| Key | Brand: Rigaku |
|---|---|
| Origin | USA |
| Model | NEX QC |
| Detection Principle | Energy-Dispersive X-Ray Fluorescence (EDXRF) |
| Analyte | Total Sulfur |
| Detection Limit | 5 ppm |
| Measurement Range | 0–10 wt% |
| Sample Volume | 5 mL |
| Analysis Time | 1–999 s (default 300 s) |
| Calibration Method | Compton Scattering C/H Ratio Correction |
| Data Output | USB + Ethernet |
| Environmental Requirements | RH < 85% (no condensation), vibration-free, non-corrosive atmosphere |
| Compliance Standards | ASTM D4294, GB/T 17040 |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200 Cl |
| X-ray Tube | Pd anode, 50 kV / 4 mA, 200 W |
| Detection Limits | Cl: 0.1 ppm, S: 0.1 ppm, Si: 0.5 ppm, Pb: 0.2 ppm |
| Analytical Standards | ASTM D7536 (Cl), SH/T 0842 (S), SH/T 0977 (Cl), SH/T 0993 (Si), ASTM D5059 (Pb) |
| Sample Types | Liquid hydrocarbons (gasoline, diesel, naphtha, jet fuel, crude oil, residuum), aqueous matrices (including wastewater), solid catalysts, polypropylene |
| Optical System | Multi-crystal automatic switching spectrometer |
| Automation | Integrated 12-position autosampler |
| Software | Full-featured Windows-based platform with qualitative/quantitative analysis, standardless semi-quantitative mode, spectral calibration, thin-film correction, and reference database matching |
| Brand | Rigaku |
|---|---|
| Origin | USA |
| Model | NEX QC+ |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Detection Limit | 2.3 ppm for S |
| Measurement Range | 0–10 wt% S |
| Accuracy (Relative Error) | ±0.0001 |
| Analysis Time | < 3 min (configurable from 1–999 s) |
| Sample Volume | < 5 mL |
| Elemental Range | Na (11) to U (92) |
| Compliance | ASTM D4294, GB/T 17040 |
| Portability | Handheld / Field-Deployable |
| Environmental Operating Range | 15–35 °C, RH < 85% (non-condensing) |
| Data Interface | USB + Ethernet |
| Matrix Correction | Compton Scattering C/H Ratio Normalization |
| Filtration | Multi-layer Composite Primary Beam Filters |
| Safety | Zero hazardous waste generation (no gas, liquid or solid effluent) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| X-ray Tube Power | 200 W |
| Target Material | Pd |
| Detector Types | Flow-proportional Counter (F-PC) and Scintillation Counter (SC) |
| Analytical Elements | Na (11) to U (92) |
| Configuration | Multi-channel WDXRF |
| Brand | Choice Analytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Color Choice hz |
| Price | USD 68,500 (FOB US Port) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Micro-Z ULS |
| Detection Principle | Wavelength Dispersive X-ray Fluorescence (WDXRF) |
| Detection Limit | 0.2 ppm |
| Measurement Range | 0–5 wt% |
| Analysis Time | < 300 s |
| Excitation Source Power | 80 W |
| Vacuum Requirement | Yes (gas-free operation) |
| Power Supply | AC 200–240 V, 200 W |
| Operating Environment | 10–40 °C, RH < 80 % |
| Dimensions (W×D×H) | 45 × 41 × 43 cm |
| Weight | 40 kg |
| Compliance Standards | ASTM D2622, GB/T 11140, SH/T 0842 |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Micro-Z Cl |
| Instrument Type | Benchtop |
| Excitation Mode | Single-Wavelength |
| Analyte | Total Chlorine |
| X-ray Tube Power | 80 W |
| Detection Limit | 0.11 ppm |
| Quantification Range | 0–5 wt% |
| Analysis Time | 300 s |
| Vacuum Requirement | Yes (gas-free operation) |
| Compliance | SH/T 0977, ASTM D7536 |
| Operating Environment | 10–40 °C, <80% RH |
| Dimensions (W×D×H) | 45 × 41 × 43 cm |
| Weight | 40 kg |
| Power Supply | AC 200–240 V |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200 S |
| Instrument Type | Benchtop WDXRF Spectrometer |
| Excitation | Monochromatic Pd-target X-ray Tube (50 kV, 4 mA, 200 W) |
| Analyte Elements | Total S (ASTM D7039), Total Cl (ASTM D5059), Total Si (SH/T 0993), Total Pb (ASTM D5059) |
| Detection Limits | S: 0.1 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, Pb: 0.2 ppm |
