Physical Property Testing Instruments
Filter
Showing 9451–9480 of 12286 results
| Brand | Haytham |
|---|---|
| Model | Red Box SH |
| Origin | Guangdong, China |
| Deformation Measurement Range | 0–1000% |
| Linearity | ±0.5% |
| Application Temperature Range | Up to 2200 °C (dependent on optical configuration and furnace integration) |
| Measurement Principle | Stereo Digital Image Correlation (DIC) with High-Speed CMOS Imaging and Real-Time 3D Displacement Reconstruction |
| Brand | Red Sun Instrument |
|---|---|
| Model | HRQS-37A |
| Measurement Principle | Schering Bridge (High-Voltage AC Null Detection) |
| Frequency | 50 Hz / 60 Hz (Power Frequency), Optional 100 Hz–10 kHz Range |
| Test Voltage | Up to 2.5 kV AC (RMS), Adjustable |
| Capacitance Range | 1 pF – 25 µF |
| Dissipation Factor (tan δ) Range | 0 – 1 |
| tan δ Accuracy | ±1.5% of reading ±0.0001 |
| Relative Permittivity (εᵣ) Resolution | 0.01 |
| εᵣ Accuracy | Derived from Cₓ/Cₙ with calibrated standard capacitor (Cₙ = 100 pF) |
| Temperature Control | Dual-zone PID-controlled heating (inner/outer chambers), simultaneous internal/external temperature monitoring |
| Compliance | ASTM D150-11, GB/T 1409-2006, GB/T 1693-2007, GB/T 5594.4-2015 |
| Data Output | Analog voltage signals + RS232 interface |
| Operating Environment | 20 ± 5 °C, 30–80% RH |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRJC-2000V |
| Maximum Output Voltage | AC/DC 0–50 kV |
| Rated Power Capacity | 3 kVA |
| Voltage Ramp Rate | 0.1–5 kV/s (adjustable) |
| Test Modes | AC/DC Uniform Ramp, Stepwise Ramp, and Withstand Testing |
| Compliance Standards | GB/T 1695-2005, GB/T 4109-2008, DL 418-91, ASTM D149, IEC 60243-1 |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | M-200 |
| Instrument Type | Multi-Function Tribological Tester |
| Maximum Friction Force | 20 N |
| Friction Force Resolution | 0.4 mN |
| Maximum Operating Temperature | 45 °C |
| Maximum Test Load | 2000 N |
| Load Accuracy (≥10% FS) | ±2% |
| Load Repeatability (≥10% FS) | ≤2% |
| Friction Torque Range | 0–15 N·m |
| Torque Accuracy (≥10% FS) | ±3% |
| Torque Repeatability (≥10% FS) | ≤3% |
| Lower Specimen Shaft Speed | 200–400 rpm (stepless) |
| Upper Specimen Shaft Speed | 180/360 rpm |
| Axial Travel of Upper Specimen | ±4 mm |
| Time Control Range | 1 s – 9999 min |
| Revolution Count Range | 1 – 999999 |
| Specimen Dimensions | 30 mm × 7 mm × 6 mm |
| Counterface Ring | Ø40 × 10 mm, hardened 45# steel (HRC 40–45), surface roughness Ra ≤ 0.8 µm, concentricity < 0.01 mm |
| Normal Load Options | 196 N (±0.1%), extendable to 392 N |
| Standard Weights | One 4 kg + four 1 kg calibrated masses |
| Water Bath Integration | Yes |
| Power Supply | 120/230 V, 50/60 Hz, 2 A / 1 A |
| Dimensions (L×W×H) | 330 × 500 × 460 mm |
| Weight | 33 kg |
| Compliance Standards | ASTM D3514, D3885, D3886 |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 040101 |
| Price | Upon Request |
| Load Capacity | 0–5,000 N |
| Force Resolution | 0.5 N |
| Sensor Accuracy | ±0.1% of full scale |
| Measurement Range | 10–5,000 N |
| Test Speed | 3–125 mm/min (electronically controlled, programmable) |
| Test Plate Dimensions | 150 × 150 mm (L × W) |
| Maximum Travel Height | 140 mm |
| Plate Parallelism | ≤1/1000 mm (axial), <0.05 mm (lateral) |
| Return Speed | 125 mm/min |
| Drive System | DC servo motor with low-friction dual-column guidance |
| Overload Protection | Dual fixed + dual movable limit switches |
| Leveling | Four adjustable anti-vibration feet |
| Interface | RS-232 serial port |
| Compatible Software | REGISTRA III |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 300 × 460 × 720 mm |
| Net Weight | 65 kg |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | DMC-196 |
| Measurement Mode | Isothermal Microcalorimetry |
