Empowering Scientific Discovery

PHASE Company Beijing Representative Office

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Rigaku
OriginUSA
ModelNEX QC
Detection PrincipleEnergy-Dispersive X-Ray Fluorescence (EDXRF)
AnalyteTotal Sulfur
Detection Limit5 ppm
Measurement Range0–10 wt%
Sample Volume5 mL
Analysis Time1–999 s (default 300 s)
Calibration MethodCompton Scattering C/H Ratio Correction
Data OutputUSB + Ethernet
Environmental RequirementsRH < 85% (no condensation), vibration-free, non-corrosive atmosphere
Compliance StandardsASTM D4294, GB/T 17040
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelSupermini200 Cl
X-ray TubePd anode, 50 kV / 4 mA, 200 W
Detection LimitsCl: 0.1 ppm, S: 0.1 ppm, Si: 0.5 ppm, Pb: 0.2 ppm
Analytical StandardsASTM D7536 (Cl), SH/T 0842 (S), SH/T 0977 (Cl), SH/T 0993 (Si), ASTM D5059 (Pb)
Sample TypesLiquid hydrocarbons (gasoline, diesel, naphtha, jet fuel, crude oil, residuum), aqueous matrices (including wastewater), solid catalysts, polypropylene
Optical SystemMulti-crystal automatic switching spectrometer
AutomationIntegrated 12-position autosampler
SoftwareFull-featured Windows-based platform with qualitative/quantitative analysis, standardless semi-quantitative mode, spectral calibration, thin-film correction, and reference database matching
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginUSA
ModelNEX QC+
Detection PrincipleEnergy-Dispersive X-ray Fluorescence (EDXRF)
Detection Limit2.3 ppm for S
Measurement Range0–10 wt% S
Accuracy (Relative Error)±0.0001
Analysis Time< 3 min (configurable from 1–999 s)
Sample Volume< 5 mL
Elemental RangeNa (11) to U (92)
ComplianceASTM D4294, GB/T 17040
PortabilityHandheld / Field-Deployable
Environmental Operating Range15–35 °C, RH < 85% (non-condensing)
Data InterfaceUSB + Ethernet
Matrix CorrectionCompton Scattering C/H Ratio Normalization
FiltrationMulti-layer Composite Primary Beam Filters
SafetyZero hazardous waste generation (no gas, liquid or solid effluent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
Instrument TypeBenchtop
X-ray Tube Power200 W
Target MaterialPd
Detector TypesFlow-proportional Counter (F-PC) and Scintillation Counter (SC)
Analytical ElementsNa (11) to U (92)
ConfigurationMulti-channel WDXRF
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChoice Analytical
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelColor Choice hz
PriceUSD 68,500 (FOB US Port)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelMicro-Z ULS
Detection PrincipleWavelength Dispersive X-ray Fluorescence (WDXRF)
Detection Limit0.2 ppm
Measurement Range0–5 wt%
Analysis Time< 300 s
Excitation Source Power80 W
Vacuum RequirementYes (gas-free operation)
Power SupplyAC 200–240 V, 200 W
Operating Environment10–40 °C, RH < 80 %
Dimensions (W×D×H)45 × 41 × 43 cm
Weight40 kg
Compliance StandardsASTM D2622, GB/T 11140, SH/T 0842
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelMicro-Z Cl
Instrument TypeBenchtop
Excitation ModeSingle-Wavelength
AnalyteTotal Chlorine
X-ray Tube Power80 W
Detection Limit0.11 ppm
Quantification Range0–5 wt%
Analysis Time300 s
Vacuum RequirementYes (gas-free operation)
ComplianceSH/T 0977, ASTM D7536
Operating Environment10–40 °C, <80% RH
Dimensions (W×D×H)45 × 41 × 43 cm
Weight40 kg
Power SupplyAC 200–240 V
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelSupermini200 S
Instrument TypeBenchtop WDXRF Spectrometer
ExcitationMonochromatic Pd-target X-ray Tube (50 kV, 4 mA, 200 W)
Analyte ElementsTotal S (ASTM D7039), Total Cl (ASTM D5059), Total Si (SH/T 0993), Total Pb (ASTM D5059)
Detection LimitsS: 0.1 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, Pb: 0.2 ppm
