Library | VOC-specific ion mobility spectral library |
| Operating Mode | Switchable positive/negative ion mode |
| Portability | Field-deployable, battery- and vehicle-power compatible |
| Compliance | Designed for ISO 16000-6, ASTM D5197, US EPA Method TO-15/TO-17 context |
| Brand | G.A.S. |
|---|---|
| Origin | Imported (Germany) |
| Model | GC-IMS |
| Injection Temperature | 150 °C |
| Sample Introduction | Direct gas-phase injection (manual or automated) |
| Sensitivity | Sub-ppbv detection for volatile organic compounds (VOCs) in liquid headspace or gaseous matrices |
| Library Support | Customizable fingerprint library for complex headspace profiles |
| Operational Mode | Switchable positive/negative ionization |
| Detection Speed | Full chromatographic–mobility separation cycle ≤15 min |
| Power Supply | DC 12–24 V (vehicle battery or rechargeable pack compatible) |
| Optional Module | CGFU Gas Circulation Unit (carrier-gas-free operation) |
| Compliance | Designed for field-deployable GLP-aligned workflows |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Redox Colorimetric Titration |
| Wavelengths | 650 nm (test), 810 nm (reference) |
| Range | 0–1,000 ppm (customizable) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% FS |
| Repeatability | ±1% FS |
| Analysis Cycle Time | 10 min |
| Sensitivity | 1% FS |
| Ambient Temperature | 20–60 °C (−4–140 °F) |
| Dimensions | 1016 mm H × 406 mm W × 241 mm D |
| Weight | 45.3 kg |
| Sample Interface | 1/4″ compression fitting |
| Sample Flow Rate | 200 mL/min |
| Max Sample Pressure | <5 psi |
| Max Suspended Solids | <1,000 µm |
| Power Supply | 24 VDC or 90–240 VAC |
| Analog Outputs | up to eight isolated 4–20 mA (self-powered) |
| Digital Inputs | 8 dry/wet contacts (24 VDC) |
| Ethernet | Embedded GUI via Modbus TCP/IP |
| Serial Protocols | Modbus RTU over RS-232/RS-485 |
| Alarm Outputs | User-configurable relay outputs |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Corrosion Resistance | H₂S- and Cl₂-resistant housing |
| Flow Path Architecture | Modular, scalable to 6 independent sample streams |
| Control Architecture | Physically segregated electronics and wet chemistry modules |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GASERA-F10 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GF-1800 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Model | ZF-1800A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Application Domain | Food Contact Material (FCM) Compliance Testing |
| Standards Compliance | GB 31604.8–2016, GB 31604.1–2015, GB/T 5009.156–2016, GB/T 9740–2008, GB/T 23949–2009, YBB00342002–2015, YBB00102005–2015, YBB00082002–2015 |
| Measurement Range | 0.167–167,000 mg/dm² |
| Resolution | 0.0001 mg/dm² |
| Balance Capacity | 0–200 g |
| Balance Readability | 0.1 mg |
| Water Bath Temp Control | 68.3–100 °C |
| Heating Chamber Temp Control | 68.3–117.9 °C |
| Cooling Chamber Temp Control | <27.5 °C |
| Temperature Accuracy | ±3 °C |
| Sample Throughput | 1–18 independent test positions |
| Gravimetric恒重 Cycle Time | 2.5 h (typical) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 1500 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800-2A |
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Category | Other General Analytical Instruments |
| Measuring Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent stations |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | ZF1800-A1 |
| Measuring Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent stations |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Dimensions (Solvent Recovery Unit) | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ZF1800-D |
| Price | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp. Control | RT–100 °C |
| Heating Chamber Temp. Control | RT–117.9 °C |
| Cooling Chamber Temp. Control | 10–35 °C |
| Temperature Accuracy | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800-F |
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Category | Other General Analytical Instruments |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Tester) | 178 × 93 × 145 cm (L×W×H) |
| Dimensions (Solvent Recovery Unit) | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800-S |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Other General Analytical Instruments |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ZF1800-T |
| Quotation | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | Ambient to 100 °C |
| Heating Chamber Temp Control | Ambient to 117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Accuracy | ±5 °C |
| Sample Positions | 1–18 (independent) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | General Analytical Instrument for Food Contact Materials Testing |
| Measurement Range | 0.167–167,000 mg/dm² |
| Resolution | 0.0001 mg/dm² |
| Balance Capacity | 0–200 g / Readability: 0.1 mg |
| Water Bath Temp Control | 68.3–100 °C |
| Heating Chamber Temp Control | 68.3–117.9 °C |
| Cooling Chamber Temp Control | <27.5 °C |
| Temp Accuracy | ±3 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporation Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1500 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800B |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic Instrument |
| Price | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZF1800B1 |
| Price | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent stations |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800C |
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Category | Other General Analytical Instruments |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | Ambient to 100 °C |
| Heating Chamber Temp Control | Ambient to 120 °C |
| Cooling Chamber Temp Control | Ambient |
| Temp Accuracy | ±0.5 °C |
| Chamber Temp Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Gravimetric Constant-Weight Duration | 2.5 h (standard) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 cm × 90 cm × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ZF1800D |
| Pricing | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | Ambient to 100 °C |
| Heating Chamber Temp Control | Ambient to 120 °C |
| Cooling Chamber Temp Control | Ambient |
| Temp Accuracy | ±0.5 °C |
| Chamber Temp Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Gravimetric Stabilization Time | 2.5 h (standard) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF3800A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Measuring Range | 0.167–167,000 mg/dm² |
| Resolution | 0.0001 mg/dm² |
| Balance Capacity | 0–200 g |
| Balance Readability | 0.1 mg |
| Water Bath Temp. Control | 68.3–100 °C |
| Heating Chamber Temp. Control | 68.3–117.9 °C |
| Cooling Chamber Temp. Control | <27.5 °C |
| Temperature Accuracy | ±3 °C |
| Sample Capacity | 1–18 independent test positions |
| Gravimetric Constant-Weight Duration | 2.5 h (standard) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | ZF800A |
| Testing Capacity | 8 independent stations (expandable to 36) |
| Residue Mass Range | 0–80 g |
| Weighing Accuracy | 0.2 mg |
| System Resolution | 0.1 mg |
| Temperature Control Range | 80–130 °C |
| Temperature Stability | ±0.2 °C |
| Hot Air Circulation Velocity | 0.2 m/s |
| Sample Volume per Vessel | 0–200 mL |
| Evaporation Vessel Capacity | 230 mL (included ×8) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 4000 W |
| Dimensions (W×D×H) | 937 × 660 × 830 mm |
| Interface Fittings | 1/8″ stainless steel tubing & Φ6 mm polyurethane tubing |
| Standard Accessories | Dedicated software, communication cable, 200 g calibration weight, Φ8 mm PU air tube |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | ZF800A |
| Measurement Range | 0–80 g (residue mass) |
| Accuracy | 0.1 mg |
| Resolution | 0.01 mg |
| Temperature Control Range | 80–150 °C (typical operating range: 100–130 °C) |
| Temperature Stability | ±0.1 °C (typical: ±0.2 °C) |
| Hot Air Circulation Velocity | 0.2 m/s |
| Sample Volume Capacity | 0–500 mL |
| Chamber Volume | 86 L |
| Independent Test Stations | 1–8 (expandable to 36) |
| Gas Supply | Compressed air |
| Pressure Requirement | 0.6 MPa |
| Tubing Interface | Φ6 mm polyurethane |
| Power Supply | AC 220 V, 50 Hz |