| Quantification Range | 0–99.99 wt% |
| Detector Linear Range | kcps |
| Beryllium Window Thickness | µm |
| Sample Forms | Liquids (gasoline, diesel, naphtha, jet fuel, crude oil, residuum, aqueous samples), Solids (catalysts, polypropylene), Powders |
| Compliance Standards | ASTM D7039, ASTM D5059, SH/T 0842, SH/T 0977, SH/T 0993 |
| Automation | Integrated 12-position autosampler |
| Optical System | Multi-crystal automatic switching optics with monochromatic excitation |
| Brand | Choice Analytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Clarity Choice |
| Price | USD 62,500 (approx. based on ¥450,000 at 1 USD = ¥7.2) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200 |
| Instrument Type | Benchtop WDXRF Spectrometer |
| Excitation Source | Pd-anode X-ray tube (50 kV / 4 mA, 200 W) |
| Analyzed Elements | Total S, Total Cl, Total Si, Total Pb |
| Detection Limits | S: 0.15 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, Pb: 0.2 ppm |
| Quantification Range | 0–99.99% |
| Optical Configuration | Single-wavelength excitation with automated multi-crystal changer (RX4, RX9, and others) |
| Sample Handling | 12-position automatic sample changer |
| Compliance Standards | GB/T 111140 (S), SH/T 6083 (Cl & Si), ASTM D5059 (Pb) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200+ |
| X-ray Tube | Pd anode, 50 kV / 4 mA, 200 W |
| Detection Limits | S: 0.1 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, As: 0.2 ppm |
| Detection Range | 0–99.99% |
| Standard Compliance | SH/T 0842 (S), SH/T 0977 (Cl), SH/T 0993 (Si) |
| Optical System | Automated multi-crystal spectrometer with high-resolution crystal selection |
| Sample Handling | 12-position automatic sampler |
| Sample Types | Liquids (gasoline, diesel, naphtha, jet fuel, crude oil, residuum, water, wastewater), solids (catalysts, polypropylene, powders) |
| Brand | Choice Analytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Clarity Chorice hz |
| Price | USD 58,000 (FOB US Port) |
| Brand | Rigaku |
|---|---|
| Origin | USA |
| Model | NEX CG II |
| Element Range | Na (11) to U (92) |
| Detection Limits (typical for petroleum) | Si 1.1 ppm, P 0.8 ppm, S 0.5 ppm, Cl 0.4 ppm, Mn 0.9 ppm, Fe 0.7 ppm, Pb 0.7 ppm |
| Concentration Range | 0.11 ppm – 10% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | 0.05% RSD |
| Detector | Silicon Drift Detector (SDD) with Peltier cooling |
| Excitation Source | Pd anode X-ray tube, max 50 kV / 50 W |
| Polarization Optics | 5-position polarized secondary target assembly |
| Geometry | Cartesian 3D configuration (X-ray tube → polarizer → sample → detector) |
| Sample Volume | 5 mL |
| Autosampler | 15-position carousel |
| Calibration Method | Compton scattering C/H ratio correction |
| Data Output | USB 2.0 and Ethernet (RJ-45), CSV/PDF export |
| Dimensions | 463 × 492 × 382 mm (W×D×H) |
| Power | AC 200–240 V, 50/60 Hz, 1.6 A |
| Operating Environment | 18–28 °C, RH <75% non-condensing, vibration-free, non-corrosive atmosphere |
| Brand | Rigaku |
|---|---|
| Origin | USA |
| Model | NEX DE |
| Detection Range | Na to U |
| Sample Volume | 5 mL |
| Analysis Time | 30–900 s (standard: 300 s) |
| Compliance | ASTM D4294, ASTM D8252, ASTM D6481, GB/T 17040 |
| Excitation Filtration | Multi-layer composite filters |
| Operating Temperature | 10–35 °C |
| Relative Humidity | <80% RH (non-condensing) |
| Data Output | USB + Ethernet |
| Software | QuantEZ |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| X-ray Tube Power | 200 W |
| Elemental Range | Na (11) to U (92) |
| Detector | Flow Proportional Counter (F-PC) and Scintillation Counter |
| Sample Handling | 12-position Automatic Sampler |
| Operating Atmosphere | Air, He, or Vacuum |
| Dimensions | 580(W) × 670(H) × 680(D) mm |
| Power Supply | 200–240 V, 10 A |
| Grounding Resistance | <30 Ω |
| Ambient Temperature | 10–40 °C |
| Relative Humidity | <80% RH |