Physical Property Testing Instruments
Filter
Showing 5461–5490 of 12515 results
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | JW-TB400 Pharmaceutical Excipient-Specific Specific Surface Area and Pore Size Analyzer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption Method |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | >0.0005 m²/g |
| Pressure Range | 1×10⁻⁵ to 0.998 atm |
| Theoretical Basis | Static Volumetric Adsorption Method |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | JW-TB400 Rubber-Specific Specific Surface Area Analyzer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption Method |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | >0.0005 m²/g |
| Pressure Range | 10⁻⁵–0.998 P/P₀ |
| Analytical Theory | Static Volumetric Adsorption |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Vapor Adsorption Analyzer |
| Model | JW-ZQ200C |
| Weighing Range | 0.0001 g – 100 g |
| Weighing Resolution | 0.0001 g |
| Temperature Control Range | Ambient to 400 °C |
| Relative Humidity Range | 30 %RH – 60 %RH |
| RH Accuracy | ±0.11 %RH |
| Vacuum Base Pressure | ≤1 × 10⁻⁸ Pa |
| Pore Size Analysis Range | 0.35 nm – 500 nm |
| Specific Surface Area Range | ≥0.005 m²/g (no upper limit) |
| Total Pore Volume Range | ≥0.0001 cm³/g (no upper limit) |
| Integrated Pressure Sensors | 1000 torr / 10 torr / 0.1 torr (vapor station) |
| Dual Cold Trap System | Independent cryo-traps for degassing and vapor analysis stations |
| Pumping System | External dual-stage rotary vane pump (anti-backflow auto-control) + internal German-sourced turbomolecular pump (2nd stage) |
| Data Acquisition | Ethernet-connected networked DAQ card |
| Dimensions (L×W×H) | 900 mm × 570 mm × 920 mm |
| Net Weight | 95 kg |
| Operating Environment | 15–40 °C, 30–60 %RH |
| Power Supply | AC 220 V ±20 V, 50/60 Hz |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Vapor Sorption Analyzer |
| Gravimetric Resolution | 0.0001 g |
| Mass Range | 0.0001–100 g |
| Temperature Control Range | Ambient to 400 °C |
| Relative Humidity (RH) Range | 30–60 %RH |
| RH Accuracy | ±0.11 %RH |
| Vacuum Base Pressure | ≤1×10⁻⁸ Pa |
| P₀ Measurement System | Dual-stage Rotary Vane Pump (anti-backstreaming) + Integrated Turbo-Molecular Pump |
| Sorption Analysis Modules | BET Surface Area, Langmuir Surface Area, External Surface Area, Total Pore Volume, Micropore Volume, Mesopore/Macropore Volume Distribution (2–500 nm), Micropore Size Distribution (0.35–2 nm) |
| Sample Pretreatment Temp | Ambient to 400 °C |
| Dimensions (L×W×H) | 900 × 570 × 920 mm |
| Net Weight | 95 kg |
| Operating Environment | 15–40 °C, 30–60 %RH |
| Power Supply | AC 220 V ±20 V, 50/60 Hz |
| Data Acquisition | Ethernet-connected networked DAQ card |
| Cryogenic Traps | Dual independent cryo-traps (degassing station & vapor analysis station) |
| Pressure Sensors | 1000 torr / 10 torr / 0.1 torr (vapor station) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Model | Matrix 1000 Series |
| Analysis Stations | 12 |
| Pore Size Range | 0.35 – 500 nm |
| Pressure Range | 10⁻⁸ – 0.998 atm |
| Theoretical Models | HK, SF, BJH, MP, t-plot, DR, DA, DFT/NLDFT |
| Ambient Temperature Range | 15 – 40 °C |
| Ultimate Vacuum | 10⁻⁸ Pa |
| Adsorption Gases | N₂, Ar, Kr, CO₂, CH₄, C₂H₄, C₂H₆, H₂O, benzene, toluene, xylene, NH₃, SO₂, H₂S |
| Degassing Temp Range | RT – 400 °C (±0.1 °C) |