| Instrument Type | Calvet-type Heat Flow Calorimeter |
| Key Features | Ultra-low temperature capability, high-sensitivity 3D thermopile sensor, dual-mode (DSC & IMC), high-pressure compatibility up to 350 bar |
| Temperature Range | −196 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.1 µW (heat flow) |
| Temperature Scan Rate | 0.001–1 °C/min |
| Single-sample Test Duration | ~15 min |
| Calorimetric Cell Max Pressure Rating | 350 bar |
| Heat Capacity (typical) | ~10,500 J/K |
| Pressure Resolution | 0.1 µW (equivalent heat flow resolution under pressure coupling) |
| Outer Dewar Volume | Up to 12.5 mL |
| Inner Sample Cell Volume | Up to 12.5 mL |
| Peak-to-Peak Noise Level | 1 µW |
| Calorimetric Accuracy | ±0.1% |
| Calorimetric Precision | ±0.2% |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Calvet-type Microcalorimeter |
| Measurement Modes | Isothermal Microcalorimetry (IMC) & Differential Scanning Calorimetry (DSC) |
| Sample Capacity | Up to 12.5 mL |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy & Precision | ±0.1 °C |
| Temperature Scan Rate | 0.001–2 °C/min |
| Heat Flow Resolution | 0.1 μW |
| Baseline Noise (Peak-to-Peak) | ≤1 μW |
| Calorimetric Accuracy | ±0.2% |
| Calorimetric Precision | ±0.2% |
| Maximum Pressure Rating (High-Pressure Cell) | 100 MPa (1,000 bar) |
| Pressure Resolution | 350 bar (for integrated pressure tracking cells) |
| External Bath Volume | Up to 12.5 mL |
| Internal Bath Volume | 12.5 mL |
| Dimensions | 29 cm × 29 cm × 63 cm |
| Weight | 25 kg |
| Power Supply | 110–240 V, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSC-790 |
| Sample Capacity | Single |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −150 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| DSC Heat Flow Range | ±6000 mW |
| Cooling Options | Liquid Nitrogen, Mechanical, or Ambient Air |
| Heating Rate | 0.01–100 °C/min |
| Heat Flow Resolution | 0.1 µW |
| Calorimetric Accuracy | ±0.1% |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual-gas inlet with software-driven automatic switching |
| Dimensions (W×D×H) | 950 mm × 555 mm × 360 mm |
| Weight | 30 kg |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Isothermal Microcalorimeter |
| Instrument Category | Cone Calorimeter (Note: *This is a misclassification in source data |
| Model | MIC-90 |
| Measurement Mode | Isothermal |
| Temperature Range | 3 °C to 95 °C |
| Temperature Stability | ±0.001 °C |
| Temperature Precision | ±0.15 °C |
| Single-Sample Measurement Time | ~15 min |
| Heat Capacity (System) | ~10,500 J/K |
| Outer Bath Volume | 25 mL |
| Inner Bath Volume | 25 mL |
| Channel Configurations | 3-channel or 8-channel swappable modules |
| Detection Limit | 2 μW (8-ch), 8 μW (3-ch) |
| Short-Term Noise | <1 μW (8-ch), <8 μW (3-ch) |
| Baseline Drift (24 h) | <5 μW (8-ch), <55 μW (3-ch) |
| Measurement Range | ±900 mW |
| Sample Cell Volume Options | 25 mL or 100 mL |
| Cell Materials | Borosilicate glass, stainless steel, or custom polymer |
| In-situ Mixing | Motorized stirrer with adjustable speed |
| Thermal Sensing Principle | Differential Seebeck-effect planar thermopile sensors |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Reaction Calorimeter |
| Automation Level | Fully Automated |
| Temperature Range (Reactor) | –25 °C to 200 °C |
| Temperature Range (Oil Bath) | –45 °C to 250 °C |
| Temperature Resolution | 1.0 mK |
| Temperature Control Precision | ±0.1 K |
| Calorimetric Methods | Heat-Flow, Power Compensation (optional), Reflux (optional) |
| Reactor Volume | 1000 mL (customizable) |
| Maximum Operating Pressure | 10 MPa |
| Stirring Speed | up to 2000 rpm |
| Torque | up to 75 N·cm |
| Oil Circulation Rate | 35–76 L/min |
| Calibration Heater | 0–50 VDC / 3.00 A / 120 W |
