Physical Property Testing Instruments
Filter
Showing 2521–2550 of 12279 results
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Micro Tec² |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ANALYSETTE 22 Micro Tech / Nano Tech |
| Pricing | Upon Request |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 22 Nano Tec |
| Measurement Range | 0.01–2000 µm |
| Laser Sources | Two green lasers (λ = 532 nm, 7 mW each) + one infrared laser (λ = 940 nm, 9 mW) |
| Laser Safety Class | EN 60825-1 compliant, Class 1 |
| Detector Channels | 520 (dual-polarization: vertical & horizontal), including forward and backscattering detection |
| Optical Design | Inverse Fourier configuration with motorized, wide-range sample cell positioning |
| Sample Handling | Modular dry- and wet-dispersion units (optional) |
| SOP Support | Fully configurable, modular Standard Operating Procedures per measurement step |
| Alignment | Automatic beam alignment system |
| Compliance | ISO 13320:2020 (Laser diffraction particle size analysis) |
| Software | FRITSCH ParticleSight™ with customizable reporting, audit trail, background subtraction, automated cleaning cycle, and user-defined dispersion protocols |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fritsch ANALYSETTE 22 NanoTec |
| Pricing | Upon Request |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | Analysette 3 |
| Compliance | ISO 3310, ASTM E11, DIN 66165, EN 10204 3.1B |
| Measurement Range (Dry) | 32 µm – 63 mm |
| Measurement Range (Wet) | 20 µm – 10 mm |
| Measurement Range (Micro-fine) | 5 µm – 100 µm |
| Max Sieve Stack (50 mm) | 10 trays |
| Max Sieve Stack (25 mm) | 16 trays |
| Sample Capacity (Dry, <100 µm) | >100 kg |
| Sample Capacity (Dry, <25 mm) | >1 kg |
| Sample Capacity (Wet) | 20–100 g |
| Sample Capacity (Micro-fine) | 0.2–0.5 g |
| Sieving Duration (Dry) | 3–20 min |
| Sieving Duration (Wet) | 3–10 min |
| Sieving Duration (Micro-fine) | 30–60 min |
| Amplitude Display | Digital (mm) |
| Frequency Display | Digital (Hz) |
| Control Interface | RS232 |
| Software | AUTOSIEVE™ |
| IP Rating | IP65 |
| Tension Control | Electronic torque-controlled sieve clamping system |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 3 PRO |
| Dry Sieving Range | 32 µm – 63 mm |
| Wet Sieving Range | 20 µm – 10 mm |
| Micro Sieving Range | 5 µm – 100 µm |
| Sample Capacity (Dry) | <100 g (for <100 µm), <1 kg (for <25 mm) |
| Sample Capacity (Wet) | 20–100 g |
| Sample Capacity (Micro) | 0.2–0.5 g |
| Sieving Time (Dry) | 3–20 min |
| Sieving Time (Wet) | 3–10 min |
| Sieving Time (Micro) | 30–60 min |
| Max. Stackable Sieve Trays | 10 × 50 mm trays or 16 × 25 mm trays |
| Compliance | ISO 3310-1/-2, ASTM E11, DIN 66165, EN 10204 3.1B |
| Software Interface | AUTOSIEVE (PC-connected, GLP-compliant data logging) |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | Analysette 3 SPARTAN |
| Dry Method Range | 32 µm – 63 mm |
| Wet Method Range | 20 µm – 10 mm |
| Sample Capacity (Dry) | up to 2 kg |
| Sample Capacity (Wet) | 20–100 g |
| Sieving Time (Dry) | 3–20 min |
| Sieving Time (Wet) | 3–10 min |
| Max. Stackable Sieve Trays | 10 × Ø50 mm or 16 × Ø25 mm |
| Sieve Compliance | ISO 3310-1 & ASTM E11 |
| Net Weight | 21 kg |
| Gross Weight | 26 kg |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Dragon |
| Temperature Range | −80 °C to +225 °C |
| Temperature Transition Speed | <10 s (−55 °C ↔ +125 °C) |
| Accuracy | ±1.0 °C (calibrated) |
| Setpoint Resolution | 0.1 °C |
| Airflow Output | 5–20 SCFM (2.4–9.4 L/s, continuous) |
| Power Supply | 200–250 VAC, 50/60 Hz, 20 A, single-phase |
| Noise Level | <49 dBA (average) |
| Compliance | CE certified, CFC-free, GLP/GMP-ready interface support |
| Brand | Froilabo |
|---|---|
| Model | Dragon |
| Origin | Guangdong, China (Distributed by Hongzhan Technology Co., Ltd.) |
| Temperature Range | −80 °C to +250 °C |