| Pressure Sensors | 1000 Torr (0.05% F.S.), optional 10/1/0.1 Torr for micropore resolution |
| Thermal Stability | ±0.1 °C valve box temperature control |
| Corrosion Protection | FFKM seals + fluoropolymer-coated gas path |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Product Type | Domestic |
| Model | YG-23A Mercury Intrusion Porosimeter (Pore Size Distribution & Porosity Analysis) |
| Price | Upon Request |
| Pore Size Range | 30 nm – 126 µm |
| Pressure Range | 0.01 – 50 MPa |
| Pore Volume Range | 0.3 – 3.5 mL |
| Measurement Accuracy | ≤ 0.5% |
| Sample Chamber Volume | Up to 15 cm³ |
| Vacuum Level | ≤ 0.05 Pa |
| Blank Volume at 50 MPa | ~0.25 mL |
| Safety | Integrated mercury vapor containment system |
| Compliance | ISO 15901-1:2005, GB/T 21650.1-2008 |
| Analysis Outputs | Cumulative pore volume, cumulative specific surface area, average pore diameter, pore size distribution curve, pore throat ratio, intrusion/extrusion hysteresis curves |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YG-97A Mercury Intrusion Porosimeter (Shale Porosity) |
| Price | Upon Request |
| Pore Diameter Range | 30 nm – 600 µm |
| Pressure Range | 0.01 – 50 MPa (7250 psi) |
| Vacuum Level | ≤ 0.05 Pa |
| Sample Chamber Volume | Up to 15 cm³ |
| Measurement Accuracy | ≤ 0.5% |
| Blank Volume at 50 MPa | ~0.25 mL |
| Safety | Integrated Mercury Vapor Containment System |
| Compliance | ISO 15901-1:2005, GB/T 21650.1-2008 |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YG-97A Mercury Intrusion Porosimeter |
| Price | Upon Request |
| Pore Diameter Range | 30 nm – 600 µm |
| Pressure Range | 0.01 – 50 MPa (7250 psi) |
| Vacuum Level | ≤ 0.05 Pa |
| Sample Chamber Volume | Up to 15 cm³ |
| Measurement Accuracy | ≤ 0.5% |
| Blank Volume at 50 MPa | ~0.25 mL |
| Safety | Integrated Mercury Vapor Containment System |
| Compliance | ISO 15901-1:2005, GB/T 21650.1–2008 |
| Brand | k-Space Associates |
|---|---|
| Origin | USA |
| Model | kSA MOS US |
| Scan Area | 300 mm × 300 mm (up to 2 m optional) |
| Scanning Speed | up to 20 mm/s (X/Y) |
| Positional Resolution | 1 µm |
| Mean Curvature Resolution | 5 × 10⁻⁵ m⁻¹ (1σ) |
| Stress Measurement Range | 3.2 × 10⁵ Pa to 7.8 × 10⁹ Pa (1σ) |
| Stress Resolution | < 0.32 MPa or 1% (1σ) |
| Stress Repeatability | 0.02 MPa (1σ) |
| Curvature Repeatability | < 5 × 10⁻⁵ m⁻¹ (1σ) |
| Measurement Modes | Region-of-Interest, Linear Multi-Point, Full-Sample Scan |
| Output | 2D curvature mapping, quantitative stress distribution imaging, radius of curvature, wafer bow, and stress intensity |
| Brand | k-Space |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | RDA |
| Pricing | Upon Request |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BrillianSe |
| Quotation | Upon Request |
| Detector Type | High-Resolution CMOS Semiconductor Chip |
| Scanning Method | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| X-ray Energy Range | Up to 120 kV |
| Spatial Resolution | Up to 5.6 µm (0.1 MTF at 90 cycles/mm) |
| Dimensions | 269 mm × 245 mm × 117 mm (L × W × H) |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Model | inCiTe 3D |
| Detector Type | High-Resolution CMOS-Based Direct-Conversion a-Se (BrillianSe) Sensor |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | Up to 5.6 μm (0.1 MTF at 90 cycles/mm) |
| X-ray Energy Range | 40–110 kV |
| Field of View | 32 mm × 32 mm (direct detection) |