| Power Supply | 3×400 V / 50 Hz (±10%) / 20 A |
| Total System Power | 7000 W |
| Oil Bath Dimensions | 600 × 700 × 1300 mm |
| Oil Bath Weight | 210 kg |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Manufacturer |
| Model | STA-790 |
| Temperature Range | Ambient to 1300 °C / 1600 °C |
| Heating Rate | 0.01–50 °C/min |
| Thermogravimetric (TGA) Range | ±200 mg / ±1000 mg |
| TGA Resolution | 0.02 µg |
| DSC Resolution | 1 µW |
| Atmosphere Control | Dual independent mass-flow-controlled gas lines with software-programmable switching |
| Crucible Options | Al₂O₃, quartz, BN (optional) |
| Furnace Cooling | Integrated water-cooled furnace housing |
| Power Supply | 220 V, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TGA-790 |
| Pricing | Upon Request |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 700 °C |
| Balance Sensitivity | ±0.01 µg |
| Temperature Calibration Method | Curie Point Reference |
| Heating/Cooling Rate | 0.01–50 °C/min |
| Mass Range | ±200 mg |
| Mass Resolution | ±0.02 µg |
| Atmosphere Control | Dual Independent Mass Flow Controllers (MFCs), Software-Programmable Gas Switching |
| Crucible Options | Alumina, Platinum |
| Furnace Cooling | Water-Cooled |
| Furnace Liner | Dust-Free Recirculating Cooling System |
| Power Supply | 220 V, 50/60 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Relia-Burn |
| Pricing | Available Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Relia-Burn |
| Price | USD 1,420 (FOB Tianjin) |
| Compliance | ISO 6940/6941/10047/15025, BS 5438/5722/EN 1103/13772, EN 71-2, GB/T 8745/8746/5456, AS 2755.1–3 |
| Flame Source | Adjustable butane/propane burner (0–600 W), electric spark ignition |
| Radiator | 500 W Epiradiator (120 mm Ø quartz disc) |
| Test Chamber Volume | ≥ 4 m³ |
| Positioning Accuracy | ±0.18° (burner angle), stepper motor–driven linear & rotational motion |
| Control System | Siemens HMI + PLC with preloaded test protocols |
| Sample Mounting | 8 standardized needle frames + stainless steel specimen clamps |
| Safety | Floor-standing design, external operation mode, 180° rotatable support arm, 360° rotatable touchscreen |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Dual-Drum |
| Price | USD 6,400 (FOB Shanghai) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | RS-WD |
| Instrument Type | Temperature Transmitter |
| Output Options | 4–20 mA / 0–5 V / 0–10 V |
| Supply Voltage | 10–30 V DC |
| Default Temperature Accuracy | ±0.5 °C @ 25 °C |
| Extended Range Accuracy | ±1.0 °C @ 25 °C |
| Transmitter Operating Temp. | −20 to +60 °C |
| Probe Operating Temp. | −40 to +80 °C (standard) |
| Probe Humidity Range | 0–100 %RH |
| Response Time (1 m/s airflow) | ≤10 s |
| Load Capacity | ≤600 Ω (current output), ≤250 Ω (voltage output) |
| Mounting Cutout | 60 mm² |
| Display | Integrated LCD |
| Brand | Resonance Systems |
|---|---|
| Origin | Germany |
| Model | TD-NMR Spin Track |
| Principle | Time-Domain Nuclear Magnetic Resonance (TD-NMR) |
| Analysis Stations | Multi-station configuration available |
| Frequency Range | 1 kHz – 100 MHz |
| Specific Surface Area Range | 0.1 – 2500 m²/g |
| Detectable Nuclei | ¹H (standard), optional: ²H, ¹⁹F, ²³Na, ³¹P, ²⁷Al |
| Compliance | ISO 8292, ISO 10565, ISO 10632, ASTM D7171-05 |
| Brand | RESUNTECH |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NanoCoulter G |
| Price Range | USD 84,000–112,000 (FOB) |
| Size Range | 60–2000 nm |
| Size Reproducibility | >90% |
| Temperature Range | 5–40 °C |
| Temperature Control Accuracy | ±5 °C |
| Detection Principle | Resistive Pulse Sensing (RPS) |
| Sample Volume | 30–50 µL |
| Particle Concentration Range | 1×10⁶–1×10¹² particles/mL |
| Zeta Potential Range | −200 to +200 mV |
| Measurement Time | 5–10 min |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail Enabled |