| Ramp Rates | −55 °C → +125 °C in 7 s |
| Temperature Accuracy | ±0.1 °C |
| Airflow Control | 2.2–8.4 L/s |
| Operating Modes | Manual / Automatic / Programmable |
| Program Storage | 45 profiles, up to 20 steps per profile |
| Standards Compliance | JEDEC JESD22-A104, MIL-STD-883 Method 1010, MIL-STD-750 Method 1037 |
| Brand | Froilabo |
|---|---|
| Model | Dragon |
| Origin | Guangdong, China (Distributed by Hongzhan Technology Co., Ltd.) |
| Temperature Range | −80 °C to +250 °C |
| Ramp Rates | −55 °C ↔ +125 °C in 7 s / 14 s |
| Airflow | 2.2–8.4 L/s |
| Temperature Stability | ±0.1 °C |
| Control Interface | Touchscreen HMI |
| Program Storage | 45 profiles × 20 steps each |
| Compliance | JEDEC JESD22-A104, MIL-STD-883 Method 1010, MIL-STD-750 Method 1037 |
| Operating Modes | Manual, Auto, Editable Sequence Mode |
| Brand | Froilabo |
|---|---|
| Model | Dragon |
| Origin | France |
| Temperature Range | -75 °C to +250 °C |
| Temperature Stability | ≤ 0.5 °C |
| Temperature Transition Rate | 0.03 °C/s to 15 °C/s (both heating and cooling) |
| Airflow Rate | 2.2 L/s to 8.4 L/s |
| Transition Time | -55 °C ↔ +125 °C in 7 s (hot-to-cold) / 14 s (cold-to-hot) |
| Temperature Control Accuracy | ±0.1 °C |
| Operating Modes | Manual, Automatic, Programmable |
| Programmable Steps | Up to 32 per profile |
| Compliance | MIL-STD-883 Method 1010 & 1051, MIL-STD-750 Method 1051, JESD22-A101D |
| Brand | Froilabo |
|---|---|
| Origin | Guangdong, China (Distributed by Hongzhan Technology Co., Ltd.) |
| Model | Dragon |
| Temperature Range | −80 °C to +250 °C |
| Transition Time | −55 °C ↔ +125 °C in 7 s / 14 s |
| Airflow Rate | 2.2–8.4 L/s |
| Temperature Stability | ±0.1 °C |
| Control Interface | Touchscreen HMI |
| Programmable Profiles | 45 stored programs, up to 20 steps each |
| Compliance | JEDEC JESD22-A104, MIL-STD-883 Method 1010, MIL-STD-750 Method 1037 |
| Operating Modes | Manual, Automatic, Editable Sequence |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Dragon3 |
| High Temperature Range | +250 °C |
| Low Temperature Range | −70 °C |
| Thermal Shock Range | −70 °C to +250 °C |
| Temperature Stability | < ±0.1 °C |
| Ramp Rate (Heating) | ~7 s from −55 °C to +125 °C |
| Ramp Rate (Cooling) | ~14 s from +125 °C to −55 °C |
| Airflow Output | 5–20 SCFM (2.4–9.4 L/s) |
| Temperature Accuracy | ±1.0 °C (calibrated) |
| Setpoint Resolution | 0.1 °C |
| Power Supply | 200–250 VAC, 50/60 Hz, 20 A, single-phase |
| Dimensions (W×D×H) | 57.5 × 92.8 × 136.3 cm |
| Weight (net) | 265 kg |
| Noise Level | < 49 dBA (A-weighted, avg.) |
| Compressed Air Requirement | 15–30 SCFM, dew point ≤ +10 °C, oil content < 0.10 ppm, particulate filtration ≤ 5 µm |
| Brand | Froilabo |
|---|---|
| Origin | Guangdong, China (Distributed by Hongzhan Technology Co., Ltd.) |
| Model | Froilabo “Jielong” Series |
| Temperature Range | −80 °C to +250 °C |
| Ramp Rates | −55 °C ↔ +125 °C in 7 s / 14 s |
| Airflow | 2.2–8.4 L/s |
| Temperature Stability | ±0.1 °C |
| Control Interface | Touchscreen HMI |
| Programmability | Up to 45 stored profiles, 20 steps per profile |
| Compliance | JEDEC JESD22-A104, MIL-STD-883 Method 1010, MIL-STD-750 Method 1037 |
| Operating Modes | Manual, Automatic, Editable Sequence Mode |
| Brand | Froilabo / LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Froilabo Jielong Series Thermal Shock Flow System |
| Pricing | Available Upon Request |
| Brand | Froilabo / LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Froilabo Dragon Series |
| Pricing | Available Upon Request |
| Temperature Range | −80 °C to +250 °C |
| Ramp Rates | −55 °C → +125 °C in 7 s |
| Temperature Stability | ±0.1 °C |
| Airflow Control | 2.2–8.4 L/s |
| Operating Modes | Manual / Automatic / Programmable |
| User Interface | Touchscreen HMI |
| Program Storage | Up to 45 thermal profiles, each with up to 20 steps |
