Physical Property Testing Instruments
Filter
Showing 5131–5160 of 12500 results
| Brand | Jinhoo |
|---|---|
| Model | JHR-500P |
| Type | Electromechanical Tensile & Compression Testing System |
| Load Capacity | 5 kN |
| Force Sensor Standard | 20 N (2 kgf), expandable with optional multi-range load cells |
| Accuracy Class | 0.2 |
| Force Measurement Range | 0.4–100% FS |
| Force Resolution | ±1/300,000 of full scale, unsegmented across entire range |
| Deformation Measurement Range | 0.2–100% FS |
| Deformation Accuracy | ±0.2% of reading |
| Deformation Resolution | ±1/300,000 of maximum deformation |
| Displacement Accuracy | ±0.2% of reading |
| Displacement Resolution | 0.02 µm |
| Crosshead Speed Range | 0.001–200 mm/min |
| Speed Control Accuracy | ±0.2% of set value |
| Strain Rate Range | 0.001–2% FS/min |
| Strain Rate Control Accuracy | ±0.2% of set value |
| Effective Test Width | 370 mm or 210 mm (configurable) |
| Maximum Tensile Travel | 700 mm or 1200 mm (configurable) |
| Maximum Compression Stroke | 700 mm |
| Frame Type | Dual-column portal structure |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 0.4 kW |
| Net Weight | 160 kg |
| Dimensions (W×D×H) | 800 × 410 × 1600 mm |
| Compliance | ASTM E4, ASTM E8/E21, ISO 6892-1, ISO 7500-1, GB/T 228.1, JIS Z2241, DIN 50125 |
| Software Platform | Windows 2000/XP/7 compatible, bilingual (English/Chinese), GLP-compliant data handling |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | JST-090 |
| Chamber Dimensions (W×D×H) | 90×60×50 cm |
| Interior Material | PVC & PP |
| Test Temperature Range | 35±1°C (NSS), 50±1°C (AASS/CASS) |
| Saturated Air Tank Temperature | 47±1°C (NSS), 63±1°C (AASS/CASS) |
| Saturation Pressure | 0.8–2.0±0.01 kg/cm² |
| Fog Output | 1.0–2.0 mL/80 cm²/h |
| pH Range | 6.5–7.2 (NSS), 3.0–3.2 (AASS/CASS) |
| Chamber Volume | 270 L |
| Water Reservoir Capacity | 25 L |
| Power Supply | AC 1φ 220 V, 50 Hz, 30 A |
| Compliance | ASTM B117, ISO 9227, GB/T 2423.17, GJB 150.11A, CNS 3627/3885/4519/7669/8886 |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Domestic OEM Manufacturer |
| Product Category | Domestic |
| Model | JTH-150P |
| Pricing | Available Upon Request |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JTSE Series |
| Price Range | USD 1,400 – 14,000 (FOB Shanghai) |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −70 °C |
| Thermal Shock Range | −70 °C to +150 °C |
| Temperature Stability | ±0.5 °C (steady-state) |
| Temperature Uniformity | ±1.5 °C (at 60% load, per IEC 60068-3-5) |
| Heating Rate | ≥10 °C/min (typical, 20 °C to +150 °C) |
| Cooling Rate | ≥12 °C/min (typical, 20 °C to −70 °C) |
| Humidity Control Capability | Optional integrated humidity module (5–95% RH, dew point ≤ −75 °C at −70 °C operation) |
| Compressor System | Dual-stage hermetic scroll compressors (Emerson Copeland ZB series or Danfoss HPU series, OEM-specified) |
| Calibration | Full-range CNAS-accredited calibration available (−70 °C to +150 °C, 10–95% RH), traceable to NIM (National Institute of Metrology, China) |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | JH-SSC Series |
| Type | Benchtop Environmental Test Chamber |
| Cooling Method | Air-Cooled |
| Temperature Range | 15–45 °C |
| Humidity Range | 30–98 % RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±1 °C (high-temp), ±2 °C (low-temp) |
| Humidity Uniformity | ≤ ±3 % RH |
| Humidity Fluctuation | ±3 % RH |
| Heating Rate | 1.0–3.0 °C/min |
| Compliance | ASTM B117, ISO 9227 (NSS), GB/T 2423.17 |
| Application Focus | Automotive Components, Electronics Enclosures, Plated Fasteners, PCB Substrates, Aerospace Hardware |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | SH-SSC |
| Spray Method | Continuous Atomization |