| Dimensions | 27 × 16.5 × 19 cm |
| Weight | 8 kg |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS |
| Dimensions | 200 × 50 mm, 200 × 25 mm, 203 × 50 mm (8" × 2") |
| Material | ASTM F899 Grade 316L Stainless Steel (1.4435) |
| Compliance | ISO 3310-1, ASTM E11, USP <786> |
| Certification Options | Traceable Calibration Certificate (ISO/IEC 17025 accredited), QC Test Report with Graphical & Tabular Data |
| Weight Reduction | ~15% vs. Conventional Sieves |
| Sieve Frame | Monolithic Deep-Drawn Construction |
| Mesh Bonding | Resistance Welding |
| Sealing Integrity | Optimized Stack Interlock Design |
| Surface Finish | Electropolished (Ra ≤ 0.4 µm) |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS200 Control |
| Principle | Electromagnetically Driven Vibratory Sieving |
| Measurement Range | 20 µm – 25 mm |
| Maximum Load | 3 kg |
| Sieve Stack Capacity | 11 or 22 sieves |
| Amplitude Range | 0.2–3 mm (digitally controlled) |
| Acceleration | 1.0–15.1 g |
| Sieving Time | 1–99 min (digital display) |
| Intermittent Mode | 1–99 s |
| Programmable Methods | 99 |
| Sieve Diameters Supported | 100 mm, 200 mm, 203 mm (8") |
| Max. Sieve Tower Height | 620 mm |
| Enclosure Rating | IP21 |
| Power Supply | 100–240 V, 50/60 Hz |
| Dimensions (W×H×D) | 417 × 212 × 384 mm |
| Net Weight | ~35 kg |
| Compliance | CE, ISO 9001 compatible, GLP/GMP-ready with audit trail-capable calibration documentation |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS200 DIGIT CA |
| Principle | Electromagnetically Driven Vibratory Sieving |
| Measurement Range | 20 µm – 25 mm |
| Max. Load | 3 kg |
| Max. Sieve Stack Height | 510 mm |
| Sieve Levels | 9 or 17 |
| Amplitude Control | Digital, 0.2–3.0 mm |
| Sieving Time | 1–99 min (digital display) |
| Intermittent Mode | Fixed 10 s on/off cycles |
| Sieve Diameters Supported | 100 mm, 200 mm, 203 mm (8") |
| Enclosure Rating | IP21 |
| Net Weight | ~35 kg |
| Compliance | CE |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS200 Digital |
| Measurement Range | 20 µm – 25 mm |
| Max. Sample Load | 3 kg |
| Max. Sieve Stack Mass | 6 kg |
| Sieve Diameter Options | 100 mm / 150 mm / 200 mm / 203 mm (8") |
| Sieve Stack Height | up to ~450 mm |
| Dimensions (W × H × D) | 400 × 230 × 350 mm |
| Net Weight | ~30 kg |
| Drive Type | Electromagnetic, 3D oscillation |
| Programmable Methods | 9 stored parameter sets |
| Compliance | CE, DIN EN ISO 9000 series, GLP-ready |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS200 Jet |
| Principle | Air jet sieving (dynamic air-assisted vibration) |
| Measurement Range | 10 µm – 4 mm |
| Maximum Sample Load | 0.3 g – 100 g (standard operation) |
| Sieve Stack Capacity | 1 sieve (2-stage separation possible when combined with integrated cyclone separator) |
| Sieve Diameter Compatibility | 200 mm (8") |
| Vibration Frequency | 280 min⁻¹ (4.67 Hz) |
| Tapping Intensity | 150 taps per cycle |
| Operating Mode | Fixed-amplitude, digitally controlled air pulse modulation |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS200 Tap |
| Measurement Range | 20 µm – 25 mm |
| Max. Sample Capacity | 3 kg |
| Max. Number of Sieves | 13 |
| Max. Sieve Stack Mass | 6 kg |
| Timer Range | 1–99 min (digital display) |
| Tap Frequency | 150 or 280 taps/min |
| Compatible Sieve Diameter | 200 mm / 203 mm (8") |
| Max. Sieve Stack Height | ~350 mm |
| Dimensions (W × H × D) | 750 × 650 × 450 mm |
| Net Weight | ~68 kg |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS300 Control |
| Operating Principle | Electromagnetic 3D throw motion |
| Max. Sample Load | 6 kg |
| Max. Sieve Stack Mass | 10 kg |
| Sieve Diameter Options | 100 / 150 / 200 / 203 / 305 / 315 mm |
| Measurement Range | 36 µm – 40 mm |
| Amplitude Adjustment | 0.2–>2 mm (digital) |