| Standards Compliance | JEDEC JESD22-A104, MIL-STD-883 Method 1010, MIL-STD-750 Method 1037 |
| Brand | Froilabo |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PS-225-W |
| Instrument Type | Upright |
| Temperature Range | 15–45 °C |
| Humidity Range | 20–98 % RH |
| Temperature Uniformity | ±0.5 °C (within chamber at setpoint) |
| Humidity Uniformity | ±2.5 % RH |
| Temperature Stability | ±0.5 °C |
| Humidity Stability | ±3 % RH |
| Heating Rate (non-linear, no-load) | ~3.5 °C/min (20 °C to +150 °C) |
| Internal Dimensions (W×D×H) | 500×750×500 mm |
| External Dimensions (W×H×D) | 985×1800×1035 mm |
| Net Weight | 275 kg |
| Power Supply | AC 380 V / 11.0 A |
| Brand | FSM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FA-2000 |
| Pricing | Available Upon Request |
| Brand | FSM |
|---|---|
| Origin | USA |
| Model | FSM-413 EC |
| Measurement Principle | Infrared (IR) Interferometric EchoProbe™ Technology |
| Substrate Compatibility | Si, GaAs, InP, SiC, Sapphire, Quartz, Glass, Polymers |
| Configurations | Single-Probe (substrate thickness only) / Dual-Probe (total thickness + topography) |
| Optional Modules | Trench/Through-Silicon Via (TSV) Depth, Film Thickness, Bump Height, Surface Roughness (Rq/Ra), Sidewall Angle |
| Compliance | Designed for ISO 9001-certified semiconductor fabrication environments |
| Brand | FSM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VIT |
| Pricing | Available Upon Request |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | ABD0031 |
| Application | Integrated with NBS-type smoke density chamber for aircraft cabin material qualification |
| Core Components | Vacuum chamber, vacuum pump, manual metering pump, gas analysis detector tubes |
| Compliance Context | Airbus ABD0031 specification, ASTM E662, ISO 5659-2, FAA AC 20-135, EN 45545-2 |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | FRP |
| Standards Compliance | EN ISO 9239-1, ASTM E648, ASTM E970, NFPA 253, GB/T 11785 |
| Radiation Source | Gas-fired flat-panel radiator inclined at 30° |
| Radiant Heat Flux Range | 1.1–10.9 kW/m² (extendable to 25.0 kW/m²) |
| Critical Radiant Flux Resolution | 0.1 kW/m² |
| Sample Orientation | Horizontal |
| Ignition | Pilot burner with stainless steel nozzle |
| Smoke Measurement | DIN 50055-compliant optical smoke density system mounted on exhaust duct |
| Dimensions (W×D×H) | 1900 × 750 × 1900 mm |
| Construction | Stainless steel hood, calibrated angular positioning plate, dual-access observation door with sliding platform |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | iCone |
| Compliance | ISO 5660-1 & -2, ASTM E1354, ASTM E1740, ASTM F1550, ASTM D5485, ASTM D6113, NFPA 271, NFPA 264, CAN/ULC-S135, BS 476-15, GB/T 16172 |
| Heat Flux Range | Up to 100 kW/m² |
| Sample Size | 100 mm × 100 mm (max thickness 50 mm) |
| Mass Loss Resolution | 0.01 g |
| Exhaust Flow Rate | 24 L/s |
| Oxygen Analysis | Paramagnetic or Zirconia-based O₂ sensor |
| Smoke Obscuration | He–Ne laser (0.5 mW), Si photodiode detector with ND filters (0.3 & 0.8) |
| Ignition Source | 10 kV spark igniter with auto-positioning and safety cutoff |
| Data Acquisition | Synchronized multi-channel, 100 Hz sampling rate |
| Software | ConeCalc v6.x (Windows-based, multilingual UI) |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | NBS |
| Compliance | ASTM E662, ASTM F814, ISO 5659-2, NFPA 258, BS 6401, GB/T 8323, IMO FTPC Part 2, NES 711 |
| Chamber Dimensions | 914 mm × 914 mm × 610 mm (L×H×W) |
| Radiant Heat Flux Range | 10–50 kW/m² (calibrated at 25 kW/m² ±1 kW/m²) |
| Optical System | 6.5 V Tungsten Lamp + S-4 Spectral Response Photomultiplier Tube (dark current <10⁻⁹ A) |
| Light Beam Transmission Accuracy | 0.01% |
| Optical Density Resolution | 0.01 |
| Mass Loss Measurement Accuracy | ±0.1% |
| Timer Resolution | 0.1 s |
| Cone Heater Power | 2600 W |
| Thermocouples | Dual K-type armored (Cu/Alumel) |