| Fog Output | 1–2 mL per 80 cm² per hour |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| De-fogging Method | Air-Compression Exhaust |
| Compliance | Designed to meet IEC 60068-2-11, GB/T 2423.17, ASTM B117 (configuration-dependent) |
| Chamber Construction | PVC-coated steel frame with acid-resistant acrylic viewing window |
| Temperature Range | 35 ± 2 °C (standard neutral salt spray), optionally configurable for cyclic corrosion testing (CCT) protocols |
| Brand | Jinhua |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JH-10L to JH-300L |
| Max Load Capacity | 10 kN to 300 kN |
| Force Resolution | 1/500,000 (full-scale, unsegmented) |
| Force Accuracy | ±1% of reading |
| Speed Range | 0.01–500 mm/min (infinitely variable) |
| Speed Accuracy | ±1% |
| Crosshead Travel (Tension) | 650–750 mm |
| Effective Test Width | 375–550 mm |
| Power Supply | Single-phase 220 V ±10%, 50 Hz or Three-phase 380 V ±10%, 50 Hz |
| Operating Environment | 10–35 °C, RH ≤80% |
| Weight | 500–1900 kg |
| Brand | Jinhuatester |
|---|---|
| Model | BLD-01 |
| Test Principle | 180° peel adhesion measurement per ASTM D3330, ISO 8510-2, and GB/T 2792 |
| Load Capacity | 200 N (standard) |
| optional ranges | 5 N, 10 N, 30 N, 50 N, 100 N, 300 N |
| Accuracy Class | 0.5 |
| Force Resolution | 0.001 N |
| Speed Range | 1–500 mm/min (infinitely variable) |
| Effective Travel | 330 mm |
| Displacement Resolution | 0.01 mm |
| Specimen Width Range | < 55 mm |
| Peel Angle | 180° horizontal |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 30 W |
| Dimensions (L×W×H) | 635 × 300 × 200 mm |
| Net Weight | 22 kg |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CHY-01 |
| Measurement Range | 0–5 mm (custom fixtures available) |
| Measurement Pressure | 17.5 ± 1 kPa (for films), 100 ± 1 kPa (for paper, optional fixture required) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode) |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions (W×D×H) | 454 × 352 × 500 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 30 kg |
| Interface | RS232 serial port |
| Standard Accessories | Main unit, calibration gauge blocks, thermal micro-printer |
| Optional Accessories | PC-based measurement software, RS232 communication cable, calibrated weight kits, automated multi-point sample feeder |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CHY-01 |
| Measurement Range | 0–5 mm (customizable fixtures available) |
| Measuring Pressure | 17.5 ± 1 kPa (for films), 100 ± 1 kPa (for paper) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode) |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions | 454 × 352 × 500 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 30 kg |
| Interface | RS232 |
| Compliance | ASTM D6988, ISO 4593, ISO 534, GB/T 6672, GB/T 451.3 |
| Brand | Jinhuatester |
|---|---|
| Model | DBH-01 |
| Measurement Principle | Capacitive Grid (Capacitance-Based Contact Sensing) |
| Measuring Range | 0–12.7 mm |
| Resolution | 0.001 mm |
| Accuracy | ±0.003 mm |
| Repeatability | ≤4 µm |
| Sample Diameter Range | φ20–φ300 mm |
| Max. Sample Height | 350 mm |
| Display | 7-inch TFT True Color Touchscreen |
| Data Storage | Up to 100 test groups (10 values/group) |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (W×D×H) | 450 × 430 × 635 mm |
| Weight | 20 kg |
| Operating Environment | 15–35 °C, 40–60 % RH |
| Compliance | YBB00332002–2015, YBB00332003–2015, YBB00032004–2015, GB 12415–90, GB 2641–1990, GB 2639–1990 |
| Brand | Jinhuhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor & OEM Partner |
| Country of Origin | China |
| Model | JH-2026 High-Low Temperature Environmental Test Chamber |
| Price Range | USD 750 – 7,200 (FOB Shanghai) |
| Temperature Range | −70 °C to +150 °C |
