Other General Analytical Instruments
Filter
Showing 91–120 of 382 results
| Brand | Bode Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BCODMn-60S |
| Pricing | Upon Request |
| Brand | Bode Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDCFA-800 |
| Pricing | Available Upon Request |
| Instrument Type | Continuous Flow Analyzer |
| [Brand | Boode |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDFIA-210 |
| Pricing | Upon Request] |
| Brand | BosinTech |
|---|---|
| Model | C-Nose |
| Origin | Shanghai, China |
| Manufacturer | Shanghai Bosin Industrial Development Co., Ltd. |
| Product Type | Sensory Intelligent Analysis System – Electronic Olfaction Analyzer |
| Detection Principle | Metal Oxide Semiconductor (MOS) Sensor Array-Based Volatile Organic Compound (VOC) Profiling |
| Sensor Count | 14 Independent MOS Sensors with Differential Selectivity |
| Detection Limit | Sub-ppb (parts-per-quadrillion equivalent sensitivity in optimized matrix) |
| Sample Analysis Time | 60–120 s |
| Sensor Response Time | <1 s |
| Architecture | Modular Air Chamber Isolation per Sensor |
| Configuration Options | Desktop, Portable, and Online Integration Versions |
| Data Analysis Framework | PCA, SIMCA, PLS-DA, DFA, PLS, and Hierarchical Clustering |
| Compliance Readiness | Supports GLP/GMP-aligned audit trails, 21 CFR Part 11-compliant software modules (optional), ISO 19957 (electronic nose performance validation), ASTM E2813 (odor discrimination testing protocols) |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | BreathSpec® |
| Inlet | 6-port valve direct injection |
| Sensitivity | sub-ppb (parts-per-trillion detectable) |
| Library | VOC-specific GC×IMS spectral library |
| Mobility Resolution | TOF-IMS with 5 kV/10 cm drift field |
| Weight | 20 kg |
| Integrated Components | Onboard computer, internal gas supply, spirometer for CO₂/O₂ flow monitoring |
| Sampling Modes | Direct exhaled breath, static headspace (oral/nasal cavity), dermal micro-sampling |
| Brand | Brookdale |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | BDFIA-7000 |
| Pricing | Upon Request |
| Brand | Brookdale Instruments |
|---|---|
| Model | BDFIA-9000 |
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Pricing | Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | BDFIA-100 |
| Pricing | Available upon Request |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDFIA-8000 |
| Pricing | Upon Request |
| Instrument Type | Flow Injection Analyzer |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDFIA-8000 |
| Price | Upon Request |
| Instrument Type | Flow Injection Analyzer |
| Wavelength Range | 200–900 nm |
| Sample Rack Capacity | 10-position or 40-position options |
| Reagent Positions | 11 |
| Flow Cell Path Length | 10 mm |
| Light Source | 5 V Halogen Lamp |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDFIA-8600/C |
| Product Type | Flow Injection Analyzer |
| Design | Integrated Channel-Based FIA System |
| Detection Principle | Coupled Online Sample Pretreatment + UV-Vis Spectrophotometry |
| Automation Level | Fully Automated, Computer-Controlled Sequential Analysis |
| Safety Features | Real-time Leak Detection, Waste Container Overflow Alarm, Liquid-Level Tracking Sensors |
| Compliance Context | Designed to support ASTM D3370, ISO 15681-2, EPA Method 354.1, and GB/T 5750–2023 workflows |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Instrument |
| Model | K-446 / K-449 |
| Power | 2300 W |
| Heating Positions | 20 |
| Temperature Range | 30–450 °C |
| Temperature Accuracy | ±1 °C |
| Display | LCD |
| Automation Level | Semi-Automatic (K-446) / Fully Automatic (K-449) |
| Acid Vapor Containment | Integrated Sealed Block Design |
| Sample Tube Material | High-Purity Borosilicate Glass (BUCHI Certified) |