| Maximum Sample Dimensions | Ø25 mm × 100 mm (diameter × height/length) |
| System Footprint | 1500 mm × 580 mm × 500 mm (L × W × H) |
| Pixel Pitch | 8 μm |
| Detector Resolution | 4096 × 4096 (16.8 MP) |
| Effective DQE | High across 40–120 keV |
| Phase-Contrast Mechanism | Propagation-Based (Grating-Free, In-Line) |
| Minimum Focal Spot Size | 2 μm |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | inCiTe |
| Detector Type | High-Resolution CMOS-Based Direct-Conversion Semiconductor Detector (BrillianSe™) |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | Up to 5.6 µm (0.1 MTF at 90 cycles/mm) |
| X-ray Source Spot Size | ≤5 µm |
| X-ray Energy Range | 40–100 kV |
| Maximum Sample Volume | Ø25 mm × 100 mm (diameter × height/length) |
| System Dimensions | 1500 mm × 580 mm × 500 mm (L × W × H) |
| Pixel Pitch | 8 µm |
| Detector Format | 16 MP (4096 × 4096) |
| Field of View | 32 mm × 32 mm |
| Phase-Contrast Mechanism | Propagation-Based (Grating-Free, In-Line) |
| Brand | Kaelge |
|---|---|
| Origin | Germany |
| Model | IMPact 5.5/15(25) |
| Impact Energy Range | 0.5–5.5 J (IMPact 5.5) |
| Compliance Standards | EN ISO 179, EN ISO 180, ASTM D 256 (Methods A & B), ISO 8256 |
| Test Configurations | Charpy (simply supported beam), Izod (cantilever beam), Tensile Impact |
| Control System | Microprocessor-based with keypad and LCD display (4-language support) |
| Output Interfaces | RS-232 serial port, parallel printer port |
| Key Functions | Automatic pendulum braking, built-in sample centering for Charpy fixtures, real-time energy calculation (absorbed energy, recovered elastic energy, rise angle, impact velocity), on-access auto-test initiation, pendulum calibration verification and report generation, FIFO storage of up to 50 test results with statistical evaluation (mean, standard deviation) |
| Origin | USA |
|---|---|
| Manufacturer | Kaltec (USA) |
| Instrument Type | Rotational Rheometer |
| Max Shear Rate | 1–1.38×10⁵ s⁻¹ (standard), up to 1.85×10⁵ s⁻¹ (upgraded) |
| Torque Range | 1.0×10⁴–1.8×10⁷ dyn·cm |
| Shear Stress Range | 80–6.0×10⁵ dyn/cm² |
| Recommended Viscosity Range | 1–4.5×10³ cP (10⁻² P) |
| Weight | 62 kg |
| Dimensions (H×W×D) | 81×64×46 cm |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S0104-4 |
| Steam Output Rate | 65–390 g/h |
| Steam Reservoir Capacity | 3.785 L (externally insulated) |
| Heater Power | ≤500 W (AC 100 V) |
| Thermal Loss | <75 W at −3 °C ±1 °C |
| Nozzle Internal Diameter | Φ15 mm, Length: 100 mm |
| Exhaust Fan Flow Rate | 0.05–0.1 m³/min at 49 Pa |
| Compliance | SAE J953 (JUN1984), EEC Regulation No. 317, GB 11555–2009 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S0104-4 |
| Steam Output | 65–390 g/h |
| Thermal Loss | <75 W at –3 °C ±1 °C |
| Water Reservoir Capacity | 3.785 L (externally insulated) |
| Heater Power | up to 500 W, AC 100 V |
| Nozzle ID | Φ15 mm, Length: 100 mm |
| Exhaust Fan Flow | 0.05–0.1 m³/min at 49 Pa |
| Output Orifices | six × Φ6.3 mm |
| Compliance | SAE J953 (JUN84), EEC/317, GB 11555–2009 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S0104-4 |
| Steam Output | 65–390 g/h |
| Steam Reservoir Capacity | 3.785 L (externally insulated) |
| Heating Power | up to 500 W AC 100 V |
| Thermal Loss | <75 W at ambient –3 °C ±1 °C |
| Nozzle ID | Φ15 mm, Length: 100 mm |
| Exhaust Fan Flow Rate | 0.05–0.1 m³/min @ 49 Pa |