| Refrigeration Method | Dual-stage Compressor Cooling |
| Explosion-Proof Configuration | Available (IEC 60079-0 / GB 3836.1 Certified) |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ≤2.0 °C (at steady state) |
| Temperature Deviation | ±2.0 °C (vs. setpoint, per IEC 60068-3-5) |
| Heating Rate | ≤60 min (−70 °C → +150 °C, empty chamber) |
| Cooling Rate | ≤45 min (25 °C → −40 °C), ≤60 min (25 °C → −70 °C), ≤80 min (25 °C → −70 °C with full thermal load) |
| Interior Dimensions | Custom-engineered (standard range: W300–2000 mm × D300–1500 mm × H300–1800 mm) |
| Brand | Jinhuhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | JH-Series Polyimide (PI) High-Temperature Vacuum Curing Oven |
| Temperature Range | 150 °C to 450 °C |
| Temperature Uniformity | ±1.0 °C (at 450 °C, 32-point measurement) |
| Temperature Stability | ±0.2 °C to ±0.5 °C |
| Temperature Deviation | ≤±2.0 °C |
| Heating Rate | Up to 20 °C/min |
| Cooling Rate | From 150 °C to −40 °C in ≤45 min |
| Oxygen Concentration Control | ≤5 ppm (real-time laser O₂ sensing + N₂ purge) |
| Vacuum Level | 5×10⁻⁴ Pa (turbomolecular + roots pump system) |
| Chamber Volume | Customizable (from 30 L to >5 m³) |
| Compliance | SEMI S2/S8, ISO 9001, AS9100D, GB/T 2423.2 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJ211 |
| Quotation | USD 6,750 (FOB Shanghai) |
| Instrument Type | Electromechanical Universal Tensile Tester |
| Max Test Load | 200 kN |
| Force Measurement Range | 1%–100% of Full Scale (FS) |
| Force Accuracy | ±0.5% of reading |
| Travel Distance | 800 mm |
| Displacement Resolution | 0.001 mm |
| Speed Range | 0.001–500 mm/min (programmable, closed-loop controlled) |
| Speed Accuracy | ±0.5% of set value |
| Crosshead Effective Width | 420 mm |
| Load Cell | High-precision USA-made strain-gauge sensor (500,000-count resolution, no internal range switching) |
| Control System | Panasonic全数字 AC servo drive & controller |
| Software Platform | Full-digital closed-loop test management system supporting constant load, constant strain, constant displacement, and multi-step ramp profiles |
| Safety Features | Dual-mode overload protection (10% over full scale), electronic limit switches, real-time software diagnostics, automatic return-to-start |
| Power Supply | 220 VAC, 50 Hz, 750 W |
| Dimensions (L×W×H) | 690 × 465 × 1970 mm |
| Net Weight | 280 kg |
| Compliance | ASTM E4, ASTM E8, ISO 6892-1, GB/T 228.1–2021, JJG 475–2018 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Fengxian |
| Price | USD 6,450 (FOB Shanghai) |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | (12 ± 1) °C/6 min or (5 ± 0.5) °C/6 min |
| Temperature Accuracy | ±1 °C |
| Deformation Measurement Range | 0–1 mm |
| Deformation Resolution | 0.01 mm |
| Heat Transfer Medium | Methyl Silicone Oil |
| Heating Power | 4 kW |
| Cooling Modes | Natural convection above 150 °C |
| Power Supply | AC 220 V, 20 A, 50 Hz |
| Dimensions (L×W×H) | 540 × 520 × 1360 mm |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BJ-124 |
| Price | USD 4,050 (FOB Shanghai) |
| Brand | Jiubin |
|---|---|
| Model | BJ-220 |
| Temperature Range | −70 °C to 150 °C |
| Humidity Range | 20–98 %RH |
| Temperature Uniformity | ±0.5 °C |
| Humidity Uniformity | ±3–5 %RH |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.5 %RH |
| Internal Dimensions (W×H×D) | 400–1000 mm × 500–1000 mm × 400–1000 mm |
| Power Supply | 220 V / 380 V, 50 Hz |
| Compliance | GB/T 10592–1989, ANSI/EIA-364-105–1999 |
| Brand | Jiubin |
|---|---|
| Model | BJ-236 |
| Type | Oscillating Disk Curemeter (ODR) / Rotorless Curemeter |
| Temperature Range | 100–200 °C |
| Heating Rate | <10 min to setpoint |
| Oscillation Frequency | 1.7 Hz (100 rpm) |
| Oscillation Angle | ±0.5° |
| Rotor Diameter (rotor-type) | 35.55 ±0.07 mm |