| Safety Features | Dual Temperature Limiting per Stage |
| User Interface | Programmable Multi-Stage Temperature Profiles with Countdown Timer and Real-Time Temperature Feedback |
| Brand | CEL (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CEL-CPPCF Fluidized-Bed Heat-Exchange Reaction System (Custom-Engineered) |
| Pricing | Available Upon Request |
| Dimensions | 1690 mm × 800 mm × 2543 mm |
| Reactor Material | 310S Stainless Steel |
| Tubing Material | 316L Stainless Steel |
| Vaporizer Temp. Range | 0–800 °C |
| Steam Preheater Temp. Range | 0–950 °C |
| Reactor Temp. Range | 0–950 °C |
| Tubing Trace Heating Range | 0–200 °C |
| Operating Pressure | Atmospheric |
| Max. Liquid Flow Rate (Fully Vaporized) | ≤100 mL/min |
| Catalyst Bed Volume | <1500 mL |
| Gas Flow Capacity | 0–100 SLPM (scalable to multiple gas streams) |
| Mass Measurement | 0–30 kg (0.1 g resolution) |
| Safety Systems | Proportional pressure relief valve, rupture disc, independent overtemperature alarms at all critical zones, interlocked shutdown logic |
| Brand | CEAULIGHT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | CEL-GPPCH Fixed-Bed Catalyst Evaluation Reactor System (Custom-Engineered) |
| Pricing | Upon Request |
| Frame Dimensions | 1130 mm × 550 mm × 1000 mm |
| Construction Material | ASTM A240 Grade 316L Stainless Steel |
| Reactor Temperature Range | 0–800 °C |
| Vaporization Zone Temperature Range | 0–300 °C |
| Tubing Trace Heating Range | 0–200 °C |
| Maximum Operating Pressure | < 10 MPa |
| Liquid Flow Rate Range | 0.1–5 mL/min |
| Catalyst Bed Volume Capacity | < 5 mL |
| Gas Flow Channels (Configurable) | 0–5 sccm |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | M2000SP-X |
| Humidity Range | <7–95 %RH (at 23 °C) |
| Humidity Accuracy | ±0.8 %RH (at 23 °C) |
| Temperature Range | 10–55 °C |
| Temperature Accuracy | ±0.15 °C (NVLAP-calibrated) |
| Humidity Stability | 0.2 %RH (at 23 °C) |
| Temperature Stability | 0.1 °C (at 23 °C) |
| Humidity Uniformity | 0.1 %RH @ 50 %RH / 23 °C |
| Temperature Uniformity | 0.1 °C @ 50 %RH / 23 °C |
| Equilibration Time | 3–5 min (at 23 °C) |
| External Gas Flow Rate | 3 L/min (with external recirculation) |
| Internal Chamber Dimensions (standard) | 250 × 200 × 100 mm |
| Optional Extended Chamber (M2000SP-XR) | 300 × 250 × 150 mm |
| Probe Diameter Options | 10, 12, 15, 18 mm |
| Calibration Certificate | NVLAP-accredited |
| Communication Interface | RS485 (optional), software-controllable or user-programmable |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TB 211 |
| Measurement Principle | ISO 7027-compliant 90° infrared light scattering (λ = 860 nm) |
| Range | 0.01–1100 NTU (auto-ranging) |
| Resolution | 0.01 NTU (0.01–9.99), 0.1 NTU (10.0–99.9), 1 NTU (100–1100) |
| Accuracy | ±2.5% or ±0.01 NTU (whichever is greater) for <500 NTU |
| Response Time | ~8 s per measurement |
| Display | Backlit LCD (button-activated) |
| Data Storage | 125 measurements |
| Interface | USB |
| Temperature Compensation | Yes |
| IP Rating | Waterproof cuvette compartment |
| Units | NTU, FNU, TE/F (equivalent per EN ISO 7027) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TB 300 |
| Measurement Principle | 90° Nephelometric Scattering |
| Light Source | Infrared LED (860 nm) |
| Calibration Standard | Formazine |
| Measurement Range | 0.01–1100 NTU (auto-ranging) |
| Resolution | 0.01 NTU (0.01–9.99), 0.1 NTU (10.0–99.9), 1 NTU (100–1100) |
| Accuracy | ±2% of reading or ±0.01 NTU (0–500 NTU) |
| Sample Volume | ~12 mL |
| Display | Graphical LCD with real-time clock |
| Data Storage | 1000 measurement records |
| Keypad | Acid- and solvent-resistant membrane keys |
| Auto Power-Off | Enabled |
| Compliance | ASTM D6508, ISO 7027, EPA Method 180.1 |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380Plus |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | Cleverchem 380Plus |
