Other General Analytical Instruments
Filter
Showing 181–210 of 382 results
| Brand | Insent |
|---|---|
| Origin | Japan |
| Model | TS-5000Z |
| Type | Taste Sensing System |
| Sensor Principle | Artificial Lipid Membrane Array |
| Output Metrics | Relative Taste Intensity (Bitterness, Sourness, Saltiness, Sweetness, Umami, Astringency), Aftertaste Duration (Bitter/Umami/Astringent), Richness Index |
| Data Output | Multidimensional Taste Profile Vectors, PCA Loadings, Radar Charts, 3D Spherical Plots, Contour Maps, Time-Resolved Taste Kinetics |
| Compliance | Designed for GLP-compliant sensory QA/QC workflows |
| Software | TS-5000Z Analysis Suite v4.2 with Audit Trail & User Access Control (21 CFR Part 11 Ready) |
| Brand | INSENT (Japan) |
|---|---|
| Origin | Japan |
| Type | Electronic Tongue / Taste Sensory Analyzer |
| Model | TS-5000Z |
| Sensor Technology | Artificial Lipid Membrane Sensors |
| Measurement Parameters | Sourness, Sweetness, Bitterness, Saltiness, Umami, Astringency, and Aftertastes (Bitter, Astringent, Umami Richness) |
| Compliance | Designed for GLP/GMP-aligned sensory laboratories |
| Software | TS-5000Z Analysis Suite with Audit Trail & Data Export (CSV, PDF, PNG) |
| Interface | Touchscreen GUI with Wizard-Based Operation |
| Data Management | Integrated Server-Side Storage with User Access Control |
| Brand | INSENT |
|---|---|
| Origin | Japan |
| Model | TS-5000Z |
| Product Type | Electronic Tongue / Taste Sensing System |
| Compliance | Designed for GLP-compliant sensory evaluation environments |
| Sensor Technology | Artificial lipid-membrane sensor array mimicking human taste receptor response |
| Brand | INSENT |
|---|---|
| Origin | Japan |
| Model | TS-6000A |
| Type | Electronic Tongue Taste Analysis System |
| Sensor Principle | Artificial Lipid Membrane Sensor Technology |
| Data Architecture | Integrated Onboard Data Management Server |
| Interface | Touchscreen GUI + Keyboard/Display Support + Ethernet Remote Access |
| Compliance Context | Designed for GLP-compliant sensory evaluation workflows |
| Software | INSENT TAS v5.x with Multivariate Statistical Modules (PCA, DFA, ANOVA, Cluster Analysis) |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | Multi-Port Sampling Device |
| Valve Configurations | 2-way and 3-way |
| Port Options | 12-, 16-, 18-, or custom-configurable inlet ports |
| Material Options | PTFE- or PEEK-coated valve bodies |
| Application | Automated, sequential vapor/sampling stream selection for real-time analytical systems |
| Compliance | Designed for integration with PTR-MS, SIFT-MS, and other trace gas analyzers |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | Nasal Sampling Probe |
| Compatibility | PTR-MS systems |
| Heated | Yes |
| Response Time | < 100 ms |
| Application | Real-time human nasal inhalation monitoring for VOC and odorant analysis |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AMI 400TPx |
| Pricing | Upon Request |
| Core Functionality | Fully Automated TPD, TPR, TPO, TPSR, Pulse Chemisorption, Single-Point BET, Optional MS/GC/FID/FTIR Coupling |
| Gas Compatibility | Inert, Reducing (H₂), Oxidizing (O₂, NO, CO₂), Corrosive (SO₂, H₂S) |
| Control Architecture | Integrated Pneumatic Valve Manifold with Real-Time Flow Path Visualization |
| Software | Proprietary ChemiSoft™ with Live System Status Dashboard, Parameter Logging, and Audit-Trail-Ready Data Export |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A1 / 2DMax1100P1 |
| Flow Rate Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 0–4000 psi with overpressure protection |
| UV-Vis Detection Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P1 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A2 / 2DMax1100P2 |
| Flow Range | 0–200 mL/min (customizable up to higher rates) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-VIS Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P2 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A3 / 2DMax1100P3 |
| Price | Upon Request |
| Pump Flow Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-Vis Detector Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P3 only) | 160-tube rack, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A1 / 2DMax1500P1 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Sealing Force | Up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.3 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi (A1) / 0–4,000 psi (P1) |
| UV-VIS Detection | Four simultaneous wavelengths, 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200-line grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitation Loop | 20 µL (A1) / 2 mL (P1) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A2 / 2DMax1500P2 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Seal Force | up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.5 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi |
| UV-VIS Detection Wavelength Range | 190–900 nm (quad-wavelength simultaneous detection) |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200 lines/mm grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitative Loop | 20 µL (customizable) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition Range | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Gas Supply | Nitrogen or compressed air |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RHC020 |
| Pricing | Upon Request |
| Probe Options | 2 mm & 50 µm |
| Work Function Resolution | 1–3 meV (2 mm probe), 5–10 meV (50 µm probe, on optical vibration isolation table) |
| Max Scan Area | 50 mm × 50 mm |
| Positioning Resolution | 318 nm |
| Z-Axis Tracking | Auto-gap control with manual coarse adjustment (25.4 mm KP translation stage) |
| Zero-Crossing Signal Detection | Integrated parasitic capacitance suppression |
| Sample Heater | 50 mm × 50 mm, up to 100 °C |
| RH Control Range | 10–100 % RH, ±1 % accuracy (optional) |
| Temperature Control | Closed-loop PID |
| Probe Mount | Direct-insert holder compatible with 2 mm to 50 µm probes |
| Optional Modules | SPV020 Surface Photovoltage, SPS030 Spectral Photovoltage |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | UHV-KP020 |
| Price | Upon Request |
| Work Function Resolution | 1–3 meV (with 2–10 mm probe) |
| Probe Diameter Customizable | 2–10 mm |
| Probe Length Customizable | Flange-to-sample distance |
| Vacuum Port | DN40 (2.75″ CF), other sizes optional |
| Manual Translation Stage | 50 mm (100 mm optional) |
| Base Pressure | ≤2×10⁻¹¹ mbar |
| Distance Control | Active electro-mechanical tracking system |
| Capacitance Nulling | Zero-crossing signal detection circuitry |
| Optional Accessories | Motorized translation stage, UHVSKP upgrade kit, Surface Photovoltage modules SPV020 & SPS030 |
| Brand | KPM AMS |
|---|---|
| Origin | USA |
| Model | SmartChem 140 |
| Product Type | Discrete Chemistry Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥50 positions |
| Reagent Positions | ≥20 |
| Cuvette Path Length | 6 mm |
| Light Source | Tungsten-halogen lamp (6 V / 10 W, 2000 h lifetime) |
| Absorbance Range | 0–3.5 OD |
| Resolution | 0.0001 Abs |
| Optical System | Dual-beam with 9-position filter wheel + blind position |
| Detection | Silicon photodiode |
| Analysis Speed | Up to 140 samples/hour |
| Sample Volume | 3–450 µL |
| Reagent Consumption per Test | ~300 µL |
| Sample Tube Dimensions | 16 mm × 100 mm (diameter × height) |
| Automatic Dilution | Yes |
| Standard Preparation | Automated serial dilution from single stock standard |
| Blank Correction | True sample blank subtraction |
| Calibration | Up to 6th-order polynomial regression |
| Data Output | Raw absorbance-time profiles with reprocessing capability |
| Compliance | ISO, AOAC, APHA, USEPA, AFNOR, COFRAC, BATF methods |
| Brand | KPM AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SmartChem 450 |
| Sample Capacity | 100 positions |
| Reagent Positions | 72 |
| Optical Path Length | 10 mm |
| Wavelength Range | 340–1100 nm |
| Light Source | Tungsten-Halogen and Deuterium (Dual) Photometric Source |
| Detection Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 200 µL |
| Throughput | Up to 450 samples/hour |
| Filtration | 9-position motorized filter wheel |
| Compliance | ISO/IEC 17025, US EPA Methods (e.g., 353.2, 365.4), AOAC, OIV, AFNOR, COFRAC, BATF |
| Brand | KPM-AMS |
|---|---|
| Origin | USA |
| Model | Futura II |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340 nm – 1100 nm |
| Sample Capacity | 240 positions |
| Reagent Positions | 20 |
| Flow Cell Path Length | 10 mm – 5 m |
| Light Source | Photometric Lamp |
| Brand | KPM-AMS |
|---|---|
| Origin | USA |
| Model | Futura III |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–110 nm |
| Sample Capacity | ≥240 positions |
| Reagent Positions | 20 |
| Flow Cell Path Length | 10 mm to 5 m |
| Light Source | Photometric light source |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ERT-01 |
| Pricing | Available Upon Request |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | YH-1 |
| Measurement Range | ±6 mm |
| Resolution | 0.01 mm |
| Accuracy | ±0.015 mm |
| Contact Probe Diameter | Φ10 mm |
| Display Type | Analog Pointer Dial |
| Brand | LeiCi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PXBJ-286F |
| Price | USD 650 (FOB) |
| Sample Introduction Modes | Direct Sampling, Dynamic Headspace Sampling, Field Sampling |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model Series | PXSJ-227L, PXSJ-226T, PXSJ-216F, PXSJ-270F |