| Torque Range | 0–30 N·m |
| Torque Resolution | 0.01 N·m |
| Power Supply | 220 V AC |
| Pneumatic Pressure | 0.5 MPa |
| Data Output | Date, Time, Temperature, Lab ID, Cure Curve, Temperature Profile, ML, MH, t₉₀, ts₁, tc₅₀ |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | GB/T3682-2000 |
| Temperature Control Range | 50–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Power Consumption | 500 W |
| Temperature Recovery Time | 4 min |
| Piston Travel Distance | 30 mm |
| Displacement Resolution | 0.1 mm |
| Barrel Inner Diameter Tolerance | ±0.025 mm |
| Piston Head Diameter Tolerance | ±0.01 mm |
| Piston Head Length Tolerance | ±0.1 mm |
| Die Capillary Inner Diameter Tolerance | ±0.005 mm |
| Standard Weights | 0.325 kg (including piston rod), 0.875 kg, 0.96 kg, 1.2 kg, 1.64 kg |
| Compliance | GB/T 3682–2000, ISO 1133:1997, ASTM D1238 |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GJX-300 |
| Price | Upon Request |
| Test Load Capacity | 300 kN |
| Effective Load Range | 6–300 kN |
| Load Indication Relative Error | ±1% |
| Load Resolution | 5 N |
| Displacement Indication Relative Error | ±1% |
| Loading Rate | 100–5000 N/s (adjustable) |
| Screw Travel | 100 mm |
| Test Zone Height | 2050 mm |
| Power Supply | 1.5 kW, AC 200 V ±10% |
| Dimensions (L×W×H) | 2000×1100×600 mm |
| Weight | 1250 kg |
| Brand | Jiubin Instruments |
|---|---|
| Model | FMVSS 302 |
| Origin | Shanghai, China |
| Compliance | FMVSS 302, GB 8410-2006, PV3357 |
| Flame Height | 38 mm (adjustable per standard) |
| Ignition Time | 15 s ± 0.2 s |
| Sample Holder | U-shaped stainless steel fixture |
| Burner Nozzle ID | 9.5 mm |
| Nozzle-to-Sample Distance | 19 mm ± 1 mm |
| Gas Supply | Liquefied petroleum gas (LPG) or natural gas with calorific value 35–38 MJ/m³ |
| Comb Specifications | ≥110 mm length |
| Timer Accuracy | ±0.5 s |
| Temperature Range | ≥150 °C, ±1 °C |
| Ruler Accuracy | ±1 mm, 400 mm min scale |
| Chamber Dimensions (L×W×H) | 1300 × 800 × 1600 mm |
| Net Weight | ~120 kg |
| Sample Dimensions | 102 × 356 × t mm (t ≤ 13 mm) |
| Minimum Specimens | 5 per orientation |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-1000 |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (D × W × H) |
| Test Dust | Dry Talcum Powder |
| Dust Concentration | 2 kg/m³ |
| Airflow Velocity | 2 m/s |
| Temperature Range | Ambient to +60 °C |
| Sieve Specification | Nominal Wire Diameter 50 µm, Nominal Mesh Spacing 75 µm |
| Heating System | Integrated Resistive Heater |
| Control System | Fuji Electric PID Controller (0.2-class accuracy), Moeller Programmable Timer for Dust Cycling & Vibration Timing |
| Chamber Construction | Exterior – 1.5 mm A3 Steel with Epoxy Powder Coating |
| Viewing Window | Tempered Glass with Manual Wiper |
| Sealing | Imported EPDM Gasket |
| Internal Power Outlet | IP54-rated Dust-Protected Socket |
| Adjustable Shelving | 2-tier, Height-Adjustable Stainless Steel Racks |
| Dust Distribution Mechanism | Centrifugal Blower + Eccentric Vibrator-Assisted Bottom Feed |
| Compliance | Designed in accordance with IEC 60529 (IP5X/IP6X), MIL-STD-810H Method 510.7, GB/T 2423.37–2008 |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-117H |
| Maximum Test Load | 50 kN |
| Force Accuracy | ±0.5% |
| Displacement Resolution | 0.01 mm |
| Crosshead Speed Range | 0.01–200 mm/min (infinitely variable) |
| Tensile/Compression Test Space | 1000 mm |
| Test Width | 400 mm |
| Power Supply | 1.25 kW, 220 V, 50 Hz |
| Operating Environment | 10–35 °C, 20–80% RH |
| Compliance | GB/T 9647, ISO 9969, ASTM D2412, EN 12285-1, DIN 16961 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-117Y |
| Price | Upon Request |
| Max Test Load | 50 kN |
| Force Accuracy | ±0.5% FS |
| Force Range | 0.25–50 kN (single-range, fully digital) |
