| Brand | Keopsys |
|---|---|
| Origin | France |
| Model | PEFA-SP-C Series |
| Wavelength Range | 1535–1565 nm |
| Saturation Output Power | up to +33 dBm |
| Pulse Width | 0.3–10 ps |
| Peak Power | up to 1 kW |
| Repetition Rate | 10 MHz – 100 GHz |
| Compliance | CE, RoHS |
| Brand | TechnoTeam |
|---|---|
| Origin | Germany |
| Model | KMP |
| Application Scope | Automotive Headlamp & General Lighting Photometry |
| Optical Principle | Fourier-Transform-Based Imaging Goniophotometry |
| Effective Test Distance | As low as 40 cm (vs. conventional 10 m) |
| Chamber Dimensions | 95 cm × 50 cm × 43 cm |
| Compliance | ECE R112, ECE R149, UN Regulation No. 112 & 149, SAE J1383, AK31, B50L, HV Standards |
| Measurement Capabilities | Luminous Intensity Distribution, Illuminance Distribution, Chromaticity Coordinates (CIE 1931), Color Rendering Index (CRI), Color Shift Analysis (e.g., Cut-off Line Definition), Spatial Luminance Mapping |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CL-200A |
| Luminance Accuracy Class | JIS C 1609-1:2006 AA Grade |
| Illuminance Spectral Match Error (f₁') | <6% |
| Cosine Correction Error (f₂) | <3% |
| Illuminance Range | 0.1–99,990 lx |
| Luminance Range | 0.01–9,999 fcd |
| Chromaticity Accuracy (xy) | ±0.002 at 800 lx (Standard Illuminant A) |
| Repeatability (xy) | ±0.0005 (2σ) |
| Response Time | 0.5 s (continuous measurement) |
| Operating Temp. | −10–40°C, RH ≤85% (non-condensing) |
| Battery Life | >72 h (alkaline, continuous use) |
| Dimensions | 69 × 174 × 35 mm |
| Weight | 215 g (without batteries) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LS-100 / LS-110 |
| Pricing | Available Upon Request |
| Measurement Angle | 1° (LS-100) / 0.33° (LS-110) |
| Optical System | 85 mm f/2.8 SLR Lens with Stray Light Suppression <1.5% |
| Minimum Measurable Area | Φ14.4 mm (LS-100) / Φ4.8 mm (LS-110) |
| Spectral Response Compliance | Within ±8% f₁′ error vs. CIE Photopic Luminosity Function (V(λ)) |
| Sensor | Silicon Photodiode |
| Luminance Units | cd/m² or foot-lambert (fL), selectable |
| Measurement Range (FAST) | 0.001–299,900 cd/m² (LS-100) / 0.01–999,900 cd/m² (LS-110) |
| Measurement Range (SLOW) | 0.001–49,990 cd/m² (LS-100) / 0.01–499,900 cd/m² (LS-110) |
| Accuracy | ±2% ± digit (A-source, 20–30°C) |
| Repeatability | ±0.2% ± digit (A-source) |
| Operating Temp. | 0–40°C, RH ≤85% (non-condensing) |
| Power | 9 V alkaline battery (typ. 16 mA during measurement) |
| Dimensions | 79 × 208 × 150 mm |
| Weight | 850 g (excl. battery) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | LS-150 / LS-160 |
| Luminance Range | 0.001–999,900 cd/m² (LS-150), 0.01–9,999,000 cd/m² (LS-160) |
| Measurement Angle | 1° (LS-150), 1/3° (LS-160) |
| Optical System | Single-Lens Reflex (SLR), f=85 mm, F2.8 |
| Spectral Response | Matched to CIE V(λ) Photopic Luminosity Function |
| Accuracy | ±2% ±2 digits (≤1 cd/m²), ±2% ±1 digit (>1 cd/m²) |
| Repeatability | 0.2% + 1 digit |
| Minimum Measured Area | Ø14.4 mm (1°), Ø4.5 mm (1/3°) |
| with optional macro lens | Ø1.3 mm (LS-150), Ø0.4 mm (LS-160) |
| Shortest Measurement Distance | 1012 mm (1°), 213 mm (1/3°) |
| Stray Light Suppression | ≤1% |
| Polarization Error | ≤1% |
| Temperature Drift | ≤0.2%/K |
| Compliance | DIN 5032-7 Class B (LS-150) |
| Interface | USB 2.0 |
| Power | USB bus power or AC adapter (optional) |
| Dimensions | 71 × 214 × 154 mm |
| Weight | 850 g (body only) |
| Brand | Other brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Pricing | Upon Request |
| Current Ratings | AUX-35: 3.07 A |
| AUX-50 | 4.17 A |
| AUX-100 | 8.33 A |
| Operating Voltage | 12–13.3 V DC |
| Color Temperature | 3000 K |
| Rated Lifetime | 600–2000 hrs |
| Mounting | 1-inch flange interface |
| Software Compatibility | LightMtrx® |
| Power Supply Requirement | Labsphere adjustable DC power supply |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COLOSUS System |
| Price Range | USD $65,000 – $105,000 |
| Spectral Range | 0.3–14 µm |
| Calibration Traceability | NIST-traceable radiance/irradiance |
| Dynamic Range | >1×10¹⁰ |
| Uniformity | >98% (spatial) |
| Blackbody Temperature Range | −40 °C to +175 °C |
| Blackbody Emissivity | >0.998 |
| Temperature Stability | ±0.01 °C |
| Aperture Size | 4 in (102 mm) |
| Software Platform | IRWindows™ 4 |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | CSS |