Quantification Range0–99.99 wt%
Detector Linear Rangekcps
Beryllium Window Thicknessµm
Sample FormsLiquids (gasoline, diesel, naphtha, jet fuel, crude oil, residuum, aqueous samples), Solids (catalysts, polypropylene), Powders
Compliance StandardsASTM D7039, ASTM D5059, SH/T 0842, SH/T 0977, SH/T 0993
AutomationIntegrated 12-position autosampler
Optical SystemMulti-crystal automatic switching optics with monochromatic excitation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChoice Analytical
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelClarity Choice
PriceUSD 62,500 (approx. based on ¥450,000 at 1 USD = ¥7.2)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelSupermini200
Instrument TypeBenchtop WDXRF Spectrometer
Excitation SourcePd-anode X-ray tube (50 kV / 4 mA, 200 W)
Analyzed ElementsTotal S, Total Cl, Total Si, Total Pb
Detection LimitsS: 0.15 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, Pb: 0.2 ppm
Quantification Range0–99.99%
Optical ConfigurationSingle-wavelength excitation with automated multi-crystal changer (RX4, RX9, and others)
Sample Handling12-position automatic sample changer
Compliance StandardsGB/T 111140 (S), SH/T 6083 (Cl & Si), ASTM D5059 (Pb)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelSupermini200+
X-ray TubePd anode, 50 kV / 4 mA, 200 W
Detection LimitsS: 0.1 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, As: 0.2 ppm
Detection Range0–99.99%
Standard ComplianceSH/T 0842 (S), SH/T 0977 (Cl), SH/T 0993 (Si)
Optical SystemAutomated multi-crystal spectrometer with high-resolution crystal selection
Sample Handling12-position automatic sampler
Sample TypesLiquids (gasoline, diesel, naphtha, jet fuel, crude oil, residuum, water, wastewater), solids (catalysts, polypropylene, powders)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChoice Analytical
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelClarity Chorice hz
PriceUSD 58,000 (FOB US Port)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginUSA
ModelNEX CG II
Element RangeNa (11) to U (92)
Detection Limits (typical for petroleum)Si 1.1 ppm, P 0.8 ppm, S 0.5 ppm, Cl 0.4 ppm, Mn 0.9 ppm, Fe 0.7 ppm, Pb 0.7 ppm
Concentration Range0.11 ppm – 10%
Energy Resolution<140 eV (Mn Kα)
Repeatability0.05% RSD
DetectorSilicon Drift Detector (SDD) with Peltier cooling
Excitation SourcePd anode X-ray tube, max 50 kV / 50 W
Polarization Optics5-position polarized secondary target assembly
GeometryCartesian 3D configuration (X-ray tube → polarizer → sample → detector)
Sample Volume5 mL
Autosampler15-position carousel
Calibration MethodCompton scattering C/H ratio correction
Data OutputUSB 2.0 and Ethernet (RJ-45), CSV/PDF export
Dimensions463 × 492 × 382 mm (W×D×H)
PowerAC 200–240 V, 50/60 Hz, 1.6 A
Operating Environment18–28 °C, RH <75% non-condensing, vibration-free, non-corrosive atmosphere
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginUSA
ModelNEX DE
Detection RangeNa to U
Sample Volume5 mL
Analysis Time30–900 s (standard: 300 s)
ComplianceASTM D4294, ASTM D8252, ASTM D6481, GB/T 17040
Excitation FiltrationMulti-layer composite filters
Operating Temperature10–35 °C
Relative Humidity<80% RH (non-condensing)
Data OutputUSB + Ethernet
SoftwareQuantEZ
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
Instrument TypeBenchtop
X-ray Tube Power200 W
Elemental RangeNa (11) to U (92)
DetectorFlow Proportional Counter (F-PC) and Scintillation Counter
Sample Handling12-position Automatic Sampler
Operating AtmosphereAir, He, or Vacuum
Dimensions580(W) × 670(H) × 680(D) mm
Power Supply200–240 V, 10 A
Grounding Resistance<30 Ω
Ambient Temperature10–40 °C
Relative Humidity<80% RH
Show next