| Displacement Resolution | 0.01 mm |
| Crosshead Speed | 0.01–200 mm/min (infinitely variable) |
| Tensile/Compression Test Space | 1000 mm |
| Test Width | 400 mm |
| Power Supply | 1.25 kW, 220 V, 50 Hz |
| Operating Environment | 10–35 °C, 20–80% RH |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-120A |
| Maximum Test Load | 100 kN |
| Accuracy Class | 0.5 |
| Load Resolution | 0.001 N |
| Load Accuracy | ±0.05% |
| Speed Range | 0.001–500 mm/min |
| Effective Stroke | ~1000 mm |
| Displacement Encoder Resolution | 1000 P/R (±0.005%) |
| Control System | Full-digital triple-closed-loop (force, displacement, strain) with adaptive PID algorithm |
| Power Supply | 380 V AC |
| Weight | 860 kg |
| Dimensions (W×D×H) | 1200 × 650 × 1800 mm |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-121 |
| Price | USD 4,850 (FOB Shanghai) |
| Max Load Capacity | 20 kN |
| Effective Test Height | 800 mm |
| Force Sensor | Transcell (USA), 20 kN |
| Drive System | Panasonic AC Servo Motor & Controller (Japan) |
| Force Resolution | ±1/500,000 FS |
| Force Accuracy | ±0.5% of reading |
| Displacement Resolution | 0.05 mm |
| Displacement Accuracy | ±0.5% of reading |
| Strain Measurement Range | 0.2–100% FS |
| Strain Resolution | ±1/300,000 FS |
| Strain Accuracy | ±0.5% of reading |
| Speed Range | 0.001–500 mm/min (infinitely variable, segmented control) |
| Speed Accuracy | ±1% (<0.01 mm/min) |
| Force Rate Control | 0.5–6% FS/s |
| Strain Rate Control | 0.2–6% FS/s |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 800 × 400 × 1800 mm |
| Weight | ~300 kg |
| Software | Dual-language (English/Chinese) PC-based testing platform compliant with ASTM D903, ISO 8510-2, GB/T 2790-1995 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-124 |
| Capacity Range | 0–5 kN (user-selectable) |
| Load Cell Accuracy | ±0.5% of full scale |
| Effective Test Width | 380 mm |
| Maximum Tensile Stroke | 1000 mm |
| Test Speed Range | 0.001–500 mm/min (infinitely variable) |
| Displacement Resolution | 1/200,000 |
| Displacement Accuracy | ±0.005% of reading |
| Control System | Servo motor (Japan-made) + AC motor (Taiwan-made) |
| Mechanical Drive | Precision ball screw (Taiwan-made) + high-strength backlash-free lead screw (Korea-made) |
| Safety Features | Upper/lower mechanical limits, emergency stop button |
| Power Supply | 220 V / 380 V, 50 Hz |
| Net Weight | 1080–1180 kg |
| Dimensions (W×D×H) | 1280 × 950 × 1800 mm |
| Display Interface | Dual-mode — microcomputer panel + PC-based GUI |
| Unit Options | g, kg, N, kN, lbf, lb |
| Standard Compliance | ISO 7500-1, ASTM E4, ASTM E8/E9, GB/T 228.1 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-126S |
| Max Test Load | 200 kgf (1.96 kN) |
| Load Accuracy | ±0.01% FS |
| Force Resolution | 0.001 N |
| Speed Range | 5–500 mm/min (adjustable, stepless) |
| Effective Travel | ~800 mm |
| Displacement Encoder | 1000 P/R |
| Position Accuracy | ±0.005% (Japan-made) |
| Compliance | ASTM D1683, ISO 13936-1/2, ISO 13935-1/2, GB/T 13772.1–2, GB/T 13773.1–2, JIS L1096, GB/T 3923.1–2, GB/T 3917.2–3 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-3 |
| Oxygen Measurement Range | 0–100% O₂ |
| Resolution | 0.1% O₂ |
| Accuracy | ±0.4% O₂ |
| Response Time | <10 s |
| Display Precision | 0.1% |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 45–75% RH |
| Power Supply | 220 V ±15%, 50 Hz, 100 W |
| Gas Supply | Industrial-grade oxygen (GB/T 3863) and nitrogen (GB/T 3864) |
| Input Pressure | 0.25 MPa |
| Working Pressure | 0.1 MPa |
| Sample Types | Self-supporting solid specimens (e.g., plastics, rubber, textiles, films, cables, wood) |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JB-3500F |
| Pricing | Available Upon Request |