| Acceleration | 1.0–>10.0 g |
| Timing Range | 1–99 min (digital) |
| Intermittent Mode | 1–99 s |
| Max. Sieve Layers | 9 (standard) / 17 (with extension kit) |
| Programmable Methods | Up to 9 stored protocols |
| Motion Type | Rotational throw with momentum |
| Dry & Wet Sieving | Yes |
| Calibration & Verification Support | Yes |
| Interface | Parallel port |
| Dimensions (W×H×D) | 400 × 235 × 400 mm |
| Net Weight | ~35 kg |
| Compliance | CE-marked, designed per ISO 2591-1, ISO 9276-2, ASTM E11, USP <786> |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS400 Control |
| Screening Motion | Horizontal Circular (DIN 53 477) |
| Speed Range | 50–300 rpm (electronically controlled, continuously adjustable) |
| Display | Digital speed & time readout |
| Motor Power | 125 W |
| Max. Sample Load | 5 kg |
| Max. Sieve Stack Mass | 15 kg |
| Max. Number of Sieves | 17 |
| Sieve Diameter Compatibility | 100 mm / 150 mm / 200 mm / 203 mm (8") / 305 mm (12") / 400 mm |
| Sieve Stack Height | up to ~450 mm |
| Measurement Range | 45 µm – 63 mm |
| Acceleration at Sieve Base | 0.04–1.51 g |
| Time Setting Range | 1–99 min (digital) |
| Intermittent Drive Interval | 1–99 s |
| Programmable Methods | Up to 9 stored protocols |
| Calibration | Traceable, certifiable |
| Compliance | CE-marked, compliant with DIN 53 477, ISO 2591-1, ASTM E11 |
| Interface | Parallel port |
| Dimensions (W × H × D) | 540 × 260 × 507 mm |
| Net Weight | ~70 kg |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS450 Control |
| Principle | Electromagnetic 3D vibratory sieving |
| Measurement Range | 25 µm – 125 mm |
| Max. Sample Load | 25 kg |
| Max. Sieve Stack Levels | 13 (min. 3) |
| Amplitude Range | 0.2 – >2.2 mm |
| Acceleration | 1–7.1 g |
| Sieving Time | 1–99 min (digital display) |
| Intermittent Mode Interval | 10–99 s |
| Stored SOPs | 9 |
| Sieve Diameter Compatibility | 400 mm / 450 mm |
| Max. Sieve Tower Height | 963 mm |
| Net Weight | ~220 kg |
| Power Supply | Single-phase, CE-compliant |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS450 |
| Maximum Sample Load | 20 kg |
| Max. Sieve Stack Mass | 50 kg |
| Sieve Diameter Compatibility | 400 mm / 450 mm |
| Amplitude Range | 0–2.2 mm (digitally adjustable) |
| Oscillation Mode | Three-dimensional throw motion |
| Drive Type | Electromagnetic, intermittent |
| Programmable Methods | 9 stored parameter sets |
| Measurement Range | 20 µm to 125 mm |
| Max. Number of Sieves | 11 (standard) / 14 (with extension kit) |
| Sieve Stack Height | up to ~940 mm |
| Dimensions (W × H × D) | 714 × 435 × 629 mm |
| Net Weight | ~220 kg |
| Compliance | ISO 2591-1, ISO 9276-1, ASTM E11, USP <786> |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | DR100 |
| Feed Rate | 0–5 L/min (infinitely adjustable) |
| Feed Slot Width | 15 mm / 40 mm / 75 mm |
| Feed Slot Length | 210 mm |
| Hopper Capacity | 2.8 L (15/40 mm) / 3.5 L (75 mm) |
| Dimensions (W×H×D) | 260 × 420 × 280 mm |
| Weight | ~10 kg |
| Vibration Frequency | 50/60 Hz |
| Power Supply | 24 W per electromagnet |
| Max. Particle Size | <2 mm (15 mm slot) / <6 mm (40 mm slot) / <12 mm (75 mm slot) |
| Timer | Digital, 1–99 min or continuous operation |
| Compliance | CE certified |
| Maintenance | Maintenance-free design |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | EasySieve |
| Compliance | DIN 66165, ASTM E11, ISO 3310-1, USP <786> |
| Data Export | ASCII, CSV, Excel-compatible |
| Integration | RETSCH “control” series sieve shakers, CAMSIZER®, CRYSTAL-SIZER®, LIMS via EasySieve® Comfort |
| Reporting | Automated DIN-compliant sieve analysis reports with Q₃(x), p₃(x), q₃(x), RRSB parameters, Sauter mean diameter (x₃₂), AFS fineness number, specific surface area (Sᵥ, Sₘ), splinter value, polydispersity index |