| Price Range | USD 7,000 – 14,000 |
| Beam Divergence | <3° |
| Working Distance | 3 m |
| Illuminated Area Diameter at 3 m | 20 cm |
| Irradiance Uniformity | ≥98% |
| Spectral Range | 350–2400 nm |
| Correlated Color Temperature | 5250 K |
| Typical Irradiance at 3 m | 10,000 lux (≈1 Sun, AM1.5G equivalent) |
| Control Interface | PC-based software with real-time intensity adjustment |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | CSTM-CM-PD |
| Price Range | USD 1,400 – 140,000 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | CSTM-RTC |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports (sample & 9° specular-reflected beam), 0.5-inch top detector port, bottom detector port (RTC), integrated central sample mount |
| Geometry | 9°/h reflectance, variable-angle incidence capability (RTC), specular trap included |
| Internal Baffle Design | Low-profile, minimized obstruction to maximize wall visibility |
| Aperture Edge | Knife-edge for wide-angle scatter collection |
| Compliance | ASTM E1331, ISO 13468, ISO 13469, USP <857>, compatible with GLP/GMP data integrity workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CSTM-VCSEL-PW-060-LIVT |
| Pricing | Available Upon Request |
| Integrating Sphere Material | Spectralon® / Spectraflect® / Permaflect® |
| Sphere Diameter | 6 in (customizable) |
| Input Port Diameter | 1.5 in (customizable) |
| Spectrometer Wavelength Range | 800–980 nm |
| Spectral Resolution (FWHM) | 0.1–0.16 nm |
| Wavelength Accuracy | ±0.1 nm |
| Maximum Sampling Rate | 200 kHz |
| Optical Power Range (Spectralon®, 940 nm) | 1 mW – 200 W |
| High-Speed Detector Linearity | ±0.5% |
| Detector Measurement Accuracy | ±1% |
| Detector Effective Digits | 5 |
| VCSEL Temperature Control Range | 1–85 °C |
| Temperature Stability | ±0.1 °C |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FS2 |
| Pricing | Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GPS |
| Pricing | Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HELIOS |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Illumia |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Illumia Pro |
| Sphere Diameter Options | 0.5 m, 1.0 m, 1.65 m, 2.0 m |
| Measurement Geometry | 2π and 4π compatible |
| Compliance | IESNA LM-79, IESNA LM-80 |
| Core Components | High-resolution CCD spectrometer, precision programmable current source, thermoelectric cooler (TEC) temperature controller with real-time junction temperature monitoring, auxiliary calibration lamp, Illumia Pro measurement software |
| Data Management | Automated acquisition, traceable metadata logging, export to CSV, XML, and industry-standard report formats |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Illumia Pro3 |
| Sphere Diameter | 50 cm |
| Spectral Range (Calibrated) | 350–1000 nm |
| Wavelength Accuracy | ±0.3 nm |
| Integration Time | 40 µs – 5 s |
| Measurement Geometry | 2π |
| Coating | Spectralect® White Diffuse Reflectance Coating |
| Software | Integral™ v5.x (with Temperature, Current & Voltage Control, Real-Time LIVT Synchronization, and GLP-Compliant Data Logging) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia® Plus 2 |
| Spectrometer Options | CDS600 (200–850 nm), CDS610 (350–1000 nm), CDS2600 (325–1050 nm), CDS3020 (350–830 nm), CDS3030 (350–1100 nm) |
| Integrating Sphere Diameters | 25 cm – 195 cm |
| Coating Reflectance | 97–98% @ visible range |
| Shutter | Optional (CDS2600/CDS3020/CDS3030) |
| Compliance | IES LM-79-19, LM-78, LM-82, CIE S 025/E:2015 |
| Auto-Stability Detection | Yes |
| Report Format | Customizable Excel export with multilingual UI support |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia® Pro3-UV |
| Integrating Sphere Diameter | 15 cm |
| Spectral Range (Calibrated) | 200–400 nm |
| Wavelength Accuracy | ±0.4 nm |
| Integration Time | 8 ms – 900 s |
| Spectrometer | CDS-2600-UV |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia®Plus2-2600 |
| Integrating Sphere Diameter | 165 cm or 195 cm |
| Spectral Range | 325–1050 nm |
| Temperature Control Range | 15–80°C |
| Typical Ramp Rate (20→80°C) | 52 min |
| Detector | TE-cooled, back-illuminated CCD array |
| Exposure Time | 8 ms – 900 s |
| Compliance | IES LM-79-19, LM-82-12, LM-78-15, ISO/CIE S 025:2015 |
| Software | Integral® v5.x with automated stability assessment and CFR 21 Part 11-ready audit trail |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ILT2400 UVG |