| Orifice Configuration | 6 × Φ6.3 mm top-mounted steam outlets |
| Compliance | SAE J953 (JUN84), EEC/317, GB 11555–2009 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | S0104-4 |
| Steam Output Rate | 65–390 g/h |
| Thermal Loss | <75 W (at ambient –3 °C ±1 °C) |
| Water Reservoir Capacity | 3.785 L (externally insulated) |
| Heater Power | up to 500 W, AC 100 V |
| Nozzle Internal Diameter | Φ15 mm, Length: 100 mm |
| Exhaust Fan Flow Rate | 0.05–0.1 m³/min (at 49 Pa) |
| Output Orifices | six × 6.3 mm diameter ports on top |
| Compliance | SAE J953 JUN84, EEC/317, GB 11555–2009 |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Instrument Type | Free-Fall Dart Impact Tester |
| Standards Compliance | ASTM D1709, ISO 7765-1 |
| Impact Energy Range | As per manufacturer’s specification sheet |
| Impact Velocity | As per manufacturer’s specification sheet |
| Dart Mass Options | Standardized (e.g., 50 g, 100 g, 200 g) per ASTM/ISO |
| Maximum Drop Height | Adjustable up to 2,000 mm (typical range) |
| Load Cell Capacity | Configurable (e.g., ±500 N full scale) |
| Test Mode | Single-dart or multi-dart statistical mode (50% failure threshold determination) |
| Data Output | Analog + digital (RS-232 / USB) |
| Safety Enclosure | Interlocked transparent polycarbonate shield |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | DIN 53438 |
| Compliance | DIN 53438, DIN 4102-B2 |
| Chamber Dimensions (W×H×D) | 730 × 950 × 450 mm |
| Weight | 65 kg |
| Sample Holder | Adjustable-angle stainless steel support with interchangeable fixtures |
| Burner | Tilt-adjustable Bunsen-type burner with calibrated flame height indicator |
| Gas Control | Precision mass-flow regulated propane/butane supply system |
| Viewing Window | Heat-resistant borosilicate glass front panel |
| Exhaust | Integrated axial exhaust fan with duct interface |
| Safety Features | Front-access design, thermal insulation, fail-safe gas shutoff |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 4E-MC |
| Pricing | Upon Request |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | FMVSS 302 |
| Compliance | FMVSS 302, ISO 3795, DIN 75200 |
| Chamber Material | V4A Stainless Steel (1.4404 / AISI 316L) |
| Sample Holder | Type A & Type B Configurations |
| Flame Source | Adjustable Propane/Butane Burner with Precision Needle Valve |
| Viewing Window | Heat-Resistant Borosilicate Glass |
| Service Access | Side Maintenance Door |
| Optional Fixtures | VW TL 1010 & Porsche PTL 8501 Compliant Sample Clamps |
| Dimensions (W×H×D) | 500 × 385 × 245 mm |
| Weight | 22 kg |
| Brand | Karg |
|---|---|
| Origin | Germany |
| Model | HST 53-3 |
| Temperature Control Range | Room Temperature +5°C to 300°C |
| Internal Chamber Volume | 53 L |
| Internal Dimensions (W×H×D) | 400 × 400 × 330 mm |
| External Dimensions (W×H×D) | 635 × 620 × 575 mm |
| Timer Range | 0–99 hours |
| Power Supply | 220 V AC ±10% |
| Compliance | DIN EN 60811-2-1 |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | Kofler HB |
| Type | Hot-block melting point apparatus |
| Principle | Kofler hot-plate method (linear temperature gradient) |
| Application | Rapid qualitative and semi-quantitative melting point determination of organic crystalline solids |
| Brand | Karg |
|---|---|
| Origin | Germany |
| Model | SC-1693 |
| Temperature Range | 50–100 °C |
| Test Compliance | ASTM D1693 |
| Notch Dimensions | 19.0 ± 0.5 mm (length) × 0.50 ± 0.05 mm (depth) |