| Heat Flux Meter | Thermopile-based, calibrated to ±1 kW/m² at 25 & 50 kW/m² |
| Ignition | Horizontal single-flame burner (30 mm ±5 mm), spark-ignited without chamber opening |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | Oxygen Bomb Calorimeter |
| Standards Compliance | ISO 1716, ISO 1928, ASTM D240, ASTM D4809, ASTM D5468, ASTM D5865, ASTM E711 |
| Application Scope | Gross Calorific Value (GCV) determination of solid, liquid, and heterogeneous fuels and combustible materials |
| Configuration | Includes main calorimeter unit, high-pressure oxygen bomb assembly, oxygen charging station, calibration accessories (benzoic acid standard, ignition wire, crucibles), and installation kit |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FUD-1 Model-12 |
| Pricing | Available Upon Request |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EVO |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–6,000,000 cP |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Speed Range | 0.01–250 rpm (2600 programmable speeds) |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Viscosity Resolution | 0.01 cP (with LCP adapter), 0.1 cP (<10,000 cP), 1 cP (≥10,000 cP) |
| Transducer Material | AISI 316 stainless steel rotors |
| Data Storage | Internal memory + USB export (TXT, XLSX, PDF) |
| Connectivity | Bluetooth 5.0, Wi-Fi 802.11 b/g/n, USB 2.0 |
| Compliance | ASTM D2196, ISO 2555, ISO 3219, USP <911>, GLP/GMP-ready audit trail in FDB software |
| Brand | Fungilab |
|---|---|
| Origin | USA |
| Model | EVO Expert L/R/H |
| Viscosity Range | 20–106,000,000 cP (mPa·s) |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 0.01–200 rpm |
| Number of Speeds | 54 |
| Compliance | ASTM D1076, D1439, D2196, D2556, D2983, ISO 2555, BS 6075 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Interface | USB 2.0, Wi-Fi (optional), TFT color touchscreen, capacitive touch keypad |
| Data Output | Excel-compatible .csv/.xlsx via FDB software or built-in data logger |
| Calibration | User-accessible viscosity & temperature calibration with PT100 probe |
| Rotors | AISI 316 stainless steel, coded for rapid identification |
| Software | FDB Control Suite (Windows-based), GLP-compliant audit trail, multi-step program storage (up to 9), real-time graphing, shear rate/shear stress calculation (with coaxial rotor geometry) |
| Brand | Fungilab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Expert |
| Instrument Type | Rotational Viscometer |
| Speed Range | 0.01–200 rpm |
| Number of Speeds | 54 |
| Accuracy | ±1% of full scale |
| Repeatability | 0.2% |
| Temperature Range | 0–100 °C (32–212 °F) |
| PT100 Probe Accuracy | ±0.1 °C |
| Resolution | 0.1 °C / 0.17 °F |
| Viscosity Range (L-model) | 20–6,000,000 cP |
| Viscosity Range (R-model) | 100–40,000,000 cP |
| Viscosity Range (H-model) | 200–106,000,000 cP |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Compliance | ASTM D1084, D1286, D1439, D2196, D2393, D2556, D2849, ISO 2555, ISO 1652, BS 6075, BS 5350 |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smart |
| Price Range | USD 1,400–7,000 (est.) |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–320,000,000 cP (depending on spindle/speed combination) |
| Repeatability | ±0.2% |
| Accuracy | ±1% of full scale |
| Viscosity Resolution | 0.01 cP (with LCP adapter), 0.1 cP (<10,000 cP), 1 cP (≥10,000 cP) |
| Temperature Range | −40 °C to +300 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Sensor | PT100 |
| Spindle Material | AISI 316 stainless steel |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Programmable Protocols | 10 stored methods |
| Measurement Modes | TTT (Torque Termination Threshold), TTS (Time Termination Setting) |
| Data Logging | Time-stamped CSV/Excel export |
| Calibration | User-definable viscosity & temperature calibration |
| Language Support | 10 languages including English, German, French, Spanish, Chinese, etc. |