| Sample Introduction | Direct immersion |
| Category | Ion Meters (Potentiometric Ion-Selective Electrode Analyzers) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MKG-J2H |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Continuous Flow Analyzer |
| Wavelength Range | Not applicable (microwave frequency domain, 2.45 GHz) |
| Sample Capacity | 1 stream |
| Reagent Ports | 1 |
| Flow Cell Optical Path Length | 300 mm |
| Radiation Source | 2.45 GHz Magnetron-Based Microwave Generator |
| Microwave Power Output | 0–1600 W, continuously adjustable |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 600 × 400 × 1200 mm |
| Cavity Dimensions (W×D×H) | 450 × 400 × 550 mm |
| Tubing Material | High-purity alumina ceramic or PEEK-lined engineering polymer |
| Internal Tubing Diameter | 60 mm |
| Temperature Monitoring | Integrated Pt100 RTD sensor with closed-loop feedback |
| Control System | Industrial PLC with 7-inch HMI touchscreen interface |
| Safety Compliance | Meets GB 10436-2008 (Chinese national standard for microwave leakage ≤ 5 mW/cm² at 5 cm) |
| Brand | Masa |
|---|---|
| Origin | Slovakia |
| Model | MCCGC-AIMS |
| Sample Introduction | Automated |
| Sensitivity | ppb to ppt |
| Library | VOCs, Explosives |
| Operating Pressure | 600–1200 mbar |
| Drift Gas Flow | 500–1200 mL/min |
| Sample Gas Flow | 2–500 mL/min |
| Drift Field Strength | 200–560 V/cm |
| Polarity | Positive/Negative |
| Ionization Source | Corona Discharge (Non-radioactive) |
| Pre-separation GC | Multi-Capillary Column Gas Chromatograph |
| IMS Temperature Range | 30–140 °C |
| Resolution (FWHM) | 90–100 (N₂/air) |
| Power Supply | 250 V / 24 V |
| Communication | TCP/IP, USB 2.0 |
| Dimensions (mm) | 490 × 390 × 150 |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 916 Ti-Touch |
| Electrode Interfaces | 2 working electrode ports |
| Dosing Channels | 2 independent dosing units |
| Connectivity | Built-in Ethernet & LIMS interface (no PC required) |
| Report Output | Auto-generated PDF reports saved to USB drive |
| Sample Handling | Optional automated sample processor with interchangeable rotor trays (e.g., 12-, 24-, or 48-position) |
| Stirring Control | Adaptive speed adjustment based on sample viscosity |
| Dosing Technology | Dosino TMDosino™ multi-dose module — reagent cartridge replacement without disassembly or operator contact |
| Regulatory Compliance | Full GLP/GMP traceability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowIR™ |
| Product Type | Continuous Flow Analyzer |
| Spectral Range | 4000–650 cm⁻¹ |
| Detector | DTGS |
| Pressure Range | Ambient to 7 bar (standard), up to 30 bar (high-pressure option) |
| Temperature Range | Ambient to 120 °C |
| Internal Cell Volume | 10 µL or 50 µL |
| Integrated Temperature Sensor | Yes |
| Dimensions (W×D×H) | 137 × 241 × 116 mm |
| Weight | 2.6 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DS Micro Flow Cell |
| Pricing | Upon Request |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 3Flex |
| Gas Adsorption Capability | Physisorption & Chemisorption (optional) |
| Tri-Station Operation | Independent simultaneous analysis |
| Pressure Range | Down to 1×10⁻⁹ P/P₀ |
| Detection Limit | Ultra-micropore resolution (≤ 0.7 nm) |
| Vapor Compatibility | Integrated thermostatted manifold (45 °C ±0.05 °C), optional heated vapor dosing |
| Software | MicroActive™ with customizable reporting, ASTM/ISO-compliant data processing |
| Sample Preparation | In-situ tube heater for degassing under vacuum or inert gas |
| Sealing System | Metal-sealed, hard-stop valves with corrosion-resistant manifold |
| P₀ Measurement | Dedicated P₀ sensor with continuous saturation pressure monitoring |
| Fluid Library | >80 pre-loaded adsorbates (N₂, Ar, CO₂, H₂, Kr, H₂O, alcohols, hydrocarbons, etc.) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 |
| Temperature Range | –110 °C to 1100 °C |
| Detection Method | High-Stability TCD (Thermal Conductivity Detector) |
| Gas Inlets | 12 |
| Automated Valves | 4 × 6-port valves |
| Mass Flow Controllers | 4 (sample prep, dual carrier/reference, analysis) |
| Sample Tube | FlowThru™ quartz, rated to 1100 °C |
| TCD Zone Temperature | 150–250 °C |
| Optional Accessories | Online MS/FTIR/GC interface, vapor generator, cryogenic bath (–110 °C) |
| Software | Windows-based AutoChem software with GRAMS/32 peak processing module |
| Analytical Modes | TPD, TPR, TPO, TPRx, pulse chemisorption, isothermal reaction, BET surface area |
| Brand | Microphotons |
|---|---|
| Origin | Imported |
| Manufacturer Type | OEM Manufacturer |
| Model | C3A-2700LAE |
| Pricing | Upon Request |