| Specimen Dimensions | 38.0 ± 2.5 mm × 13.0 ± 0.08 mm (rectangular) |
| Notch Geometry | U-shaped cross-section |
| Test Vessel | Borosilicate glass tubes |
| Heating System | Precision thermostatic bath with ±0.3 °C stability |
| Control Interface | Integrated digital controller with timer and temperature logging |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | UL94 |
| Chamber Material | Polished Stainless Steel |
| Burner Adjustment | Horizontal travel 240 mm, angular tilt 0°/20°/45° |
| Specimen Holder Travel | Horizontal 840 mm, Vertical 730 mm |
| Specimen Holders | 5 types for multi-standard compliance |
| Timer Range | 0–100 s in 1-s increments |
| Airflow Control | Integrated mass-flow regulated exhaust system |
| Exhaust Fan | Variable-speed centrifugal fan |
| External Dimensions (W×H×D) | 1500 × 1500 × 600 mm |
| Net Weight | 200 kg |
| Applicable Standards | UL 94, ASTM D635, ASTM D3801, ASTM D4804, ASTM D5048, ASTM D4986, IEC 60695-11-10 (replaces ISO 1210), IEC 60695-11-20 (replaces ISO 10351), ISO 9772, ISO 9773 |
| Brand | KB |
|---|---|
| Model | KYH-1000 |
| Type | Coulometric Electrolytic Thickness Gauge |
| Measurement Principle | Controlled-potential anodic dissolution (ASTM B504, ISO 2177) |
| Measurable Layers | Cu₂O and CuO on copper substrates |
| Thickness Range | 0.00001–6 µm |
| Resolution | 0.00001 µm |
| Voltage Output | 0–5 V DC, digitally adjustable |
| Current Output | 0–100 mA DC |
| Voltage Resolution | 1 mV |
| Current Resolution | 0.1 mA |
| Sample Diameter Range | 1–25 mm |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 440 × 410 × 135 mm |
| Compliance | NB/T 10194–2019 (Chinese National Standard for Electrolytic Measurement of Copper Oxide Films) |
| Software | KB-ThickControl v3.x with audit trail, data export (CSV, PDF), statistical analysis (mean, SD, CPK), and GLP-compliant user access control |
| Brand | Kegge |
|---|---|
| Origin | Germany |
| Model | proTens |
| Maximum Load Capacity | 250 kN |
| Drive System | Dual-arm screw-driven with solid-state servo and electric control |
| Load Resolution | 120,000 counts |
| Load Accuracy | Class 1 per DIN EN ISO 7500 (0.4–100% of full scale) |
| Test Speed Range | 0.01–2000 mm/min |
| Motor Power Options | 300 W or 900 W |
| Software Interface | Human-centered, compliant with GLP/GMP data integrity requirements |
| Safety Features | Adjustable overload shutdown, quick-release sensor & grip system, precision crosshead guidance |
| Sample Compatibility | Metals, plastics, elastomers, foams, paper, wood, textiles, wires, and finished components |
| Test Modes | Tension, compression, bending, shear, peel |
| Brand | Kegge |
|---|---|
| Origin | Germany |
| Model | smarTens |
| Load Capacity | 20 kN |
| Load Accuracy | Class 1 per DIN EN ISO 7500 (optional Class 0.5) |
| Crosshead Positioning Accuracy | < 1 µm |
| Speed Range | 0.01–1000 mm/min |
| Control System | Solid-state servo motor with dual-arm screw drive |
| Software | Integrated PC-based control and analysis platform |
| Compliance | DIN EN ISO 7500-1, ASTM E4, ASTM E8/E21, ISO 6892-1, ISO 178, ISO 14129, ISO 14130 |
| Sample Compatibility | Metals, plastics, elastomers, foams, paper, wood, textiles, composites, wire, finished components |
| Safety Features | Adjustable overload cutoff, quick-release load cell & fixture interface, precision crosshead guidance system |