| Pricing | Available Upon Request |
| Spectral Range | 240–310 nm |
| Irradiance Range | 10 nW/cm² to 500 µW/cm² |
| Radiant Exposure (Dose) Range | 10 nJ/cm² to >1 MJ/cm² |
| Calibration | NIST-Traceable, ISO/IEC 17025:2017 Accredited |
| Detector Type | UVGI-Optimized SED240/WBS320/W Filtered Photodiode |
| Display | 4.3″ VGA Capacitive Touchscreen |
| Current Measurement Range | 50 pA – 1 mA |
| Dynamic Range | 8 decades |
| Bias Voltage | 5 V Reverse Bias |
| Internal Storage | 4 GB |
| Operating Temperature | 0–40 °C |
| Interfaces | USB Micro (data download), USB Mini (charging & remote logging via DataLight III) |
| Dimensions | 1.6″ H × 3.0″ W × 6.0″ L |
| Weight | 0.95 kg |
| Enclosure | Rugged Portable Carry Case |
| Compliance | CE (EMC Class B, no RF emissions interference) |
| Software | DataLight III (macOS & Windows compatible) |
| Sensor Connector | 15-pin D-sub |
| Application Scope | Non-pulsed UV-C sources only — low-pressure & medium-pressure mercury lamps, UVC LEDs, excimer lamps |
| Brand | LabSphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LF Human Eye Safety Testing Solution |
| Pricing | Available Upon Request |
| Spectralon Transmittance | 25% or 50% |
| Spectralon Target Size | 30 cm × 50 cm (customizable) |
| Spectralon Spectral Flatness | ±1.5% |
| Wavelength Range | 400–1000 nm |
| DUT-to-Target Distance | 5–30 cm |
| Maximum DUT Divergence Angle | 80° (customizable up to 120°) |
| Eye Safety Aperture | 7 mm |
| Measurement Modes | Total Radiant Power, Per-Spot Radiant Power, Spatial Distribution, Angular Emission Profile, MPE (Maximum Permissible Exposure) Compliance Assessment |
| Data Output Formats | .txt, .csv |
| Software Features | Pixel-level spot detection & centroid localization, intensity calibration with NIST-traceable reference, real-time MPE calculation per IEC 62471 and ANSI Z136.1 |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LFC |
| Pricing | Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LFC-150 |
| Integrating Sphere Diameter | 1.5 m |
| Spectral Range | 250–850 nm or 350–1000 nm (configurable) |
| Calibration Traceability | NIST-traceable |
| Compliance | LM-79, CIE 127:2007, GB/T 7922, GB/T 5702, IESNA standards |
| Measurement Modes | 2π and 4π |
| Reflectance of Sphere Coating | ≥96% (Spectralon®-equivalent 680 coating) |
| Software | LFC Control & Analysis Suite (supports ASTM E308, CIE 15:2018, CIE 13.3, and USP <1058> data handling protocols) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LMS-3M |
| Diameter | 3 m |
| Compliance | IESNA LM-79, LM-80, ENERGY STAR® Thermal Test Requirements |
| Internal Coating | Spectraflect® (≥98% diffuse reflectance, 400–700 nm) |
| Measurement Geometry | Configurable 4π or 2π via optional baffle & port reducer |
| Detector Compatibility | Multiple photometric and spectroradiometric sensors simultaneously |
| Mounting Flexibility | Upward, downward, or axial lamp orientation |
| Temperature Control | Integrated thermal monitoring module with inlet/outlet baffles |
| Structural Assembly | Field-installed modular design (wedge segments, base frame, fasteners) |
| Dimensions (packed) | ~3.3 × 2.3 × 1.6 m per crate |
| Required Site Conditions | Level floor, structural load capacity ≥500 kg/m² |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS System |
| Spectral Range | 350–1700 nm (Si & InGaAs detectors) |
| Integrating Sphere Diameters | 2", 4", 6" |
| Coating Options | Spectraflect®, Spectralon®, Infragold® |
| Detector Options | Silicon (Si), Indium Gallium Arsenide (InGaAs) |
| Power Range | ~1 nW to >100 W (configuration-dependent) |
| Input Port Angle | 45° off-axis |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PFT |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PERMAFLECT® |
| Price Range | USD $0–$7,200 (est.) |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | QES-1000 |
| Price Range | USD 14,000 – 28,000 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT-060-SF, RT-060-IG, RTC-060-SF, RTC-060-IG |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports (RT) |
| Detector Port | 0.5-inch (top-mounted for RT, bottom-mounted for RTC) |
| Mirror Trap | Integrated specular beam trap |
| Sample Mounting | Adjustable center-stage (RTC), dual 1-inch sample holders (RT), optional jaw-type / clamp-type / slot-type fixtures |