| Sample Capacity | 119 positions (expandable to 129) |
| Reagent Positions | 49 |
| Wavelength Range | 400–900 nm |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Detection Principle | Photometric Colorimetry (Discrete Flow Analysis) |
| Maximum Throughput | 350 samples/hour |
| Sample Volume Range | 1–900 µL |
| Reagent Volume Range | 1–450 µL |
| Dilution Factor | Up to 100× (in-cuvette) |
| Cuvette Material | Fused Quartz (64-position carousel) |
| Cleaning | 8-step Ultrasonic + WECO Peristaltic Pump System |
| Compliance | ASTM, ISO, EPA, and GB methods |
| Software | GLP-compliant with audit trail, sample/blank correction, and 21 CFR Part 11-ready configuration options |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem Anna |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 31 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Instrument Type | Discrete Analyzer (Flow-Based Spectrophotometric Analyzer) |
| Model | CleverChem F.U.V. |
| Wavelength Range | 200–850 nm |
| Sample Volume per Test | 10 mL |
| Reagent Positions | N/A (Reagent-free operation for core wine parameters) |
| Flow Cell Pathlength | 0.20 mm |
| Light Source | Deuterium + Tungsten-Halogen UV/Vis Lamp (2000 h lifetime) |
| FTIR Resolution | < 0.4 cm⁻¹ |
| UV-Vis Spectral Resolution | 0.25 nm |
| Detector | 2048-pixel CCD array (200 × 14 µm/pixel) |
| Temperature Control Range | 5–35 °C |
| Dimensions (Analyzer Unit) | 35 × 28 × 26 cm (W×D×H) |
| Weight | 10 kg |
| Compliance | Designed for GLP-compliant wine laboratories |
| Key | Origin: Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Model | DRY-3.5 |
| Quotation | Upon Request |
| Total Force | 3.50 ± 0.02 N |
| Plunger Tip Diameter | 3.15 ± 0.03 mm |
| Test Station Capacity | 6-position fixture |
| Specimen Geometry | Ø12 mm circular disc or 12 mm × 12 mm square |
| Brand | Easysensor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DF-H-05 |
| Price | USD 165 (FOB) |
| Target Analytes | Fe, Cd, Co, Cu, Mn, Zn, Pb, Ni, P, As, Cr, Mo, Sb, Se, V, W |
| Binding Layer | ZrO₂–Chelex composite gel, thickness 0.40 mm, dimensions 150 × 20 mm |
| Filter Membrane | PVDF, 0.10 mm thick, 150 × 20 mm |
| Diffusive Gel | Agarose-based, nominal thickness 0.80 mm |
| Sampling Area | 3000 mm² (150 × 20 mm) |
| Packaging | Individually sealed in sterile, light-blocking aluminum foil pouches under moist conditions |
| Shelf Life | 12 months at room temperature, protected from light and desiccation |
| Brand | ELASTOCON |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ES 14 |
| Quotation | Upon Request |
| Temperature Range | 100–900 °C |
| Temperature Stability | ±10 °C |
| Thermocouple Types | Type N (controller), Type K (max temp sensor) |
| Tube Material | Fused quartz (quartz glass) |
| Heating Zone Dimensions | Ø25 × 200 mm |
| Overall Dimensions (W×D×H) | 350 × 275 × 355 mm |
| Net Weight | 22 kg |
| Voltage | 220–240 V, 1-phase, 50 Hz |
| Power Consumption | 500 W |
| Gas Flow Rate | 0.1–2 L/min |
| Included Accessories | Digital temperature controller, overtemperature safety limiter, drying tube, flowmeter, wash bottle, five fused quartz crucibles |
| Compliance | Designed for ISO 247, ISO 1408, ASTM D297, ASTM D1603 |
| Brand | Zhongjiaojinyuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ICA-3000 |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | WAHS-20A Plus |
| Sample Positions | 20 |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (customizable: 0.5/2/5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50/100 mL) |
| Simultaneous Heating | 1 or 2 vials |
| RSD | <1.0% (100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB |
| Compliance | ASTM D6866, ISO 17025-compatible operation, GLP/GMP-ready audit trail via software logging |